Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
Philippine Journal of Allied Health Sciences ; (2): 51-57, 2024.
Artigo em Inglês | WPRIM | ID: wpr-1006830

RESUMO

Background@#The COVID-19 pandemic has greatly affected the sports industry, postponing events worldwide. To adapt to the situation, athletes have been forced to train at home. Bubble training was introduced to provide a safe and conducive training environment while adhering to government health protocols. However, concerns have emerged regarding the set-up’s implementation.@*Objective@#The study aims to explore the lived experiences of UAAP Season 84 and NCAA Season 97 student-athletes who underwent bubble training.@*Methods@#The study will employ a qualitative phenomenological approach based on Seligman's Well-Being Theory. A purposive sampling technique will be used to recruit at least seven eligible student-athletes. Data will be collected through on-site or online interviews using a semi-structured interview guide to reveal a narrative of the student-athletes' bubble training experiences, common themes, and patterns. Deductive thematic analysis approach will be used with the help of the NVivo software program.@*Expected Results@#This study is expected to develop themes from the daily bubble training routines, habits, coping strategies, and perceived thoughts and feelings of Filipino collegiate student-athletes, regarding their emotions, engagement, relationships, meaning, and achievement in bubble training. This may provide insights to the government, educational institutions, and athletic associations on possible comprehensive guidelines if they plan to implement bubble training when the need arises.


Assuntos
Atletas , Estudantes
2.
Cancer Research on Prevention and Treatment ; (12): 1097-1102, 2023.
Artigo em Chinês | WPRIM | ID: wpr-998957

RESUMO

Objective To quantify the setup errors for the different anatomical sites of patients who received intensity-modulated radiotherapy (IMRT) with linear accelerator on-board kilovolt fan beam CT(kV-FBCT) as non-isocenter IGRT and megavolt cone beam CT (MV-CBCT) as isocenter IGRT. Methods A retrospective analysis was performedon 70 patients who underwent radiotherapy, kV-FBCT, and/or MV-CBCT scans after each routine setup prior to IMRT. The average displacement (M), systematic error (Σ), and random error (б) at different treatment sites in the left-right, anterior-posterior, and cranial-caudal directions were calculated according to the individual displacements. The formula 2.5Σ+0.7б was used to estimate the PTV margin in respective direction. For each single patient, the root mean square in three directions was used as 3D displacement. Results A total of 1130 displacements were recorded in the 70 patients. The PTV margin was estimated to be 1.9-3.1 mm in head and neck cancer, 2.8-5.1 mm in thoracic cancer, 4.6-5.1 mm in breast cancer, 3.0-5.5 mm in upper abdominal cancer, and 3.5-6.8 mm in pelvic tumor. For the 3D mean displacements, the head and neck, thoracic, breast, upper abdominal, and pelvic cancer were 2.4±1.0, 4.0±1.6, 4.1±2.0, 4.6±2.1, and 4.6±2.1 mm, respectively. The average 3D displacement obtained by kV-FBCT and MV-CBCT were 4.1 and 3.4 mm, respectively (P=0.212). Conclusion The quantitative setup-error data can be obtained using linear accelerator on-board FBCT, and the non-isocenter IGRT induced set-up error cannot be negligible.

3.
Indian J Ophthalmol ; 2022 Dec; 70(12): 4174-4179
Artigo | IMSEAR | ID: sea-224754

RESUMO

Purpose: Indication of laser peripheral iridotomy (LPI) is often conjectural due to dependency on gonioscopy and strict dichotomous classification of occludability. Indentation gonioscopy is the gold standard but is under?utilized for various reasons. The prevalence of primary angle closure disease (PACD) in eastern India is 1.5–1.9%, with a 22% five?year progression rate. Many angle closure patients may go blind without timely diagnosis and iridotomy. General ophthalmologists need alternate, validated methods for diagnoses. Pilocarpine eye drop causes miosis, and flattens the iris, producing angle changes detectable by spectral domain optical coherence tomography (SD?OCT). We hypothesized that the amount of angle change may be a suitable indicator for iridotomy. Methods: Our prospective cross?sectional single?masked observational study evaluated pilocarpine?induced changes in angle parameters detected by SD?OCT. Out of 372 patients enrolled, 273 patients (539 eyes) remained, with a mean age of 48.6 years (SD = 10.36). All eyes were graded by the Van Herick (VH) method, gonioscopy, and anterior segment (AS) SD?OCT and reassessed after pilocarpine drops. Results: The sensitivity and specificity of tomography measurements against gonioscopy grades were 61% and 85%, respectively. The receiver operating characteristic (ROC) curve was 0.85. Pilocarpine?induced angle widening was significant in gonioscopically narrower angles. Low Van Herick grades (217 eyes), narrow gonioscopy grades (238 eyes), and a narrow OCT angle value (165 eyes) were candidates for iridotomy. Conclusion: Our study results showed that pilocarpine?induced angle widening detected by SD?OCT could be a strong objective indicator for LPI

4.
Indian J Cancer ; 2022 Dec; 59(4): 515-520
Artigo | IMSEAR | ID: sea-221726

RESUMO

Background: Medulloblastoma is the commonest embryonal brain tumor in children. It has shown improved outcomes with combined modality treatment. We aimed to study patient characteristics and survival outcomes of patients with this disease across two tertiary care centers in India. Methods: We analyzed data of patients with histological diagnosis of medulloblastoma treated from January 2010 to January 2016. Patient characteristics and follow-up data were retrieved from hospital records. Descriptive statistics were used to describe clinical and pathological characteristics. Overall survival (OS) was calculated from date of diagnosis to death due to any cause. Relapse-free survival (RFS) was calculated from date of diagnosis to occurrence of relapse or death. Result: Out of 26 patients treated, 24 were children and 2 were adults. Median age was 10 years (range = 0.8–22 years). Twenty (76.9%) patients were male. Fifteen (57.7%) patients were stratified as high-risk (HR), rest 11 (42.3%) were categorized as average risk (AR). Histopathology showed classical variety in majority of patients except for 4 (15%) cases, 3 with desmoplastic and 1 with anaplastic subtype. Median follow-up was 49.7 months (range= 4.2–102.5 months). Overall, eight (30.8%) patients relapsed and six (23%) deaths occurred. Five (33.3%) patients in HR category and 3 (27.3%) patients in AR group showed relapse. Median RFS and OS were not yet reached. Five-year RFS was 69.2% whereas five-year OS was 76.9%. Conclusion: This study highlighted patient characteristics and treatment outcomes in Indian patients. With adherence to standard treatment, high remission rates and improvement in mortality rates were achieved.

5.
Chinese Journal of Radiation Oncology ; (6): 365-369, 2022.
Artigo em Chinês | WPRIM | ID: wpr-932677

RESUMO

Objective:To compare the comprehensive performance of three Varian on-board image (OBI) image systems (KV-CBCT, KV-planar and MV-EPID) and to explore the value of the combined application of these three systems in daily image-guided radiotherapy for nasopharyngeal cancer.Methods:KV-CBCT, KV-planar and MV-EPID scanning and registration were carried out in the left and right/abdominal and back/head and foot direction on human head and neck phantom. The set-up error, registration time, additional radiation dose and image quality of the three systems were compared by F-test.Results:KV-CBCT, kV-planar and MV-EPID were scanned for 55 times, respectively, and the set-up errors in the left and right/abdominal and back/head and foot direction of the three image-guided systems were (0.00±5.43)/(-0.02±5.49)/(0.02±5.58) mm, (0.04±5.49)/(0.02±5.56)/(0.02±5.54) mm, (0.02±5.22)/(0.11±5.34)/(-0.04±5.33) mm, respectively ( P=0.999, 1.000, 0.989). The average time consuming was (200±45) s, (120±36) s and (115±42) s; the additional radiation dose from low to high was kV-planar, KV-CBCT and MV-EPID; the image quality from low to high was MV-EPID, kV-planar and KV-CBCT. Conclusions:Three image-guided systems can meet the requirements of image-guided radiotherapy for nasopharyngeal cancer. Based on the overall performance of the three systems, 1 CBCT+ 4 kV planar per week is recommended and EPID should be used as a backup system in daily image-guided radiotherapy for nasopharyngeal cancer. This scheme makes full use of the high image quality of CBCT and the low radiation of kV planar to realize the regular detection of nasopharyngeal cancer volume change and the implementation of high-precision radiotherapy.

6.
Chinese Journal of Radiation Oncology ; (6): 916-921, 2022.
Artigo em Chinês | WPRIM | ID: wpr-956932

RESUMO

Objective:To compare the difference between breast bracket combined with polyurethane foam and single polyurethane foam in the accuracy of immobilization, providing a better immobilization for breast cancer radiotherapy.Methods:Fifty breast cancer patients who received radiotherapy in Sun Yat-sen University Cancer Center from March 2021 to July 2021 were selected. Among them, 25 patients were immobilized with polyurethane foam (foam group), and the other 25 patients were immobilized with polyurethane foam combined with breast bracket (combination group). All patients were scanned by CBCT once a week to obtain setup errors in the SI, LR and AP directions for t-test. The formula M PTV=2.5 Σ+0.7 σ was used to calculate the margin of the planning target volume(M PTV). Results:The setup errors in the foam group were SI (2.0±3.26) mm, LR (0.88±2.76) mm, AP (1.22±3.55) mm, Rtn -0.24°±0.85°, Pitch 0.16°±1.11°, Roll -0.32°±1.05°, and the M PTV were 6.75 mm, 8.46 mm and 8.73 mm, respectively. The setup errors in the combination group were SI (1.0±3.01) mm, LR (0.62±2.74) mm, AP (1.82±3.21) mm, Rtn 0.64°±0.59°, Pitch 0.71°±1.22°, Roll 0.29°±0.73°, and the M PTV were 6.35 mm, 7.47 mm, and 7.61 mm, respectively. After comparing the setup errors in the three-dimensional directions between two groups, the t value of LR, SI, AP and Rtn, Pitch, Roll was -4.304, -2.681, 1.384, and -9.457, -3.683, -5.323, respectively. And the differences in the LR, SI, Rtn, Pitch and Roll directions were statistically significant (all P<0.05). Conclusions:The immobilization effect of polyurethane foam combined with breast bracket is better and the M PTV is also smaller than those of polyurethane foam alone. Therefore, it is recommended to use polyurethane foam combined with breast bracket for immobilization in breast cancer radiotherapy.

7.
Chinese Journal of Radiological Medicine and Protection ; (12): 871-876, 2022.
Artigo em Chinês | WPRIM | ID: wpr-956874

RESUMO

Objective:To investigate the performance of optical surface imaging (OSI) in the postmastectomy radiotherapy setup and to assess the effects of 3D printed silicone bolus on OSI detection precision.Methods:A retrospective analysis was conducted for 16 patients treated with left-sided postmastectomy radiotherapy (PMRT) in West China Hopital, Sichuan University from January to April, 2021. The setup errors of 16 patients without bolus detected using OSI (OSI no-bolus, OSI n) were obtained before error correction was conducted using cone-beam CT (CBCT). The correlation between OSI n and CBCT was analyzed, and then the diagnostic efficacy of OSI was assessed using the receiver operating characteristic (ROC) curves. The setup errors of six patients with 3D printed silicone bolus detected using OSI (OSI bolus, OSI b) were obtained through off-line image registration, and then the detection precision of OSI n and OSI b in the translational directions was compared. Results:The setup errors in the case of OSI n were highly correlated with CBCT in the translational direction ( r ≥ 0.80), but were weakly correlated in the rotation direction ( r < 0.40). In the ROC analysis, the area under the curve (AUC) in the y direction was the lowest and was in the order of AUC 5 mm ≥AUC 3 mm > 0.75 for any translational direction. The difference in the detection precision between OSI n and OSI b was not statistically significant in the x and z directions ( P > 0.05), but was statistically significant in the y direction ( Z = -2.56, P = 0.01). In the y direction, the systematic error of detection precision in the case of OSI b was 3.11 mm higher than that in the case of OSI n, and the random error of detection precision in the case of OSI b was 1.9 mm higher than that in the case of OSI n. Conclusions:OSI cannot yet substitute CBCT in the postmastectomy radiotherapy setup, but its detection error is still within the clinically acceptable range. The performance of OSI-assisted setup is expected to be further improved by mitigating the interference of factors such as bolus in the imaging path through operational training.

8.
Chinese Journal of Radiological Health ; (6): 517-523, 2021.
Artigo em Chinês | WPRIM | ID: wpr-974589

RESUMO

Objective To measure set-up errors in intensity modulated radiotherapy of postoperative rectal cancer (IMRTPRC), and analyze the effects of target volumes and normal tissues by set-up errors in IMRTPRC. Methods electrical field device was used to measure the set-up errors of 30 patients in IMRTPRC; we randomly selected 6 patients, and simulated their radiotherapy set-up errors in TPS. Then were counted the dose distribution and analyze relative dosimetrical parameters of target volumes, normal tissues and got the set-up errors effecting on dosimetry. Statistical analysis was performed using an SPSS statistical package(Version 19.0). Results The set-up errors on X, Y and Z direction are (−0.82 ± 2.67) mm, (0.42 ± 2.91) mm and (0.47 ± 1.64) mm respectively. In regard to set-up errors of L5, R7, G8, T5, B6 and A4, most of statistical properties of PTV’s D98%, D95%, D50%, D2%, Hi and Ci are smaller than 0.05, so the differences have statistical values; In L5-Hi, G8-D2%, T5-D50% and B6-D2%, so these differences have not statistical value (P>0.05). In L5, R7, G8, T5, B6 and A4, about half of the statistical properties of normal tissue like bowl, bladder and femur heads, are smaller than 0.05 and have statistical value, and the rest of them are negative. Conclusion The dose of PTV is decreased due toset-up error. Uniformity and conformity is also gone bad. So the dosimetry quantity of PTV can not get reach to the initial design level. However, the dose of normal tissues like bowl, bladder and femur heads, are increased unexpectedly.

9.
ASEAN Journal of Psychiatry ; : 1-8, 2021.
Artigo em Inglês | WPRIM | ID: wpr-922829

RESUMO

@#Psychosis can be defined as a mental disorder in which a person’s thoughts, affective response, ability to recognize reality, and ability to communicate and relate to others are sufficiently impaired to grossly interfere with his or her capacity to deal with reality. The classical characteristics of psychosis are impaired reality testing, hallucinations, delusions, and illusions. While factitious disorder and malingering are usually acknowledged as contrived psychiatric conditions for acquisition of interior or exterior profits, respectively, another alternative, also, exists that though is not manufactured individually, is enforced peripherally. Such cases, which are usually referred by the judge’s ruling, for evaluation and treatment, are more important than comparable simulated or genuine mental conditions, because incorrect diagnosis, or careless, cagily, and guarded validation of preliminary diagnosis that has been issued in the authorized or emergency department, can seriously endanger the individual’s civil rights, while it should not be overlooked that incorrect diagnosis is a kind of malpractice that may harm an individual awfully. In the present article the clinical picture of the said situation, in addition to some case histories, and recommendable hints for differential diagnosis between different types of psychoses, has been discussed.

10.
Chinese Journal of Radiation Oncology ; (6): 822-827, 2021.
Artigo em Chinês | WPRIM | ID: wpr-910475

RESUMO

Objective:To obtain the inter-fractional set-up errors of intensity-modulated radiotherapy (IMRT) of cervical cancer by cone-beam CT (CBCT), and to analyze the variations of the set-up errors on the cumulative dose deviation of the target volume.Methods:A total of 48 patients with cervical cancer who underwent IMRT were enrolled in this study, and the set-up errors of 696 CBCTs were obtained. The set-up errors were input into the treatment planning system, and the cumulative set-up error dose was obtained by superposing the set-up errors dose. The deviation percentage was calculated by the deviation formula and the standard planning dose.Results:The set-up errors caused the offset of isocenter distance by 0.58(0.36, 0.80) cm. Different statistical differences were noted between the cumulative set-up error dose and the standard planning dose by WilCoxon test. All the dose deviations in the target volume were reduced, and the differential dose volume histogram (DVH) appeared negatively skewed, and the peak value was declined. The DVH diagram shifted to the left with an inverse S-curve and the slope was increased. The HI deviation of the target volume from small to large were: CTV 1, CTV 2, GTV/CTV, CTV 3, CTV n, CTV all, and GTV nd; The HI deviation of the target volume were increased. Conclusions:The effect of set-up errors in IMRT of cervical cancer upon the cumulative doses of the target volume significantly differs. The cumulative dose of the target volume is reduced, and the uniformity of the target volume dose becomes worse. The uncertainty of the inter-fractional position leads to an increase or decrease in the the fractional doses of the target volume. The biological effect on tumor cells and the tumor recurrence remains to be investigated. In IMRT of cervical cancer, the CBCT position calibration is required before each treatment to ensure the dose accuracy of each structure in the target volume.

11.
Artigo | IMSEAR | ID: sea-202019

RESUMO

Background: Quality of life in elderly is more relevant towards an ageing society. In India, the awareness is very little about the special needs of the elderly and their care takers (physical and mental health, psychological and social support). Furthermore, among elderly there is a variation between those living in old age homes (OAHs) and those living in general population. Hence the present study was undertaken to assess and compare the quality of life of elderly living in OAHs and community.Methods: A cross-sectional descriptive study was conducted among elderly in old age homes and family set up of Kanchipuram district, Tamil Nadu. QOL of elderly was assessed using WHO QOL - brief questionnaire after taking informed consent from the participants. Data was analyzed using SPSS 23.Results: A total of 106 elders from each group old age home and family setup were the study participants. Quality of life was good 72.5% in family and in OAHs it was only 56.2%. The main reason for residing in OAHs was no family, lack of care takers. All the four domains were found to be highly statistically significant.Conclusions: From this study we are able to find out that quality of life in family setup is better than OAHs, psychologically many people were depressed as they live separately from their family and relatives, friends and the community they lived.

12.
Chinese Journal of Radiation Oncology ; (6): 47-51, 2020.
Artigo em Chinês | WPRIM | ID: wpr-868547

RESUMO

Objective To investigate the correlation between skin elasticity and setup error in optical surface image-guided radiotherapy.Methods The skin elasticity (R7) data of the head,chest and abdomen were extracted and analyzed its correlation with age by systematic literature review.Fifty-four patients diagnosed with nasopharyngeal carcinoma,breast cancer and cervical cancer were recruited in this study.Firstly,the patients were positioned based on the room laser and markers.Subsequently,the patient position was verified by the Varian On-Board Imager,and then C-Rad Catalyst was adopted to obtain surface images in two states (mask or non-mask) as reference images.In the subsequent fraction treatment,after initial positioning,the local calibration was performed by Catalyst,and setup errors in three directions were recorded.Meanwhile,the patient setup was verified by CBCT twice a week.The Pearson correlation analysis was performed to analyze the correlation between setup error and age.Results The skin elasticity was negatively correlated with aging (P<0.01).The correlation coefficient between random error and age in headand-neck cancer were 0.645,0.624 and 0.866 in the AP,SI and LR directions (all P<0.05) for male patients without mask,respectively.The system error was significantly correlated with age in the LR direction (P<0.05) for male patients,and in the AP direction (P< 0.05) for female patients with head-and-neck cancer without mask.The setup error had a significant correlation with skin elasticity in male patients with head-and-neck cancer,and the sequence of absolute value of correlation coefficient was LR > SI > AP.Conclusion In optical surface-guided radiotherapy of head and neck cancer,skin elasticity may be a significant index for assessing the setup errors in male patients.

13.
Chinese Journal of Radiation Oncology ; (6): 47-51, 2020.
Artigo em Chinês | WPRIM | ID: wpr-798806

RESUMO

Objective@#To investigate the correlation between skin elasticity and setup error in optical surface image-guided radiotherapy.@*Methods@#The skin elasticity (R7) data of the head, chest and abdomen were extracted and analyzed its correlation with age by systematic literature review. Fifty-four patients diagnosed with nasopharyngeal carcinoma, breast cancer and cervical cancer were recruited in this study. Firstly, the patients were positioned based on the room laser and markers. Subsequently, the patient position was verified by the Varian On-Board Imager, and then C-Rad Catalyst was adopted to obtain surface images in two states (mask or non-mask) as reference images. In the subsequent fraction treatment, after initial positioning, the local calibration was performed by Catalyst, and setup errors in three directions were recorded. Meanwhile, the patient setup was verified by CBCT twice a week. The Pearson correlation analysis was performed to analyze the correlation between setup error and age.@*Results@#The skin elasticity was negatively correlated with aging (P<0.01). The correlation coefficient between random error and age in head-and-neck cancer were 0.645, 0.624 and 0.866 in the AP, SI and LR directions (all P<0.05) for male patients without mask, respectively. The system error was significantly correlated with age in the LR direction (P<0.05) for male patients, and in the AP direction (P<0.05) for female patients with head-and-neck cancer without mask. The setup error had a significant correlation with skin elasticity in male patients with head-and-neck cancer, and the sequence of absolute value of correlation coefficient was LR>SI>AP.@*Conclusion@#In optical surface-guided radiotherapy of head and neck cancer, skin elasticity may be a significant index for assessing the setup errors in male patients.

14.
Chinese Journal of Radiation Oncology ; (6): 849-853, 2019.
Artigo em Chinês | WPRIM | ID: wpr-801067

RESUMO

Objective@#To evaluate the dosimetric effects of set-up errors on nasal NK/T cell lymphoma by introducing set-up errors into the radiotherapy planning system for dose reconstruction.@*Methods@#Ten patients with nasal NK/T cell lymphoma were recruited. A non-coplanar volumetric modulated arc therapy plan was designed for CT image and clinical target area of each patient. After the completion of the plan, the set-up errors were introduced into the radiotherapy plan by changing the ISO of the treatment, and dose calculation was performed to reconstruct the dose distribution.@*Results@#With the increase of system set-up errors, the dose of target was decreased and the order affected by set-up errors in different directions was: left-right direction> head-foot direction> front-rear direction. When the translational set-up errors in each direction were -3 mm to 3 mm and the rotating set-up errors were -3° to 3°, the range of dose change in all targets was less than ±3%. When the set-up errors in all directions were ≤ 3 mm, the dose of organ at risk was less than or similar to the prescribed dose. When the set-up errors were> 3 mm, the doses of lens, spinal cord, parotid gland and optic nerve gradually exceeded the prescribed dose. Only when the rotating set-up errors were ≥ 3°, the dose of lens exceeded the prescribed dose. Special attention should be paid to the influence of the greater set-up errors in the left and right direction on lens, spinal cord and parotid gland, as well as on the spinal cord due to the larger set-up errors in the front and rear direction. After the actual set-up errors were introduced from our department, it exerted slight effect on the irradiation dose of GTV and CTV, which was less than ±2%. In a few cases, the dose of organ at risk potentially exceeded the prescribed dose limit, and special attention should be diverted to overdose of the lens and optic nerve.@*Conclusions@#The set-up errors will result in target dose deficiency and overdose of organ at risk in nasal NK/T cell lymphoma, especially upon the set-up errors in the left and right direction. The effect of 3 mm and 3° set-up errors on target and organ at risk is limited. Therefore, it is recommended to maintain the single direction set-up errors within 3 mm and 3°. The actual set-up errors introduced from our department exert little effect on the target dose, but a small number of organs are at risk of exceeding the prescribed dose limit. It is necessary to increase the evaluation of the extension region of organ at risk.

15.
Chinese Journal of Radiological Medicine and Protection ; (12): 434-438, 2019.
Artigo em Chinês | WPRIM | ID: wpr-754986

RESUMO

Objective To evaluate the difference of set-up errors between thermoplastic mask and breast bracket in patients receiving intensity-modulated radiotherapy after breast conserving surgery,and the impact of clinical factors associated with set-up errors.Methods A total of 34 patients treated with intensity-modulated radiotherapy after breast conserving surgery from January 2016 to June 2018 were reviewed.Eighteen patients were fixed with thermoplastic mask,and sixteen were with breast bracket.Weekly CBCT scan records were used to analyze set-up errors,and group systematic and random errors were computed.The influence of clinical factors on set-up errors was also analyzed.Results The immobilization technique with thermoplastic mask showed great superior in comparison with breast bracket;however,only in the Ty(translation) and Ry(rotation),the differences had significance.Based on group systematic and random errors,PTV margins in Tx,Ty and Tzwere 2.65,4.36 and 2.87 mm in thermoplastic mask group,as well as 5.71,6.07 and 4.20 mm in breast bracket group,respectively.Multi-factor regression analysis showed that BMI was independent factors affecting set-up errors.Conclusions Compared with breast bracket,the immobilization technique with thermoplastic mask has the potential of reducing set-up errors and PTV margins in patients receiving intensity-modulated radiotherapy after breast conserving surgery,especially in patients with high BMI.

16.
Chinese Journal of Radiation Oncology ; (6): 369-372, 2019.
Artigo em Chinês | WPRIM | ID: wpr-745313

RESUMO

Objective To investigate the difference of styrofoam and breast carrier in postposition fixation of intensity-modulated radiotherapy after breast conservative surgery for breast cancer patients.Methods From February 2018 to August 2018,tweenty-four patients with breast cancer in Sun Yet-Sen Memorial Hospital of Sun Yet-sen University were selected for this study,who underwent hypofactionationed radiotherapy after breast conservative surgery with total dose 42.56 Gy/16Fractions.They were randomized into styrofoam test group and breastcarrier control group.Cone beam CT as used to record the positioning error under the directions of left and right (x),head and foot (y),abdomen and back (y) within two groups at the first,third,fifth,seventh,eleventh time before irradiation.Furthermore,the PTV extension margin was calculated and the positioning time of two groups was recorded.Two sets of pendulum errors were analyzed by independent sample T-test,and the outspread value of inter-fractional set up error of the PTV was calculated.Results The errors of the test group and the control group in the direction of x,y,z were as follows:(2.36±1.89) and (2.56±2.05) mm (P=0.49),(1.76± 1.78) and (3.28±2.79) mm (P<0.05),(1.47± 1.49) and (1.73± 1.81) mm (P=0.28).The extension values of inter-fractional set up error of CTV to PTV were 2.97,2.92,2.21 mm and 3.41,4.09,2.59 mm respectively.The time of single positioning was (3.4± 1.1) and (5.5 ± 3.1) min respectively (P=0.01).Conclusion Styrofoam has better positioning accuracy and efficiency compared with breast carrier.

17.
Cancer Research and Clinic ; (6): 180-183,189, 2018.
Artigo em Chinês | WPRIM | ID: wpr-712791

RESUMO

Objective To analyze set-up errors for irradiation of nasopharyngeal carcinoma by using kilo-voltage cone beam computed tomography (kV-KBCT) scanning, and to calculate the external margin from planning target volume (PTV) of nasopharyngeal carcinoma. Methods A total of 150 nasopharyngeal carcinoma patients in Meizhou People's Hospital from December 2014 to November 2016 were treated by image-guided radiation therapy (IGRT), kV-KBCT, CT image scanning matcthed by bone and grey alignment. PTV of nasopharyngeal carcinoma was also calculated. Results According to PTV formula, the external distance before radiotherapy guided by grey alignment was 0.5 mm in X-axis, 0.4 mm in Y-axis, 0.8 mm in Z-axis. While the distance was 0.1 mm in X-axis, 0.5 mm in Y-axis, 1.7 mm in Z-axis guided by bone alignment. After radiotherapy, the external distance guided by grey alignment was 0.4 mm in X-axis, 0.5 mm in Y-axis, 0.9 mm in Z-axis. While the distance was 0.1 mm in X-axis, 0.9 mm in Y-axis, 2.0 mm in Z-axis guided by bone alignment. There was no significant difference in set-up errors of 3 directions and 2 aligned ways before and after treatment.Conclusions The PTV within 3 mm is safe when IGRT is used for directing radiotherapy of nasopharyngeal carcinoma,and kV-KBCT is an effective image equipment.

18.
Chinese Journal of Radiation Oncology ; (6): 500-503, 2018.
Artigo em Chinês | WPRIM | ID: wpr-708223

RESUMO

Objective To explore the importance of head fixation in chest wall field combined with supraclavicular field radiotherapy for breast cancer by comparing the displacement error and dosimetric differences caused by multi-functional body board and breast bracket.Methods Thirty patients with breast cancer were randomly divided into groups A and B.In group A,patients were fixed with multi-functional body board and head thermoplastic film.In group B,patients were fixed with traditional breast brackets.Each patient received CBCT scan before and after radiotherapy.Both setup errors and intra-fractional displacements in the x-,y-and z-axis,V100 and V95 were calculated.Statistical analyses were performed using the independent sample t-test.Results The displacement errors in groups A and B before and after radiotherapy were (1.24± 0.42),(1.71± 0.61) and (2.25± 1.04) mm vs.(3.67± 2.05),(3.78± 1.74),(4.65±2.66) mm in the x-,y-and z-axis,respectively (P=0.033,0.027,0.020).The intra-fractional displacements in groups A and B were (1.10±0.66),(1.13±0.59),(1.11 ±0.62) mm vs.(2.48±0.88),(2.21 ±0.98),(3.53±2.01) mm in the x-,y-and z-axis,respectively (P=0.030,0.021,0.013).The V100 in groups A and B were (94.27± 3.20) % and (99.08± 0.60) % (P =0.065),and (89.48± 4.70) % and (96.53± 2.50) % for V95 (P =0.002),respectively.Conclusion The risk of displacement error is significantly reduced using multi-functional body board,which enhances the accuracy of radiation dose in chest wall and supraclavicular fields of breast cancer patients.

19.
Chinese Journal of Radiation Oncology ; (6): 267-270, 2018.
Artigo em Chinês | WPRIM | ID: wpr-708179

RESUMO

Objective Image-guided radiation therapy(IGRT)was performed to investigate the intrafractional body motion and identify the relevant influencing factors during hypofractionated radiotherapy for malignant pulmonary tumors. Methods A total of ninety-six patients with malignant pulmonary tumors receiving hypofractionated radiotherapy in Jiangsu Cancer Hospital were enrolled in this clinical trial. The kilo-voltage cone beam CT(kV-CBCT)was acquired prior to each fraction and matched to the planning CT images to correct the set-up errors. CBCT was performed immediately after the end of treatment to evaluate the intrafractional variation in the mediolateral,anteroposterior and craniocaudal dimensions.The relationship between relevant influencing factors and intrafractional variation was analyzed using multivariate linear regression. Results In the anteroposterior and craniocaudal directions,the intrafractional positioning errors were reduced along with the increase of ordinal number of fraction(P= 0.000). In the mediolateral direction, the intrafractional positioning errors were increased along with the longer duration of hypofractionated radiotherapy(P=0.010).The intrafractional positioning errors were decreased over larger body weight(P=0.003).The intrafractional positioning errors were significantly increased when vacuum bag and thermoplastic film were utilized for fixation(P= 0.009). Conclusions Certain intrafractional positioning errors occur during hypofractionated radiotherapy. Relevant influencing factors differ in different directions. Relevant influencing factors should be modified to reduce intrafractional positioning variation and improve the treatment accuracy.

20.
Chinese Journal of Radiological Medicine and Protection ; (12): 830-835, 2018.
Artigo em Chinês | WPRIM | ID: wpr-708142

RESUMO

Objective To explore the CTV to PTV external expansion boundary and the effect of the dose of normal lung tissue under different fixed modes by a comparative analysis of combined body position and thermoplastic film fixed set-up error of radiation therapy for lung cancer. Methods From October 2016 to March 2018, the patients who received chest radiology at the Tangshan people's hospital were enrolled as subjects retrospectively divided into two groups, including 50 patients with lung cancer radiotherapy with combined body position fixation, and 40 patients with lung cancer with thermoplastic film fixation. The two groups of patients drew the target areas in accordance with the unified standard, and the set-up error of left and right, up and down, front and rear ( x, y, z axis) were recorded respectively after 1 time/week cone CT( CBCT) matched with the planned CT image and analyzed by t test. According to the MPTV =2. 5Σ+0. 7δ, CTV to PTV external expansion boundary in the combined body position group were calculated. And the V5、V20 and V30 of two groups of patients were calculated and analyzed by TPS system. Results The set-up error of the combined body position group and thermoplastic film group were respectively (1. 00 ± 0. 58) mm and (3. 28 ± 0. 43) mm on the x axis, (1. 42 ± 0. 28) mm on the y axis and (4. 03 ± 0. 41) mm, (1. 06 ± 0. 44) mm and (3. 18 ± 0. 34) mm on the z axis. The set-up errors of the two groups were statistically significant on x, y and z axis( t= -20. 740, -35. 596, -25. 015,P<0. 05). There was no significant difference in set-up errors between the central and peripheral lung cancer patients and between left and right lung cancer patients(P>0. 05). Through the MPTV =2. 5Σ+0. 7δ, CTV to PTV external expansion boundary in the combined body position fixation group was 2. 906 , 3. 746 and 2. 958 mm on x, y and z axis respectively. The comparison between group A and B showed that the mean values of V5 , V20 and V30 in group B were reduced by 1. 5%, 3. 1% and 4. 8% respectively compared with group A. Conclusions The combined body position technique can improve the accuracy of lung cancer patients after radiation therapy,and further reduce the boundary of CTV to PTV, which is of certain value to reduce the occurrence of radiation pneumonitis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA