International Journal of Laboratory Medicine ; (12): 1780-1781, 2016.
Artigo em Chinês | WPRIM | ID: wpr-494872

RESUMO

Objective To evaluate the performance of the MAKER IS1200 automated chemiluminescence analyzer .Methods A series of experiments were designed to evaluate the precision ,reagent open bottle stability ,linearity range and reference interval of the MAKER IS1200 automated chemiluminescence analyzer in 8 items of hepatitis B 5 indexes ,AIDS ,hepatitis C and syphilis ac‐cording to the requirements of CLSI documents ,the detection results were performed the methodological comparison with those de‐tected by Abbott i2000 automated chemiluminescence analyzer .Results Except the total precision of HBEAG low value was slight‐ly higher than 15% of the judgment standard ,other indexes conformed to the requirements ;the open bottle stability of various items of reagent was better ;the quantitative item HBSAB had good linearity within the detection range (r2 >0 .95);in the verification of reference interval ,no outlier was found in each item ;in the methodological comparison ,the other items had good correlation with those detected by the ABBOTT i2000 except anti‐HCV .Conclusion The MAKER IS1200 automated chemiluminescence analyzer has good detection performance and meets the requirements of immunoassay detection in laboratory work .

2.
International Journal of Laboratory Medicine ; (12): 3171-3172,3175, 2014.
Artigo em Chinês | WPRIM | ID: wpr-600027

RESUMO

Objective To investigate the FSH/LH ratio in the evaluation of perimenopausal ovarian function in order to conduct better prevention and treatment of perimenopausal women diseases and preventive measures.Methods 42 perimenopausal women were selected as the research subjects from January 2013 to January 2014,among them,23 women aged 45 - 1,the study group 2 accounted for 68.42%,the study group 1 accounted for 39.13% and the control group accounted for 9.09%,there was statistically significant difference among 3 groups(P <0.05).Conclusion The serum FSH/LH ratio can be used as a reliable index for evaluating the perimenopausal ovarian function.

3.
International Journal of Laboratory Medicine ; (12): 3251-3252, 2014.
Artigo em Chinês | WPRIM | ID: wpr-458490

RESUMO

Objective To study the results comparability of two kinds of different chemiluminescence systems(Antu chemilumi-nescence analyzer ADC CLIA 400 and Siemens centaur xp)in the detection of tumor markers.Methods The tumor markers were detected in 50 specimens by using the Antu chemiluminescence analyzer ADC CLIA 400 and the Siemens centaur xp chemilumines-cence analyzer respectively.Then the results were analyzed and compared.Results The quantitative analysis results on the serum specimens showed that there was no significant difference in the detection results between the two kinds of detection system(P >0.05).The correlation coefficients of 5 test items between the two kinds of detection system were more than 0.836,suggesting a good correlation between the two kinds of method.The accuracy and repeatability of the Siemens centaur xp chemiluminescence ana-lyzer were higher than those of the Antu chemiluminescence analyzer ADC CLIA 400 in detecting the tumor markers.Conclusion The Siemens centaur xp chemiluminescence analyzer is better than the Antu chemiluminescence analyzer ADC CLIA 400 in detec-ting the tumor immune markers.