Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Assunto principal
Intervalo de ano
1.
Indian J Ophthalmol ; 2023 Jul; 71(7): 2704-2710
Artigo | IMSEAR | ID: sea-225134

RESUMO

Purpose: To compare the tear meniscus height (TMH) and tear meniscus depth (TMD) between medically controlled glaucoma subjects and age?matched controls. Methods: This prospective, cross?sectional, observational study included 50 patients with medically controlled glaucoma and 50 age?matched controls. Glaucoma subjects using topical medications for the duration of more than 1 year were included. The age?matched controls were participants with no history of glaucoma, dry eye, or any other diseases affecting the ocular surface. All the participants underwent TMH and TMD scan using spectral domain?optical coherence tomography (SD?OCT), which was followed by ocular surface disease index (OSDI) questionnaire administration. Results: The mean ages of glaucoma subjects and age?matched controls were 40 ± 22 and 39 ± 21 years, respectively (P > 0.05). Of them, 40% (n = 22) were on single drug therapy or monotherapy and 60% (n = 28) were on multidrug therapy. TMH and TMD of glaucoma subjects and age?matched controls were 101.27 ± 31.86 versus 230.63 ± 49.82 ?m and 70.60 ± 27.41 versus 167.37 ± 57.06 ?m, respectively. Subjects on multidrug therapy showed a statistically significant reduction in TMH and TMD when compared to age?matched controls. Conclusion: Preservative containing topical glaucoma medications affects the ocular surface, including the tear film. The prolonged duration and multiple combination of this drug usage serve as potential factors for causing reduction in the tear meniscus levels leading to drug?induced dryness

2.
Journal of the Korean Ophthalmological Society ; : 929-934, 2019.
Artigo em Coreano | WPRIM | ID: wpr-766840

RESUMO

PURPOSE: To evaluate the repeatability and reproducibility of inferior tear meniscus measurements using two different spectral domain-optical coherence tomography (OCT), and to compare the inter-device agreements between these devices. METHODS: Two examiners evaluated the tear meniscus depth (TMD) and tear meniscus height (TMH) of 20 eyes in 20 normal subjects using Cirrus OCT and Spectralis OCT with the examiners calculating the TMD and TMH. We analyzed intra-examiner repeatability, inter-examiner reproducibility, and inter-device agreement. RESULTS: The average TMD measurements using the Cirrus OCT and Spectralis OCT devices were 151.25 ± 41.53 µm and 139.10 ± 40.56 µm by examiner 1, respectively, and 152.03 ± 42.77 µm and 138.35 ± 39.70 µm by examiner 2, respectively. The TMHs were 291.90 ± 100.19 µm and 245.43 ± 66.44 µm by examiner 1, respectively, and 288.25 ± 98.72 µm and 244.23 ± 60.69 µm by examiner 2, respectively. The TMDs and TMHs measured using these OCT devices were not statistically significant for intra-examiner and inter-examiner measurements (all, p > 0.05). These devices showed high repeatability (intraclass correlation coefficient ≥ 0.991) for intra-examiner TMD and TMH measurements and the inter-examiner coefficient of variation ranged from 2.04% to 4.32%. The 95% limits of agreement between the two devices were −66.13 to 91.95 µm for TMD and −127.18 to 217.68 µm for TMH. CONCLUSIONS: Both OCT devices are useful for conducting inferior tear meniscus measurements. The inter-device agreement was poor, and the devices were not interchangeable.


Assuntos
Lágrimas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA