Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Adicionar filtros








Intervalo de ano
1.
Chinese Journal of Medical Instrumentation ; (6): 32-37, 2023.
Artigo em Chinês | WPRIM | ID: wpr-971299

RESUMO

Characteristics of two major categories of RA equipment which defined in the standard are interpreted firstly. Few representative RA equipment in current market and their key product features are introduced. Then, classifications of different indexes of spatial positioning accuracy are declared, the difficulties of performing testing process on each indexes are further explained. Meanwhile, different kinds of three dimensional coordinate measuring equipment that are cutting edge at present stage are introduced with their main methods of use explained. According to characteristics of three dimensional coordinate measuring equipment on the market, proper measuring equipment for testing certain index of spatial positioning accuracy and corresponding experiment method are introduced.


Assuntos
Robótica/normas , Procedimentos Cirúrgicos Robóticos/instrumentação
2.
Chinese Journal of Medical Instrumentation ; (6): 26-31, 2023.
Artigo em Chinês | WPRIM | ID: wpr-971298

RESUMO

Due to the need to achieve precise operations during surgery, in order to prevent hand tremors and poor surgical field of view, more and more surgical robots are used in surgical operations combined with navigation technology to meet the requirements for surgical accuracy. Open surgery such as orthopaedics, joint replacement and neurosurgery on the market generally use optical navigation systems to guide robots to achieve precise positioning, but optical navigation systems cannot be used for operations in areas with small surgical space. Therefore, a robotic surgical system based on electromagnetic navigation technology that can be applied to the craniofacial area was proposed. By using this robot, the problems of difficult operation and low precision caused by the narrow craniofacial space can be solved. Key techniques and considerations are studied. The function of the developed prototype is verified through model tests. The test results show that the surgical robot under the electromagnetic navigation technology can achieve precise surgical operations improve the success rate of the doctor's surgery and reduce postoperative complications.


Assuntos
Humanos , Robótica , Procedimentos Cirúrgicos Robóticos , Fenômenos Eletromagnéticos , Complicações Pós-Operatórias
3.
Chinese Journal of Medical Instrumentation ; (6): 19-25, 2023.
Artigo em Chinês | WPRIM | ID: wpr-971297

RESUMO

Transbronchil biopsy has the characteristic of less trauma and quick recovery compared to percutaneous aspiration biopsy. In order to automate this procedure, it requires the development of a robotic surgical system that combines electromagnetic navigation and flexible endoscope. The robotic surgical system introduced herein consists of flexible endoscope, remote-control handle, electromagnetic navigation and dexterous manipulators. The robotic system supports lung bronchial model segmentation and reconstruction, automatic bronchial path planning, real-time navigation and visual biopsy. In the control of the endoscopic catheter, an elasticity compensation algorithm was proposed to improve the location accuracy of the catheter and operational efficiency. Clinical trials proved that the robotic system had high positioning accuracy, was intuitive to operate, and could improve the biopsy efficiency, shorten the learning time, reduce the burden of surgical operations, and lower radiation exposure and infection rate.


Assuntos
Catéteres , Procedimentos Cirúrgicos Robóticos , Endoscopia , Broncoscopia
4.
Chinese Journal of Medical Instrumentation ; (6): 13-18, 2023.
Artigo em Chinês | WPRIM | ID: wpr-971296

RESUMO

As the robotic assisted single port surgery arousing attention, a novel single-arm single-port micro-traumatic laparoscopic robotic surgical system is proposed in this study. From the perspective of the mechanics, joints with high rigidity and high reliability were utilized to realize the remote center of motion (RCM). Besides, the cost of consumables was reduced by adding the support of the rigid endoscope. From the perspective of the algorithm, high-precision motion control method and feedback force protection mechanism were implemented. The effectiveness of the aforementioned characteristics were verified by five clinical experiments of cholecystectomy. The results showed that the system is able to reduce the amount of bleeding, accelerate the patient recovery, reduce the infection risk and shorten the learning period. The robotic surgical system had significant clinical application value.


Assuntos
Humanos , Procedimentos Cirúrgicos Robóticos , Reprodutibilidade dos Testes , Laparoscopia , Movimento (Física)
5.
Chinese Journal of Medical Instrumentation ; (6): 1-12, 2023.
Artigo em Chinês | WPRIM | ID: wpr-971295

RESUMO

OBJECTIVE@#To study the development of surgical robots at home and abroad in recent years.@*METHODS@#Through a large number of literature review and analysis, the qualification approval and technical function characteristics of domestic and foreign surgical robots from January 2019 to July 2022 were analyzed.@*RESULTS@#The related situations of 39 surgical robots were analyzed and reported, and the shortcomings and future development direction of the current surgical robots were summarized.@*CONCLUSIONS@#The development of surgical robots in China is now in a rapid development stage. At present, surgical robots generally have the disadvantages of high cost, lack of tactile feedback (force feedback), large size, large space occupation and difficult to move. In the future, it will develop towards intelligent, miniaturized, remote, open and low-cost.


Assuntos
China , Robótica , Procedimentos Cirúrgicos Robóticos
6.
Chinese Journal of Orthopaedic Trauma ; (12): 194-199, 2022.
Artigo em Chinês | WPRIM | ID: wpr-932312

RESUMO

Objective:To evaluate the emergency iliosacral screw fixation assisted by TiRobot for unstable posterior pelvic ring fracture.Methods:The 26 patients with unstable pelvic fracture were analyzed retrospectively who had undergone emergency iliosacral screw fixation at Department of Orthopedics & Traumatology, Beijing Jishuitan Hospital from June 2018 to December 2020. They were divided into 2 groups depending on whether orthopaedic TiRobot was used to assist screw insertion. In the observation group of 14 cases subjected to TiRobot-assisted insertion of iliosacral screws, there were 10 males and 4 females with an age of (45.9 ± 10.1) years; in the control group of 12 cases subjected to conventional manual insertion of iliosacral screws, there were 9 males and 3 females with an age of (49.2 ± 11.3) years. All the surgeries were conducted within 24 hours after injury. The 2 groups were compared in terms of screw insertion time, pin insertion, intraoperative blood loss, fluoroscopy time, postoperative screw position, fracture reduction and Harris hip score at the final follow-up.Results:The 2 groups were comparable because there was no significant difference between them in their preoperative general clinical data or follow-up time ( P>0.05). The screw insertion time [(16.1 ± 3.4) min] and fluoroscopy time [(8.1 ± 3.3) s] in the observation group were significantly shorter than those in the control group [(26.4 ± 5.4) min and (25.2 ± 7.4) s], and the pin insertions [1 (1, 2) times] and intraoperative blood loss [(10.5 ± 6.4) mL] in the former were significantly less than those in the latter [6 (3, 8) times and (24.8 ± 6.7) mL] (all P<0.05). Postoperatively, the sacroiliac screw position was excellent in 18 cases and good in 2 in the observation group while excellent in 14 cases, good in 2 and poor in 2 in the control group; the fracture reduction was excellent in 12 cases, good in one and fair in one in the observation group while excellent in 10 cases, good in one and fair in one in the control group, showing insignificant differences in the above comparisons ( P>0.05). There was no significant difference either in the Harris hip score at the final follow-up between the 2 groups ( P>0.05). Conclusion:Compared with conventional manual insertion of iliosacral screws, emergency iliosacral screw fixation assisted by TiRobot can effectively decrease surgical time and reduce operative invasion due to a higher accuracy rate of screw insertion.

7.
Frontiers of Medicine ; (4): 382-403, 2020.
Artigo em Inglês | WPRIM | ID: wpr-827849

RESUMO

Minimally invasive surgery, including laparoscopic and thoracoscopic procedures, benefits patients in terms of improved postoperative outcomes and short recovery time. The challenges in hand-eye coordination and manipulation dexterity during the aforementioned procedures have inspired an enormous wave of developments on surgical robotic systems to assist keyhole and endoscopic procedures in the past decades. This paper presents a systematic review of the state-of-the-art systems, picturing a detailed landscape of the system configurations, actuation schemes, and control approaches of the existing surgical robotic systems for keyhole and endoscopic procedures. The development challenges and future perspectives are discussed in depth to point out the need for new enabling technologies and inspire future researches.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA