Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 135-139, 2021.
Artigo em Chinês | WPRIM | ID: wpr-843024

RESUMO

@#Autologous fat transplantation in the treatment of velopharyngeal insufficiency has the advantages of good histocompatibility, small local trauma, few complications, reversible operation and simple postoperative nursing, which can effectively increase the velopharyngeal closure area. If the clinical effect is poor, other surgical methods can be used at any time for replacement. Although there are many advantages in the treatment of velopharyngeal insufficiency with autologous fat transplantation, there are still some problems in the selection of indication, donor site, injection dose, recipient site, follow-up evaluation, complications and prevention and treatment. Current research shows that autologous fat transplantation is mainly used in patients with mild or moderate velopharyngeal insufficiency, but with the improvement of fat acquisition and treatment techniques, the indications for autologous fat transplantation continue to expand, and autologous fat transplantation combined with palatoplasty or pharyngoplasty has been proposed for the treatment of severe velopharyngeal insufficiency. However, there are complications, such as fat absorption and obstructive sleep apnea syndrome. In addition, the application of autologous fat transplantation in severe VPI patients and how to improve the long-term stability of autologous fat transplantation need further study.

2.
Journal of Practical Radiology ; (12)2001.
Artigo em Chinês | WPRIM | ID: wpr-541899

RESUMO

Objective To investigate the suitable injection rate and dose in multi-slice CT perfusion imaging.Methods Randomized block design was adopted in this study.The treatment factor-contrast medium injection rate was classified into 3,4,5,6 and 8 ml/s;thesubjects were divided into 5 blocks grouped by contrast medium injection dose: 0.5,0.75,1,1.25 and 1.5 ml/kg.25 Beagles wererandomly enrolled to undergo cerebral CT perfusion imaging.After post processing,time to peak(TTP) and rise value(RV) were measured in superior sagital venous.Results Injection rate had a significant effect on TTP of superior sagital venous.There was no significant difference among group 5,6 and 8 ml/s.Compared with 8 ml/s,TTP of superior sagital venous was prolonged when injection rate 3,4 ml/swere adopted.Injection dose had a significant effect on RV of superior sagital venous.There was no significant difference among group 1,1.25 and 1.5 ml/kg.In comparison with 1 ml/kg,RV of superior sagital venous was prolonged when injection dose 0.5 and 0.75 ml/kg were adopted.Conclusion The quality of cerebral CT perfusion imaging is well enough even injection rate as low as 5 ml/s or injection dose as few as 1 ml/kg.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA