Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 434
Filtrar
1.
International Eye Science ; (12): 634-640, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1012835

RESUMO

AIM: To evaluate the binocular visual function in high myopia patients after the implantation of implantable collamer lens(ICL)V4c.METHODS: A total of 35 cases(70 eyes)that received binocular ICL implantation at our hospital from May 2019 to May 2021 were enrolled in this prospective study. Binocular full-range visual acuity, contrast sensitivity, stereopsis, mesopic vision and glare sensitivity, and monocular wavefront and the quality of vision questionnaire were assessed before the surgery and at 1 mo postoperatively.RESULTS: At 1 mo postoperatively, 35 cases(100%)had binocular uncorrected distance visual acuity(UDVA)≤0.00(LogMAR), 16 cases(46%)had binocular UDVA≥preoperative corrected distance visual acuity(CDVA). Binocular UDVA and uncorrected intermediate visual acuity(UIVA,80 cm)were improved compared to preoperative CDVA and distance-corrected intermediate visual acuity(DCIVA,80 cm)(all P<0.05).While there were no differences in the binocular postoperative UIVA(60 cm)and preoperative DCIVA(60 cm),and uncorrected near visual acuity(UNVA,40 cm)and preoperative distance-corrected near visual acuity(DCNVA,40 cm)(all P>0.05). The binocular contrast sensitivity was significantly improved postoperatively(P=0.001), and the postoperative binocular mesopic vision, glare sensitivity(no glare/glare)and binocular stereopsis(5 m/40 cm)had no differences(all P>0.05). The postoperative total higher-order aberration, trefoil aberration, coma and spherical aberration were increased, besides the median of total coma in the right eye with a pupil diameter of 3.0 mm was decreased after surgery. The mean total score of quality of vision questionnaire was significantly increased from 54.87 preoperatively to 80.92 after implantation(P<0.05), with high satisfaction and no obvious visual disturbance in patients.CONCLUSION: Although the monocular high-order aberrations increased in the early stage after ICL V4c binocular implantation in patients with high myopia, the binocular visual function was improved.

2.
International Eye Science ; (12): 491-494, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1011407

RESUMO

AIM: To study the early outcomes of anterior segment parameters after implantation of an implantable collamer lens with a central hole(ICL V4c)in patients with high myopia.METHODS:A total of 82 cases(160 eyes)with high myopia, including 42 males(82 eyes)and 40 females(78 eyes), aged 26.0±4.6(21 to 37)years, who underwent ICL V4c implantation at our institution from February 2019 to September 2022 and were followed up for 1 a, were included. The general characteristics of the anterior segment of the eye were measured preoperatively: spherical equivalent, mean horizontal corneal curvature, white-to-white(WTW), and axial length(AL); intraocular pressure(IOP), endothelial cell density(ECD), central anterior chamber depth(CACD), anterior chamber volume(ACV)and anterior chamber angle(ACA)were measured preoperatively and at 1 d, 1 wk, 1, 3 and 6 mo postoperatively. Furthermore, the distance from the centre of the posterior surface of the ICL V4c optical zone to the anterior surface of the lens(vault)was measured at 1 d, 1 wk, 1, 6 mo, and 1 a after surgery.RESULTS: The mean preoperative spherical equivalent of the patients was -7.56±2.55 D, mean horizontal corneal curvature was 42.89±1.47 D, WTW was 11.64±0.37 mm, and AL was 26.64±0.93 mm. The baseline IOP was 15.97±2.13 mmHg, and the differences in IOP at each time point after ICL V4c implantation compared to preoperative were not statistically significant(F=0.875, P=0.504); ECD was 2 989.30±140.78 cells/mm2 at baseline, and ECD at 6 mo after ICL V4c implantation was not statistically significant compared with preoperative ECD(t=1.475, P=0.142); CACD was 3.19±0.21 mm at baseline, and ACV was 210.30±27.7 mm3, and CACD and ACV were significantly lower than preoperative at all postoperative time points(F=111.10, 288.38, all P<0.001). The baseline ACA was 35.44°±11.27°, and the ACA at each time point after ICL V4c implantation was significantly lower than preoperatively(F=21.23, P<0.001). The vault was 665.32±184.03 μm at 1 d postoperatively, and continued to be significantly reduced at 1 wk, 1, 6 mo, and 1 a postoperatively compared with 1 d(F=52.10, P<0.001). However, it remained stable at 6 mo and 1 a postoperatively, and the difference was not statistically significant compared with vault at 1 mo postoperatively(P>0.05).CONCLUSION: ICL V4c has certain safety and efficiency in 1 a postoperative follow-up, and the parameters of the anterior segment of the eye stabilized in the early period.

3.
International Eye Science ; (12): 484-490, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1011406

RESUMO

AIM: To evaluate the clinical effect of toric implantable collamer lens(TICL)V4c for correcting moderate to high myopia with high astigmatism using vector analysis and quality of life impact of refractive correction(QIRC).METHODS: Retrospective case series. A total of 55 patients(90 eyes)with moderate to high myopia and high astigmatism who received TICL V4c implantation in the refraction surgery center of ophthalmology department in our hospital from January 2019 to December 2022 were collected. Followed-up for 1 a, the uncorrected distance visual acuity(UDVA), best corrected visual acuity(BCVA)and diopters were observed. Alpins vector analysis was used to evaluate the effect of astigmatism correction, and QIRC scale was used to evaluate patients' quality of life.RESULTS: At 1 a postoperatively, the UDVA of 98% eyes was the same or better than pre-operative BCVA, the safety index was 1.11±0.14, and the efficacy index was 1.11±0.15. The angle of error of 97% of the astigmatic eyes was within ±15°. The results of vector analysis showed that correction index was 0.83±0.13, angle of error was 1.00±4.49°, and index of success was 0.21±0.15. The total higher order aberrations under a pupil diameter of 6 mm was significantly increased compared with preoperatively(P<0.05), the QIRC score was significantly better than that before surgery(P<0.001), and the increase of total QIRC scores was positively correlated with preoperative spherical equivalent(rs=0.215, P<0.05), indicating that the higher degree of myopia before surgery the patients, the better the quality of life after TICL implantation.CONCLUSION: TICL V4c implantation for the correction of moderate to high myopia with high astigmatism is safe and effective, and the patients' quality of life significantly improved after surgery.

4.
International Eye Science ; (12): 260-263, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1005392

RESUMO

With the rapid development of science and technology and the wide application of electronic products, the number of patients with high myopia is gradually increasing. Meanwhile, owing to the continuous optimization of surgical skils and the continuous advancement in materials of posterior chamber intraocular lens and manufacturing processes, implantable collamer lens(ICL)V4c implantation has gradually become one of the main surgeries for the treatment of high myopia. In the rapid era of social information, people pay more attention to the long-term efficacy after ICL V4c implantation, they not only want clear vision, but also the pursuit of visual comfort and durability. Therefore, this paper will specifically discuss the research progress of the post-implantation efficacy of ICL V4c with at least 2 a of follow-up observation within 3 a, aiming to review the latest research progress on the long-term efficacy of ICL V4c implantation from the three dimensions of visual quality, safety, efficacy and stability and possible surgical complications after ICL V4c implantation.

5.
International Eye Science ; (12): 210-215, 2024.
Artigo em Chinês | WPRIM | ID: wpr-1005382

RESUMO

AIM: To compare the clinical efficacy, vault, and rotational stability of horizontal, oblique, and vertical implantation of Toric implantable collamer lens(TICL).METHODS: Retrospective cohort study. A total of 92 cases(120 eyes)who underwent TICL implantation from July 2018 to March 2022 and had regular follow-up for at least 1 a postoperatively(1 d, 1 wk, 1, 3, 6 mo, and 1 a)at Wuhan Bright Eye Hospital were collected. The patients were divided into three groups, with 34 cases(45 eyes)in horizontal implantation group, 25 cases(29 eyes)in oblique implantation group(29 cases), and 33 cases(46 eyes)in vertical implantation group. Uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA), diopters, vault, and rotation angle(deviation of the actual axis of TICL from the expected axis).RESULTS: All surgeries were uneventful, and there were no complications such as infection, secondary glaucoma, or cataract opacity. Safety and efficacy of the surgery: the CDVA of the three groups of patients was better than or equal to the preoperative CDVA at 1 a postoperatively, and there was no statistically significant differences in postoperative UDVA and CDVA of the three groups(P>0.05). The safety index at 1a postoperatively was 1.34±0.21, 1.34±0.17, and 1.31±0.18 for the horizontal, oblique, and vertical groups, respectively. The efficacy index was 1.26±0.21, 1.33±0.18, and 1.27±0.16 for the three groups, respectively, both with no statistically significant differences(P>0.05). Vault: there was a significant difference in postoperative vault among the three groups(P=0.003), with the vertical group having the lowest vault, followed by the horizontal group and the oblique group. The vaults at different follow-up time points within each group showed significant differences(P<0.001), and all decreased over time. Residual astigmatism: there was no significant difference in residual astigmatism among the three groups(P=0.130), but there were differences at different follow-up time points within each group(P<0.001). Rotation angle: no significant differences in rotation angle were observed among the three groups(P=0.135), but there were differences at different follow-up time points within each group(P<0.001).CONCLUSION: The implantation of TICL in different orientations has good safety and efficacy, the postoperative rotational stability is good, and the appropriate angle can be selected to implant TICL according to the clinical situation.

6.
Indian Heart J ; 2023 Apr; 75(2): 115-121
Artigo | IMSEAR | ID: sea-220968

RESUMO

Background & Objective: Despite the burden of sudden cardiac arrest (SCA) worldwide, implantable cardioverter-defibrillators (ICDs) are underutilized, particularly in Asia, Latin America, Eastern Europe, the Middle East, and Africa. The Improve SCA trial demonstrated that primary prevention (PP) patients in these regions benefit from an ICD or a cardiac resynchronization therapy defibrillator (CRT-D). We aimed to compare the rate of device therapy and mortality among ischemic and non-ischemic cardiomyopathy (ICM and NICM) PP patients who met guideline indications for ICD therapy and had an ICD/CRT-D implanted. Methods: Improve SCA was a prospective, non-randomized, non-blinded multicenter trial that enrolled patients from the above-mentioned regions. All-cause mortality and device therapy were examined by cardiomyopathy (ICM vs NICM) and implantation status. Cox proportional hazards methods were used, adjusting for factors affecting mortality risk. Results: Of 1848 PP NICM patients, 1007 (54.5%) received ICD/CRT-D, while 303 of 581 (52.1%) PP ICM patients received an ICD/CRT-D. The all-cause mortality rate at 3 years for NICM patients with and without an ICD/CRT-D was 13.1% and 18.3%, respectively (HR 0.51, 95% CI 0.38e0.68, p < 0.001). Similarly, all-cause mortality at 3 years in ICM patients was 13.8% in those with a device and 19.9% in those without an ICD/CRT-D (HR 0.54, 95% CI 0.33e.0.88, p ¼ 0.011). The time to first device therapy, time to first shock, and time to first antitachycardia pacing (ATP) therapy were not significantly different between groups (p 0.263). Conclusions: In this large data set of patients with a guideline-based PP ICD indication, defibrillator device implantation conferred a significant mortality benefit in both NICM and ICM patients. The rate of appropriate device therapy was also similar in both groups.

7.
Int. arch. otorhinolaryngol. (Impr.) ; 27(1): 43-49, Jan.-Mar. 2023. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1421685

RESUMO

Abstract Introduction Upper airway stimulation (UAS) with electric activation of the hypo-glossal nerve has emerged as a promising treatment for patients with moderate-to-severe obstructive sleep apnea. Objective To retrospectively analyze objective and subjective outcome measures after long-term follow-up in obstructive sleep apnea patients receiving upper airway stimulation. Methods An observational retrospective single-center cohort study including a consecutive series of patients diagnosed with obstructive sleep apnea receiving upper airway stimulation. Results Twenty-five patients were included. The total median apnea-hypopnea index (AHI) significantly decreased from 37.4 to 8.7 events per hour at the 12-month follow-up (p < 0.001). The surgical success rate was 96%. Adverse events were reported by 28% of the patients. Conclusion Upper airway stimulation is an effective and safe treatment for obstructive sleep apnea in patients with continuous positive airway pressure (CPAP) failure or intolerance. However, it is possible that the existing in and exclusion criteria for UAS therapy in the Netherlands have positively influenced our results.

8.
Chinese Journal of Medical Instrumentation ; (6): 550-556, 2023.
Artigo em Chinês | WPRIM | ID: wpr-1010237

RESUMO

In recent years, new orthopaedic implantable devices continue to emerge, which require higher requirements for technical evaluation. Animal study is an important part of the research and development process for the new orthopedic implantable devices, which provides relevant evidence for product design and stereotyping. By introducing the purpose of animal study, and the application of 3R principle (replacement, reduction, refinement) in this field, we summarize the concern on the animal study, in order to provide reference for the development and research of new orthopedic implantable devices and biomaterials. At the same time, the application of evidence-based research methods such as systematic review in the field is introduced, which provides new tools and approaches for the technical review and regulatory science.


Assuntos
Animais , Ortopedia , Materiais Biocompatíveis , Próteses e Implantes , Projetos de Pesquisa
9.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 1351-1354, 2023.
Artigo em Chinês | WPRIM | ID: wpr-996990

RESUMO

@#Implantable left ventricular assist device (LVAD) has become an essential treatment for end-stage heart failure, and its effect has been continuously improved. In the world, magnetic levitation LVAD has become mainstream and is increasingly used as a destination treatment. China has also entered the era of ventricular assist device. The continuous improvement of the ventricular assist device will further improve the treatment effect. This article reviews the current situation and development trend of LVAD treatment in China and abroad.

10.
Chinese Journal of General Practitioners ; (6): 187-193, 2023.
Artigo em Chinês | WPRIM | ID: wpr-994704

RESUMO

Objective:To explore the influencing factors and effectiveness of community follow-up in patients with cardiac implantable electronic device (CIED) implantation.Method:A total of 132 patients who received CIED implantation in the Department of Cardiology of Tongren Hospital, Shanghai Jiao Tong University School of Medicine from February 2021 to February 2022 were enrolled in this prospective cohort study. Among them 33 patients were followed up in community health service centers associated with Tongren Hospital (community follow-up group) and 99 matched patients were followed up in the CIED outpatient clinic of the hospital (outpatient follow-up group) with a ratio of 1∶3. The clinical data of the selected patients were collected through a questionnaire survey; the follow-up data were extracted through the CarelinkExpress electronic follow-up platform and the CIED outpatient information system of Tongren Hospital. Adjustment of the treatment protocol or CIED parameters at follow-up, and the referral from the community health service centers were defined as visit with-an-action (VWA). The endpoint of follow-up was the occurrence of major adverse events. The multivariate logistic regression model was used to analyze the factors influencing patient selection for community follow-up.Results:The univariate analysis showed that the frequency of visits to community health service centers and the service contracting rate in community follow-up group were higher than those of outpatient follow-up group ( P<0.05). The multivariate logistic regression analysis showed that the contracted community physician service was an independent influencing factor of patient choosing community follow-up ( OR=2.143, 95% CI: 1.103-4.166, P=0.025). A total of 469 visits of followed up occurred in 132 patients, including 45 community visits and 424 outpatient visits. VWA accounted for 22.2% (10/45) in the community follow-up group, and 17.2% (73/424) in the outpatient follow-up group ( P>0.05). There was no significant difference in the safety and effectiveness indicators (VWA, major adverse events, and unplanned follow-up) between the two groups ( P>0.05). More patients in the community follow-up group walked to the hospital than the outpatient follow-up group ( P<0.05);and the main transportation for the later was by bus or taxi(42(42.4%)or 41(41.4%)). The average waiting time in the community follow-up group was significantly shorter than that in outpatient follow-up group ( P<0.05). The total time required for a single follow-up in the community follow-up group was 50.0 (45.0, 59.5) minutes, which was significantly shorter than that in the routine outpatient follow-up group (107.0 (90.0, 135.0) minutes, P<0.05). Conclusions:The contracting with community physicians is an independent influencing factor for CIED implanted patients to choose community follow-up. The safety and effectiveness of community follow-up are comparable to routine outpatient follow-up, and community follow-up is more convenient.

11.
Chinese Journal of Pharmacology and Toxicology ; (6): 553-553, 2023.
Artigo em Chinês | WPRIM | ID: wpr-992222

RESUMO

Neural recording electrodes enable the acquisition and collection of electrical signals from neu-rons,and these recorded neural electrical signals are an important means of understanding neuronal activity.As a major component of the brain-machine interface,neu-ral recording electrodes serve as a bridge between the nervous system and external devices.The extracted information can be used to understand the state of the brain and acts as a feedback signal to regulate external devices,thus providing important information for the clini-cal treatment of neurological diseases.Moreover,the electrodes can be used as a vehicle for drug injection to directly treat diseases.Since the time that Strumwas-ser used microwires to achieve long-term recordings of neural activity in hibernating squirrels,implantable elec-trode technology has gradually improved over three gen-erations of development,and progress has been made in improving the biocompatibility,mechanical performance(size,shape,density,etc.),and signal-to-noise ratio.Implantable neural recording electrodes can acquire sig-nals from cortical and deep neural clusters,with the advantages of high signal-to-noise ratio,information con-tent,and spatial/temporal resolution.However,there is still a need to improve the structure and performance of these electrodes;for example,their high invasiveness and lack of biocompatibility pose technical difficulties in the process of translation to the clinic.This paper reviews the basic requirements for electrodes,main recording methods and signal types,common types of implant-able neural recording electrodes,and their challenges and future development directions.With the continuous development of electrode materials,equipment,systems,and neurotechnology,it should be possible to apply neu-ral recording electrodes in clinical practice,to promote safe and efficient treatment of human diseases.

12.
Chinese Journal of Practical Nursing ; (36): 1914-1921, 2023.
Artigo em Chinês | WPRIM | ID: wpr-990427

RESUMO

Objective:To systematically evaluate the risk factors of implantable venous access port-related bloodstream infections and provide basis for prevention of catheter-related bloodstream infection in tumor patients.Methods:The Cochrane Library, PubMed, EMBASE, Web of science, CNKI, Wanfang database, VIP database, CBM, Chinese and English Clinical trials Registry (ChiCTR) were searched to collect the literature on risk factors for implantable venous access port-related bloodstream infections in tumor patients from the establishment of the database to April 2022. Two evaluators independently screened and extracted the obtained literature according to the inclusion and exclusion criteria, and used the Newcastle-Ottawa Scale for quality evaluation. Meta-analysis was conducted by RevMan 5.3 software and Stata SE/MP(14.0 version).Results:A total of 13 studies were included, including 23 related risk factors. Among them, prolonged use of catheters, palliative treatment, hematological tumors, neutropenia, hospitalized patients, and chemotherapy were risk factors for implantable venous access port-related bloodstream infections in tumor patients, with statistically significant differences ( OR values ranging from 0.26 to 8.77, all P<0.05). Conclusions:The long time of catheter use, palliative treatment, hematological tumor, neutropenia and chemotherapy were the risk factors of implantable venous access port-related bloodstream infection in patients with tumor, Medical personnel should make a good assessment and strengthen health education to minimize the chances of infection and effectively reduce the incidence of infection related to the infusion port.

13.
Chinese Journal of Medical Instrumentation ; (6): 304-308, 2023.
Artigo em Chinês | WPRIM | ID: wpr-982233

RESUMO

Implanted brain-computer interface (iBCI) is a system that establishes a direct communication channel between human brain and computer or an external devices by implanted neural electrode. Because of the good functional extensibility, iBCI devices as a platform technology have the potential to bring benefit to people with nervous system disease and progress rapidly from fundamental neuroscience discoveries to translational applications and market access. In this report, the industrialization process of implanted neural regulation medical devices is reviewed, and the translational pathway of iBCI in clinical application is proposed. However, the Food and Drug Administration (FDA) regulations and guidances for iBCI were expounded as a breakthrough medical device. Furthermore, several iBCI products in the process of applying for medical device registration certificate were briefly introduced and compared recently. Due to the complexity of iBCI in clinical application, the translational applications and industrialization of iBCI as a medical device need the closely cooperation between regulatory departments, companies, universities, institutes and hospitals in the future.


Assuntos
Humanos , Interfaces Cérebro-Computador , Encéfalo/fisiologia , Eletrodos Implantados
14.
Journal of Zhejiang University. Medical sciences ; (6): 162-168, 2023.
Artigo em Inglês | WPRIM | ID: wpr-982031

RESUMO

Benign prostatic hyperplasia (BPH) is the most common cause of lower urinary tract symptoms in men. When drug treatment is ineffective or conventional surgery is not suitable, novel minimally invasive therapies can be considered. These include prostatic urethral lift, prostatic artery embolisation, water vapor thermal therapy, Aquablation-image guided robotic waterjet ablation, temporary implantable nitinol device and prostatic stents. These novel therapies can be performed in outpatient setting under local anesthesia, with shorter operative and recovery times, and better protection of ejaculatory function and erectile function. General conditions of the patient and advantages and disadvantages of the each of these therapies should be fully considered to make individualized plans.


Assuntos
Masculino , Humanos , Hiperplasia Prostática/complicações , Stents/efeitos adversos , Embolização Terapêutica/efeitos adversos , Sintomas do Trato Urinário Inferior/cirurgia , Resultado do Tratamento , Procedimentos Cirúrgicos Minimamente Invasivos
15.
China Pharmacy ; (12): 844-848, 2023.
Artigo em Chinês | WPRIM | ID: wpr-969582

RESUMO

OBJECTIVE To compare the safety of high-dose methotrexate (HD-MTX) via peripherally inserted central catheter (PICC) and totally implantable venous access port (TIVAP) in pediatric patients with malignant brain tumors. METHODS Patients with malignant brain tumors who received HD-MTX via PICCs or TIVAPs in our hospital from July 2018 to April 2022 were retrospectively analyzed. Clinical data were collected to compare differences in blood concentration of methotrexate (MTX),the incidence of adverse events (including adverse drug reactions and catheter-related complications) and length of stay in hospital. Multivariate linear regression was applied to analyze the factors that influenced the blood concentration of MTX. RESULTS A total of 107 patients were included in the study,with 65 patients in the PICC group and 42 patients in the TIVAP group. Blood concentration of MTX at 24 h (C24 h) in TIVAP group was significantly higher than PICC group ([ 126.87±61.99) μmol/L vs. (102.45±48.77) μmol/L,P<0.05). There was no significant difference in blood concentration of MTX at 42 h (C42 h),compared with PICC group (P>0.05). Results of multivariate linear regression analysis showed that TIVAP was associated with the increase of C24 h(P<0.05). No significant differences were observed in the incidence of adverse events and the length of stay in the hospital between 2 groups (P>0.05). CONCLUSIONS Risk of adverse events is not increased,although the MTX C24 h level is elevated after administration of TIVAP. TIVAP is a safe choice for HD-MTX therapy with implementing therapeutic drug monitoring.

16.
International Eye Science ; (12): 567-572, 2023.
Artigo em Chinês | WPRIM | ID: wpr-965778

RESUMO

AIM: To investigate the short-term visual quality outcomes after femtosecond laser small incision lenticule extraction(SMILE)and evolution implantable collamer lens(EVO-ICL)implantation for the correction of moderate myopia.METHODS: Prospective control study. A total of 51 cases(51 eyes)with moderate myopia who underwent SMILE or EVO-ICL implantation surgery at Weifang Eye Hospital from April 2021 to February 2022 were selected. They were divided into SMILE group(30 patients, 30 eyes)and EVO-ICL group(21 patients, 21 eyes)according to the surgical methods. The changes of visual acuity [uncorrected distance visual acuity(UDVA), corrected distance visual acuity(CDVA)], diopter [spherical equivalent(SE)] and related parameters of optical quality analysis system(OQAS Ⅱ)were observed before surgery and at 1wk, 1 and 3mo after surgery, and the quality of vision(QoV)questionnaire was completed.RESULTS: At 3mo after surgery, the safety index(postoperative CDVA/preoperative CDVA)of SMILE gruop and EVO-ICL group were 1.20(1.00, 1.20)and 1.20(1.00, 1.38), respectively, the efficacy index(postoperative UDVA/preoperative CDVA)were 1.00(1.00, 1.20)and 1.00(1.00, 1.20), respectively, and the percentage of SE within ±0.50D was 87% and 100%, respectively. In SMILE group, the objective scattering index(OSI)was increased after surgery, while modulation transfer function cutoff frequency(MTF cutoff), contrast visual acuity(VA)100%, and VA20% at 1wk and 1mo after surgery, and Strehl ratio(SR)and VA9% at each time point after surgery were all decreased compared with those before surgery(all P&#x0026;#x003C;0.05). The OSI, MTF cutoff, SR and VA of EVO-ICL group showed no difference at each time point after surgery compared with those before surgery(all P&#x0026;#x003E;0.05). The most common visual symptoms after SMILE and EVO-ICL implantation were visual haze and halos, respectively.CONCLUSION: Both SMILE and EVO-ICL implantation have good safety, efficacy and predictability in the short term after the correction of moderate myopia. Both groups had visual symptoms after surgery, but the overall satisfaction of patients was high. Furthermore, EVO-ICL implantation has better objective visual quality performance.

17.
International Eye Science ; (12): 466-470, 2023.
Artigo em Chinês | WPRIM | ID: wpr-964250

RESUMO

AIM: To determine the correlation among horizontal ciliary sulcus(HCS)diameter, vertical ciliary sulcus(VCS)diameter and corneal diameter in different anterior chamber depth(ACD)levels from patients with low to moderate myopia.METHODS: Retrospective study. A total of 78 patients(129 eyes)with low to moderate myopia who had preoperative examination of implantable contact lens(ICL)implantation in Shanghai Bright Eye Hospital from April 2021 to April 2022 were included. HCS, VCS and white to white(WTW)were measured and compared. Patients were divided into shallow ACD group(2.8 mm ≤ ACD ≤3.2 mm), medium ACD group(3.2 mm < ACD ≤3.4 mm)and deep ACD group(ACD > 3.4 mm)based on the ACD obtained by Pentacam. The HCS, VCS and WTW within and among groups were compared, and the correlation of WTW, HCS and VCS among each group was analyzed by Pearson and linear regression equation.RESULTS: There was no statistical difference in WTW and HCS overall and in groups with different ACD(P>0.05), while there was difference between VCS and both HCS and WTW(P<0.01). The WTW had a correlation with both HCS and VCS in each group, while correlation between WTW and VCS was weak in the deep ACD group(r=0.470, R2=0.221, P<0.01). Furthermore, the WTW, HCS and VCS in the shallow ACD group were statistically different from those in the medium and deep ACD groups(P<0.01).CONCLUSION: The WTW was suggested predicting HCS rather than perfectly replacing HCS before patients had the ICL operation among patients with low to moderate myopia. The predictability of VCS would decline as the ACD depth increasing, predicting VCS by WTW was not recommended.

18.
International Eye Science ; (12): 345-348, 2023.
Artigo em Chinês | WPRIM | ID: wpr-960964

RESUMO

AIM: To observe the efficacy of moderate and high myopia patients with vault greater than 1 000μm after implantation of phakic posterior chamber implantable contact lens(ICL).METHODS: A total of 42 patients(73 eyes)who received ICL implantation in the hospital and had postoperative vault greater than 1 000 μm between January 2014 and January 2017 were selected and retrospectively studied. Changes in visual acuity, intraocular pressure, corneal endothelial cell density, anterior chamber-related parameters(chamber angle, central anterior chamber depth, anterior chamber volume)and vault were compared among patients before surgery, at 1, 3, 6mo and 1a after surgery and at the last follow-up.RESULTS: The uncorrected visual acuity(UCVA)at 1, 3, 6mo and 1a after surgery and at the last follow-up was better than that before surgery(all P&#x0026;#x003C;0.05), and the chamber angle, central anterior chamber depth and anterior chamber volume were smaller or lower than those before surgery(all P&#x0026;#x003C;0.05), but there were no statistical differences in UCVA, chamber angle, central anterior chamber depth and anterior chamber volume at each time point after surgery(all P&#x0026;#x003E;0.05). The intraocular pressure at 1mo after surgery was lower than that before surgery(P&#x0026;#x003C;0.05), but the intraocular pressure at 3, 6mo and 1a after surgery and at the last follow-up was not statistically different from that before surgery(all P&#x0026;#x003E;0.05). There was no statistical significance in the corneal endothelial cell density at 1, 3, 6mo and 1a after surgery and at the last follow-up compared with that before surgery(all P&#x0026;#x003E;0.05). The vault at 1, 3, 6mo and 1a after surgery and at the last follow-up showed a decreasing trend, and the difference was statistically significant at each time point after surgery(all P&#x0026;#x003C;0.05).CONCLUSION: The short-term and long-term efficacy are better in moderate and high myopia patients with vault greater than 1 000 μm after ICL implantation, and there are no significant effects on the intraocular pressure and corneal endothelial cell. The postoperative anterior chamber structure is relatively stable and the vault tends to decrease over time. In most cases, close observation is sufficient and intraocular lens replacement is generally not required.

19.
International Eye Science ; (12): 228-231, 2023.
Artigo em Chinês | WPRIM | ID: wpr-960941

RESUMO

Implantable collamer lens(ICL)and toric ICL(TICL)are clinically common types of posterior chamber phakic intraocular lenses, they are mainly used to correct high myopia and low-to-moderate myopia of eyes whose corneal conditions are not suitable for corneal laser surgery. Accurate preoperative measurement, safe intraoperative implantation and appropriate postoperative location of lenses are critical to ensure the outcome of ICL implantable, and the appearance of V4c ICL with a central hole ensures the safety of this surgery to a greater extent. However, the intraocular position of both ICL and TICL is not invariable. Some studies have shown that the vault has a trend of decreasing year by year after ICL surgery, but its reason is unknown. And spontaneous rotation may occur after the TICL surgery, thereby causing visual loss, which is one of the main causes of TICL replacement. And postoperative changes in the position of the central hole also need attention. In addition, the visual quality of the operated eye will change after ICL/TICL implantation, but whether the change of intraocular positions of implanted lenses will affect the postoperative visual quality is also a problem that needs to be paid attention to and explored. Therefore, this paper reviewed the postoperative changes in vault, TICL axis, position of the central hole and their causes, as well as the effects of these changes on postoperative visual quality, offering valuable clinical guidance for accurate preoperative selection of ICL/TICL and surgical design, so as to improve the effectiveness and stability of ICL implantation in correction of myopic refractive error.

20.
International Eye Science ; (12): 222-227, 2023.
Artigo em Chinês | WPRIM | ID: wpr-960940

RESUMO

Corneal refractive surgery and intraocular collamer lens(ICL)implantation are the mainstream refractive surgery methods at present. Many studies have proved that ICL implantation can effectively improve the postoperative visual acuity of patients. ICL implantation has gained favor among refractive doctors and patients because of its multiple advantages. Excellent postoperative visual acuity and visual quality are the key factors to improve patients' satisfaction. In order to evaluate the subjective and objective visual quality of patients after operation and avoid complications, this article reviews the visual quality and postoperative complications after ICL implantation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA