1.
China Occupational Medicine ; (6): 582-2022.
Artigo em Chinês | WPRIM | ID: wpr-976143

RESUMO

@#Objective - ,,,,,- - - To establish a gas chromatographic method for the determination of trans 1 1 1 4 4 4 hexafluoro 2 [ - ()] Methods - () butene HFO 1366mzz E in workplace air. HFO 1366mzz E in air was directly collected with aluminum foil , , , composite plastic bag separated by dimethylpolysiloxane capillary column detected by flame ionization detector and Results - () - 3, quantified with external standard method. The linear range of HFO 1366mzz E was 6.82 68 200.00 mg/m with the 3, correlation coefficient of 0.999 9. The detection limit and the lower limit of quantitation were 0.59 and 1.98 mg/m respectively. - - - The recovery rate was within 95.45% 103.05%. The relative standard deviation of within batch precision and between batch - - , precision were 2.26% 5.07% and 4.09% 6.82% respectively. The samples can be stored at room temperature for at least seven Conclusion , , days. This method is simple to use with a wide linear range low detection limit high accuracy and precision and - () good sample stability. It can be used for the detection of HFO 1366mzz E in the air of workplace

2.
China Occupational Medicine ; (6): 697-2022.
Artigo em Chinês | WPRIM | ID: wpr-976106

RESUMO

@#Objective - - To prepare the GDH 5 air sampling tube for simultaneous collection of eight kinds of chloro nitrobenzene ( ) , compounds CNBs in the air of workplace and establish a matching determination method using gas chromatography. Methods - - , Eight kinds of CNBs in vapor and aerosol state were collected by self developed GDH 5 air sampling tube desorbed , , , by toluene separated by polysiloxane gas chromatography column detected by microcell electron capture detector and Results - ( - quantified by external standard method. It was determined that the air sampling tube was assembled by XAD 2 ion ) - , exchange resin and glass fiber filter membrane. The linear range of CNBs was 0.80 240.00 mg/L and the linear correlation - - coefficients were greater than 0.999 9. The detection limit was 7.87 13.03 μg/L. The minimum detectable concentration was 0.60 3, - 3( ) 1.33 μg/m and the minimum quantitative concentration was 2.00 4.22 μg/m sample 45.00 L . The average desorption - - (RSD) - , - RSD efficiency was 101.2% 110.0%. The within run relative standard deviation was 0.8% 4.1% and the between run - Conclusion - was 0.3% 5.8%. The samples could be stored for more than 30 days at room temperature. GDH 5 air sampling tube and its associated determination method can be used for the collection and determination of eight kinds of CNBs in workplace air.

3.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 633-636, 2018.
Artigo em Chinês | WPRIM | ID: wpr-807060

RESUMO

Objective@#To assess psychological acceptance and occupational stress of medical staff, analyze the relationship among personality, psychological acceptance and occupational stress and discuss the direct or indirect effects of personality to occupational stress.@*Methods@#The gaseous four kinds of carboxylic acids in the workplace air were simultaneously collected by silica gel tube, and then desorbed by deionized water and eluted by ion chromatograph. The the content was detected by conductivity detector.@*Results@#The linear relationship was good in the concentration range of about 0~140 mg/L. The correlation coefficient r>0.999, and the maximum detection limit was 4.5 μg/mL. The sampling efficiency of the four carboxylic acids ranges from 96.10%~100.27%. Through the sample added recovery experiments, the low and high content of the silicone tube samples were detected; and the range of desorption efficiency was 82.18%~100.12%; the range of precision was 0.70%~3.71%.@*Conclusion@#This method adopts deionized water to desorb samples, and the application of ion chromatography detection have reached the requirements of《Guidelines for the establishment of occupational health standards, Part 4: Determination of chemical substances in workplace air》, which can be used in four kinds of workplace air detection of carboxylic acid compounds.

4.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 546-549, 2018.
Artigo em Chinês | WPRIM | ID: wpr-806807

RESUMO

Objective@#To establish the method of detecting the concentrations of diphenylamine in air of workplace with high performance liquid chromatographic (HPLC) .@*Methods@#According to standards of methods for determining the chemical substances in workplace air, diphenylamine in the air was collected by glass fiber filter treated with sulfuric acid, then dissolved by methanol and determined by high performance liquid chromatography with UV-detector.@*Results@#There was a linear relationship within the range of 0-30.0 μg/ml, and regression equation was y=8425.6x-150.7, correlation coefficient was 0.999 9, the detection limit was 0.045 μg/ml. The lowest detected concentration was 0.030 mg/m3 (sampling volume 15 L) . The within-run precision was 2.41 ℅-3.02%, the between-run precision was 3.11%-4.45%. The desorption efficiencies was 97.8℅ and the sampling efficiencies were 100%. The samples in glass fiber filter could be stored for 7 d at room temperature.@*Conclusion@#The present method could meet with the requirements of Guide for establishing occupational health standards-Part 4 Determination methods of air chemicals in workplace and be feasible for determination of diphenylamine in workplace air.

5.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 777-780, 2017.
Artigo em Chinês | WPRIM | ID: wpr-809353

RESUMO

Objective@#To establish a method for rapid determination of 47 volatile organic compounds in the air of workplace using portable gas chromatography-mass spectrometer(GC-MS).@*Methods@#The mixed standard gas with different concentration levels was made by using the static gas distribution method with the high purity nitrogen as dilution gas. The samples were injected into the GC-MS by a hand-held probe. Retention time and characteristic ion were used for qualitative analysis,and the internal standard method was usd for quantitation.@*Results@#The 47 poisonous substances were separated and determined well. The linear range of this method was 0.2-16.0 mg/m3,and the relative standard deviation of 45 volatile ovganic compounds was 3.8%-15.8%. The average recovery was 79.3%-119.0%.@*Conclusion@#The method is simple,accurate,sensitive,has good separation effect,short analysis period, can be used for qualitative and quantitative analysis of volatile organic compounds in the workplace, and also supports the rapid identification and detection of occupational hazards.

6.
China Occupational Medicine ; (6): 201-204, 2016.
Artigo em Chinês | WPRIM | ID: wpr-876933

RESUMO

OBJECTIVE: To explore an improved method for determination of cyclohexane and methylcyclohexane in workplace air by solvent desorption-gas chromatography. METHODS: Cyclohexane and methylcyclohexane in workplace air were collected by activated carbon tubes,desorbed with carbon disulfide,separated by DB-1 capillary chromatography column,detected by flame ionization detector and quantified using the standard calibration curves. RESULTS: The linear range of the concentration of cyclohexane and methylcyclohexane were 1. 0-1 402. 2 and 0. 8-1 999. 4 mg / L respectively.Both the correlation coefficients were 0. 999 9. Both the detection limits were 0. 3 mg / L. The limits of quantification were1. 0 and 0. 8 mg / L respectively. Both the minimum detectable concentrations were 0. 2 mg / m3. The minimum quantitative mass concentrations of cyclohexane and methylcyclohexane were 0. 7 and 0. 6 mg / m3respectively( sample volume was 1. 5L). The average desorption efficiencies were 98. 5%-99. 3% and 97. 6%-99. 0% respectively. The relative standard deviations( RSD) of within-run precision were 0. 36%-0. 59% and 0. 34%-0. 50% respectively. The RSD of between-run precision were 0. 89%-2. 04% and 0. 87%-2. 22% respectively. The samples could be stored for up to 7 days at room temperature. CONCLUSION: This method has features of simple operation,high sensitivity and good precision,which is suitable for simultaneous determination of cyclohexane and methylcyclohexane in workplace air.

7.
Journal of Environment and Health ; (12)2007.
Artigo em Chinês | WPRIM | ID: wpr-676818

RESUMO

Objective To establish a capillary gas chromatography method for the determination of trinitrotoluene (TNT) in workplace air.Methods Using dichloromethane as the eluent,the air was drawn through a glass fiber filter to collect TNT,TNT was extracted from the filter with dichloromethane by an ultrasonic shaker,and the sample was analyzed by OV-17 elastic quartz electron capture detector capillary gas chromatography.Results Under the optimal condition,the lowest detection limit was 0.006 ?g/ml,the lowest detection concentration was 0.001 3 mg/m~3 (based on 45 L air sample).When the concentration of standard solution was 0.040-2.0 ?g/ml,the linear equation was good,r=0.999 8,RSDs were between 0.66%-3.62%,the recovery rates were 90.4%-95.5%.When sample was collected by fiberglass filter paper,the efficiency of desorption was more than 90%,and was stable for at least 7 days at 2℃-8℃.Conclusion This method is applicable to the determination of trinitrotoluene in workplace air.