Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 191
Filtrar
1.
International Journal of Biomedical Engineering ; (6): 42-47, 2023.
Artigo em Chinês | WPRIM | ID: wpr-989314

RESUMO

Objective:To investigate the effects of shear stress magnitude and exposure time on the damage of blood component erythrocytes and von willebrand factor (VWF) based on microfluidic technology.Methods:A blood shear platform was built based on a microfluidic chip, samples were prepared under different shear stress magnitudes and exposure time lengths, free hemoglobin assay experiments were performed on blood samples, the hemolysis indices of different samples were measured, and the relative molecular masses of different samples of VWF were analyzed by immunoblotting and chemiluminescence imaging.Results:The quantitative relationships between the hemolysis index and the degradation rate of high relative molecular mass VWF with shear stress and exposure time followed the power function model well.Conclusions:The microfluidic experimental platform has the advantages of a precise and controllable internal microenvironment and easy and rapid detection, which can be used for the quantitative study of blood damage patterns.

2.
Journal of Medical Biomechanics ; (6): E627-E634, 2023.
Artigo em Chinês | WPRIM | ID: wpr-987996

RESUMO

Long-term exposure to risk factors will lead to coronary atherosclerosis, which will lead to the formation and progression of coronary plaque. Early identification of high-risk plaque characteristics will help prevent plaque rupture or erosion, thus avoiding the occurrence of acute cardiovascular events. Biomechanical stress plays an important role in progression and rupture of atherosclerotic plaques. In recent years, non-invasive coronary computed tomography angiography (CCTA) computational fluid dynamics (CFD) modeling has made it possible to acquire the corresponding biomechanical stress parameters. These coronary biomechanical stress parameters, especially wall shear stress (WSS), will aid in the development of a more accurate clinical model for predicting plaque progression and major adverse cardiovascular events ( MACE ). In this review, the biomechanical stress and the role of WSS from CCTA in atherosclerosis were introduced, and the researches on the relationship between biomechanical stress from CCTA and coronary artery diseases were discussed.

3.
Journal of Medical Biomechanics ; (6): E608-E614, 2023.
Artigo em Chinês | WPRIM | ID: wpr-987993

RESUMO

Objective To observe the inhibitory effect of Tirofiban on different shear-induced platelet aggregation, and to provide medication suggestions for the treatment of thrombosis in different hemodynamic environment. Methods Polydimethylsiloxane ( PDMS)-glass microchannel chips were fabricated by soft lithography. The whole blood of healthy volunteers anticoagulated with sodium citrate was collected and incubated with different concentrations of Tirofiban in vitro. The blood flowed through the straight microchannel or channel with 80% narrow for 150 seconds at the speed of 11 μL/ min and 52 μL/ min, respectively. The wall shear stress rates in straight channel at 11 μL/ min and 52 μL/ min were 300 s-1 and 1 500 s-1, respectively. The maximum wall shear rates in the channel with 80% occlusion at 11 μL/ min and 52 μL/ min were 1 600 s-1 and 7 500 s-1, respectively. The adhesion and aggregation images of fluorescent labeled platelets on glass surface were photographed with the microscope, and the fluorescent images were analyzed with Image J. The platelet surface coverage ratio was used as a quantitative index of platelet aggregation behavior, and the IC50 of Tirofiban for platelet inhibition was calculated under different shear rates. Flow cytometry was used to detect the platelet activation index (CD62P, PAC-1) in the whole blood at 52 μL/ min in channel with 80% occlusion. Results Tirofiban inhibited platelet aggregation in a dose-dependent manner, and the inhibitory effect was related to the shear rate. Under the shear rates of 11 μL/ min and 52 μL/ min, the aggregation was almost completely inhibited when the concentration in straight channel reached 100 nmol / L. When the concentration in channels with 80% occlusion reached 1 μmol / L, the aggregation was almost completely inhibited. IC50 values at 11 μL/ min and 52 μL/ min in straight channel were 2. 3 nmol / L and 0. 5 nmol / L, respectively. IC50 values at 11 μL/ min and 52 μL/ min in channels with 80% occlusion were 20. 73 nmol / L and 4. 5 nmol / L. Pathologically high shearforce induced an increase in platelet activation, which could be inhibited by Tirofiban. Conclusions Tirofiban can effectively inhibit shear-induced platelet aggregation, and different concentrations of Tirofiban should be given according to the thrombus formed in different shear force environment in clinic practice

4.
Journal of Medical Biomechanics ; (6): E268-E275, 2023.
Artigo em Chinês | WPRIM | ID: wpr-987946

RESUMO

Objective To explore the role of miR-199a-3p in osteoblast proliferation induced by fluid shear stress (FSS) and the potential molecular mechanism. Methods Osteoblast MC3T3-E1 was treated with 1. 2 Pa FSS with time gradients of 0, 15, 30, 45, 60, 75 and 90 min, respectively. MC3T3-E1 cells were transfected with miR-199a-3p mimic or miR-199a-3p inhibitor. MC3T3-E1 cells were transfected with miR-199a-3p mimic and itsnegative control and then treated with 1. 2 Pa FSS for 45 min. The pc DNA NC, pc DNA-CABLES -1, si RNA NC and si RNA CABLES-1 were transfected into MC3T3-E1 cells. The pc DNA-CABLES-1 and mir-199a-3p mimic and SI NA-cables-1 and miR-199a-3p inhibitor were co-transfected, respectively. Cell activity was detected by CCK-8 assay. Real-time quantitative PCR (RT-qPCR) was used to detect expression levels of CABLES-1, miR-199a-3p, CDK 6, Cyclin D1 and PCNA. Luciferase reporting assay was used to detect targeting relationship between CABLES-1 and miR-199a-3p. Immunofluorescence was used to detect protein expression of CABLES-1.Western blot was used to detect protein expression of CABLES-1, CDK 6, PCNA and Cyclin D1. Results Mir- 199a-3p in MC3T3-E1 cells was significantly down-regulated by FSS. Over-expressed miR-199a-3p inhibitedosteoblast proliferation, and down-regulated miR-199a-3p expression promoted osteoblast proliferation. miR-199a- 3p could reverse the FSS-induced proliferation in osteoblasts. Dual luciferase assay showed that miR-199a-3p targeted to CABLES-1 and over-expressed miR-199a-3p inhibited expression of CBALES-1 protein. CABLES-1 could promote proliferation of osteoblasts. miR-199a-3p inhibited osteoblast proliferation induced by FSS through CABLES-1. Conclusions FSS-induced osteoblast proliferation can be realized by down-regulated miR-199a-3p expression via targeting CABLES-1. The findings in this study provide new direction for researches on mechanism of FSS-induced osteoblast proliferation, as well as new ideas for future research on clinical application of mechanical loading in the treatment of bone and joint diseases.

5.
Journal of Medical Biomechanics ; (6): E220-E227, 2023.
Artigo em Chinês | WPRIM | ID: wpr-987939

RESUMO

Objective To explore how hyaluronic acid ( HA) in extracellular matrix regulates the adhesion ofCD44+tumor cells. Methods MDA-MB-231 cells or HL60 cells were perfused in a parallel plate chamber. Themovement of cells over immobilized HA was observed and analyzed to obtain the characteristics of cell adhesionand rolling. Results The adhesion number of MDA-MB-231 cells on HA substrate was positively regulated by HAconcentration, but not by HA molecular weight. Compared with physically adsorbed HA, immobilized HA byavidin-biotin could significantly improve the cell adhesion ratio. With the increase of shear stress in the range of30-50 mPa, the rolling velocity of cells increased and the adhesion ratio decreased, but the tether lifetime of cellswas not affected. In the same flow field, compared with MDA-MB-231 cells, HL60 cells with low expression ofCD44 rolled more quickly on immobilized HA, with shorter tether lifetime and much lower adhesion ratio(<1. 5% ). Conclusions Fluid shear stress might mediate the rolling velocity of MDA-MB-231 cells by regulatingthe CD44-HA association rate rather than their dissociation rate. The interaction between CD44 and HA is involved in the initial adhesion of HL60 cells, but it does not play a major role. This study will provide references for the design of anti-tumor drugs.

6.
Journal of Medical Biomechanics ; (6): E116-E122, 2023.
Artigo em Chinês | WPRIM | ID: wpr-987923

RESUMO

Objective To propose a two-way fluid-structure interaction (FSI) method based on real patients with carotid artery stenosis, and analyze the hemodynamic parameters of carotid plaques with different types at the lesion as well as deformation and stress changes of the plaque itself. Methods Three-dimensional ( 3D) modeling was performed based on computed tomography angiography ( CTA) data of patients with moderate carotid artery stenosis. The carotid artery wall model and plaque model were separated, and transient fluid structure coupling calculation was performed. The situation from early stage of carotid atherosclerosis to formation of the plaque was simulated. The plaque types were divided into thickened plaques, lipid plaques, mixed plaques and calcified plaques, among which thickened plaques were regarded as non-plaque conditions for representing the thickening of vascular intima-media. The stenotic carotid arteries with different plaque types were compared and analyzed. Results The plaques with different types had little effect on the overall blood flow, but the wall shear stress of lipid plaques at the lesion was lower than that of other plaques. With thickened plaques as a control, concurrence of the plaque would inhibit artery expansion, and lipid plaques were the most obvious. Calcified plaques had the highest average plaque structure stress, while lipid plaques had the lowest average plaque structure stress. Conclusions The method proposed in this study can analyze fluid area and solid area at the same time. The results can contribute to better understanding the influence of different plaque types on carotid artery diseases.

7.
Archives of Orofacial Sciences ; : 125-137, 2023.
Artigo em Inglês | WPRIM | ID: wpr-1016734

RESUMO

@#This study aimed to investigate the irrigation dynamics of the positive pressure side-vented (SV) needle, EndoVac (micropores) needle and modified apical negative pressure (mANP) open-ended needle using computational fluid dynamics (CFD). A simulation of a prepared root canal (conical frustum) of 15 mm length with an apical diameter of 0.40 mm following Protaper F4 apical preparation was created using three-dimensional (3D) CAD software. The 3D simulated needle of SV 30G needle, EndoVac with micropores needle and mANP, 30G flat open-ended needle were also created. The irrigation dynamics were evaluated through transient CFD simulations. In addition, the irrigation dynamics of mANP at 0.2 mm, 0.5 mm, and 1.0 mm short from the working length were also assessed. The EndoVac and mANP showed negative apical static pressure and streamline patterns able to reach the apical region, thus indicating negligible extrusion. Meanwhile, SV showed positive apical static pressure and almost nonexistent streamlines beyond the needle tip. The SV showed the highest wall shear stress (WSS) magnitude of 1030Pa whereas Endovac (161 Pa) and mANP1 (258 Pa). However, SV revealed lower average WSS (10 Pa) compared to mANP1 (13 Pa) and mANP2 (11 Pa). This is due to SV developed a localised maximum WSS opposite the open vent area only therefore, uneven distribution of WSS. The EndoVac system developed a localised maximum WSS in the pair of micropores furthest away from the apical. CFD analysis of the EndoVac, mANP and SV showed different technique approach, needle design and needle depths insertion affect the irrigation dynamics pattern and magnitude.

8.
Acta Anatomica Sinica ; (6): 546-552, 2023.
Artigo em Chinês | WPRIM | ID: wpr-1015183

RESUMO

[Abstract] Objective To explore the effect of different modes of blood flow shear stress on the Pim1 expression in human umbilical vein endothelial cells (HUVECs) and the regulation of phosphorylation at Ser1177 and Ser633 of endothelial nitric oxide synthase (eNOS). Methods HUVECs were isolated from fresh human umbilical cord. The parallel plate flow chamber system was used to load 15 dyn/ cm

9.
China Journal of Orthopaedics and Traumatology ; (12): 1207-1210, 2023.
Artigo em Chinês | WPRIM | ID: wpr-1009213

RESUMO

Hoffa fracture is an unstable intra-articular fracture with significant redisplacement tendency. It is easy to be missed diagnosis when accompanied by distal intercondylar or supracondylar fracture of femur. CT scan is the gold standard for the diagnosis of Hoffa fracture. The treatment principles are anatomic reduction of the articular surface, reliable internal fixation, and early functional activity. At present, the main treatment is arthroscopic screw fixation. During screw fixation, the tail cap of screw should be buried, resulting in non-healing iatrogenic injury of articular cartilage. In the early postoperative functional activity of knee joint, fracture block was repeatedly subjected to backward and upward shear force under the action of the tibial plateau, which is the main reason for the failure of internal fixation. Plate assisted screw fixation could increase local mechanical stability, but it still cannot avoid the defects of iatrogenic cartilage injury. At the same time, plate molding is required during the operation due to the absence of special anatomical plates, resulting in increased surgical trauma and time-consuming surgery. The ideal fixation method for Hoffa fracture should include:(1) Avoid iatrogenic injury of articular surface cartilage. (2) With the rear anti-shear barrier plate function.(3) The internal fixator is closer to the load interface, so as to obtain greater load and better fixed strength.


Assuntos
Humanos , Fratura de Hoffa , Fraturas do Fêmur/cirurgia , Tomografia Computadorizada por Raios X , Fixação Interna de Fraturas/métodos , Placas Ósseas , Doença Iatrogênica
10.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 1485-1491, 2022.
Artigo em Chinês | WPRIM | ID: wpr-953546

RESUMO

@#Objective    To discuss the feasibility of establishment of animal model of "functional" bicuspid aortic valve with swine and observe its effect on the wall shear stress inside the aorta. Methods    Four common Shanghai White Swine with body weight between 50 kg to 55 kg were selected. Under general anesthesia and cardiopulmonary bypass, the aortic transverse incision approach was used, continuous suture with 6-0 polypropylene to align the left and right coronary valve leaflets to create a bicuspid valve morphology. After the operation, echocardiography was used to observe the aortic valve morphology and the hemodynamic changes of the aortic valve orifice. The effect on the wall shear stress inside the aorta was studied with 4D-Flow magnetic resonance imaging (MRI). Results    A total of 4 swine "functional" bicuspid aortic valve models were established, with a success rate of 100.0%. Echocardiography showed that the blood flow velocity of the aortic valve orifice was faster than that before the operation (0.96 m/s vs. 1.80 m/s). 4D-Flow MRI showed abnormally increased wall shear stress and blood flow velocity in the aorta of the animal models. After the surgery, in model animals, the maximal wall shear stress inside the ascending aorta was greater than 1.36 Pa, and the maximum blood flow velocity was greater than 1.4 m/s. Conclusion    Establishment of the animal model of "functional" bicuspid aortic valve in swine is feasible, scientific and reliable. It can be used in researches on evaluating the pathophysiological changes.

11.
Chinese Journal of Neurology ; (12): 612-618, 2022.
Artigo em Chinês | WPRIM | ID: wpr-933829

RESUMO

Objective:To investigate the relationship between wall shear stress (WSS) and the degree of lumen stenosis and plaque characteristics in patients with atherosclerotic stenosis in the middle brain.Methods:Thirty-four patients with moderate to severe unilateral middle cerebral artery stenosis in Nanjing First Hospital from June 2020 to June 2021 were analyzed retrospectively. All patients underwent routine magnetic resonance imaging and vascular wall imaging to obtain plaque parameters such as plaque area, remodeling mode and remodeling index. Based on magnetic resonance angiography, a computational fluid dynamics model was established to simulate the local hemodynamics near the lesion and quantify WSS. The patients were divided into high WSS group and low WSS group according to the median WSS. The differences of clinical baseline data, degree of lumen stenosis and plaque characteristics between the two groups were compared. Pearson correlation analysis was used to calculate the correlation between WSS and lumen stenosis and plaque characteristics.Results:A total of 34 patients were included in this study, 17 in the high WSS group and 17 in the low WSS group. Compared with the low WSS group, the plasma homocysteine level in the high WSS group was lower [(11.10±4.96) μmol/L vs (16.97±6.98) μmol/L, t=-2.83, P=0.010], the degree of stenosis was lower (0.56±0.05 vs 0.66±0.08, t=-4.54, P<0.001), and the proportion of positive lumen remodeling was higher (12/17 vs 4/17, P=0.015). Pearson correlation analysis showed that the degree of lumen stenosis was negatively correlated with WSS ( r=-0.44, P=0.011), and the plaque area was not correlated with WSS. Conclusions:WSS in middle cerebral artery stenosis is related to the degree of lumen stenosis and the mode of vascular remodeling. Higher WSS has poor stability, but lower WSS is more likely to cause lumen stenosis.

12.
Journal of Medical Biomechanics ; (6): E699-E705, 2022.
Artigo em Chinês | WPRIM | ID: wpr-961788

RESUMO

Objective To study von Willebrand factor(VWF) damage based on a novel Maglev Taylor-Couette blood-shearing device. Methods The magnetic levitation (maglev) Taylor-Couette blood-shearing device was designed, and the blood-shearing platform was built. Fresh porcine blood was tested in circulation loop for 1 hour at laminar flow state. VWF damage was assessed by analyzing sample through Western blot and enzyme-linked immunosorbent assay. Results With the increase of exposure time and shear stress, a large number of high molecular weight VWF multimers were degraded into low molecular weight VWF. The maximum rate of degradation was 569%. When the shear stress increased from 18 Pa to 55 Pa, the ratio of VWF-Rco to VWF-Ag decreased from 45.7% to 32.8%. ConclusionsCompared with initial sample, the VWF damage was mainly manifested by the decrease of high molecular weight VWF and the decrease of VWF activity, and VWF-Ag did not change significantly. The novel maglev Taylor-Couette blood-shearing device can quantitatively control the flow parameters (exposure time and shear stress), and be used for blood damage research in vitro, thus providing references for the design and optimization of extracorporeal membrane oxygenation and blood pump.

13.
Journal of Medical Biomechanics ; (6): E200-E210, 2022.
Artigo em Chinês | WPRIM | ID: wpr-961712

RESUMO

Bone defects have always been an important cause of threat to human health, and artificial biomimetic bone repair replacement materials are currently one of the most effective and feasible solution approaches to treat bone damage. To develop artificial bone biomimetic materials, an in vitro biomimetic mineralization system must be constructed first to study in vitro biomimetic mineralization mechanism of natural bone matrix. Collagen is a template for mineralization, and its properties such as crosslinking degree, diameter, osmotic pressure, and surface charge can all directly affect mineralization progress. The biochemical and mechanical environments in which mineralization occurs are also quite distinct in their effects on mineralization process, particularly noncollagenous proteins and fluid shear stress (FSS). FSS is considered to be the main mechanical stimulation of bone tissues in micro-environment, which is of great significance to bone growth, repair and health maintenance. FSS at different levels and loading regimes has significant effects on transformation of amorphous calcium phosphate to bone apatite, self-assembly and directional alignment of collagen fibrils, and formation of hierarchical intrafibrillar mineralization. In this paper, the factors affecting collagen mineralization and their mechanism were summarized, with focus on regulation of FSS on collagen mineralization, and development direction in future was also prospected.

14.
Journal of Biomedical Engineering ; (6): 339-346, 2022.
Artigo em Chinês | WPRIM | ID: wpr-928230

RESUMO

To explore the influence of bionic texture coronary stents on hemodynamics, a type of bioabsorbable polylactic acid coronary stents was designed, for which a finite element analysis method was used to carry out simulation analysis on blood flow field after the implantation of bionic texture stents with three different shapes (rectangle, triangle and trapezoid), thus revealing the influence of groove shape and size on hemodynamics, and identifying the optimal solution of bionic texture groove. The results showed that the influence of bionic texture grooves of different shapes and sizes on the lower wall shear stress region had a certain regularity. Specifically, the improvement effect of grooves above 0.06 mm on blood flow characteristics was poor, and the effect of grooves below 0.06 mm was good. Furthermore, the smaller the size is, the better the improvement effect is, and the 0.02 mm triangular groove had the best improvement effect. Based on the results of this study, it is expected that bionic texture stents have provided a new method for reducing in-stent restenosis.


Assuntos
Biônica , Simulação por Computador , Vasos Coronários , Hemodinâmica/fisiologia , Modelos Cardiovasculares , Stents , Estresse Mecânico
15.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 1-7, 2021.
Artigo em Chinês | WPRIM | ID: wpr-906198

RESUMO

Objective:To investigate the effect of Danggui Buxuetang(DGBX)on the functional activity of rat endothelial progenitor cells(EPCs)exposed to different luminar shear stress (SS). Method:EPCs isolated from rat bone marrow were incubated on a parallel plate flow chamber at a steady SS of 0, 0.12, 1.2, 2.4 Pa for 6 h,then the cells exposed to different SS were randomly divided into 8 groups: control group (perfused with serum free medium),simvastatin group(0.1 μmol·L<sup>-1 </sup>simvastatin),3 DGBX groups(low,medium,high-dose DGBX)and 3 inhibitor groups(3 DGBX groups with LY294002). After 12 h,the samples were collected for the detection of cell proliferation ,migration,tubule formation ,the secretion of nitric oxide (NO) ,and the expressions of endothelial nitric oxide synthase(eNOS) mRNA and protein kinase B(Akt),respectively. Result:Compared with the control group,simvastatin and DGBX(high-dose)could both promote the functional activities and NO secretion,and up-regulate the expressions of eNOS mRNA and Akt protein in EPCs exposed to different SS(<italic>P</italic><0.05),while DGBX(mid-dose)could do these only at 0 Pa. However,LY294002 could inhibit all effects of DGBX on EPCs. Conclusion:SS seems to play an important role in the effect of DGBX on EPCs,and DGBX could promote the functional activity of EPCs exposed to SS by up-regulating the expressions of NO/eNOS/Akt.

16.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 234-242, 2021.
Artigo em Chinês | WPRIM | ID: wpr-906042

RESUMO

Cells in the arterial wall are constantly subjected to the shear stress generated by the blood flow. Shear stress plays a pivotal role in the formation of atherosclerosis. The endothelial cells located between the blood and the vessel wall have a unique response to the shear stress of the blood flow, which can convert mechanical stimulation into intracellular signals, thereby affecting the pathological process of atherosclerosis. Endothelial function is not only regulated by hormones, growth factors and other biochemical substances, but also affected by mechanical forces such as blood flow shear stress. Physiologically, shear stress can play an anti-atherosclerotic role in maintaining the homeostasis of endothelial cells. Pathological shear stress will lead to endothelial dysfunction and promote the progression of atherosclerosis. Under the mediation of different shear stress, the endothelial function can be regulated through epigenetic pathways or mechanically sensitive cation channels. Therefore, it is necessary to understand how various signal transduction pathways are affected by pathological shear stress, so as to cause endothelial dysfunction and atherosclerosis. Traditional Chinese medicine(TCM) has been increasingly recognized for its curative effect in treating atherosclerosis, with the advantages of few side effects, multiple targets and multiple mechanisms. In recent years, the understanding of the anti-atherosclerosis mechanism of TCM mediated by shear stress has gradually deepened. This review will take endothelial function as the breakthrough point, systematically sort out the influence of shear stress on the pathological process of atherosclerosis and the related molecular mechanisms. Meanwhile, it is the first time to summarize the latest research progress of Chinese medicine against shear stress damage by sorting out the existing literature. This article mainly clarify the relationship between shear stress, endothelial function, atherosclerosis and TCM, in order to provide a theoretical basis for the clinical treatment and pathological mechanism of atherosclerosis.

17.
Journal of Medical Biomechanics ; (6): E646-E651, 2021.
Artigo em Chinês | WPRIM | ID: wpr-904450

RESUMO

Objective To evaluate the damage of von Willebrand factor (vWF) induced by shear stress in BPX-80 centrifugal blood pump, and determine whether it can be used as a reference pump for vWF damage research. Methods An in vitro hemolysis test platform was established according to the ASTM standards. The BPX-80 centrifugal blood pump was tested for 8 hours by using fresh porcine blood. The hemolysis level and vWF damage of hourly blood samples were then evaluated and compared with the static control group. ResultsThe hemolysis index of BPX-80 was stable and low during the test; vWF polymer with high molecular weight had a small amount of degradation, and showed no significant difference compared with the static control group; there was no significant change in the concentration of vWF antigen, which was basically consistent with the trend of the static control group. Conclusions BPX-80 centrifugal blood pump has good blood compatibility and can be used as the reference pump for vWF damage and hemolysis evaluation, thereby providing guidance for the design and optimization of new blood pumps.

18.
Journal of Medical Biomechanics ; (6): E560-E567, 2021.
Artigo em Chinês | WPRIM | ID: wpr-904438

RESUMO

Objective To study the influence of skull thickness on intracranial biomechanical parameters by finite element method. Methods The female head at 5th percentile was selected for CT scanning to construct finite element model of the head with high biofidelity,and the model was verified by reconstructed cadaver test. The finite element model of the head with different skull thickness was established, and multiple groups of tests were carried out to compare the intracranial mechanical parameters. Results The negative value of intracranial pressure was significantly affected by the decrease in skull thickness under the same head size, while the negative value of intracranial pressure was slightly affected, with an increasing trend. The shear stress and von Mises stress of brain tissues were significantly increased with skull thickness increasing. Conclusions Under the same head size, the skull thickness will affect head injury to a certain extent, and people with small skull thickness are more likely to be injured than those with large skull thickness.

19.
International Eye Science ; (12): 1333-1338, 2021.
Artigo em Chinês | WPRIM | ID: wpr-882088

RESUMO

@#AIM:To observe the changes of the vessel density of choriocapillaris in lens-induced myopia in guinea pigs, and to explore choroidal endothelin-1(ET-1), endothelin receptor A(ETAR)and receptor B(ETBR)expression changes and the effect of electroacupuncture. <p>METHODS: Fifty-four guinea pigs were randomly divided into normal control(NC), lens-induced myopia(LIM)and LIM+electroacupuncture(LIM+EA). The NC group was fed normally without intervention and the right eye in LIM group and LIM+EA group was coverd with a -6.00D lens to establish a myopia model. At 2 and 4wk, the refraction, axial length and the vessel density of choriocapillaris in groups were measured. The expression and protein content of ET-1, ETAR and ETBR mRNA in groups were detected by the real-time fluorescent quantitative PCR(quantitative polymerase chain reaction, q-PCR), enzyme-linked immunosorbent assay(ELISA)and immunohistochemistry. <p>RESULTS: At 2 and 4wk, compared with the the NC group, refraction and axial length in LIM group and LIM+EA group had significantly increased(all <i>P</i><0.001). Compared with the LIM group, the refraction and axial length in LIM+EA group were decreased(all <i>P</i><0.05). At 2 and 4wk, compared with the NC group,the vessel density of choriocapillaris was decreased(<i>P</i><0.001)and the ET-1, ETAR and ETBR mRNA and protein levels in choroid were increased(all <i>P</i><0.05)in LIM group. At 2 and 4wk, compared with the LIM group,the vessel density of choriocapillaris was decreased(<i>P</i><0.01)and the ET-1, ETAR and ETBR mRNA and protein levels in choroid were increased in LIM+EA group.<p>CONCLUSION:In LIM guinea pigs, the choroidal blood flow decreased with the increased of refraction and axial length, which may affect ET-1 and its receptors through vascular shear force during the development of myopia. At the same time, electroacupuncture can improve choroidal blood flow through neuromodulation and affects the vascular shear stress to down-regulate the content of ET-1 and its receptor to delay the development of myopia.

20.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 35-41, 2020.
Artigo em Chinês | WPRIM | ID: wpr-873215

RESUMO

Objective:To observe the effect of modified Tongqiao Huoxuetang on circulating blood flow and wall shear stress of vertebrobasilar dolichoectasia (VBD) due to blood stasis and channel blockage. Method:A total of 97 patients admitted in our department from October 2017 to August 2019 were collected. The traditional Chinese medicine (TCM) syndromes were consistent with blood stasis and channel blockage, and diagnosed as VBD by magnetic resonance angiography (MRA). The patients were divided into experimental group (48 cases) and control group (49 cases). Control group was given basic therapy and placebo of TCM, while treatment group was given basic therapy and modified Tongqiao Huoxuetang for 30 days. The degree of relief of vertigo symptoms, vertigo symptom scale (VSS), activity balance confidence (ABC), transcranial doppler (TCD) bilateral vertebral artery and basilar artery blood flow velocity [systolic blood flow velocity (Vs), mean blood flow velocity (Vm), diastolic blood flow velocity (Vd)], mean blood flow differences between (MFV), pulsatility index, resistance index (RI), and wall shear force (WSS) were observed before and after treatment. Result:Compared with control group before treatment, the score of ABC scale in control group after treatment was markedly higher, while the score of VSS was significantly lower (P<0.05). However, there was no statistical significance in the score of vertigo symptom. Compared with treatment group before treatment, the symptom grade of vertigo degree and the score of VSS in treatment group after treatment were substantially lower, while the score of ABC scale was significantly higher (P<0.05). Compared with control group, the score of vertigo degree symptoms and VSS in treatment group were markedly lower, while the score of ABC scale was significantly higher (P<0.05). Compared with control group before treatment, Vm, MFV and WSS of bilateral vertebral artery in control group after treatment were substantially higher, while RI was significantly lower (P<0.05). However, there were no statistical significances in Vs, Vd and PI in control group before and after treatment. Compared with treatment group, Vs, Vd, Vm, MFV and WSS of bilateral vertebral artery in treatment group after treatment were markedly higher, while RI was significantly lower (P<0.05). However, there was no statistical significance in PI of experimental group before and after treatment. Compared with control group after treatment, Vs, Vd, Vm, MFV and WSS of bilateral vertebral artery in treatment group after treatment were substantially higher, while there was no statistical significance in PI and RI. Before and after treatment, there were similar changes in blood flow parameters of the basilar artery and bilateral vertebral artery. Conclusion:Modified Tongqiao Huoxuetang could improve the clinical symptoms of dizziness or vertigo in patients of VBD due to blood stasis and channel blockage, and the mechanism might be related to the improvement of post-circulation hemodynamics by Tongqiao Huoxuetang.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA