Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Journal of Xi'an Jiaotong University(Medical Sciences) ; (6): 122-126, 2017.
Artigo em Chinês | WPRIM | ID: wpr-509322

RESUMO

ABSTRACT:Objective To investigate the distributional characteristics of anaphylactogens in prurigo nodularis (PN)patients so as to provide clinical basis for selecting the method of allergy test.Methods We divided 262 PN patients into four groups and then used skin-prick (5 4 patients ),skin-patch (5 0 patients ),serum IgE allergen detection (56 patients)and serum IgG allergen detection (102 patients)to analyze anaphylactogen positive rate and their distribution differences in PN.Results For skin-prick test in 54 PN patients,the detection rates of platanus orientalis,artemisia argyi,poplar,dust mite,dirt mite,cod,peanut and tomato were higher than those in the control group (P<0.05 ).For skin-patch test in 50 PN patients,the detection rates of nickel sulfate,flavor compounds,black rubber,and carba mix were higher than those in the control group (P<0.05).For serum IgE test in 5 6 PN patients,the detection rates of house dust,scandent hop,cat/dog hair,bug,penicillium/neurospora and mutton were higher than those in the control group (P<0.05).For serum IgG test in 102 PN ones,the detection rates of crab,shrimp,beef and cod were higher than those in the control group (P<0.05).Conclusion Skin-prick test and serum IgE detection have high application values in PN patients.Serum IgG detection is of certain importance in adjusting PN patients’diet structure while skin-patch test applied in PN needs further exploration.

2.
Japanese Journal of Cardiovascular Surgery ; : 466-470, 2013.
Artigo em Japonês | WPRIM | ID: wpr-375247

RESUMO

A 58-year-old man who complained of dyspnea on effort was given a diagnosis of decompensated congestive heart failure. Echocardiography revealed severe aortic regurgitation and cardiomegaly. We decided to perform aortic valve replacement with a mechanical valve, however his past history made us suspicious of allergy to metal. From his previous patient records, we determined he was allergic to many metals : gold, iron, platinum, cobalt, chrome, bronze, and zinc. Newly performed skin patch tests showed positive reactions to aluminum, tin, palladium, indium, iridium and stainless steel. We selected a CarboMedics mechanical valve made of nickel-titanium alloy. Aortic valve replacement with a 27-mm CarboMedics mechanical valve was performed by median sternotomy. At sternum closure, we used polyester non-absorbable suture thread, instead of surgical steel wire, because it contains stainless steel. His postoperative progress was good and he was discharged on the 10th postoperative day. One year after surgery he is doing well without any allergic symptoms.

3.
Korean Journal of Occupational and Environmental Medicine ; : 276-282, 2009.
Artigo em Coreano | WPRIM | ID: wpr-177608

RESUMO

BACKGROUND: Epoxy resin compounds are one of the common causes of occupational allergic contact dermatitis. In Korea, most cases of allergic contact dermatitis from epoxy resin compounds have been caused by the epoxy resin itself. We report a rare case of allergic contact dermatitis which was caused by epichlorohydrin, an ingredient of epoxy resin and 2,4,6-tris-(dimethylaminomethyl)phenol (tris-DMP), a kind of hardeners. CASE REPORT: A 43-year-old man, who had worked at the epoxy resin glue manufacturing factory since 1999, presented with mild and intermittent erythematous papules and rashes on his face, neck, trunk, and both arms. He was dealing with epoxy resin, epichlorohydrin, bisphenol A and hardeners. After a new hardener was added in August 2008, his skin lesions worsened from what he had experienced in the past. A skin patch test was performed to identify the causative chemicals of the skin lesion. Epichlorohydrin and tris-DMP elicited positive reactions after 48 hours and increased after 96 hours. CONCLUSION: This case confirmed occupational allergic contact dermatitis caused by epichlorohydrin and tris-DMP, an ingredient of epoxy resin and a hardener, respectively.


Assuntos
Adulto , Humanos , Adesivos , Braço , Compostos Benzidrílicos , Dermatite Alérgica de Contato , Epicloroidrina , Exantema , Coreia (Geográfico) , Pescoço , Testes do Emplastro , Fenóis , Pele
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA