Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Indian J Ophthalmol ; 2020 Feb; 68(2): 371-374
Artigo | IMSEAR | ID: sea-197805

RESUMO

Purpose: Glaucoma is the leading cause of irreversible blindness in the world. The current study aims to estimate prevalence, features, and associations of open angle glaucoma (OAG) in a rural and urban East Indian population. Methods: This is a population based cross sectional study with two arms, rural (28 contiguous villages from 13 Gram Panchayats in Balagarh Police Station, Hooghly district) and urban (Kolkata). Individuals residing in the study area aged 40 years and above were included using multistage random cluster sampling. All subjects underwent a detailed ophthalmic examination at our base hospitals including applanation tonometry, ultrasound pachymetry, gonioscopy, and frequency doubling technology perimetry. The primary outcome was the prevalence of POAG (95% CI). Age and gender specific prevalence estimates were calculated. Multiple logistic regressions were used to analyze the risk factors. Results: Data from 7128 and 6964 subjects aged 40 years or older from Kolkata city and Hooghly district, respectively were analyzed. In the urban population, 2.10% (95% CI: 1.99–2.21%) had POAG and 0.15% (95% CI: 0.13–0.17%) had secondary OAG. In the rural population, 1.45% (95% CI: 0.59–2.31%) had POAG and 0.10 ± 0.03% (95% CI: 0.07–0.13%) had secondary OAG. Conclusion: The study concludes that higher age, higher vertical cup disc ratio (VCDR), and lower central corneal thickness (CCT) are important independent predictors of OAG and emphasizes that increased intraocular pressure (IOP) is not POAG. Gonioscopy, disc evaluation, and screening perimetry need to be incorporated in the detection protocol for glaucoma if we intend to lighten the burden of blindness due to glaucoma.

2.
Indian J Ophthalmol ; 2013 Oct ; 61(10): 576-579
Artigo em Inglês | IMSEAR | ID: sea-155422

RESUMO

Aims: The aim of this study was to compare the visual field test results in healthy children obtained via the Humphrey matrix 24‑2 threshold program and standard automated perimetry (SAP) using the Swedish interactive threshold algorithm (SITA)‑Standard 24‑2 test. Materials and Methods: This prospective study included 55 healthy children without ocular or systemic disorders who underwent both SAP and frequency doubling technology (FDT) perimetry visual field testing. Visual field test reliability indices, test duration, global indices (mean deviation [MD], and pattern standard deviation [PSD]) were compared between the 2 tests using the Wilcoxon signed‑rank test and paired t‑test. The performance of the Humphrey field analyzer (HFA) 24‑2 SITA‑standard and frequency‑doubling technology Matrix 24‑2 tests between genders were compared with Mann‑Whitney U‑test. Results: Fifty‑five healthy children with a mean age of 12.2 ± 1.9 years (range from 8 years to 16 years) were included in this prospective study. The test durations of SAP and FDT were similar (5.2 ± 0.5 and 5.1 ± 0.2 min, respectively, P = 0.651). MD and the PSD values obtained via FDT Matrix were significantly higher than those obtained via SAP (P < 0.001), and fixation losses and false negative errors were significantly less with SAP (P < 0.05). A weak positive correlation between the two tests in terms of MD (r = 0.352, P = 0.008) and PSD (r = 0.329, P = 0.014) was observed. Conclusion: Children were able to complete both the visual test algorithms successfully within 6 min. However, SAP testing appears to be associated with less depression of the visual field indices of healthy children. FDT Matrix and SAP should not be used interchangeably in the follow‑up of children.

3.
Indian J Ophthalmol ; 2013 Feb; 61(2): 59-64
Artigo em Inglês | IMSEAR | ID: sea-147860

RESUMO

Background: To compare the usefulness of the traditional pattern-reversal Visual Evoked Potentials (VEP) with multifocal VEP (mfVEP) and Frequency-Doubling Technology (FDT) perimetry in the evaluation of the ocular abnormalities induced by acute or subacute optic neuritis (ON). Materials and Methods: The test results of 24 ON patients were compared with those obtained in 40 normal control subjects. MfVEP recordings were obtained by using an Optoelectronic Stimulator that extracts topographic VEP using a pseudorandom m-sequence stimulus. Receiver operator characteristic (ROC) curves were calculated to determine the sensitivity and specificity of abnormal values. Results: The frequency of the abnormal ocular findings differed in the ON patients according to the used technique. Reduced visual sensitivity was demonstrated in 12 eyes (54.5%) using FDT perimetry; 17 eyes (77.2%) showed decreased amplitude and/or an increase in the implicit time of the P1 wave in mfVEP and 20 eyes (90.9%) showed an abnormal decrease in the amplitude and/or an increase in the latency of the P100 peak at VEP examination. The areas under the ROC curves ranged from 0.743 to 0.935, with VEP having the largest areas. The VEP and mfVEP amplitudes and latencies yielded the greatest sensitivity and specificity. Conclusions: The mfVEP and the FDT perimetry can be used for the evaluation and monitoring of visual impairment in patients with ON. The most sensitive and practical diagnostic tool in patients with ON is, however, the traditional VEP. The mfVEP can be utilized in those cases with doubtful or negative VEP results.

4.
Korean Journal of Ophthalmology ; : 89-99, 2004.
Artigo em Inglês | WPRIM | ID: wpr-94540

RESUMO

The aim of this study was to determine the relationship between the frequency doubling technology (FDT) screening algorithm and parapapillary retinal nerve fiber layer (RNFL) thickness in the eyes of glaucoma suspects and patients with open angle glaucoma. FDT C20-1 screening program and a scanning laser polarimetry (SLP) system (GDx-NFA) was used to assess 53 glaucomatous eyes, 53 glaucoma suspects and 36 normal control eyes. In glaucomatous eyes, there were correlations between the FDT the screening algorithm and RNFL retardation values in several polarimetric indices, most significantly "inferior thickness" (r = -0.321, P = 0.029). In the eyes of glaucoma suspects, however, we observed no correlation between the FDT results and RNFL retardation values (r = 0.080, P > 0.05, "inferior thickness"). In glaucomatous eyes, the abnormal scores obtained with FDT screening program correlated negatively with RNFL retardation values, as measured by SLP. Despite poor correlation between the FDT abnormal score and RNFL retardation value in glaucoma suspects, detection of abnormality using the FDT screening protocol may aid in the assessment of early glaucomatous structural damage.


Assuntos
Humanos , Pessoa de Meia-Idade , Estudo Comparativo , Glaucoma de Ângulo Aberto/diagnóstico , Pressão Intraocular , Lasers , Microscopia Confocal , Fibras Nervosas/patologia , Hipertensão Ocular/diagnóstico , Nervo Óptico/patologia , Testes de Campo Visual/métodos , Células Ganglionares da Retina/patologia
SELEÇÃO DE REFERÊNCIAS