Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Biomedical Engineering ; (6): 893-902, 2021.
Artigo em Chinês | WPRIM | ID: wpr-921827

RESUMO

Breathing pattern parameters refer to the characteristic pattern parameters of respiratory movements, including the breathing amplitude and cycle, chest and abdomen contribution, coordination, etc. It is of great importance to analyze the breathing pattern parameters quantificationally when exploring the pathophysiological variations of breathing and providing instructions on pulmonary rehabilitation training. Our study provided detailed method to quantify breathing pattern parameters including respiratory rate, inspiratory time, expiratory time, inspiratory time proportion, tidal volume, chest respiratory contribution ratio, thoracoabdominal phase difference and peak inspiratory flow. We also brought in "respiratory signal quality index" to deal with the quality evaluation and quantification analysis of long-term thoracic-abdominal respiratory movement signal recorded, and proposed the way of analyzing the variance of breathing pattern parameters. On this basis, we collected chest and abdomen respiratory movement signals in 23 chronic obstructive pulmonary disease (COPD) patients and 22 normal pulmonary function subjects under spontaneous state in a 15 minute-interval using portable cardio-pulmonary monitoring system. We then quantified subjects' breathing pattern parameters and variability. The results showed great difference between the COPD patients and the controls in terms of respiratory rate, inspiratory time, expiratory time, thoracoabdominal phase difference and peak inspiratory flow. COPD patients also showed greater variance of breathing pattern parameters than the controls, and unsynchronized thoracic-abdominal movements were even observed among several patients. Therefore, the quantification and analyzing method of breathing pattern parameters based on the portable cardiopulmonary parameters monitoring system might assist the diagnosis and assessment of respiratory system diseases and hopefully provide new parameters and indexes for monitoring the physical status of patients with cardiopulmonary disease.


Assuntos
Humanos , Pulmão , Doença Pulmonar Obstrutiva Crônica , Respiração , Volume de Ventilação Pulmonar , Dispositivos Eletrônicos Vestíveis
2.
Journal of Biomedical Engineering ; (6): 131-137, 2021.
Artigo em Chinês | WPRIM | ID: wpr-879258

RESUMO

As a novel technology, wearable physiological parameter monitoring technology represents the future of monitoring technology. However, there are still many problems in the application of this kind of technology. In this paper, a pilot study was conducted to evaluate the quality of electrocardiogram (ECG) signals of the wearable physiological monitoring system (SensEcho-5B). Firstly, an evaluation algorithm of ECG signal quality was developed based on template matching method, which was used for automatic and quantitative evaluation of ECG signals. The algorithm performance was tested on a randomly selected 100 h dataset of ECG signals from 100 subjects (15 healthy subjects and 85 patients with cardiovascular diseases). On this basis, 24-hour ECG data of 30 subjects (7 healthy subjects and 23 patients with cardiovascular diseases) were collected synchronously by SensEcho-5B and ECG Holter. The evaluation algorithm was used to evaluate the quality of ECG signals recorded synchronously by the two systems. Algorithm validation results: sensitivity was 100%, specificity was 99.51%, and accuracy was 99.99%. Results of controlled test of 30 subjects: the median (Q1, Q3) of ECG signal detected by SensEcho-5B with poor signal quality time was 8.93 (0.84, 32.53) minutes, and the median (Q1, Q3) of ECG signal detected by Holter with poor signal quality time was 14.75 (4.39, 35.98) minutes (Rank sum test,


Assuntos
Humanos , Algoritmos , Eletrocardiografia , Eletrocardiografia Ambulatorial , Projetos Piloto , Processamento de Sinais Assistido por Computador , Dispositivos Eletrônicos Vestíveis
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA