Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
ABCD (São Paulo, Impr.) ; 30(2): 77-82, Apr.-June 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-885705

RESUMO

ABSTRACT Background: Hernia correction is a routinely performed treatment in surgical practice. The improvement of the operative technique and available materials certainly has been a great benefit to the quality of surgical results. The insertion of prostheses for hernia correction is well-founded in the literature, and has become the standard of treatment when this type of disease is discussed. Aim: To evaluate two available prostheses: the polypropylene and polypropylene coated ones in an experimental model. Methods: Seven prostheses of each kind were inserted into Wistar rats (Ratus norvegicus albinus) in the anterior abdominal wall of the animal in direct contact with the viscera. After 90 days follow-up were analyzed the intra-abdominal adhesions, and also performed immunohistochemical evaluation and videomorphometry of the total, type I and type III collagen. Histological analysis was also performed with hematoxylin-eosin to evaluate cell types present in each mesh. Results: At 90 days the adhesions were not different among the groups (p=0.335). Total collagen likewise was not statistically different (p=0.810). Statistically there was more type III collagen in the coated polypropylene group (p=0.039) while type I was not different among the prostheses (p=0.050). The lymphocytes were statistically more present in the polypropylene group (p=0.041). Conclusion: The coated prosthesis was not different from the polypropylene one regarding the adhesion. Total and type I collagen were not different among the groups, while type III collagen was more present on the coated mesh. There was a greater number of lymphocytes on the polypropylene mesh.


RESUMO Racional: A correção herniária é tratamento realizado rotineiramente na prática cirúrgica. O aprimoramento da técnica operatória e dos materiais disponíveis trouxe grande benefício na qualidade dos resultados cirúrgicos. A inserção de próteses para correção herniária é bem embasada na literatura e tornou-se o padrão de tratamento. Objetivo: Avaliar em modelo experimental dois tipos de próteses diferentes, de polipropileno e polipropileno revestido. Métodos: Foram inseridas sete próteses de cada tipo em ratos Wistar (Ratus norvegicus albinus) na parede abdominal anterior do animal em contato direto com as vísceras. Após o seguimento de 90 dias analisaram-se as aderências intra-abdominais, bem como avaliação por imunoistoquímica e videomorfometria do colágeno total, tipo I e tipo III. Também, fez-se análise histológica com hematoxylina-eosina para avaliação dos tipos celulares presentes em cada tela. Resultados: Aos 90 dias as aderências não foram diferentes entre os grupos (p=0,335). O colágeno total igualmente não foi estatisticamente diferente (p=0,810). O colágeno tipo III foi estatisticamente maior no grupo polipropileno revestido (p=0,039) enquanto o tipo I não diferiu entre as próteses (p=0,050). Os linfócitos foram estatisticamente mais presentes no grupo polipropileno (p=0,041). Conclusão: A prótese revestida não foi diferente da de polipropileno na variável aderência. O colágeno total e tipo I não foram diferentes entre os grupos enquanto que o colágeno tipo III foi mais presente na tela revestida. O número de linfócitos foi maior na tela de polipropileno.


Assuntos
Animais , Masculino , Ratos , Doenças Peritoneais/classificação , Polipropilenos/química , Complicações Pós-Operatórias/classificação , Telas Cirúrgicas/efeitos adversos , Colágeno/análise , Doenças Peritoneais/etiologia , Complicações Pós-Operatórias/etiologia , Aderências Teciduais/classificação , Aderências Teciduais/etiologia , Ratos Wistar , Materiais Revestidos Biocompatíveis , Desenho de Equipamento , Herniorrafia/instrumentação
2.
Veterinary Medical Journal. 2006; 54 (3): 495-517
em Inglês | IMEMR | ID: emr-81547

RESUMO

This study was carried out on twenty two donkeys subjected to jejunal and cecal serosal stripping adhesion induction model followed by intra- and post-operative peritoneal lavage for the first three postinduction days. The chosen antiadhesivc pharmaceuticals are dimethyl sulfoxide 20% solution; sodium chloride sterile solution containing 5000 IU heparin/liter; Ringer's lactate sterile solution containing 0.1% lavasept and 1% sodium carboxymethycellulose. From the quantitative macroscopic and histopathological adhesions score system and the clinicopathological findings insignificant differences was found in the postsurgical adhesions scores among peritoneal lavaged and control groups. The effectiveness of intraperitoneal lavage using dimethyl sulfoxidc, heparin, lavasept and sodium carboxymethylcellulose in the prevention of adhesions cannot be scientifically supported because the results were controversial and lacked any implication for clinical use. No method has gained wide acceptance and surgeons must rely on meticulous surgical technique which can minimize tissue trauma and reducing the risk of postsurgical adhesions formation


Assuntos
Animais , Complicações Pós-Operatórias , Aderências Teciduais/terapia , Equidae , Dimetil Sulfóxido , Abdome/cirurgia , Aderências Teciduais/classificação , Doenças Peritoneais/terapia , Cuidados Pós-Operatórios , Cuidados Intraoperatórios
3.
J. bras. med ; 78(3): 66-72, mar. 2000. ilus, tab
Artigo em Português | LILACS | ID: lil-289084

RESUMO

Os autores fazem uma revisão e atualização sobre as sinéquias intra-uterinas (SIUs), enfocando principalmente sua importância atual e o método histeroscópico para o tratamento dessa afecção. Outros enfoques terapêuticos como a histerotomia no tratamento das SIUs totais, limitações do método histeroscópico e eventuais complicações obstétricas subseqüentes à sinequiolise histeroscópica são também discutidos neste trabalho


Assuntos
Humanos , Feminino , Dilatação e Curetagem/efeitos adversos , Doenças Uterinas/fisiopatologia , Procedimentos Cirúrgicos em Ginecologia/efeitos adversos , Histeroscopia , Histeroscopia/estatística & dados numéricos , Aderências Teciduais/classificação , Aderências Teciduais/etiologia , Aderências Teciduais/terapia , Doenças dos Genitais Femininos
4.
Rev. cuba. obstet. ginecol ; 19(2): 103-8, jul.-dic. 1993. ilus
Artigo em Espanhol | LILACS | ID: lil-141859

RESUMO

Se presenta una clasificación laparoscópica de las adherencias anexiales no endometriósicas, empleada en nuestro servicio y que consideramos de gran valor, pues se basa más en el análisis de la afección fisiológica posible, por parte del endoscopista, que en la lesión anatómica pura (tamaño y caracteres o localización de las adherencias). Se revisan las causas y los mecanismos de producción de estas adherencias y se insiste en su profilaxis


Assuntos
Humanos , Feminino , Doenças dos Anexos , Laparoscopia , Aderências Teciduais/classificação , Aderências Teciduais/etiologia
5.
Ginecol. obstet. Méx ; 58: 22-8, feb. 1990. tab
Artigo em Espanhol | LILACS | ID: lil-95550

RESUMO

Se revisaron 200 pacientes estériles con factor tuboperitoneal alterado. La enfermedad adhesiva anexial fue el factor más importante en la esterilidad. La mayor parte de los casos estaban en la tercera década de vida; 40.5% fue de enfermedad inflamatoria pélvica inespecífica que respondió bien al tratamiento con antibióticos y antiinflamatorios. A mayor grado e enfermedad anexial adhesiva, menor posibilidad de embarazo


Assuntos
Humanos , Feminino , Endometriose/classificação , Infertilidade Feminina/etiologia , Laparoscopia , Peritônio , Aderências Teciduais/classificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA