Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 551-555, 2023.
Artigo em Chinês | WPRIM | ID: wpr-981630

RESUMO

OBJECTIVE@#To investigate the feasibility of MRI three-dimensional (3D) reconstruction model in quantifying glenoid bone defect by comparing with CT 3D reconstruction model measurement.@*METHODS@#Forty patients with shoulder anterior dislocation who met the selection criteria between December 2021 and December 2022 were admitted as study participants. There were 34 males and 6 females with an average age of 24.8 years (range, 19-32 years). The injury caused by sports injury in 29 cases and collision injury in 6 cases, and 5 cases had no obvious inducement. The time from injury to admission ranged from 4 to 72 months (mean, 28.5 months). CT and MRI were performed on the patients' shoulder joints, and a semi-automatic segmentation of the images was done with 3D slicer software to construct a glenoid model. The length of the glenoid bone defect was measured on the models by 2 physicians. The intra-group correlation coefficient ( ICC) was used to evaluate the consistency between the 2 physicians, and Bland-Altman plots were constructed to evaluate the consistency between the 2 methods.@*RESULTS@#The length of the glenoid bone defects measured on MRI 3D reconstruction model was (3.83±1.36) mm/4.00 (0.58, 6.13) mm for physician 1 and (3.91±1.20) mm/3.86 (1.39, 5.96) mm for physician 2. The length of the glenoid bone defects measured on CT 3D reconstruction model was (3.81±1.38) mm/3.80 (0.60, 6.02) mm for physician 1 and (3.99±1.19) mm/4.00 (1.68, 6.38) mm for physician 2. ICC and Bland-Altman plot analysis showed good consistency. The ICC between the 2 physicians based on MRI and CT 3D reconstruction model measurements were 0.73 [95% CI (0.54, 0.85)] and 0.80 [95% CI (0.65, 0.89)], respectively. The 95% CI of the difference between the two measurements of physicians 1 and 2 were (-0.46, 0.49) and (-0.68, 0.53), respectively.@*CONCLUSION@#The measurement of glenoid bone defect based on MRI 3D reconstruction model is consistent with that based on CT 3D reconstruction model. MRI can be used instead of CT to measure glenoid bone defects in clinic, and the soft tissue of shoulder joint can be observed comprehensively while reducing radiation.


Assuntos
Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Instabilidade Articular , Articulação do Ombro/diagnóstico por imagem , Luxação do Ombro , Imageamento por Ressonância Magnética/métodos
2.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 533-537, 2023.
Artigo em Chinês | WPRIM | ID: wpr-981627

RESUMO

OBJECTIVE@#To investigate the effectiveness of arthroscopic autologous iliac bone grafting with double-row elastic fixation in treatment of recurrent anterior shoulder dislocation combined with massive glenoid bone defects.@*METHODS@#Between January 2018 and December 2021, 16 male patients with recurrent anterior shoulder dislocation combined with massive glenoid bone defects were treated with arthroscopic autogenous iliac bone grafting and double-row elastic fixation. The patients were 14-29 years old at the time of the first dislocation, with an average age of 18.4 years. The causes of the first dislocation included falling injury in 5 cases and sports injury in 11 cases. The shoulders dislocated 4-15 times, with an average of 8.3 times. The patients were 17-37 years old at the time of admission, with an average age of 25.1 years. There were 5 left shoulders and 11 right shoulders. The preoperative instability severity index (ISIS) score of the shoulder joint was 5.8±2.1, and the Beighton score was 4.3±2.6. The University of California Los Angeles (UCLA) score, Constant score, American Shoulder and Elbow Surgeons (ASES) score, and Rowe score were used to evaluate shoulder function, and the degree of the glenoid bone defect repair was observed based on CT after operation.@*RESULTS@#All incisions healed by first intention, and no complication such as incision infection or neurovascular injury occurred. The patients were followed up 12 months. At 12 months after operation, UCLA score, Constant score, ASES score, and Rowe score all significantly improved when compared with the scores before operation ( P<0.05). CT imaging showed the degree of glenoid bone defect was significantly smaller at immediate, 6 and 12 months after operation when compared with that before operation ( P<0.05), and the bone blocks healed with the scapula, and bone fusion had occurred at 12 months.@*CONCLUSION@#Arthroscopic autologous iliac bone grafting with double-row elastic fixation is a safe treatment for recurrent anterior shoulder dislocation combined with massive glenoid bone defects, with good short-term effectiveness.


Assuntos
Humanos , Masculino , Adolescente , Adulto , Adulto Jovem , Luxação do Ombro/cirurgia , Transplante Ósseo/métodos , Artroscopia/métodos , Instabilidade Articular/cirurgia , Articulação do Ombro/cirurgia , Escápula/cirurgia , Recidiva
3.
Rev. chil. ortop. traumatol ; 63(3): 184-194, dic.2022. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1437127

RESUMO

Las lesiones óseas en el borde anterior del anillo glenoideo secundarias a un episodio de inestabilidad anterior del hombro cada vez son más reportadas. Conocidas como lesión de Bony Bankart, su presencia genera una pérdida de la estabilidad estática glenohumeral que provoca un aumento del riesgo de un nuevo evento de luxación. Por ende, resulta fundamental que los cirujanos ortopédicos comprendan y diagnostiquen estas lesiones de forma correcta y oportuna para evaluar la necesidad de restaurar la superficie articular glenoidea. El objetivo de esta revisión narrativa es otorgar los conceptos más importantes de la lesión ósea de Bankart para comprender y enfrentar de forma adecuada esta lesión.


Bony lesions of the anterior glenoid rim secondary to an episode of anterior instability of the shoulder are increasingly being reported. Known as a bony Bankart lesion, its presence generates a loss of static glenohumeral stability that causes an increased risk of a new dislocation event. Therefore, it is essential that orthopedic surgeons correctly and accurately diagnose these injuries to assess the need to restore the glenoid articular surface. The purpose of the present narrative review is to provide the essential concepts of the bony Bankart lesion to properly understand and deal with this type of injury.


Assuntos
Humanos , Lesões de Bankart/cirurgia , Lesões de Bankart/diagnóstico , Artroscopia/métodos , Recidiva , Luxação do Ombro
4.
Chinese Medical Journal ; (24): 2559-2564, 2019.
Artigo em Inglês | WPRIM | ID: wpr-803148

RESUMO

Background@#The size of the glenoid bone defect is an important index in selecting the appropriate treatment for anterior shoulder instability. However, the reliability of glenoid bone defect measurement is controversial. The purpose of the present study was to investigate the reliabilities of measurements of the glenoid bone defect on computed tomography and to explore the predisposing factors leading to inconsistency of these measurements.@*Methods@#The study population comprised 69 consecutive patients who underwent surgery for recurrent anterior shoulder dislocation in Peking University Fourth School of Clinical Medicine from March 2016 to January 2017. The glenoid bone defect was measured by three surgeons on 'self-confirmed’ and 'designated’ 3-D en-face views, and repeated after an interval of 3 months. Measurements included the ratio of the defect area to the best-fit circle area, and the ratio of the defect width to the diameter of the best-fit circle. The inter- and intra-observer reliabilities of the measurements were evaluated using intraclass correlation coefficients (ICCs). The maximum absolute inter- and intra-observer differences and the cumulative percentages of cases with inter- and intraobserver differences greater than these respective levels were calculated.@*Results@#Almost all linear defect values were bigger than the areal defect values. The inter-observer ICCs for the areal defect were 0.557 and 0.513 in the 'self-confirmed’ group and 0.549 and 0.431 in the 'designated’ group. The inter-observer reliabilities for the linear defect were moderate or fair in the 'self-confirmed’ group (ICC = 0.446, 0.374) and 'designated’ group (ICC = 0.402, 0.327). The ICCs for intra-observer measurements were higher than those for inter-observer measurements. The respective maximum interand intra-observer absolute differences were 13.9% and 13.2% in the 'self-confirmed’ group, and 15.8% and 9.8% in the 'designated’ group.@*Conclusions@#The areal measurement of the glenoid bone defect is more reliable than the linear measurement. The reliability of the glenoid defect areal measurement is moderate or worse, suggesting that a more accurate and objective measurement method is needed in both en-face view and best-fit circle determination. Subjective factors affecting the glenoid bone loss measurement should be minimized.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA