Nucleus (La Habana) ; (65): 28-31, ene.-jun. 2019. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1091385

RESUMO

Abstract Clinical Computed Tomography (CT) imaging is supported by a patient - technology - observers system. Such system involves dosimetric quantities associated with image quality descriptors, where operational factors are predictors. Knowledge of quantitative association between CT dosimetric and image quality quantities with systemic factors, provides the basis to devise scanner-specific optimization strategies. Kerma indexes were measured with a pencil ionization chamber free in air C a,100 and in phantom C pmma,x (x changes into c and p for center and periphery respectively). Polymethyl Methacrylate (PMMA) standard phantoms were used (diameters of 16 and 32 cm). Several operational factors of a Siemens Sensation 64 Cardiac were considered: estimated spectrums, tube potential F 8 (80 - 140 kV), tube current x time product F 1 (40 - 350 mAs) and total collimation at isocenter F 3 (2,7 - 19,2 mm). The water equivalent radius R w , an important factor for patient Size Specific Dose Estimators (SSDE), was estimated by taking into account the spectrums in each phantom. Average pixel noise was measured from Regions of Interest (ROIs) in water phantoms with radius of 2,5; 3; 6; 8 and 11,5 cm. A linear association was found between C pmma,p and C pmma,c . A dose reduction of C pmma,c = 2 mGy per tube rotation can be obtained from data analysis (head mode), with F 1 = 50 mAs, F 3 = 19,2 mm, resulting in average pixel noise of 20 Hounsfield Units (HU). Knowledge of noise association with C pmma,c provides a straightforward tool for quantitative optimization, considering a systemic approach, which includes patient - technology - observer factors.


Resumen La tomografía computarizada (TC) clínica se basa en un sistema paciente - tecnología - observador. Dicho sistema incluye magnitudes dosimétricas asociadas a descriptores de calidad, donde los factores operacionales son predictores. Conocer la asociación cuantitativa entre magnitudes dosimétricas y de calidad de imagen con factores sistémicos, provee la base para concebir estrategias de optimización específicas por tomógrafo. Se midieron índices de kerma en aire C a,100 y en maniquí C pmma,x (x cambia a c y p para centro y periferia respectivamente) con una cámara de ionización tipo lápiz. Se utilizaron maniquíes de Polimetil Metacrilato (PMMA) con diámetros de 16 y 32 cm. Se consideraron factores operacionales de un equipo Siemens Sensation 64 Cardiac: espectros estimados, tensión del tubo F 8 (80 - 140 kV), producto corriente x tiempo de exposición F 1 (40 - 350 mAs) y colimación total en isocentro F 3 (2,7 - 19,2 mm). El radio agua-equivalente R w es un factor importante para Estimadores de Dosis Específicos del paciente (SSDE), se estimó teniendo en cuenta el espectro en cada maniquí. El ruido promedio de píxel se midió en regiones de interés (ROIs) de imágenes de maniquíes de agua con radios de 2,5; 3; 6; 8 y 11,5 cm. Se encontró una asociación lineal entre C pmma,p y C pmma,c . Se describe una reducción de dosis a C pmma,c = 2 mGy por rotación del tubo mediante el análisis de datos (modo cabeza), con F 1 = 50 mAs, F 3 = 19,2 mm, resultando en un ruido promedio de píxel de 20 Unidades Hounsfield (UH).

2.
Radiol. bras ; 48(6): 363-367, Nov.-Dec. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-771086

RESUMO

Abstract Objective: Derive filtered tungsten X-ray spectra used in digital mammography systems by means of Monte Carlo simulations. Materials and Methods: Filtered spectra for rhodium filter were obtained for tube potentials between 26 and 32 kV. The half-value layer (HVL) of simulated filtered spectra were compared with those obtained experimentally with a solid state detector Unfors model 8202031-H Xi R/F & MAM Detector Platinum and 8201023-C Xi Base unit Platinum Plus w mAs in a Hologic Selenia Dimensions system using a direct radiography mode. Results: Calculated HVL values showed good agreement as compared with those obtained experimentally. The greatest relative difference between the Monte Carlo calculated HVL values and experimental HVL values was 4%. Conclusion: The results show that the filtered tungsten anode X-ray spectra and the EGSnrc Monte Carlo code can be used for mean glandular dose determination in mammography.


Resumo Objetivo: Derivar espectros filtrados de raios X de tungstênio utilizados em sistemas de mamografia digital por meio de simulações Monte Carlo. Materiais e Métodos: Espectros filtrados por filtro de ródio foram obtidos para potenciais do tubo entre 26 e 32 kV. Os valores de camada semirredutora (CSR) dos espectros filtrados simulados foram comparados aos valores obtidos experimentalmente com um detector de estado sólido Unfors modelo 8202031-H Xi R/F & MAM Detector Platinum e unidade base 8201023-C Xi Platinum Plus w mAs em um sistema Hologic Selenia Dimensions utilizado no modo radiografia direta. Resultados: Os valores de CSR calculados mostraram boa concordância quando comparados com os valores obtidos experimentalmente. A maior diferença relativa entre os valores de CSR calculados com Monte Carlo e os valores de CSR experimentais foi 4%. Conclusão: Os resultados demonstram que os espectros filtrados de raios X de ânodo de tungstênio e o código de Monte Carlo EGSnrc podem ser utilizados para determinar a dose glandular média em mamografia.