1.
Chinese Journal of Medical Instrumentation ; (6): 602-607, 2023.
Artigo em Chinês | WPRIM | ID: wpr-1010247

RESUMO

OBJECTIVE@#Reduce the number of false alarms and measurement time caused by movement interference by the sync waveform of the movement.@*METHODS@#Vital signal monitoring system based on motion sensor was developed, which collected and processed the vital signals continuously, optimized the features and results of vital signals and transmitted the vital signal results and alarms to the interface.@*RESULTS@#The system was tested in many departments, such as digestive department, cardiology department, internal medicine department, hepatobiliary surgery department and emergency department, and the total collection time was 1 940 h. The number of false electrocardiograph (ECG) alarms decreased by 82.8%, and the proportion of correct alarms increased by 28%. The average measurement time of non-invasive blood pressure (NIBP) decreased by 16.1 s. The total number of false respiratory rate measurement decreased by 71.9%.@*CONCLUSIONS@#False alarms and measurement failures can be avoided by the vital signal monitoring system based on accelerometer to reduce the alarm fatigue in clinic.


Assuntos
Humanos , Monitorização Fisiológica , Eletrocardiografia , Arritmias Cardíacas , Pressão Sanguínea , Acelerometria , Alarmes Clínicos
2.
Cogit. Enferm. (Online) ; 27: e78748, Curitiba: UFPR, 2022. tab, graf
Artigo em Português | LILACS, BDENF | ID: biblio-1384637

RESUMO

RESUMO Objetivo: medir os efeitos da parametrização dos alarmes sonoros de frequência respiratória dos ventiladores mecânicos para redução do número de alarmes disparados durante o banho no leito. Método: ensaio clínico pragmático, para comparar o número de alarmes do ventilador mecânico nos grupos: intervenção - os alarmes de Frequência Respiratória foram parametrizados no início do banho; controle - não realizada parametrização. Estudo registrado em 27/08/2019 no Registro Brasileiro de Ensaios Clínicos, RBR-6y6tyc, Rio de Janeiro, Brasil. Resultados: os modelos de regressão evidenciaram que a parametrização, realizada e mantida durante e após o banho no grupo intervenção, teve o efeito de aumentar 12,5 e 6,4 vezes, respectivamente, o número médio de disparos de alarmes de frequência respiratória alta; e não teve efeito nos alarmes de frequência respiratória baixa. Conclusão: a contribuição deste estudo é auxiliar os profissionais de saúde na formulação de protocolos de parametrização individualizada dos alarmes dos Ventiladores Mecânicos.


ABSTRACT Objective: to measure the effects of parameterizing the audible respiratory rate alarms of mechanical ventilators to reduce the number of alarms triggered during bed bath. Method: pragmatic clinical trial, to compare the number of alarms of the mechanical ventilator, in the groups: intervention - the Respiratory Rate alarms were parameterized at the beginning of the bath; control - no parameterization performed. Study registered on 27/08/2019 in the Brazilian Registry of Clinical Trials, RBR-6y6tyc, Rio de Janeiro, Brazil. Results: Regression models showed that parameterization, performed and maintained during and after bath in the intervention group, had the effect of increasing the average number of high respiratory rate alarm triggers by 12.5 and 6.4 times, respectively; and had no effect on low respiratory rate alarms. Conclusion: The contribution of this study is to assist health professionals in formulating protocols for individualized parameterization of alarms for Mechanical Ventilators.


RESUMEN Objetivo: medir los efectos de la parametrización de las alarmas sonoras de frecuencia respiratoria de los ventiladores mecánicos para reducir el número de alarmas disparadas durante el baño en cama. Método: ensayo clínico pragmático, para comparar el número de alarmas del ventilador mecánico en los grupos: intervención - se parametrizaron las alarmas de Frecuencia Respiratoria al inicio del baño; control - no se realizó parametrización. Estudio registrado el 27/08/2019 en el Registro Brasileño de Ensayos Clínicos, RBR-6y6tyc, Río de Janeiro, Brasil. Resultados: Los modelos de regresión mostraron que la parametrización, realizada y mantenida durante y después del baño en el grupo de intervención, tuvo el efecto de aumentar 12,5 y 6,4 veces, respectivamente, el número medio de disparos de alarmas de frecuencia respiratoria alta; y no tuvo ningún efecto sobre las alarmas de frecuencia respiratoria baja. Conclusión: la contribución de este estudio es ayudar a los profesionales de la salud en la formulación de protocolos para la parametrización individual de las alarmas de los Ventiladores Mecánicos.


Assuntos
Ventiladores Mecânicos , Alarmes Clínicos , Fadiga de Alarmes do Pessoal de Saúde
3.
Cogitare Enferm. (Impr.) ; 27: e78748, 2022. tab, graf
Artigo em Português | LILACS-Express | LILACS, BDENF | ID: biblio-1375221

RESUMO

RESUMO Objetivo: medir os efeitos da parametrização dos alarmes sonoros de frequência respiratória dos ventiladores mecânicos para redução do número de alarmes disparados durante o banho no leito. Método: ensaio clínico pragmático, para comparar o número de alarmes do ventilador mecânico nos grupos: intervenção - os alarmes de Frequência Respiratória foram parametrizados no início do banho; controle - não realizada parametrização. Estudo registrado em 27/08/2019 no Registro Brasileiro de Ensaios Clínicos, RBR-6y6tyc, Rio de Janeiro, Brasil. Resultados: os modelos de regressão evidenciaram que a parametrização, realizada e mantida durante e após o banho no grupo intervenção, teve o efeito de aumentar 12,5 e 6,4 vezes, respectivamente, o número médio de disparos de alarmes de frequência respiratória alta; e não teve efeito nos alarmes de frequência respiratória baixa. Conclusão: a contribuição deste estudo é auxiliar os profissionais de saúde na formulação de protocolos de parametrização individualizada dos alarmes dos Ventiladores Mecânicos.


ABSTRACT Objective: to measure the effects of parameterizing the audible respiratory rate alarms of mechanical ventilators to reduce the number of alarms triggered during bed bath. Method: pragmatic clinical trial, to compare the number of alarms of the mechanical ventilator, in the groups: intervention - the Respiratory Rate alarms were parameterized at the beginning of the bath; control - no parameterization performed. Study registered on 27/08/2019 in the Brazilian Registry of Clinical Trials, RBR-6y6tyc, Rio de Janeiro, Brazil. Results: Regression models showed that parameterization, performed and maintained during and after bath in the intervention group, had the effect of increasing the average number of high respiratory rate alarm triggers by 12.5 and 6.4 times, respectively; and had no effect on low respiratory rate alarms. Conclusion: The contribution of this study is to assist health professionals in formulating protocols for individualized parameterization of alarms for Mechanical Ventilators.


RESUMEN Objetivo: medir los efectos de la parametrización de las alarmas sonoras de frecuencia respiratoria de los ventiladores mecánicos para reducir el número de alarmas disparadas durante el baño en cama. Método: ensayo clínico pragmático, para comparar el número de alarmas del ventilador mecánico en los grupos: intervención - se parametrizaron las alarmas de Frecuencia Respiratoria al inicio del baño; control - no se realizó parametrización. Estudio registrado el 27/08/2019 en el Registro Brasileño de Ensayos Clínicos, RBR-6y6tyc, Río de Janeiro, Brasil. Resultados: Los modelos de regresión mostraron que la parametrización, realizada y mantenida durante y después del baño en el grupo de intervención, tuvo el efecto de aumentar 12,5 y 6,4 veces, respectivamente, el número medio de disparos de alarmas de frecuencia respiratoria alta; y no tuvo ningún efecto sobre las alarmas de frecuencia respiratoria baja. Conclusión: la contribución de este estudio es ayudar a los profesionales de la salud en la formulación de protocolos para la parametrización individual de las alarmas de los Ventiladores Mecánicos.

4.
Chinese Journal of Medical Instrumentation ; (6): 450-453, 2021.
Artigo em Chinês | WPRIM | ID: wpr-888644

RESUMO

OBJECTIVE@#The patient monitors were used to explore the alarm fatigue in a cardiac care unit and to investigate the awareness and reaction of nurse to alarms.@*METHODS@#A semi-structured survey was taken to acquire nurses' feeling and knowledge about monitoring alarm. Three full-time researchers were scheduled to track the alarms with annotations, and analyze the alarm data of 12 patient monitors using central monitoring system.@*RESULTS@#A total of 72 310 unique alarms occurred in the 67-day study period. About 75.7% of them were physiological alarms and less than 10% of medium-low alarms were false positives. The average alarm rate was 128 alarms/patient-day.@*CONCLUSIONS@#There remains alarm fatigue in CCU, the alarm accuracy has improved than the past by applying new technologies. In some cases, clinicians will pay more attention to trend alarm and combination alarm.


Assuntos
Humanos , Arritmias Cardíacas , Alarmes Clínicos , Eletrocardiografia , Monitorização Fisiológica , Inquéritos e Questionários
5.
Chinese Journal of Medical Instrumentation ; (6): 585-590, 2021.
Artigo em Chinês | WPRIM | ID: wpr-922064

RESUMO

OBJECTIVE@#The patient monitors were used to explore the alarm actuality in a ICU and NICU to investigate the awareness and reaction of medical staff to alarms.@*METHODS@#A series of surveys and interviews were taken to acquire clinicians' feelings and attitudes to monitoring alarms. The researchers were scheduled to track the alarms with annotations, and collect the alarm data of patient monitors using central monitoring system.@*RESULTS@#A total of 235 387 and 67 783 alarms occurred in ICU and NICU respectively. The average alarm rate was about 142 alarms/patient-day in ICU and 96 alarms/patient-day in NICU.@*CONCLUSIONS@#There remains alarm fatigue in ICU and NICU, the main reason is the large number of false alarms and clinically irrelevant alarms. In addition, patient monitor is still in the level of threshold alarms or combined alarms, the data integrity and intelligence level need to be improved in future.


Assuntos
Humanos , Recém-Nascido , Alarmes Clínicos , Eletrocardiografia , Unidades de Terapia Intensiva Neonatal , Monitorização Fisiológica
6.
Chinese Journal of Medical Instrumentation ; (6): 481-486, 2020.
Artigo em Chinês | WPRIM | ID: wpr-880395

RESUMO

OBJECTIVE@#In order to solve alarm fatigue, the algorithm optimization strategies were researched to reduce false and worthless alarms.@*METHODS@#A four-lead arrhythmia analysis algorithm, a multiparameter fusion analysis algorithm, an intelligent threshold reminder, a refractory period delay technique were proposed and tested with collected 28 679 alarms in multi-center study.@*RESULTS@#The sampling survey indicate that the 80.8% of arrhythmia false alarms were reduced by the four-lead analysis, the 55.9% of arrhythmia and pulse false alarms were reduced by the multi-parameter fusion analysis, the 28.0% and 29.8% of clinical worthless alarms were reduced by the intelligent threshold and refractory period delay techniques respectively. Finally, the total quantity of alarms decreased to 12 724.@*CONCLUSIONS@#To increase the dimensionality of parametric analysis and control the alarm limits and delay time are conducive to reduce alarm fatigue in intensive care units.


Assuntos
Humanos , Fadiga de Alarmes do Pessoal de Saúde/prevenção & controle , Arritmias Cardíacas/diagnóstico , Alarmes Clínicos , Unidades de Terapia Intensiva , Monitorização Fisiológica
7.
Chinese Journal of Medical Instrumentation ; (6): 173-175, 2018.
Artigo em Chinês | WPRIM | ID: wpr-689840

RESUMO

This paper proposes a clinical alarm management system based on the theory of the closed loop control. The alarm management mechanism can be divided into the expected standard, improving execution rule, rule execution, medical devices with alarm functions, results analysis strategy and the output link. And, we make relevant application and discussion. Results showed that the mechanism can be operable and effective.


Assuntos
Alarmes Clínicos , Sistemas de Apoio a Decisões Clínicas
8.
An Official Journal of the Japan Primary Care Association ; : 383-385, 2015.
Artigo em Japonês | WPRIM | ID: wpr-377235

RESUMO

Recently, there have been many reports of monitor alarm-related accidents, and we believe this is due to alarm fatigue. To solve this problem, we established a transdisciplinary monitor alarm control team (MACT) at our hospital and conducted an intervention study for the Cardiovascular Department ward. We evaluated the number of alarms before and after the intervention and found that the number of alarms decreased from 1,263.4±453.4 before the intervention to 264.1±128.4 after the intervention.