China Pharmacy ; (12)1991.
Artigo em Chinês | WPRIM | ID: wpr-516094

RESUMO

A rapid and simple HPLC method for determination of propafenone concentration in human plasma is described. Dyclonine hydrochloride was used as an internal standard. YWG-C_(18) column(10?m)was used with a mobile phase of methanol-acetonitrile-0.05mol/L acetate buffer(pH 4.02)-diethylamine(45.5:19.5:35). Detection was performed by ultraviolet absorption at 254nm. The detection limit of propafenone waw 5ng (S/W=3)or 25ng/ml in plasma. Assay linearity was shown in a range of 50~500ng/ml with a regression coefficient of 0.9993. The recovery(n=4)was 100.5%,the CV of within-day and day-to-day being less than 3%. No interference was found from endogenous compounds or commonly used drugs. So it can be applied to pharmacokinetic studies and therapeutic monitoring.