Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 332
Filtrar
1.
International Eye Science ; (12): 260-263, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1005392

RESUMO

With the rapid development of science and technology and the wide application of electronic products, the number of patients with high myopia is gradually increasing. Meanwhile, owing to the continuous optimization of surgical skils and the continuous advancement in materials of posterior chamber intraocular lens and manufacturing processes, implantable collamer lens(ICL)V4c implantation has gradually become one of the main surgeries for the treatment of high myopia. In the rapid era of social information, people pay more attention to the long-term efficacy after ICL V4c implantation, they not only want clear vision, but also the pursuit of visual comfort and durability. Therefore, this paper will specifically discuss the research progress of the post-implantation efficacy of ICL V4c with at least 2 a of follow-up observation within 3 a, aiming to review the latest research progress on the long-term efficacy of ICL V4c implantation from the three dimensions of visual quality, safety, efficacy and stability and possible surgical complications after ICL V4c implantation.

2.
International Eye Science ; (12): 48-52, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1003504

RESUMO

The foveal avascular zone(FAZ)is the most sensitive region of the retina, which is interconnected by the macular capillary plexus. Its morphology can indirectly reflect the alterations of macular microcirculation. With strong repeatability and reliability, optical coherence tomography angiography(OCTA)can non-invasively visualize and quantify the FAZ. The great value of OCTA makes it an important supplemental examination tool in ophthalmology and other professions. The area and perimeter of FAZ have been demonstrated to be an effective clinical diagnostic indicator in high myopia, diabetic retinopathy, glaucoma and other ocular diseases. In recent years, the geometry of FAZ has also proven to have clinical value. The parameters describing the geometry of FAZ, such as circularity index, acircularity index and axial ratio, provide a new perspective for ocular disease research. The comprehensive investigation of the morphological characteristics of the FAZ is helpful to explore the pathological mechanism of the occurrence and development of ocular diseases, predict preclinical changes, make pathological stages of the disease precise, and provide a theoretical basis for monitoring the disease's progression and assessing patients' visual prognosis.

3.
International Eye Science ; (12): 5-9, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1003497

RESUMO

AIM: To evaluate the pathogenic variants of the SCO2(OMIM 604272)gene in patients with high myopia from Enshi Tujia and Miao Autonomous Prefecture of China.METHODS: A total of 384 patients with high myopia whose spherical refractive error was ≤ -6.00 D and whose axial length was ≥26.00 mm in at least one eye were recruited. DNA was extracted by the phenol-chloroform method from 5 mL of peripheral venous blood. Sanger sequencing was performed to identify pathogenic variants in exon 2 of SCO2. The detected variants were evaluated via in silico prediction software. A total of 288 people from the same district were included as the normal control cohort.RESULTS: Seven variants were detected, namely, four synonymous variants(c.201C>T/p.=, c.576C>T/p.=, c.633A>C/p.=, c.780T>C/p.=.), two missense variants(c.187A>G/p.Ile63Val, c.59G>C/p.Arg20Pro)and one nonsense variant(c.544C>T/p.Gln182*). The two missense variants were not damaging, as predicted by PolyPhen2, SIFT and Provean. The novel nonsense variant(c.544C>T/p.Gln182*)cannot be found in the 1000 Genomes Project and was not identified in 288 normal controls. Variant Taster suggested that the nonsense variant site was conserved.CONCLUSION: The newly identified nonsense mutation may be responsible for high myopia of the patients in our cohort. SCO2 is associated with high myopia, while the incidence of SCO2 variants in high myopia in this cohort was as low as 1/384; the nonsense mutation may be a scarce variant of high myopia in the Enshi Tujia and Miao Autonomous Prefecture of China.

4.
International Eye Science ; (12): 805-809, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1016600

RESUMO

AIM: To compare the outcome of C3F8 versus silicone oil tamponade after pars plana vitrectomy(PPV)and inverted internal limiting membrane(ILM)for the treatment of highly myopic macular hole retinal detachment(MHRD).METHODS: Retrospective clinical study. Totally 45 patients(45 eyes)with highly myopic MHRD who visited our hospital between January 2019 and August 2022 were selected as the research subjects. The patients were divided into two groups according to different intraocular tamponade agents: C3F8(22 eyes)and silicone oil(23 eyes)groups. All patients underwent conventional three-incision PPV, ILM was tamped, a venous blood clot was placed on the tamped ILM, and 15% C3F8 and silicone oil were used as tamponade, respectively. The best corrected visual acuity(BCVA), multifocal electroretinogram(mfERG), the closure of the macular hole, retinal reattachment and the complications were observed.RESULTS: The macular hole closure rate was 77% in the C3F8 group and 83% in the silicone oil group, respectively(P>0.05), and retinal reattachment rates were 95% and 96%, respectively(P>0.05). The visual acuity of the two groups significantly improved, which was 0.99±0.34 and 1.22±0.37, respectively, and the C3F8 group was better than that of the silicone oil group(t=-2.156, P=0.037). After operation, the response density of the first ring of P1 wave in the first order kernel in mfERG was 114.27±26.37 nV/deg2 for the C3F8 group and 98.08±24.36 nV/deg2 for the silicone oil group, and the response density of the second ring of P1 wave was 80.45±14.94 nV/deg2 for the C3F8 group and 67.73±15.33 nV/deg2 for the silicone oil group, all of which were significantly higher compared to pre-operation [the response density of the first ring of P1 wave: 58.13±13.96 nV/deg2 for the C3F8 group and 55.30±10.48 nV/deg2 for the silicone oil group, the response density of the second ring of P1 wave: 51.18±8.19 nV/deg2 for the C3F8 group and 47.43±11.97 nV/deg2 for the silicone oil group](all P<0.05). It was found that the response density of the first ring of P1 wave was lower in the silicone oil group than in the C3F8 group(P<0.05). There was no statistically significant difference in the incidence of complications between the two groups(P>0.05).CONCLUSION: Silicone oil tamponade or C3F8 tamponade after PPV combined with ILM can both promote retinal reattachment and macular hole closure in patients with MHRD, and the C3F8 tamponade was superior to silicone oil in visual function recovery.

5.
International Eye Science ; (12): 641-645, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1012836

RESUMO

AIM: To evaluate the accuracy of the formulas, including Haigis, SRK/T, Holladay 1, and Holladay 2, in predicting the diopter of the intraocular lens implanted in high myopia cataract patients.METHODS: Prospective study. A total of 168 cases(168 eyes)of age-related cataract with an axial length(AL)≥26 mm who were treated in our hospital from August 2017 to November 2021 were selected. According to the preoperative AL measured by IOL Master 700, the patients were divided into five groups, including 37 cases(37 eyes)in group A with 26 mm≤AL<27 mm, 34 cases(34 eyes)in group B with 27 mm≤AL<28 mm, 42 cases(42 eyes)in group C with 28 mm≤AL<29 mm, 28 cases(28 eyes)in group D with 29 mm≤AL<30 mm, and 27 patients(27 eyes)in group E with AL ≥ 30 mm. Subjective refraction was performed at 3 mo postoperatively, and the mean numerical error(MNE)and mean absolute error(MAE)of each formula for predicting diopters were calculated.RESULTS: The MNE and MAE of the Haigis and Holladay 2 formulas were relatively less in each group, and MNE and MAE did not significantly increase with the growth of the axial length. However, the MAE and MNE of the SRK/T and Holladay 1 formulas significantly increased with the growth of the axial length, with the MNE and MAE of the Holladay 1 formula increasing more significantly in groups C, D, and E.CONCLUSION: For patients with age-related cataract, with an axial length of ≥26 mm, the accuracy of predicting the diopter of the intraocular lens using the Haigis and Holladay 2 formulas were higher.

6.
International Eye Science ; (12): 634-640, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1012835

RESUMO

AIM: To evaluate the binocular visual function in high myopia patients after the implantation of implantable collamer lens(ICL)V4c.METHODS: A total of 35 cases(70 eyes)that received binocular ICL implantation at our hospital from May 2019 to May 2021 were enrolled in this prospective study. Binocular full-range visual acuity, contrast sensitivity, stereopsis, mesopic vision and glare sensitivity, and monocular wavefront and the quality of vision questionnaire were assessed before the surgery and at 1 mo postoperatively.RESULTS: At 1 mo postoperatively, 35 cases(100%)had binocular uncorrected distance visual acuity(UDVA)≤0.00(LogMAR), 16 cases(46%)had binocular UDVA≥preoperative corrected distance visual acuity(CDVA). Binocular UDVA and uncorrected intermediate visual acuity(UIVA,80 cm)were improved compared to preoperative CDVA and distance-corrected intermediate visual acuity(DCIVA,80 cm)(all P<0.05).While there were no differences in the binocular postoperative UIVA(60 cm)and preoperative DCIVA(60 cm),and uncorrected near visual acuity(UNVA,40 cm)and preoperative distance-corrected near visual acuity(DCNVA,40 cm)(all P>0.05). The binocular contrast sensitivity was significantly improved postoperatively(P=0.001), and the postoperative binocular mesopic vision, glare sensitivity(no glare/glare)and binocular stereopsis(5 m/40 cm)had no differences(all P>0.05). The postoperative total higher-order aberration, trefoil aberration, coma and spherical aberration were increased, besides the median of total coma in the right eye with a pupil diameter of 3.0 mm was decreased after surgery. The mean total score of quality of vision questionnaire was significantly increased from 54.87 preoperatively to 80.92 after implantation(P<0.05), with high satisfaction and no obvious visual disturbance in patients.CONCLUSION: Although the monocular high-order aberrations increased in the early stage after ICL V4c binocular implantation in patients with high myopia, the binocular visual function was improved.

7.
International Eye Science ; (12): 612-617, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1012831

RESUMO

AIM:To compare the differences, correlations and consistency of IOL Master 700 or Lenstar LS900 in preoperative ocular biometry and the accuracy of intraocular lens(IOL)degree calculation of cataract patients with high myopia.METHODS: Retrospective study. A total of 136 cases(136 eyes)of high myopia and cataract patients who underwent phacoemulsification at the ophthalmology department of Army Medical Center of PLA from March 2021 to March 2023 were collected, with a mean age of 57.38±8.08 years. Patients were divided into 3 groups based on axial length(AL): 41 eyes in group A(26 mm≤ AL ≤28 mm), 43 eyes in group B(28 mm< AL ≤30 mm)and 52 eyes in group C(AL >30 mm). AL, mean keratometry(Km), anterior chamber depth(ACD), lens thickness(LT)and white-to-white(WTW)were preoperatively measured by two instruments, respectively. Barrett Universal II formula was used to calculate the IOL degrees of all patients, the appropriate reserved diopter was decided individually, and the prediction error(PE)and absolute error(AE)of the two instruments were compared.RESULTS:The AL and ACD of patients in the three groups measured by Lenstar LS900 were higher than the AL measurd by IOL Master 700(all P<0.05), with a difference of AL measured by the two devices: group C>group B>group A. However, there was no statistical significance in LT, Km, and WTW measured by the two instruments(all P>0.05). All biometric parameters measured by the two devices were positively correlated(all r>0.9, P<0.05), and consistent(95% LoA of all groups were narrow). There was no statistically significant difference in AE calculated by the two devices(P>0.05), but the IOL Master 700 calculated a smaller PE than Lenstar LS900(P<0.05), with lower percentage of hyperopic shift in IOL Master 700.CONCLUSION:In cataract patients with high myopia, AL measured by Lenstar LS900 is longer than that by IOL Master 700, and the differences of AL increase along with the growth of AL. Both devices have a good prediction for IOL calculation, but IOL Master 700 has less refractive error, lower percentage of hyperopic shift, and greater clinical advantages IOL Master 700.

8.
International Eye Science ; (12): 491-494, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1011407

RESUMO

AIM: To study the early outcomes of anterior segment parameters after implantation of an implantable collamer lens with a central hole(ICL V4c)in patients with high myopia.METHODS:A total of 82 cases(160 eyes)with high myopia, including 42 males(82 eyes)and 40 females(78 eyes), aged 26.0±4.6(21 to 37)years, who underwent ICL V4c implantation at our institution from February 2019 to September 2022 and were followed up for 1 a, were included. The general characteristics of the anterior segment of the eye were measured preoperatively: spherical equivalent, mean horizontal corneal curvature, white-to-white(WTW), and axial length(AL); intraocular pressure(IOP), endothelial cell density(ECD), central anterior chamber depth(CACD), anterior chamber volume(ACV)and anterior chamber angle(ACA)were measured preoperatively and at 1 d, 1 wk, 1, 3 and 6 mo postoperatively. Furthermore, the distance from the centre of the posterior surface of the ICL V4c optical zone to the anterior surface of the lens(vault)was measured at 1 d, 1 wk, 1, 6 mo, and 1 a after surgery.RESULTS: The mean preoperative spherical equivalent of the patients was -7.56±2.55 D, mean horizontal corneal curvature was 42.89±1.47 D, WTW was 11.64±0.37 mm, and AL was 26.64±0.93 mm. The baseline IOP was 15.97±2.13 mmHg, and the differences in IOP at each time point after ICL V4c implantation compared to preoperative were not statistically significant(F=0.875, P=0.504); ECD was 2 989.30±140.78 cells/mm2 at baseline, and ECD at 6 mo after ICL V4c implantation was not statistically significant compared with preoperative ECD(t=1.475, P=0.142); CACD was 3.19±0.21 mm at baseline, and ACV was 210.30±27.7 mm3, and CACD and ACV were significantly lower than preoperative at all postoperative time points(F=111.10, 288.38, all P<0.001). The baseline ACA was 35.44°±11.27°, and the ACA at each time point after ICL V4c implantation was significantly lower than preoperatively(F=21.23, P<0.001). The vault was 665.32±184.03 μm at 1 d postoperatively, and continued to be significantly reduced at 1 wk, 1, 6 mo, and 1 a postoperatively compared with 1 d(F=52.10, P<0.001). However, it remained stable at 6 mo and 1 a postoperatively, and the difference was not statistically significant compared with vault at 1 mo postoperatively(P>0.05).CONCLUSION: ICL V4c has certain safety and efficiency in 1 a postoperative follow-up, and the parameters of the anterior segment of the eye stabilized in the early period.

9.
International Eye Science ; (12): 432-435, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1011396

RESUMO

AIM: To observe the efficacy of phacoemulsification combined with capsular tension ring and intraocular lens implantation in the treatment of high myopia with cataract.METHODS: Retrospective study. A total of 82 cases(82 eyes)of high myopia complicated with cataract who admitted to the cataract department of our hospital from December 2021 to April 2023 were selected as study objects, and they were divided into control group(n=39)and combination group(n=43)according to whether or not the capsular tension ring was used intraoperatively. Patients in the control group were treated with intraocular lens implantation alone, and those in the combination group were treated with phacoemulsification combined with capsular tension ring and intraocular lens implantation. The preoperative and postoperative best corrected visual acuity, central anterior chamber depth, trabecular ciliary process, visual quality and complications were compared.RESULTS: At 1 mo after surgery, the best corrected visual acuity(LogMAR)of both groups increased significantly(combination group: 0.64±0.28 vs 0.12±0.14; control group: 0.62±0.26 vs 0.23±0.25, both P<0.001). Central anterior chamber depth in both groups were higher than those before surgery(combination group: 2.57±0.56 vs 1.97±0.40 mm; control group: 2.22±0.45 vs 1.89±0.37 mm; both P<0.001), and the best corrected visual acuity and central anterior chamber depth of the combination group were significantly better than those of the control group(both P<0.05). The distance of trabecular ciliary process showed no statistical significance(combination group: 0.68±0.22 vs 0.74±0.20 mm; control group: 0.74±0.19 vs 0.78±0.17 mm, both P>0.05). The visual quality scores of the combination group were all higher than the control group at 1 mo after surgery [watching TV: 3.00±0.38 vs 2.22±0.46 points; reading books: 2.85±0.42 vs 2.21±0.44 points; night vision: 2.71±0.34 vs 2.37±0.41 points; fine operation: 2.82±0.38 vs 2.33±0.40 points, all P<0.001]. The incidence of complication in the combination group was significantly lower than that of the control group(33% vs 14%, P<0.05).CONCLUSION: Phacoemulsification combined with capsular tension ring and intraocular lens implantation can effectively promote the recovery of visual function, improve the structure of chamber angle, and reduce the incidence of complications in the treatment of patients with high myopia and cataract.

10.
International Eye Science ; (12): 640-643, 2023.
Artigo em Chinês | WPRIM | ID: wpr-965792

RESUMO

AIM: To investigate the clinical efficacy of pars plana vitrectomy(PPV)combined with inverted internal limiting membrane flap technique in the treatment of macular hole retinal detachment(MHRD)in high myopia.METHODS: A retrospective clinical study was conducted. A total of 63 patients(64 eyes)with high myopia and MHRD who treated at our hospital from October 2017 to October 2021 were selected as research subjects. They were divided into two groups according to different surgery, with 34 cases(35 eyes)who received PPV combined with inverted internal limiting membrane flap technique in group A, and 29 cases(29 eyes)received PPV combined with internal limiting membrane peeling in group B. The patients were followed up for 6mo. The two groups were compared in terms of the hole closure rate, the reduction rate of retinal detachment and best corrected visual acuity(BCVA)before operation and at 1wk, 1, 3 and 6mo after operation, and the postoperative complications were recorded.RESULTS: The hole closure rate within 6mo after operation was significantly higher in group A than in group B(P<0.05), but there was no statistically significant difference in the reduction rate of retinal detachment(P>0.05). The BCVA of the two groups was significantly improved over time after operation(P<0.05). There was no statistically significant difference in BCVA between the two groups before operation and at 1wk, 1, 3 and 6mo after operation(P>0.05). Complications were observed in the two groups, but there was no statistically significant difference in the incidence of complications between the two groups(P<0.05).CONCLUSION: PPV combined with inverted internal limiting membrane flap technique is safe and effective in the treatment of MHRD in high myopia, which can effectively improve the patients' BCVA and the hole closure rate without influence on intraocular pressure.

11.
International Eye Science ; (12): 612-615, 2023.
Artigo em Chinês | WPRIM | ID: wpr-965787

RESUMO

Myopia is a harmful ophthalmic disease that may change the activity of the visual cortex and affect the corresponding neural function. At present, the incidence rate of myopia in China has been rising unprecedentedly, especially in high myopia(HM). Therefore, efficacious prevention and treatment of myopia are extremely important. However, since the specific pathogenesis of myopia has not been clarified so far, it is difficult to achieve the prevention and control of the disease at its source. Recently, there have been studies on the pathogenesis of myopia from the perspective of genetics, environment, neurotransmitters, etc., but few studies have explored the neuroimaging mechanism of myopia from the perspective of brain structure and function. With the development of magnetic resonance imaging(MRI)technology, brain images gradually appear in the study of myopia-related mechanisms. Therefore, this paper summarizes the research on myopia-related brain images, to provide an important reference for the clinical prevention and control of myopia.

12.
International Eye Science ; (12): 597-601, 2023.
Artigo em Chinês | WPRIM | ID: wpr-965784

RESUMO

High myopia is a state of refractive error with myopia over -6.00D. High myopia is typically accompanied by multiple fundus lesions, thus making patients with high myopia suffer from varying degrees of impairment in visual function. As an emerging auxiliary way in ophthalmology, optical coherence tomography angiography(OCTA)can efficiently and non-invasively obtain microvascular stratified images of the retina and choroid and quantitatively analyze blood flow signals. Since the advent of OCTA, there have been numerous studies observing fundus changes in those with high myopia through OCTA. In this paper, some studies in which OCTA is applied to obtain retinal and choroidal thickness from patients with high myopia are reviewed, with a view to revealing the correlation between high myopia and the parameters such as retinal thickness, choroidal thickness, vessel density and the area of the foveal avascular zone and providing novel ideas to deeply investigate the mechanism of high myopia and delay the occurrence and development of high myopia.

13.
International Eye Science ; (12): 462-465, 2023.
Artigo em Chinês | WPRIM | ID: wpr-964249

RESUMO

AIM: To evaluate the accuracy of SRK/T, Haigis, Barrett Universal II and Wang-Koch modified SRK/T formula in the operation of cataract complicated by super-high myopia.METHODS: A total of 44 cases(52 eyes)with super-high myopia complicated with cataract who underwent phacoemulsification with tension ring implantation combined with intraocular lens implantation in our hospital from January 2020 to June 2021 were collected. SRK/T, Haigis, Barrett Universal Ⅱ formula and Wang-Koch modified SRK/T formula were used to calculate the postoperative reserved diopter before surgery, and the actual diopter was measured by comprehensive optometry at 3mo after surgery. The mean absolute refractive error(MAE)of four formulas was obtained to evaluate the accuracy of the calculation formula.RESULTS: The MAE of SRK/T formula, Haigis formula, Barrett Universal Ⅱ formula and Wang-Koch modified SRK/T formula were 0.86(0.56, 1.20), 0.79(0.56, 1.16), 0.68(0.30, 0.87), 0.65(0.43, 0.75)D, respectively, and MAE of SRK/T formula and Haigis formula were significantly higher than those of Barrett Universal Ⅱ formula and Wang-Koch modified SRK/T formula(P<0.01). According to preoperative corneal curvature(K), enrolled patients were divided into K >46D group(12 eyes), 44D< K ≤46D group(24 eyes), and K ≤44D group(16 eyes). The MAE of SRK/T formula and Haigis formula were significantly higher than those of Barrett Universal Ⅱ formula and Wang-Koch modified SRK/T formula in the three groups(P<0.01). According to preoperative axial length(AL), patients were divided into AL ≤30 mm group(24 eyes)and AL >30mm group(28 eyes). The MAE of SRK/T formula and Haigis formula in two groups were significantly higher than those of Barrett Universal Ⅱ formula and Wang-Koch modified SRK/T formula(P<0.05).CONCLUSIONS: Wang-Koch modified SRK/T formula and Barrett Universal Ⅱ formula are more accurate in predicting the degree of intraocular lens in patients with super-high myopia complicated with cataract.

14.
International Eye Science ; (12): 456-461, 2023.
Artigo em Chinês | WPRIM | ID: wpr-964248

RESUMO

AIM: To evaluate the visual quality of patients with high myopia and cataract who received micro binocular single vision implantation of Tecnis Symfony intraocular lens(IOL), hybrid implantation of Tecnis Symfony IOL and Tecnis ZMB00 multifocal IOL, and binocular implantation of AcrySof IQ Panoptix IOL.METHODS: A prospective non-randomized controlled study was conducted to select patients with high myopia and cataract who underwent phacoemulsification combined with IOL implantation in the First Affiliated Hospital of Baotou Medical College from August 2020 to March 2022. According to the different IOL implantation schemes selected by patients, they are divided into micro single vision group, hybrid group and trifocal group. The postoperative follow-up was 3mo. The observation indexes included uncorrected far(5m), middle(80, 60cm)and near(33cm)visual acuity at 3mo after operation, contrast sensitivity(CS), uncorrected defocus curve under far vision, subjective visual quality score and light interference at 1 and 3mo after operation.RESULTS: There was no significant difference among the three groups in uncorrected far(5m)and middle(60cm)visual acuity at 3mo after operation(P<0.05); Uncorrected middle(80cm)distance visual acuity in the micro single vision group was similar to that in the hybrid group, and both were better than that in the trifocal group(P<0.05); Uncorrected near(33cm)distance vision of the hybrid group showed the best, followed by the trifocal group, and the lowest was in the micro single vision group(all P<0.05). The CS of dark light plus glare(12, 18c/d)was the best in the trifocal group, followed by the hybrid group, and the lowest was in the micro single vision group(all P<0.05). The defocus curve at 3mo after operation showed a span of +1.00~-3.00D, and the visual acuity of the three groups was better than 0.3 LogMAR; In the span of -1.00~-1.25D, the visual acuity of the hybrid group and micro single vision group was better than that of the trifocal group(all P<0.05); In the span of -3.00~-3.50D, the visual acuity of the hybrid group was the best, followed by trifocal group, and the lowest was in the micro single vision group(all P<0.05). At 3mo after operation, there was no significant difference in subjective visual quality scores among the three groups(P<0.05). Light interference in the micro single vision group was higher than that of the other two groups at 1mo after operation(P<0.05), and it decreased in the three groups at 3mo after operation, with no statistical significance(P<0.05).CONCLUSION: The three IOL implantation schemes can provide excellent visual quality for patients with high myopia and cataract. The vision of the micro single vision group and the hybrid group is better in the span of -1.00~-1.25D, and the hybrid group performs the best near vision in the span of -3.00~-3.50D. Although the design of micro single vision can make up for the weakness of Symfony IOL's lack of near vision, it is still worse than the hybrid group and the trifocal group.

15.
International Eye Science ; (12): 435-438, 2023.
Artigo em Chinês | WPRIM | ID: wpr-964244

RESUMO

With the prevalence of myopia in Asia, the prevalence of high myopia is gradually increasing, and high myopia has undoubtedly become a public health problem in Asia and even around the globe. As a relatively common pathological change in the eyes of patients with high myopia, optic disc tilt may also become a risk factor for diseases such as glaucoma and macular degeneration, thereby increasing the risk of visual impairment. However, the mechanism of optic disc tilt in high myopia and the role of optic disc tilt in the aggravation of high myopia complications still needs to be further explored. Therefore, this article collects and organizes relevant literatures on optic disc tilt, and makes a comprehensive discussion on the mechanism of optic disc shape changing caused by high myopia and the impact on various complications, so as to provide a certain basis for clinical diagnosis and treatment of high myopia and its complications.

16.
International Eye Science ; (12): 345-348, 2023.
Artigo em Chinês | WPRIM | ID: wpr-960964

RESUMO

AIM: To observe the efficacy of moderate and high myopia patients with vault greater than 1 000μm after implantation of phakic posterior chamber implantable contact lens(ICL).METHODS: A total of 42 patients(73 eyes)who received ICL implantation in the hospital and had postoperative vault greater than 1 000 μm between January 2014 and January 2017 were selected and retrospectively studied. Changes in visual acuity, intraocular pressure, corneal endothelial cell density, anterior chamber-related parameters(chamber angle, central anterior chamber depth, anterior chamber volume)and vault were compared among patients before surgery, at 1, 3, 6mo and 1a after surgery and at the last follow-up.RESULTS: The uncorrected visual acuity(UCVA)at 1, 3, 6mo and 1a after surgery and at the last follow-up was better than that before surgery(all P&#x0026;#x003C;0.05), and the chamber angle, central anterior chamber depth and anterior chamber volume were smaller or lower than those before surgery(all P&#x0026;#x003C;0.05), but there were no statistical differences in UCVA, chamber angle, central anterior chamber depth and anterior chamber volume at each time point after surgery(all P&#x0026;#x003E;0.05). The intraocular pressure at 1mo after surgery was lower than that before surgery(P&#x0026;#x003C;0.05), but the intraocular pressure at 3, 6mo and 1a after surgery and at the last follow-up was not statistically different from that before surgery(all P&#x0026;#x003E;0.05). There was no statistical significance in the corneal endothelial cell density at 1, 3, 6mo and 1a after surgery and at the last follow-up compared with that before surgery(all P&#x0026;#x003E;0.05). The vault at 1, 3, 6mo and 1a after surgery and at the last follow-up showed a decreasing trend, and the difference was statistically significant at each time point after surgery(all P&#x0026;#x003C;0.05).CONCLUSION: The short-term and long-term efficacy are better in moderate and high myopia patients with vault greater than 1 000 μm after ICL implantation, and there are no significant effects on the intraocular pressure and corneal endothelial cell. The postoperative anterior chamber structure is relatively stable and the vault tends to decrease over time. In most cases, close observation is sufficient and intraocular lens replacement is generally not required.

17.
International Eye Science ; (12): 325-328, 2023.
Artigo em Chinês | WPRIM | ID: wpr-960960

RESUMO

AIM: To measure the indexes including postoperative distance, middle, near visual acuity and near stereopsis vision of patients with high myopia cataract and corneal astigmatism by femtosecond laser, which can quantify the diameter of capsulorhexis opening, and to evaluate the availability and necessity of Toric intraocular lenses(IOL)in high myopia.METHODS: Prospective case-control study. Patients with binocular high myopia cataract and corneal astigmatism who undergone femtosecond laser-assisted cataract surgery in our hospital were selected, and they were divided into two groups, with 20 cases(40 eyes)in group A(Toric IOL)and 20 cases(40 eyes)in group B(IQ IOL). Indexes, including preoperative corneal astigmatism and spherical equivalent and best-corrected distance visual acuity, uncorrected middle visual acuity, uncorrected near visual acuity, residual refractive astigmatism, near stereopsis acuity, total high-order aberration and total spherical aberration, were measured postoperatively at 7d, 1 and 3mo.RESULTS: The uncorrected middle and near visual acuity, Titmus near stereopsis acuity and residual astigmatism at 7d, 1 and 3mo after surgery were significantly improved in the Toric IOL group than the non-Toric group(all P&#x0026;#x003C;0.05). The dependence on glasses was reduced. The postoperative best-corrected distance visual acuity, total high-order aberration and total spherical aberration of the two groups showed no statistically significant differences(all P&#x0026;#x003E;0.05).CONCLUSIONS: The implantation of Toric IOL in patients with high myopia cataract and corneal astigmatism can effectively correct corneal astigmatism, improve postoperative uncorrected middle and near visual acuity and near stereopsis visual function, reduce postoperative dependence on glasses and enhance binocular stereopsis visual function.

18.
International Eye Science ; (12): 320-324, 2023.
Artigo em Chinês | WPRIM | ID: wpr-960959

RESUMO

AIM: To investigate the changes in anterior chamber depth(ACD), axial length(AL), and corneal curvature(K)after operation in patients with high axial myopia combined with cataract, and the effect on postoperative mean refractive error(MFE)by different surgical approaches.METHODS: A total of 126 patients(126 eyes)performed cataract combined with intraocular lens(IOL)implantation were selected and divided into 3 groups according to different surgical approaches and axial length. Group A included 42 patients(42 eyes)who had cataract combined with high myopia and were performed cataract phacoemulsification combined with IOL implantation; Group B included 42 patients(42 eyes)who had cataract combined with high myopia and underwent small incision cataract extracapsular extraction combined with IOL implantation; Group C included 42 patients(42 eyes)who had cataract with normal axial length and underwent cataract phacoemulsification combined with IOL implantation. Then, the ACD, AL, K value and visual acuity of the three groups at 1d before operation and 3mo after operation were measured, and statistical analysis was performed.RESULTS: The differences in the mean values of preoperative and postoperative changes in ACD(△ACD)and AL(△AL)between groups A and B showed no statistical significance. The differences in the mean values of △ACD and △AL between groups A and C and groups B and C were both statistically significant(both P&#x0026;#x003C;0.01). △ACD and △AL in all three groups showed positive correlation(rA=0.855, rB=0.856, rC=0.639, all P&#x0026;#x003C;0.05). Furthermore, preoperative AL, △AL, △ACD and MFE in all three groups showed positive correlation(rA=0.874, 0.877, 0.858, rB=0.875, 0.879, 0.858, rC=0.428, 0.766, 0.862, all P&#x0026;#x003C;0.05). The standardized regression coefficients of groups A and B were △AL&#x0026;#x003E;△ACD(1.32 and 1.31 times), and the standardized regression coefficients of group C were △ACD&#x0026;#x003E;△AL(1.66 times).CONCLUSION: Different surgical procedures had no significant effect on the postoperative K value and MFE in patients with high axial myopia combined with cataract, of which main influencing factor is the change in the AL before and after surgery. The postoperative MFE in patients with normal AL was more due to the change of ACD.

19.
International Eye Science ; (12): 212-216, 2023.
Artigo em Chinês | WPRIM | ID: wpr-960938

RESUMO

High myopia is the main cause of visual impairment in the world. With the development of society, the myopia rate is increasing year by year. The development of high myopia is closely related to the progressive extension of the eye axis, and a series of fundus changes will inevitably occur with the extension of the eye axis, such as comus, lacquer cracks, choroidal neovascularization, macular choroidal atrophy, retinal detachment, posterior scleral staphyloma, etc. At present, characterized by younger age and high degree, myopia has become the main cause of blindness in China. This paper briefly summarizes the latest research on the morphological changes of the optic disc, macula, retina, choroid and sclera of high myopia, aiming to provide references for the development of intelligent prediction models, clinical diagnosis and further research on the treatment measures in combination with the fundus morphology of high myopia.

20.
Chinese Journal of Ocular Fundus Diseases ; (6): 690-695, 2023.
Artigo em Chinês | WPRIM | ID: wpr-995684

RESUMO

High myopia has a high genetic tendency, it not only shows in the excessive elongation of the axial length, but also lends to the formation and progression of various eye lesions, such as peripheral retinopathy, optic disc changes, posterior staphyloma, and myopic maculopathy, due to the mechanical stretching of the axial length to the ocular structure. In addition, high myopia increases the risk of several complications, such as glaucoma, cataract, and corneal disease. All these pathological changes will affect visual function and lead to irreversible vision impairment and blindness in the future. Therefore, it is important to pay attention to screening for optic disc abnormalities and posterior staphyloma, and regular monitor the changes of fundus, intraocular pressure, and lens. At the same time, high myopia has an impact on personal life such as study, psychology, sport, and work, and can reduce the quality of life as well as increase the cost of health care. The clinic should pay more attention to high myopia, prevent and control the development of high myopia from an early stage, in order to minimize its impact on ocular structure and visual function as well as its hazard to personal life and society.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA