Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J. appl. oral sci ; 26: e20170215, 2018. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-893700

RESUMO

Abstract Objective To evaluate the amount of apically extruded debris, percentage of foraminal enlargement and apical foramen (AF) deformation that occurred during root canal preparation with different reciprocation systems: Reciproc, WaveOne (M-Wire), and ProDesign R (Shape Memory Technology Wire) at two different working lengths (WLs): 0.0 and 1.0 mm beyond the AF. Material and methods The AF of 120 root canals in 60 mesial roots of mandibular molars were photographed with stereomicroscope and randomly assigned into four groups: manual, Reciproc (REC), WaveOne (WO), and ProDesign R (PDR); subsequently, they were further subdivided according to the WL (n=15). Teeth were instrumented, coupled to a dual collecting chamber, and then another photograph of each AF was captured. Extrusion was analysed by determining the weight of extruded debris. Each AF diameter was measured in pre- and post-instrumentation images to determine deformation, which was analysed, and afterwards the final format of AFs was classified (circular/oval/deformed). Results We found no significant differences when analysing each system at different WLs. When considering each WL, REC and WO showed highest extrusion values (P<.05); for AF enlargement, differences were observed only for WO, when it was used beyond the AF; differences were observed among M-Wire groups beyond the AF (P<.05). AF deformation was observed in all groups; PDR showed the lowest AF deformation values at both WLs; M-Wire groups showed 50% strain beyond the AF. Conclusion Authors concluded that beyond the apical limit, the alloy and taper are important aspects when considering extrusion and deformation.


Assuntos
Humanos , Titânio/química , Preparo de Canal Radicular/efeitos adversos , Preparo de Canal Radicular/instrumentação , Ápice Dentário/química , Níquel/química , Valores de Referência , Distribuição Aleatória , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Preparo de Canal Radicular/métodos , Ápice Dentário/anatomia & histologia , Instrumentos Odontológicos/efeitos adversos , Desenho de Equipamento
2.
Belo Horizonte; s.n; 2013. 82 p. ilus, tab.
Tese em Inglês, Português | LILACS, BBO | ID: lil-698319

RESUMO

O objetivo deste trabalho foi comparar as propriedades químicas, físicas e mecânicas de fios de níquel-titânio convencionais (CW) e termomecanicamente tratados (MW), utilizados na fabricação de instrumentos endodônticos por dois fornecedores diferentes (Dentsply Tulsa Dental Specialities, Tulsa - OK, USA e dentsply maillefer - Ballaigues, Switzerland). Foram ainda avaliados o torque e a força apical requerida pelos novos instrumentos endodônticos ProTaper NextÕ. A composição química foi determinada por espectroscopia de energia dispersiva de raios-X, a constituição de fase por difratometria de raio-X e as temperaturas de transformação por calorimetria exploratória diferencial. Ensaios de tração em carga e descarga e até ruptura, flexão em três pontos, flexão rotativa/fadiga e medidas de microdureza Vickers foram realizados para avaliar o comportamento mecânico dos fios. As superfícies de fratura foram observadas por microscopia eletrônica de varredura e as microestruturas não deformadas por microscopia eletrônica de transmissão...


Assuntos
Instrumentos Odontológicos , Preparo de Canal Radicular/instrumentação , Torque , Tratamento do Canal Radicular/instrumentação , Análise Espectral , Ápice Dentário/química , Microscopia Eletrônica de Varredura , Níquel/uso terapêutico , Fenômenos Químicos , Titânio/uso terapêutico
3.
J. appl. oral sci ; 20(3): 329-334, May-June 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-643729

RESUMO

OBJECTIVE: The aim of this study was to compare the correspondence between gap formation and apical microleakage in root canals filled with epoxy resin-based (AH Plus) combined or not with resinous primer or with a dimethacrylate-based root canal sealer (Epiphany). MATERIAL AND METHODS: Thirty-nine lower single-rooted human premolars were filled by the lateral condensation technique (LC) and immersed in a 50-wt% aqueous silver nitrate solution at 37ºC (24 h). After longitudinal sectioning, epoxy resin replicas were made from the tooth specimens. Both the replicas and the specimens were prepared for scanning electron microscopy (SEM). The gaps were observed in the replicas. Apical microleakage was detected in the specimens by SEM/energy dispersive spectroscopy (SEM/EDS). The data were analyzed statistically using an Ordinal Logistic Regression model and Analysis of Correspondence (α=0.05). RESULTS: Epiphany presented more regions containing gaps between dentin and sealer (p<0.05). There was correspondence between the presence of gaps and microleakage (p<0.05). Microleakage was similar among the root-filling materials (p>0.05). CONCLUSIONS: The resinous primer did not improve the sealing ability of AH Plus sealer and the presence of gaps had an effect on apical microleakage for all materials.


Assuntos
Humanos , Infiltração Dentária/etiologia , Resinas Epóxi/química , Materiais Restauradores do Canal Radicular/química , Obturação do Canal Radicular/métodos , Ápice Dentário/química , Modelos Logísticos , Teste de Materiais , Microscopia Eletrônica de Varredura , Distribuição Aleatória , Espectrometria por Raios X
4.
J. appl. oral sci ; 20(3): 347-351, May-June 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-643732

RESUMO

OBJECTIVES: The aim of this study was to evaluate the apical sealability of Fillapex®, endo-CPM-Sealer® and Sealapex®. Material and Methods: Ninety-four freshly extracted single-rooted teeth were selected and decoronated. All teeth were radiographed to confirm the existence of a single and straight root canal, which was prepared using Protaper Universal and 2.5% sodium hypochlorite. The teeth were randomly divided in groups of 10 specimens each according to the sealer, and the canals were filled using the single cone technique and one of the sealers. Four additional teeth were used as controls. The teeth were submitted to dye leakage with Rhodamine B for 24 h but using vacuum on the initial 15 min. Thereafter, they were cut longitudinally and the leakage was measured in a linear fashion from apex to crown. Data were analyzed by ANOVA and Tukey's tests at 5% significance level. Results: Fillapex® and Sealapex® showed significantly less dye leakage than endo-CPM-Sealer® (p<0.05). Conclusions: It was concluded that Fillapex® and Sealapex® were able to prevent apical dye leakage differently from endo-CPM-Sealer®.


Assuntos
Humanos , Compostos de Alumínio/química , Compostos de Cálcio/química , Hidróxido de Cálcio/química , Infiltração Dentária/prevenção & controle , Óxidos/química , Materiais Restauradores do Canal Radicular/química , Silicatos/química , Análise de Variância , Combinação de Medicamentos , Teste de Materiais , Obturação do Canal Radicular/métodos , Salicilatos/química , Fatores de Tempo , Ápice Dentário/química , Ápice Dentário/efeitos dos fármacos
5.
Braz. dent. j ; 21(1): 32-37, Jan. 2010. ilus, tab
Artigo em Inglês | LILACS | ID: lil-552352

RESUMO

Considering that blood fluoride concentration varies according to fluoride exposure and that dental fluorosis is related to the amount of enamel formed under a given fluoride dose, the present study investigated whether the fluorosis produced by an oscillating chronic fluoride dose would be similar to that caused by exposure to a constant dose, representing the mean of the oscillation during a given time. Rats received during 78 days water with fluoride concentrations of 0, 12.5, 25 or 37.5 µg F/mL, or oscillating concentrations of 12.5 and 37.5 µg F/mL every 72 h (mean exposure=25 µg F/mL). The concentrations of fluoride in the plasma, femur and incisors of the rats were determined at the end of the experimental period. Also, the enamel dental fluorosis index was determined in the incisors using a quantitative method developed by our research group named Dental Fluorosis by Image Analysis (DFIA). Fluoride concentrations in plasma, femur and teeth, and DFIA increased linearly for constant fluoride concentrations in water (p<0.0001, r values=0.87-0.98). The results of the oscillating group and the groups receiving 25 µg F/mL did not differ significantly (p>0.05). The findings of this study suggest that in animals chronically exposed to symmetrically oscillating fluoride doses, the resulting dental fluorosis reflects the metabolic effect of the mean of the oscillating doses.


Considerando que a concentração de fluoreto no sangue varia de acordo com a exposição ao fluoreto, e que a fluorose dental está relacionada com a quantidade de esmalte formado sob determinada dose de fluoreto, este estudo avaliou se a fluorose resultante da exposição a doses oscilantes de fluoreto seria semelhante àquela causada pela exposição a uma dose constante, representativa da média das oscilações durante um determinado tempo. Durante 78 dias, ratos receberam água com concentrações constantes de fluoreto de 0; 12,5; 25 ou 37,5 µg F/mL, ou concentrações oscilantes de 12,5 e 37,5 µg F/mL alternados a cada 72 h (média de exposição = 25 µg F/mL). Concentrações de fluoreto no plasma, fêmur e dentes incisivos dos ratos foram determinadas após o período experimental. O índice de fluorose, observado nos incisivos dos ratos, foi quantificado usando um método de análise de imagem desenvolvido para essa pesquisa, denominado de índice de fluorose por análise de imagem (DFIA, em Inglês). A concentração de fluoreto no plasma, fêmur e incisivo dos ratos, assim como o DFIA, aumentaram de forma linear para as concentrações constantes de fluoreto na água (p<0,0001, r=0,87-0,98). Não houve diferença significativa entre o grupo que recebeu doses oscilantes e o grupo que recebeu 25 µg F/mL (p>0,05). Os resultados sugerem a fluorose dental decorrente de exposição crônica de animais a doses de fluoreto oscilantes e simétricas reflete o efeito metabólico da média da oscilação.


Assuntos
Animais , Feminino , Ratos , Cariostáticos/farmacocinética , Fluoretos/farmacocinética , Fluorose Dentária/classificação , Processo Alveolar/química , Cariostáticos/administração & dosagem , Cariostáticos/análise , Relação Dose-Resposta a Droga , Esmalte Dentário/química , Fêmur/química , Fluoretos/administração & dosagem , Fluoretos/sangue , Processamento de Imagem Assistida por Computador/métodos , Incisivo/química , Mandíbula/química , Fotografia Dentária/métodos , Distribuição Aleatória , Ratos Wistar , Método Simples-Cego , Ápice Dentário/química , Abastecimento de Água/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA