Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Adicionar filtros








Intervalo de ano
1.
International Journal of Laboratory Medicine ; (12): 3232-3234,3237, 2015.
Artigo em Chinês | WPRIM | ID: wpr-602610

RESUMO

Objective To explore the feasibility of measurement uncertainty in complete blood count using internal quality con-trol(IQC) data associated with Sysmex Network Communication System(SNCS) comparative data .Methods Complete blood count assay including white blood cell(WBC) count ,red blood cell(RBC) count ,hemoglobin(Hb) determination ,hematocrit(HCT) values and platelet(PLT) count were involved to evaluate measurement uncertainty according to the instruction of CNAS-TRL-001 .Meas-urement uncertainty evaluation was established by internal measurement reproducibility using IQC data ,and standard measurement uncertainty by bias using proficiency testing(PT) data and SNCS data ,followed by relative combined standard measurement uncer-tainty and relative expanded measurement uncertainty was calculated .Meanwhile ,the measurement uncertainty was compared by u-sing PT data and SNAS comparative data .Results Relative expanded measurement uncertainty of the above mentioned index by u-sing IQC data associated with PT data was the following :WBC(10 .02% ,7 .24% ,7 .04% ,from level 1 to level 3 respectively) ,RBC (2 .40% ,1 .72% ,1 .92% ,from level 1 to level 3 respectively) ,Hb(3 .54% ,2 .56% ,2 .50% ,from level 1 to level 3 respectively) , HCT(4 .12% ,3 .18% ,2 .86% ,from level 1 to level 3 respectively) ,PLT(15 .36% ,8 .86% ,7 .94% ,from level 1 to level 3 respec-tively) .Relative expanded measurement uncertainty of the above mentioned index by using IQC data associated with SNCS compar-ative data was the following :WBC(11 .66% ,7 .34% ,6 .40% ,from level 1 to level 3 respectively) ,RBC(2 .26% ,1 .60% ,1 .64%from level 1 to level 3 respectively) ,Hb(3 .36% ,2 .36% ,2 .10% ,from level 1 to level 3 respectively) ,HCT (3 .36% ,3 .04% , 3 .18% ,from level 1 to level 3 respectively) ,PLT (13 .34% ,8 .36% ,7 .14% ,from level 1 to level 3 respectively) .Conclusion Measurement uncertainty in complete blood cell could be estimated by using IQC data associated with SNCS comparative data , which is in accord with the instrument of target measurement uncertainty .

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA