Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Respirar (Ciudad Autón. B. Aires) ; 16(3): 255-261, Septiembre 2024.
Artigo em Espanhol | LILACS, UNISALUD, BINACIS | ID: biblio-1570577

RESUMO

Introducción: La anemia es frecuentemente subdiagnosticada dada su vaga sintomatología. Estudios con evaluación subjetiva-visual por expertos describen signos tomográficos sugerentes de anemia, tales como el septo denso. Proponemos que lectores con entrenamiento básico realicen mediciones objetivas de alto poder estadístico para la detección de anemia. Material y Métodos: Se cruzaron datos de tomografía computarizada (TC) de tórax no contrastada (2021) con medición de hemoglobina plasmática (Hb) realizada 24 horas antes o después del estudio tomográfico. Dos estudiantes de Medicina, previamente entrenados, realizaron mediciones de Unidades Hounsfield (UH) en el septo interventri-cular (SIV) y cavidades ventriculares derecho (VD) e izquierdo (VI). Las relaciones SIV/VI y SIV/VD se correlacionaron con los valores de Hb. Se analizó la variabilidad interob-servador y se determinó el punto de corte óptimo para detectar anemia. Resultados: En una muestra de 112 casos, hubo alta concordancia interobservador con r de 0,85 (VD), 0,67 (SIV) y 0,87 (VI). La relación SIV/VI obtuvo el mayor AUC con 0,86 (IC 95%: 0,72 a 0,91), con una sensibilidad de 80% y especificidad de 88% utilizando un punto de corte de 1,15. Conclusiones: La razón SIV/VI con punto de corte de 1,15 es un parámetro confiable para detectar anemia mediante TC de tórax no contrastada, en observadores con entrenamiento básico.


Introduction: Anemia is frequently underdiagnosed given its vague symptomatology. Studies with subjective-visual evaluation by experts describe tomographic signs suggestive of anemia, such as a dense septum. This study aims to evaluate if readers with basic training can perform high statistical value measurements for anemia detection. Material and Methods: Data of non-contrast thoracic computed tomography (CT) (2021) with a measurement of plasma hemoglobin (Hb) performed 24 hours before or after the CT were identified. Two previously trained medical students performed measurements of Hounsfield Units (HU) on the interventricular septum (IVS) and right (RV) and left (LV) ventricular cavities. The SIV/VI and SIV/VD ratios were correlated with Hb values. Interobserver variability was analyzed and the optimal cut-off point to detect anemia was determined. Results: In a sample of 112 cases, there was a high interobserver correlation with r of 0.85 (VD), 0.67 (SIV), and 0.87 (VI). SIV/VI ratio obtained the highest AUC with 0.86 (95% CI: 0.72 to 0.91), with a sensitivity of 80% and specificity of 88% using a cut-off point of 1.15. Conclusions: The SIV/VI ratio with a cut-off point of 1.15 is a reliable parameter to detect anemia using non-contrast chest CT in observers with basic training.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Tomografia , Anemia/diagnóstico por imagem , Estudantes de Medicina , Tórax/diagnóstico por imagem , Hemoglobinas , Chile , Septo Interventricular/diagnóstico por imagem , Ventrículos do Coração
2.
New Egyptian Journal of Medicine [The]. 1995; 12 (Supp. 2): 233-237
em Inglês | IMEMR | ID: emr-38939
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA