Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Assunto principal
Intervalo de ano
2.
Indian J Ophthalmol ; 2018 Nov; 66(11): 1600-1607
Artigo | IMSEAR | ID: sea-196960

RESUMO

Purpose: To describe the outcomes of a patient-specific implant (PSI), fabricated using a three-dimensional (3D) printed orbital template and placed in the basin of the inferior orbital fissure to correct inferotemporally migrated spherical orbital implant. Methods: This is a single-center, prospective, consecutive, interventional, case series of six patients, with non-porous, spherical, orbital implant migration that underwent implant recentration surgically with a novel technique. Migration was subclassified either as decentration that did not affect the prosthetic retention or as displacement that affected the prosthetic retention in the eye socket. Only implant displacements were treated. The primary outcome measure was centration of the implant clinically and radiologically, with ability to retain the prosthesis. Results: At a mean follow-up of 21 months, all six orbital spherical implants remained centered. There were no cases of extrusion, exposure, or migration of either implants. There were no cases of PSI displacement. Additional procedures to optimize the aesthetic outcome of the customized ocular prosthesis (COP) required were simultaneous fornix formation suture in three patients, subsequent fornix formation with mucus membrane graft in two patients, and levator resection and sulcus hyaluronic acid gel injection in one patient each. The mean PSI implant weight was 2.66 ± 0.53 g. The mean COP weight was 2.2 ± 0.88 g postoperatively. The median patient satisfaction with the procedure was 9 on 10. Conclusion: A 3D printing-assisted PSI placed in the basin of the inferior orbital fissure allows recentration of the migrated implant over a follow-up of 21 months without complications.

3.
Artigo em Inglês | WPRIM | ID: wpr-629506

RESUMO

Subluxation or dislocation of PCIOL is one of the complications of cataract operation in RP patients. This paper reports the presentation of PCIOL dislocation and subluxation and the management and outcome in 3 eyes of 2 RP patients. Two medical records of patients with RP who developed dislocated or subluxated PCIOL and subsequently underwent explantation of the dropped IOL were evaluated. Two patients had bilateral eye cataract operation done and had PCIOL implanted. Patient 1 developed left eye subluxated PCIOL inferiorly after 2 years of the cataract operation and right eye dislocated PCIOL anteriorly 4 years after cataract operation. Patient 2 develop right eye subluxated PCIOL inferiorly after 12 years of the cataract operation. Patient 1 with right eye dislocated PCIOL underwent intraocular lens (IOL) explantation and was left aphakic as her visual prognosis was poor due to advanced RP. The left IOL remained within the visual axis despite subluxation and no intervention has been done. Patient 2 with right eye subluxated PCIOL underwent IOL explantation and anterior chamber intraocular lens (ACIOL) implantation. ACIOL remained stable and visual acuity improved post-operation. Both the operations were uneventful. Post-operatively, there was no elevated intraocular pressure and no prolonged ocular inflammation, which required prolonged anti-inflammatory and no retinal detachment was seen. Both patient and surgeon should be aware of potential PCIOL subluxation or dislocation in RP. The presentation may be as late as more than a decade after the cataract operation.


Assuntos
Retinose Pigmentar
4.
Artigo em Coreano | WPRIM | ID: wpr-200471

RESUMO

The anatomic and physiologic changes of the anopthalmic orbit affect cosmetic appearance of the patient and function of the socket and the prosthesis. During the past three years, the authors studied 13 cases of dermis-fat graft and 27 cases of posterior Tenon's capsule suturing with a plastic implant, and compared the post'operative effects of the two procedures. Dermis-fat graft produced good fornix formation with no remarkable fat atrophy after both primary and secondary proceddure. Posterior Tenon's capsule suture technique showes good effect to keep implant from migration or extrusion. Size of the plastic implant and fixation of the extraocular muscles were important factors also for good cosmesis and implant motility. There revealed no significant difference between the two procedures in EOM motility, enophthalmos, deep superior sulcus deformity, implant migration or prolapse etc.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA