Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 296
Filtrar
1.
Artigo em Chinês | WPRIM | ID: wpr-1028900

RESUMO

Objective:To analyze factors influencing repigmentation patterns in patients with vitiligo treated with phototherapy.Methods:Clinical data were retrospectively collected from patients with vitiligo treated with 308-nm excimer laser or 308-nm excimer lamp at the Department of Dermatology, Xijing Hospital, Air Force Medical University from June 2013 to May 2022. The treatment frequency was thrice weekly, and skin lesions were evaluated via photographs once every 5 sessions of phototherapy. Chi-square test or Fisher′s exact test was used to analyze associations between clinical characteristics and vitiligo repigmentation patterns.Results:A total of 223 patients with vitiligo were included in this study, including 109 males (48.9%) and 114 females (51.1%), and their ages ( M [ Q1, Q3]) were 20 (10, 28) years. Among the 223 patients, 170 (76.2%) were treated with 308-nm excimer laser, and 53 (23.8%) with 308-nm excimer lamp. The repigmentation patterns included the perifollicular pattern in 63 cases (28.3%), marginal pattern in 97 (43.5%), diffuse pattern in 36 (16.1%), and mixed pattern in 27 (12.1%). Analysis of the associations between clinical characteristics and vitiligo repigmentation patterns showed no significant differences in the repigmentation patterns among vitiligo patients of different genders or different Fitzpatrick skin types (both P > 0.05) ; however, the diffuse repigmentation pattern more frequently occurred in the patients aged ≤ 12 years compared with those aged > 12 years ( χ2 = 7.71, P = 0.005), in the patients with vitiligo in the progressive stage compared with those in the stable stage ( χ2 = 4.59, P = 0.030), and in lesions without white hair compared with those with white hair ( χ2 = 6.75, P = 0.009) ; the mixed repigmentation pattern more frequently occurred in the patients with segmental vitiligo compared with those with non-segmental vitiligo ( χ2 = 11.76, P = 0.001) ; the marginal repigmentation pattern more frequently occurred in lesions on the face and neck ( χ2 = 15.82, P<0.001) and extremities ( χ2 = 11.85, P = 0.001) compared with lesions on the trunk; the perifollicular repigmentation pattern more frequently occurred in the patients with stable vitiligo compared with those with progressive vitiligo ( χ2 = 4.70, P = 0.030), and in skin lesions on the trunk compared with those on face and neck ( χ2 = 13.73, P < 0.001) and extremities ( χ2 = 5.49, P = 0.035) ; after 308-nm excimer laser treatment, the proportions of patients with the marginal repigmentation pattern ( χ2 = 12.30, P < 0.001) and those with the diffuse repigmentation pattern ( χ2 = 5.64, P = 0.018) were significantly higher than those after 308-nm excimer lamp treatment, while the proportions of patients with the perifollicular repigmentation pattern ( χ2 = 7.87, P = 0.005) and those with the mixed repigmentation pattern ( χ2 = 17.13, P < 0.001) were significantly higher after 308-nm excimer lamp treatment than those after 308-nm excimer laser treatment. Conclusion:Patients′ age, clinical types and stages of vitiligo, presence or absence of concomitant white hair, skin lesion sites, and phototherapy modalities were factors influencing the repigmentation patterns of vitiligo.

2.
International Eye Science ; (12): 954-959, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1030827

RESUMO

AIM: To investigate the risk factors of refractive regression after correction of moderate and high myopia by femtosecond laser assisted in situ keratomileusis(FS-LASIK)for 1 a, and construct prediction model.METHODS: A retrospective analysis was performed on the clinical data of 400 patients(800 eyes)with moderate and high myopia undergoing FS-LASIK correction in Xi'an Gaoxin Hospital from June 2017 to November 2018, and the patients were randomly divided into modeling group(n=300)and verification group(n=100)according to a ratio of 3:1. The modeling group was divided into regression group and non-regression group according to the occurrence of refractive regression at 1 a after surgery. The changes of corneal curvature and corneal thickness were observed. Logistic regression analysis was used to screen the risk factors of refractive regression in patients with moderate and high myopia at 1 a after FS-LASIK correction, and the prediction model was built based on the regression coefficient. Receiver operating curve(ROC)was used to evaluate model differentiation.RESULTS:Refractive regression occurred in 44 eyes of the modeling group and 15 eyes of the verification group at 1 a after surgery. The anterior corneal surface curvature in the modeling group was lower than that in the regression group at 6 and 12 mo after surgery(all P&#x003C;0.05). The degree of corneal hyperplasia in the regression group was greater than that in the non-regression group at 1, 3, 6 and 12 mo after surgery(all P&#x003C;0.05). The regression equation of the probability value of refractive regression in patients with moderate and high myopia corrected by FS-LASIK at 1 a after surgery is as follows:P=1/[1+e-(-5.989+0.127×age+2.019×preoperative diopter-0.022×preoperative central corneal thickness+0.043×depth of cutting-1.569×diameter of cutting optical region)], Hosmer-Lemeshow detected the goodness of fit of the regression equation(P=0.818). Internal verification using the modeling group data showed that the area under ROC curve was 0.890(95%CI: 0.843-0.937), the sensitivity was 81.82%, and the specificity was 84.71%. The area under ROC curve was 0.838(95%CI: 0.717-0.959), the sensitivity was 80.00%, and the specificity was 87.57%.CONCLUSIONS:The established risk model has good discriminating validity and can be used to identify the high-risk group of refractive regression at 1 a after FS-LASIK in patients with moderate and high myopia.

3.
Artigo em Chinês | WPRIM | ID: wpr-1024410

RESUMO

Objective To explore the impact of contrast agent concentration on the excimer laser's effect on plaque ablation.Methods Using a laser catheter with a diameter of 0.9 mm,we conducted plaque model ablation experiments employing a 308-nanometer xenon chloride excimer laser.During the excimer laser ablation process,five groups were formed based on the injected contrast agent concentrations:a saline group,25%concentration group,50%concentration group,75%concentration group,and 100%concentration group.Optical coherence tomography was utilized to assess the changes in plaque lumen area after excimer laser ablation,evaluating the impact of contrast agent concentration on the excimer laser's ablation efficacy.Simultaneously,a water manometer was used to measure the shockwave pressure generated by the excimer laser in liquids with different contrast agent concentrations,aiming to explore the correlation between the shockwave pressure of the excimer laser and its ablative effect.Results The ablation areas in the 75%concentration group and the 100%concentration group were similar(P>0.05),both exceeding those in the 50%concentration contrast agent group,25%concentration group,and saline group(all P<0.001).Specifically,the ablation area in the 50%concentration group was significantly larger than that in the 25%concentration group and saline group(both P<0.001),while the 25%concentration group was larger than the saline group(P<0.001).The influence of contrast agent concentration on the shockwave pressure of the excimer laser exhibited a similar trend.Additionally,there was a significant positive correlation between the shockwave pressure generated by the excimer laser and its ablation area(r=0.9987,P<0.001).Conclusions The intensity of excimer laser ablation on plaque tissue can be modulated by altering the contrast agent concentration.These findings offer guidance for the application of excimer laser in conjunction with contrast agent injection techniques in the treatment of coronary artery disease.

4.
Chinese Circulation Journal ; (12): 133-139, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1025445

RESUMO

Objectives:To compare the efficacy of the combination of excimer laser coronary angioplasty(ELCA)and drug-coated balloon(DCB)for in-stent restenosis(ISR)and to evaluate the impact of neointimal tissue characteristics on treatment outcomes. Methods:A total of 96 ISR lesions from 86 patients who underwent optical coherence tomography(OCT)evaluation and DCB with or without ELCA treatment at The First Medical Center of Chinese PLA General Hospital from January 2019 to May 2023 were retrospectively analyzed.ISR lesions were divided into ELCA+DCB group(n=30)and DCB group(n=66).Additionally,ISR lesions were classified as homogeneous and non-heterogeneous patterns based on the OCT characteristics of the neointimal tissue,and the impact on acute lumen gains was compared between different ISR patterns.Acute lumen gain(ΔMLA)was defined as the changes in minimum lumen area before and after the intervention. Results:The ELCA+DCB group had a significantly greater ΔMLA than the DCB group([3.2±0.8]mm2 vs.[2.6±1.4]mm2,P=0.015).Among the ISR with a homogeneous pattern,the ΔMLA of the ELCA+DCB group was significantly greater than that of the DCB group([3.0±0.9]mm2 vs.[2.2±1.1]mm2,P=0.030).There was no significant difference in ΔMLA between the two ISR groups with the non-homogeneous pattern([3.4±0.7]mm2 vs.[3.2±1.5]mm2,P=0.533).There was no death,the rate of target lesion revascularization was similar between the patients with lesions receiving DCB treatment and patients receiving ELCA +DCB treatment(7.4%vs.4.2%,P>0.05). Conclusions:The combination of ELCA and DCB is an effective strategy for treating ISR,which can achieve greater acute lumen gain compared to DCB treatment alone,especially for the treatment of homogenous ISR pattern characterized by OCT.

5.
Arq. bras. oftalmol ; 87(3): e2021, 2024. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1520219

RESUMO

ABSTRACT A 33-year-old male presented with unilateral subacute infectious keratitis 4 weeks after surgery. Corneal inflammation was resistant to standard topical antibiotic regimens. During diagnostic flap lifting and sampling, the corneal flap melted and separated. Through flap lifting, corneal scraping, microbiological diagnosis of atypical mycobacteria, and treatment with topical fortified amikacin, clarithromycin, and systemic clarithromycin, clinical improvement was achieved.


RESUMO Paciente do sexo masculino, 33 anos, apresentou ceratite infecciosa subaguda unilateral 4 semanas após a cirurgia. A inflamação da córnea foi resistente aos regimes de antibióticos tópicos padrão. A aba da córnea foi derretida e seccionada durante o levantamento e amostragem para diagnóstico. A melhora clínica só foi alcançada após levantamento do retalho, raspagem e diagnóstico microbiológico de micobactérias atípicas e tratamento com amicacina fortificada tópica, claritromicina e claritromicina sistêmica.

6.
Arq. bras. oftalmol ; 87(4): e2022, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1520241

RESUMO

ABSTRACT Purpose: This study aimed to report an experiment designed to determine anatomical changes in porcine corneas following placement of a novel polymer implant into the cornea. Methods: An ex vivo porcine eye model was used. A novel type I collagen-based vitrigel implant (6 mm in diameter) was shaped with an excimer laser on the posterior surface to create three planoconcave shapes. Implants were inserted into a manually dissected stromal pocket at a depth of approximately 200 μm. Three treatment groups were defined: group A (n=3), maximal ablation depth 70 μm; Group B (n=3), maximal ablation depth 64 μm; and group C (n=3), maximal ablation depth 104 μm, with a central hole. A control group (D, n=3) was included, in which a stromal pocket was created but biomaterial was not inserted. Eyes were evaluated by optical coherence tomography (OCT) and corneal tomography. Results: Corneal tomography showed a trend for a decreased mean keratometry in all four groups. Optical coherence tomography showed corneas with implants placed within the anterior stroma and visible flattening, whereas the corneas in the control group did not qualitatively change shape. Conclusions: The novel planoconcave biomaterial implant described herein could reshape the cornea in an ex vivo model, resulting in the flattening of the cornea. Further studies are needed using in vivo animal models to confirm such findings.


RESUMO Objetivo: Relatar um experimento projetado para determinar alterações anatômicas em córneas porcinas após a colocação de um novo implante de polímero na córnea. Métodos: Foi utilizado olho de porco ex vivo. Um novo agente modelador biocompatível, de colágeno tipo 1, com 6mm de diâmetro foi moldado com excimer laser em sua face posterior, para criar três formatos planocôncavos. Os implantes foram inseridos dentro de um bolsão, dissecado manualmente, a 200 micrômetros (μm). Foram definidos três grupos de tratamento: grupo A (n=3), teve a profundidade máxima de ablação de 70 μm; o grupo B (n=3), profundidade máxima de ablação de 64 μm; e o grupo C (n=3), profundidade máxima de ablação de 104 μm, com buraco central. O grupo controle, D (n=3), foi incluído, com a criação do bolsão estromal, porém sem inserir o material. A avaliação desses olhos foi realizada por tomografia de coerência óptica (OCT) e por tomografia corneana. Resultados: A tomografia corneana mostrou uma tendência para diminuição da ceratometria média em todos os 4 grupos. A tomografia de coerência óptica mostrou córneas com implantes localizados no estroma anterior e aplanamento visível, enquanto as córneas não mudaram qualitativamente o formato no grupo controle. Conclusões: O novo implante de biomaterial planocôncavo descrito aqui foi capaz de remodelar a córnea em modelo de animal ex vivo, resultando no aplanamento corneano. Novos estudos são necessários usando modelos animais in vivo para confirmar tais achados.

7.
Arq. bras. oftalmol ; 87(6): e2021, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513690

RESUMO

ABSTRACT The occurrence of corneal ectasia after photorefractive keratectomy is a rare but serious complication of refractive surgery. Possible risk factors are not well assessed, but a probable reason is the failure to detect keratoconus preoperatively. In this report, we describe a case of corneal ectasia after photorefractive keratectomy in a patient who presented a suspicious tomography pattern preoperatively but had no degenerative alterations associated with pathologic keratoconus, as revealed by in vivo corneal confocal microscopy. We also review eligible case reports of post-photorefractive keratectomy ectasia to find similar characteristics.


RESUMO A ocorrência de ectasia corneana após ceratectomia fotorrefrativa é uma complicação rara, porém grave, em cirurgia refrativa. Os possíveis fatores de risco não são bem avaliados, mas a opinião atual é que a falha na detecção de ceratocone pré-operatório possa ser o principal motivo. Neste relato, descrevemos um caso de ectasia corneana após ceratectomia fotorrefrativa em paciente apresentando padrão tomográfico suspeito no pré-operatório, mas sem alterações degenerativas associadas a ceratocone patológico, conforme revelado por microscopia confocal in vivo da córnea. Além disso, revisamos, na literatura, relatos de casos elegíveis de ectasia pós-ceratectomia fotorrefrativa para encontrar características semelhantes.

8.
Arq. bras. oftalmol ; 87(4): e2023, 2024. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1557099

RESUMO

ABSTRACT We present a case of a patient complaining of monocular diplopia due to a decentered ablation after LASIK. The patient underwent a wavefront-guided retreatment, which resulted in an epithelial ingrowth complication. Additionally, the patient developed cataract, with cataract surgery requiring reliable biometric measurements. Therefore, we opted for corneal treatment and corneal surface regularization. Although we attempted to lift the flap and wash the interface initially, the procedure proved unsuccessful, thereby necessitating immediate flap amputation. Once the corneal surface was regularized in the seventh postoperative month, transepithelial photorefractive keratectomy was successfully performed to homogenize the ocular surface, thereby significantly improving the patient's corrected visual acuity and resolving monocular diplopia. The surface and corneal curvature stabilized by the fifth month after the procedure. Phacoemulsification was then performed along with the implantation of a toric monofocal lens, which was selected using an appropriate formula, resulting in an excellent uncorrected visual acuity.

9.
Indian J Ophthalmol ; 2023 Sep; 71(9): 3210-3218
Artigo | IMSEAR | ID: sea-225263

RESUMO

Purpose: Compare the safety and efficacy of wavefront?guided photorefractive keratotomy (PRK) 6 months after cross?linking (CXL) to wavefront?guided PRK alone for refractive correction in patients with bilateral asymmetric corneal topography. Methods: Prospective randomized clinical trial with 16 patients (32 eyes). CXL with subsequent PRK after 6 months in one eye, and PRK alone was performed in contralateral eyes. The follow?up was 10 years. We analyzed visual outcomes, Scheimpflug topography, and corneal haze evaluation. Results: Eyes in the PRK group showed better results than in the CXL + PRK group. Mean postoperative CDVA was 0.044 logmar (SD, 0.073) in the PRK group and 0.1 logmar (SD, 0.21) in the CXL + PRK group, the mean sphere was + 0.21 (SD, 0.6) D in the PRK group and 0.87 (SD, 2.3) D in the CXL + PRK group, and mean SE was ?0.35 (SD, 0.65) D in the PRK group and 0.62 (SD, 2.32) D in the CXL + PRK group. In one patient, a steepening of 2.5 D and a thinning of 17 ?m occurred in PRK alone group. Two patients in the CXL + PRK group presented corneal haze. The overall complication rate was 18,75% (haze and ectasia). Conclusion: Non?simultaneous CXL and PRK procedures yielded good refractive results, but worse than those obtained with PRK alone. Although one patient in the PRK group developed corneal ectasia, the CXL + PRK group had a higher loss of vision lines, indicating less safety

10.
Rev. cuba. oftalmol ; 36(2)jun. 2023.
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1550917

RESUMO

Objetivo: Determinar las aberraciones corneales en pacientes con indicación de cirugía refractiva con láser de excímeros. Métodos: Se realizó un estudio retrospectivo, transversal, descriptivo, con 161 ojos de 81 pacientes adultos, de ambos sexos con indicación de cirugía con láser de excímeros para la corrección de su defecto refractivo. Se definieron como variables edad, sexo, desenfoque, astigmatismo, coma, trefoil y aberración esférica, las que se determinaron por el estudio topográfico de rutina con el topógrafo KeratronTM Scout, Optikon. Resultados: Se obtuvieron los siguientes valores promedios: desenfoque -4,17 ± 0,29 D (-16,15 a 8,5 D) y absoluto 4,94 ± 0,199 (10 a 16,5 D), astigmatismo -1,56 ± 0,09 D (-9,44 a -0,09 D), coma 0,25 ± 0,016 (0,01 a 1,5 D), trefoil 0,204 ± 0,016 (0,01 a 1,18 D) y aberración esférica 0,316 ± 0,018 D (0,0 a 1,27D). En el 75 por ciento de los casos los valores absolutos de desenfoque fueron inferiores a 6,56, de astigmatismo inferior a 0,33 D, de coma menor que 0,33, trefoil inferior a 0,25 y aberraciones esféricas menores que 0,32 D. Conclusiones: Los valores promedio de las aberraciones corneales desenfoque, astigmatismo, coma, trefoil y aberración esférica se encuentran en el rango de los valores reportados en la literatura científica y la distribución de los valores de las aberraciones corneales presentan desplazamiento de la mayoría de los casos hacia los valores más bajo del rango de determinación(AU)


Objective: To determine corneal aberrations in patients indicated for excimer laser refractive surgery. Methods: A retrospective, cross-sectional and descriptive study was carried out with 161 eyes of 81 adult patients of both sexes with indication of excimer laser surgery for the correction of their refractive defect. Age, sex, defocus, astigmatism, coma, trefoil and spherical aberration were defined as variables, determined by routine topographic study with the KeratronTM Scout topographer, Optikon. Results: The following average values were obtained: defocus of -4.17 ± 0.29 D (-16.15 to 8.5 D) and absolute of 4.94 ± 0.199 (10 to 16.5 D), astigmatism of -1.56 ± 0.09 D (-9.44 to -0.09 D), coma of 0.25 ± 0.016 (0.01 to 1.5 D), trefoil of 0.204 ± 0.016 (0.01 to 1.18 D) and spherical aberration of 0.316 ± 0.018 D (0.0 to 1.27D). In 75 percent of the cases, the absolute values for defocus were lower than 6.56; for astigmatism, lower than 0.33 D; for coma, lower than 0.33; for trefoil, lower than 0.25; and for spherical aberrations, lower than 0.32 D. Conclusions: The average values of corneal aberrations for defocus, astigmatism, coma, trefoil and spherical aberration are in the range of values reported in the scientific literature, while the distribution of corneal aberrations values present displacement of most of the cases towards the lower values of the determination range(AU)


Assuntos
Humanos , Astigmatismo/etiologia , Topografia da Córnea/métodos , Procedimentos Cirúrgicos Refrativos/métodos , Epidemiologia Descritiva , Estudos Transversais , Estudos Retrospectivos
11.
Arq. bras. oftalmol ; 86(3): 201-205, May 2023. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1439372

RESUMO

ABSTRACT Purpose: To describe the clinical outcomes of manual scraping of epithelial ingrowth followed by compressed heating air flow after laser in situ keratomileusis (LASIK). Methods: We underwent a retrospective, noncomparative, and interventional case series. Twenty eyes of 17 patients were included in this study. Each patient with a history of LASIK underwent epithelial removal with mechanical debridement followed by compressed heating air flow. Our primary outcome was the recurrence of epithelial ingrowth after 3 months of follow-up, while our secondary outcomes were uncorrected distance visual acuity, corrected distance visual acuity, and complications after surgery. Results: Ten patients (58.8%) were male, and eight eyes of seven (41.2%) patients underwent primary LASIK surgery, while12 eyes of 10 patients had flap-lift retreatment LASIK; sixteen eyes (80.0%) underwent mechanical microkeratome LASIK and four (20.0%) underwent femtosecond laser-assisted LASIK. Mean age at surgical removal of epithelial ingrowth was 37.0 years ± 9.3 years (range 24 to 55 years). There was recurrence of ingrowth in two eyes (10%) after 3 months of follow-up. The mean corrected distance visual acuity of patients before surgery was 0.07 ± 0.09 logMAR, and after the last follow-up was 0.02 ± 0.04 logMAR (p=0.06). The odds ratio of presenting with epithelial ingrowth after LASIK enhancement compared to primary LASIK was 29.41. Conclusion: Manual scraping followed by compressed heating air flow is a safe and effective treatment of clinically significant epithelial ingrowth after LASIK. At the last follow-up, no eye lost any line in corrected distance visual acuity.


RESUMO Objetivo: Descrever os resultados clínicos do tratamento do crescimento epitelial através da técnica de remoção manual seguido da utilização de um compressor de ar comprimido aquecido após a cirurgia de laser in situ keratomileusis (LASIK). Métodos: Vinte olhos de 17 pacientes foram incluídos no estudo. Cada paciente havia sido submetido a cirurgia de LASIK com presença de crescimento epitelial e foi submetido a tratamento cirúrgico para sua retirada. O objetivo primário foi identificar a presença de crescimento epitelial recorrente ao final de 3 meses de seguimento. Os objetivos secundários foram as medidas de acuidade visual sem correção, acuidade visual com correção, e complicações pós-operatórias. Resultados: Dez pacientes (58,8%) eram homens e 7 mulheres. Oito olhos de sete (41,2%) pacientes apresentavam cirurgia de LASIK primária e 12 olhos de 10 pacientes tinham cirurgia de LASIK com retratamento; dezesseis olhos (80%) utilizaram microcerátomo manual e quatro (20%) laser de femtosegundo. A média de idade no momento da cirurgia de remoção do epitélio era de 37,0 anos ± 9,3 (DP) (variando de 24 a 55 anos). Ocorreu recidiva do crescimento epithelial em dois olhos (10%) após 3 meses de seguimento. A acuidade visual sem correção antes da cirurgia era de 0,07 ± 0,09 logMAR, e após a cirurgia passou para 0,02 ± 0,04 logMAR (p=0,06). A chance (odds ration) de aparecimento do crescimento epithelial após uma reoperação de LASIK é 29,41 vezes maior do que no LASIK primário. Conclusão: A técnica de remoção epitelial manual seguida da utilização de ar comprimido aquecido é segura e efetiva no tratamento do crescimento epitelial após LASIK. Ao final do último acompanhamento, nenhum olho apresentou perda de linhas de visão.

12.
Arq. bras. oftalmol ; 86(2): 175-177, Mar.-Apr. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1429842

RESUMO

ABSTRACT The patient was a 26-year-old woman who had manifest refraction and uncorrected and corrected distance visual acuities of -7.00 × -4.50 at 175°, 20/400, and 20/25, respectively, in the right eye, and -3.25 × -5.25 at 179°, 20/200, and 20/25, respectively, in the left eye. In the right and left eyes, the mean corneal thicknesses were 733 and 749 µm, and the maximum epithelial thicknesses were 70 and 68 µm, respectively. Myriads of intraepithelial cysts were observed in the slit-lamp examination. At 30 months after femtosecond laser-assisted laser in situ keratomileusis (femto-LASIK), the manifest refraction and uncorrected and corrected distance visual acuities were respectively 0.00 × -1.25 at 55°, 20/25, and 20/20 in right eye, and 0.00 × -0.50 at 135°, 20/20, and 20/20 in the left eye. In this case of Meesmann dystrophy, myopia was successfully treated with thick flap femto-LASIK without complications or ectasia.


RESUMO A paciente era uma mulher de 26 anos com refração manifesta, acuidade visual para longe não corrigida e corrigida de -7,00 × -4,50 a175°, 20/400 e 20/25 no olho direito e -3,25 × -5,25 a 179°, 20/200 e 20/25 no olho esquerdo. A espessura média da córnea foi de 733 e 749 µm, e a espessura epitelial máxima foi de 70 e 68 µm, respectivamente no olho direito e no esquerdo. Inúmeros cistos intraepiteliais foram observados no exame com lâmpada de fenda. Trinta meses após o femto-LASIK, a refração manifesta, a acuidade visual para longe não corrigida e corrigida eram respectivamente de 0,00 × -1,25 a 55°, 20/25 e 20/20 no olho direito e 0,00 × -0,50 a 135°, 20/20 e 20/20 no olho esquerdo. Neste caso de distrofia de Meesmann, a miopia foi tratada com sucesso com femto-LASIK de retalho espesso sem complicações ou ectasia.

13.
Artigo em Chinês | WPRIM | ID: wpr-1028923

RESUMO

Objective:To investigate the safety and efficacy of excimer laser ablation (ELA) combined with drug-coated balloon (DCB) for the below-the-knee (BTK) artery lesions.Methods:From Jun 2019 to Nov 2022, 22 patients receiving ELA combined with DCB in atherosclerotic lesions of BTK artery at these two centers were retrospectively analyzed.Results:In these 22 patients there were 3 (13.6%) suffering from stenosis and 19 (86.4%) from chronic total occlusion (CTO) lesions. The mean length of lesion was (25.6±5.7) cm. The technical success rate was 95.5%. Flow-limiting dissection was found in 1 (4.5%) patient and a bailout stent was deployed. The mean ankle-brachial index (ABI) significantly improved during the follow-up period compared with that before the treatment. The median follow-up time was 21.5 months. The 1-year primary patency rate was 80.3%Conclusion:ELA combined with DCB was safe and effective in the treatment of atherosclerotic lesions of BTK artery, improving the primary patency.

14.
Artigo em Chinês | WPRIM | ID: wpr-1024388

RESUMO

Objective To explore the safety and efficacy of combining excimer laser coronary angioplasty with drug-coated balloon in the treatment of recurrent in-stent restenosis(R-ISR).Methods Clinical data from a cohort of 27 patients with a total of 30 R-ISR lesions,who underwent treatment with combined excimer laser coronary angioplasty and drug-coated balloons at our hospital from October 2019 to April 2023,were retrospectively analyzed.Patient baseline information,coronary angiography results,procedural details,and in-hospital complications were collected.Follow-up assessments were conducted at 1,3,and 6 months post-intervention to document major clinical events.Results A total of 27 patients[mean age(66.4±9.8)years]with 30 lesions(100%)achieved procedural and treatment success.There were no cases of acute myocardial infarction,coronary perforation,cardiac tamponade,urgent target lesion revascularization,or death during hospitalization.After 6 months of follow-up,there were no occurrences of acute myocardial infarction or death.Two patients(with a total of two lesions)underwent target lesion revascularization,one patient received repeated drug-balloon dilatation,and one patient underwent coronary artery bypass grafting.Conclusions Excimer laser coronary angioplasty combined with drug-coated balloons is a safe and effective treatment strategy for recurrent in-stent stenosis,but further studies are needed for confirmation.

15.
Artigo em Chinês | WPRIM | ID: wpr-1024403

RESUMO

For patients with severe coronary thrombosis burden,when conventional methods still cannot restore ideal blood flow,excimer laser coronary angioplasty(ELCA)can be used as an important auxiliary method for percutaneous coronary intervention(PCI).It can reduce the occurrence of slow blood flow or no-reflow,increase coronary blood flow,improve myocardial perfusion,and achieve higher immediate and clinical success rates.This article introduced the diagnosis and treatment of 3 patients with massive right coronary artery thrombosis treated with ELCA combined with thrombus aspiration.All 3 patients successfully opened blood vessels,significantly reduced the thrombus load,and achieved good immediate and clinical effects.No complications such as vascular perforation and cardiac tamponade occurred during the treatment.

16.
Rev. bras. oftalmol ; 82: e0006, 2023. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1423620

RESUMO

RESUMO Objetivo: Desenvolver e aplicar um questionário eletrônico para avaliação do conhecimento em cirurgia refrativa na população analisada. Métodos: Foi aplicado um questionário eletrônico a uma população composta de 840 participantes voluntários maiores de 18 anos. Resultados: A média da idade dos participantes foi 37,85 anos, sendo 60,1% do feminino. Dentre os participantes, 20,95% reportaram ter sido submetidos a alguma cirurgia ocular prévia, sendo 73,86% com objetivo refrativo. Entre estes, 73,08% mostraram-se satisfeitos/muito satisfeitos com o resultado. O critério mais importante na escolha de um cirurgião refrativo foi a indicação por um conhecido que realizara a cirurgia (43,81%). Destaca-se que os participantes submetidos à cirurgia refrativa discordaram que "a cirurgia é um procedimento simples e isento de riscos" mais do que as demais pessoas (p=0,0045) e também que "o objetivo principal da cirurgia é 'zerar' o grau" (p=0,0252). Conclusão: Nota-se a necessidade de melhorar o conhecimento pré-operatório da população sobre cirurgia refrativa e também de educação continuada para os oftalmologistas. Este estudo fomenta o desenvolvimento de novas ferramentas de educação com informações claras e de fácil acesso, que tenham caráter informativo, e não de convencimento.


ABSTRACT Objective: The purpose of this study was to develop and apply an online questionnaire to assess knowledge in Refractive Surgery in the analyzed population. Methods: An online questionnaire was applied to a population composed of 840 volunteer participants over 18 years of age. Results: The mean age of population was 37.85 years, of whom 60.1% were female. 20.95% of the participants reported having undergone previous eye surgery, 73.86% of which had a refractive objective. Among these, 73.08% were satisfied / very satisfied with the result. The most important criterion when choosing a refractive surgeon was the indication by a friend who underwent the procedure (43.81%). It is noteworthy that the participants who underwent refractive surgery disagreed more than the other people that "the surgery is a simple and risk-free procedure" (p = 0.0045) and that "the main objective of the surgery is to "zero" the diopter" (p = 0.0252). Conclusion: It is essential to improve population's preoperative knowledge about Refractive Surgery, as well as continuing education for ophthalmologists. Therefore, this study encourages the development of new education tools with clear and easily accessible information, which should be informative, and not convincing.

17.
Rev. bras. oftalmol ; 82: e0043, 2023. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1507881

RESUMO

ABSTRACT LASIK is a refractive surgical procedure in which a corneal flap is created to expose the corneal stromal bed. Preoperative estimation of corneal flap thickness is necessary to calculate the percentage tissue altered in LASIK, an important quantitative risk factor for ectasia. The objective of this study was to assess flap thickness and calculate percentage tissue altered to check if unexpectedly thicker flaps and higher percentage tissue altered could pose as risk factors of ectasia. Four subjects (eight eyes) were submitted to mechanical LASIK in 2009 and 2010. Pre and postoperative clinical and tomographic data were reviewed. Mean preoperative estimated percentage tissue altered was 39.18±1.31%, which was borderline for increased ectasia risk when considering the limit of 40%. However, when considering the postoperatively measured flap thickness, the actual mean percentage tissue altered turned out to be 45.17 ± 4.13%, which was significantly higher than predicted preoperatively (p=0.002). Unexpectedly higher postoperative percentage tissue altered may be responsible for corneal ectasia after mechanical LASIK.


RESUMO A LASIK é um procedimento cirúrgico refrativo, no qual um retalho corneano é criado para expor o leito estromal corneano. A estimativa pré-operatória da espessura do retalho corneano é necessária para calcular o percentual de tecido alterado no LASIK, um importante fator de risco quantitativo para ectasia. O objetivo deste estudo foi avaliar a espessura do retalho e calcular o percentual de tecido alterado para verificar se retalhos inesperadamente mais espessos e percentuais de tecido alterado mais altos poderiam representar fatores de risco de ectasia. Quatro indivíduos (oito olhos) foram submetidos à LASIK mecânica em 2009 e 2010. Dados clínicos e tomográficos pré e pós-operatórios foram revisados. A média de percentual de tecido alterado pré-operatória estimada foi de 39,18±1,31%, limítrofe para risco aumentado de ectasia quando considerado o limite de 40%. No entanto, ao considerar a espessura do retalho medida no pós-operatório, o percentual de tecido alterado médio real foi de 45,17±4,13%, ou seja, significativamente maior do que o previsto no pré-operatório (p=0,002). O percentual de tecido alterado pós-operatóriao inesperadamente mais alto pode ser responsável pela ectasia da córnea após LASIK mecânico.


Assuntos
Humanos , Masculino , Feminino , Adulto , Complicações Pós-Operatórias , Retalhos Cirúrgicos/patologia , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Dilatação Patológica/etiologia , Lasers de Excimer/efeitos adversos , Erros de Refração , Córnea/cirurgia , Córnea/patologia , Topografia da Córnea/métodos , Tomografia de Coerência Óptica , Dilatação Patológica/diagnóstico , Procedimentos Cirúrgicos Refrativos/métodos , Lasers de Excimer/uso terapêutico
18.
Arq. bras. oftalmol ; 86(5): e20230070, 2023. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1513677

RESUMO

ABSTRACT Purpose: Postoperative refraction in modern mi­croincision cataract surgery gained extra importance in patients with the previous laser-assisted in situ keratomileusis (LASIK) surgery. The surgically induced astigmatic changes in those eyes may differ not only in magnitude but also in direction compared to virgin corneas. This study aimed to compare the surgically induced astigmatic changes after microscopic cataract surgery between post-LASIK corneas and virgin eyes. Methods: Cases that underwent microincision cataract surgery in eyes with and without previous LASIK surgery were reviewed. The demographics, the axial length at cataract surgery, the central corneal thickness, spheric and cylindric values, keratometry readings, and postoperative posterior corneal astigmatism were retrospectively evaluated. A modified Alpins method was used for astigmatic vector analysis, and baseline astigmatism, surgically induced astigmatism, difference vector, flattening effect, and torque were assessed. Results: A total of 42 eyes from 24 subjects was evaluated. Group I consisted of 14 eyes with the previous LASIK, and Group II included 28 eyes without any refractive surgery. Preoperative mean central corneal thickness in Group I was significantly thinner (p=0.012). There was no significant difference in baseline astigmatism between the groups regarding magnitude and power vectors. After microincision cataract surgery, there were no significant differences in mean spheric and cylindric values and mean keratometry readings (all p>0.05). However, surgically induced astigmatism and difference vector were significantly higher on J45 vector component in post-LASIK eyes and microincision cataract surgery steepening effect on post-LASIK corneas was significantly higher than those in virgin eyes (p=0.001, p=0.002 and p=0.018, respectively). Conclusions: Cataract surgery has steepened the corneas in both groups with a significantly higher steepening effect in post-LASIK eyes. Certainly, corneal topography cataract surgery is particularly helpful to provide more precise surgically induced astigmatism interpretations.


RESUMO Objetivo: A refração pós-operatória na cirurgia mo­derna de catarata por microincisão ganha ainda mais importância em pacientes com cirurgia prévia de ceratomileuse in situ assistida por laser (LASIK). As alterações astigmáticas induzidas cirurgicamente nesses olhos podem diferir não apenas em magnitude, mas também em direção em comparação com córneas virgens. O objetivo deste estudo foi comparar as alterações astigmáticas induzidas cirurgicamente após cirurgia de catarata por microincisão entre córneas pós-LASIK e olhos virgens. Métodos: Foi revisada uma série de casos de cirurgia de catarata por microincisão em olhos com e sem cirurgia LASIK anterior. Os dados demográficos, o comprimento axial no momento da cirurgia de catarata, a espessura central da córnea, os valores esféricos e cilíndricos, as leituras da ceratometria e o astigmatismo corneano posterior pós-operatório foram avaliados retrospectivamente. O método Alpins modificado foi usado para análise vetorial astigmática e foram avaliados o astigmatismo basal, o astigmatismo induzido cirurgicamente, o vetor de diferença, o efeito de achatamento e o torque. Resultados: Ao todo, 42 olhos de 24 indivíduos foram avaliados. O Grupo I consistiu em 14 olhos com LASIK prévio; o Grupo II incluiu 28 olhos sem qualquer cirurgia refrativa. A média da espessura corneana central pré-operatória no Grupo I foi significativamente mais fina (p=0,012). Não houve diferença significativa no astigmatismo basal entre os grupos em termos de magnitude e vetores de potência. Após a cirurgia de catarata por microincisão, não houve diferenças significativas nos valores médios esféricos, cilíndricos e leituras médias de ceratometria (todos com p>0,05). No entanto, o astigmatismo induzido cirurgicamente e o vetor de diferença foram significativamente maiores no componente do vetor J45 em olhos pós-LASIK, e o efeito de aumento da inclinação pela cirurgia de catarata por microincisão nas córneas pós-LASIK foi significativo em comparação com olhos virgens (p=0,001, p=0,002 e p=0,018, respectivamente). Conclusões: A cirurgia de catarata aumentou a inclinação das córneas em ambos os grupos, sendo esse aumento significativamente maior nos olhos pós-LASIK. Certamente, a topografia da córnea antes da cirurgia de catarata é particularmente útil para fornecer interpretações mais precisas do astigmatismo induzido cirurgicamente.

19.
Rev. bras. oftalmol ; 82: e0021, 2023. graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1441325

RESUMO

RESUMO O FemtoLasik é uma das técnicas mais empregadas em cirurgia refrativa, por seus bons resultados refracionais, sua previsibilidade, sua reprodutibilidade e sua segurança. Tem alto grau de satisfação, com rápida recuperação visual. Apesar de as taxas de complicações do FemtoLasik serem pequenas, intercorrências podem existir. O objetivo deste trabalho foi relatar um caso de uma complicação na dissecção da lamela por Lasik com laser de femtossegundo com consequente rasgadura da lamela, sendo aplicado Excimer Laser com mitomicina C 0,02%. O retratamento foi realizado com ablação de superfície (ceratectomia fotorrefrativa) guiada por frente de onda, evoluindo com boa qualidade visual final.


ABSTRACT Femtolasik is one of the most used techniques in refractive surgery due to good refractive results, predictability, reproducibility, and safety, achieving excellent results and a high degree of satisfaction. Although the complication rates are small, it is worth noting that there may be intercurrences. The objective of this work is to report a case of complication in the dissection of the lamella of laser in situ keratomileusis (Lasik) with Femtosecond laser, and subsequent lamella tear. Excimer Laser was applied with mitomycin 0.02% and re-approached with wavefront guided surgery, evolving with good final visual quality.

20.
Artigo | IMSEAR | ID: sea-218427

RESUMO

To consider the clinical significance and features of the formation of a demarcation line in the corneal stroma with various methods of corneal crosslinking.Materials and Methods: Literature data on the evaluation of the effectiveness of various methods of crosslinking by the demarcation line in the corneal stroma were analyzed. The formation of a demarcation line during prophylactic and therapeutic excimer laser crosslinking was studied after various photorefractive operations, keratoconus and other pathologies of the cornea (168 operations).Results: With various methods of crosslinking, including prophylactic and therapeutic excimer laser corneal crosslinking, the depth of the demarcation line in the stroma varied from 1/3 to 2/3 of the corneal thickness. It was noted that the saturation of the corneal stroma with a 0.25% solution of riboflavin is accompanied by a large increasing effect of the optical density in the stroma above the demarcation line at a shallower depth of its occurrence. The severity of the aseptic inflammatory reaction after corneal crosslinking affected the optical density, shape, intensity, and depth of the demarcation line in the stroma. In some cases, the formation of a demarcation line in the stroma was noted when the stroma was saturated with riboflavin immediately after refractive keratoablation without additional UV irradiation. The demarcation line in the stroma was revealed during inflammatory processes in the corneal stroma without the participation of riboflavin and its activation by UV radiation. The study showed that the assessment of corneal crosslinking by the depth of the demarcation line is not an indicator of the photochemical process and the number of crosslinks formed in the corneal stroma.Conclusion: Based on the severity, shape and depth of the demarcation line, it is not possible to judge the density of crosslinks in the corneal stroma, which predetermine its strength properties after one or another method of corneal crosslinking.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA