Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Adicionar filtros








Intervalo de ano
1.
Artigo em Chinês | WPRIM | ID: wpr-886498

RESUMO

@#Objective     To explore the evolving strategies and compare perioperative and long-term outcomes of tricuspid valve replacement (TVR) in recent 20 years in our hospital. Methods    Between 1998 and 2018, the clinical data of 608 patients who underwent TVR at the Department of Cardiac Surgery, Guangdong Provincial People’s Hospital were retrospectively analyzed. There were 201 males and 407 females, with a median age of 47.0 (36.0, 57.0) years. Patients were divided into a biological tricuspid valve (BTV, n=427) group and a mechanical tricuspid valve (MTV, n=181) group. Propensity score matching was used to balance the baseline difference. Surgical strategy evolving, postoperative and long-term outcomes were analyzed between the two groups. Results    Since 2008, the usage ratio of biological valves was significantly higher than that of mechanical valves. Seventy-nine (13.0%) patients died in hospital after TVR. Before propensity score matching, the postoperative mortality of the BTV group was higher than that of the MTV group (15.2% vs. 7.7%, P=0.012), and there was no statistical difference between the two groups after matching (10.4% vs. 7.2%, P=0.372). The duration of postoperative ventilator support in the BTV group was longer than that in the MTV group [22.0 (15.0, 37.0) h vs. 19.0 (11.0, 27.0) h, P=0.003], and the incidence of postoperative dialysis and re-thoracotomy exploring for bleeding was higher in the BTV group (8.9 % vs. 2.8%, 9.4% vs. 6.6%, respectively). However, there was no statistical difference in mortality after matching. The median follow-up time of discharged patients was 101.0 (65.0, 147.0) months, ranged from 1 to 265 months, and the follow-up rate was 82.2%. During the follow-up period, there were 101 deaths (19.1%) of whom 68 were from the BTV group and 33 from the MTV group. The survival rates at 1 year, 5 years, 10 years, 15 years and 20 years of all patients were 85.0% (95%CI 82.2-87.9), 78.9% (95%CI 75.7-82.4), 71.1% (95%CI 67.3-75.3), 59.7% (95%CI 54.2-65.6) and 51.7% (95%CI 43.3-60.7), and there was no statistical difference between the two groups after matching (P=0.46). The median time of tricuspid valve failure was 84.0 (54.0-111.0) months. Conclusion    TVR is associated with high perioperative risks. There is no statistical difference in early mortality and long-term survival between biological and mechanical valve, while patients with mechanical valve has higher risk of re-operation for valve failure. Therefore, the type of prosthetic valve can be selected according to the patients' age, physical condition and the doctors’ experience.

2.
Artigo em Chinês | WPRIM | ID: wpr-711784

RESUMO

Objective To explore some reasonable ways of anticoagulation for pregnant women with mechanical prosthetic valves.Methods Retrospective analysis was conducted for 27 women with mechanical prosthetic valves who have born children after their cardiac surgeries.Numbers of pregnancies,ages,ways of anticoagulation during pregnancy,ways of anticoagulation before pregnancy,valve thrombosis events,thromboembolism events,bleeding events,outcomes of pregnancy and ways of delivery were collected and studied.Comparing adverse events and outcomes of different ways of anticoagulation which those women used during their pregnancies.Results 27 women with mechanical prosthetic valves experienced 41 pregnancies,and bore 28 children.24 pregnancies used oral low does warfarin(< 5 mg/day) to anticoagulate,2 minor bleeding events and 10 early abortion occurred,no abnormal neonates were found,14 healthy neonates were born.6 pregnancies used low-molecularweight heparin to anticoagnlate from 6th week to 12th week,they used oral warfarin to anticoagulate in rest weeks of pregnancy.1 late abortion occurred,1 fetus with hydrocephalus was found at 20th week,then induced labour was conducted.4 healthy neonates were born.11 pregnancies used low-molecular-weight heparin to anticoagulate until delivery,1 early abortion,2 minor bleeding events and 1 valve thrombosis occurred.10 neonates were born,and 1 of them has hypoxic-ischemic encephalopathy,the other 9 neonates were healthy.Conclusion For pregnant women with mechanical prosthetic valves,using oral low does warfarin throughout pregnancy is a reasonable way of anicoagnlation with low risk of maternal and fetal adverse events except high risk of abortion.Low-molecular-weight heparin is hopeful anticoagulant agent for pregnant women with mechanical prosthetic valves,but more studies about its safety and effectiveness should be conducted.

3.
Artigo em Japonês | WPRIM | ID: wpr-378392

RESUMO

<p>A 41-year-old man had undergone mitral valve replacement (On-X 27/29 mm) and tricuspid valve replacement (TVR) (On-X 31/33 mm) for infectious endocarditis of the mitral valve and severe tricuspid regurgitation 6 years ago. Postoperative echocardiography showed aortic regurgitation and perivalvular leakage of the prosthetic mitral valve and left ventricular (LV) septal perforation. He therefore underwent aortic valve replacement (On-X 25 mm), patch closure of a leak around the prosthetic mitral valve, direct closure of the LV septal perforation, and re-TVR (On-X 31/33 mm). After discharge, he was placed on anticoagulant therapy with warfarin (international normalized ratio of prothrombin time target : 2.0-2.5). Transthoracic echocardiography three and -a half years after the operation revealed an increased mean tricuspid valvular pressure gradient (14 mmHg) compared with that seen on an echocardiograph of previous year. Cine-fluoroscopy showed almost no movement of the leaflets of the mechanical tricuspid valve. Tricuspid valve thrombosis or pannus formation was suspected. He was placed on thrombolytic therapy using tissue plasminogen activator (monteplase 1.6 million units). Five days later, cine-fluoroscopy showed movement of the mechanical tricuspid valve leaflets, and echocardiography revealed recovery of the mean tricuspid valve pressure gradient (4 mmHg). Valvular thrombosis was diagnosed as the cause of the non-moving valve. Hemorrhagic and embolic complications were not observed. Thrombolytic therapy was extremely useful.</p>

4.
Artigo em Chinês | WPRIM | ID: wpr-840381

RESUMO

Objective: To investigate the surgical diagnosis and treatment of chronic stenosis of mechanical prosthetic valve complicated with acute dysfunction, so as to deepen our knowledge on chronic stenosis of mechanical prosthetic valve. Methods: The clinical data of 5 patients with chronic stenosis of mechanical prosthetic valve complicated with acute dysfunction were retrospectively analyzed, and the relevant literatures were reviewed. Results: Re-operation (mechanical prosthetic valve replacement) was performed once the diagnoses were confirmed. The patients recovered well; the cardiac function was obviously improved; and there were no early complications. Conclusion: Chronic stenosis of mechanical prosthetic valve should be strongly suspected when they have symptoms indicating valvular stenosis. Complication of acute mechanical prosthetic valve dysfunction is not difficult to diagnose, and prompt operation is important to save the life of patients.

5.
Artigo em Chinês | WPRIM | ID: wpr-567103

RESUMO

Objective To investigate the surgical diagnosis and treatment of chronic stenosis of mechanical prosthetic valve complicated with acute dysfunction,so as to deepen our knowledge on chronic stenosis of mechanical prosthetic valve.Methods The clinical data of 5 patients with chronic stenosis of mechanical prosthetic valve complicated with acute dysfunction were retrospectively analyzed,and the relevant literatures were reviewed.Results Re-operation(mechanical prosthetic valve replacement) was performed once the diagnoses were confirmed.The patients recovered well;the cardiac function was obviously improved;and there were no early complications.Conclusion Chronic stenosis of mechanical prosthetic valve should be strongly suspected when they have symptoms indicating valvular stenosis.Complication of acute mechanical prosthetic valve dysfunction is not difficult to diagnose,and prompt operation is important to save the life of patients.

SELEÇÃO DE REFERÊNCIAS