Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Acta Pharmaceutica Sinica ; (12): 1293-1300, 2023.
Artigo em Chinês | WPRIM | ID: wpr-978681

RESUMO

A hydrophilic interaction chromatography tandem mass spectrometry method was developed for simultaneous quantification of 35 components in gualoupi injection. The analytes were separated with an ACQUITY XBridge Amide column using 20 mmol·L-1 ammonium formate aqueous solution (pH 3.0) as mobile phase A and 20 mmol·L-1 ammonium formate (pH 3.0)∶acetonitrile (1∶9) as mobile phase B for gradient elution. Mass spectrometry with dynamic multiple reaction monitoring and external standard method were used for quantitative analysis. A total of 35 components were determined in 10 batches of gualoupi injection. The results showed that the 35 compounds had a good linear relationship within their respective concentration ranges with the correlation coefficients (R2 > 0.998 0), the recoveries ranged from 76.6% to 118.5%. The results showed that γ-aminobutyric acid, trigonelline, alanine, threonine, homoserine, citrulline, and leucine were abundant in gualoupi injection, while nicotinamide, methylsuccinic acid, cytosine and choline account for a low percentege. The present study provides an important reference for elucidation of the effective material basis and the improvement of quality standard of gualoupi injection.

2.
China Journal of Chinese Materia Medica ; (24): 3982-3987, 2016.
Artigo em Chinês | WPRIM | ID: wpr-272743

RESUMO

To establish an UPLC method for the simultaneous determination of 8 compounds in Eclipta Herba, such as isoquercitrin, luteoloside, demethylwedelolactone, isochlorogenic acid A, isochlorogenic acid C, luteolin, wedelolactone and apigenin. The experiment was performed with a Waters Acquity UPLC BEH C₁₈ (2.1 mm×100 mm, 1.7 μm) column by gradient elution of 0.1% formic acid in water and acetonitrile: 0-4 min,10%-13% A; 4-10 min, 13%-16% A; 10-13 min, 16%-25% A; 13-17 min, 25%-28% A; 17-20 min,28%-40% A;20-25 min,40%-95% A. The flow rate was 0.3 mL•min⁻¹.. The condition of was the colum temperature was maintained at 35 ℃ and the detected wavelength was set at 350 mm. 8 components were separated clearly by this method. Also a good linearity was obtained between the chosen concentration(r≥0.999 0). The measured data showed that the recovery rate range from 96.60%-103.4% (n=6) and their RSD values were 0.86%-2.4%. The method has high recovery rate, good reproducibility and stability. It provides a scientific basis for the identification and quality evaluation of Eclipta Herba.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA