Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Acta sci., Biol. sci ; 43: e53105, 2021. tab, graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1460969

RESUMO

The use of genotypes more adapted to climatic conditions can contribute to increase the yield of onion producers. The goal of this study was to evaluate the agronomic performance of 15 onion genotypes in the soil and climatic conditions of Guarapuava, state of Paraná. The study was conducted in the experimental area of Horticulture, Cedeteg campus, Universidade Estadual do Centro-Oeste (UNICENTRO), Guarapuava, state of Paraná, Brazil, from July to November 2018. The experimental design used was randomized blocks, with four replications, and the treatments consisted of four commercial cultivars Optima F1, Bella Dura, Sirius F1, Soberana F1 and eleven experimental genotypes N1, N2, N3, N4, N5, N6, N7, N8, N9, AF4241 and AF4243. Biometric characteristics of the plants, production components and early flowering were evaluated. Plants presented between 6 and 9 leaves, in which N1, N3, N4 and N6 had less than 7 leaves, differing statistically from the others. The cultivar Optima F1 and the genotypes N2, N3, N5, N6, N7 and N8 presented the tallest plants, with 66.1 to 76.0 cm. The pseudostem diameter did not differ significantly between genotypes, showing values between 15.2 and 20.4 mm. Total productivity was higher in genotypes N2, N6, N5, N4, N3, N7 with values from 43.6 to 50.3 t ha-1. The highest average bulb mass was found in N2, N4, N6, Sirius F1, Optima F1 and Soberana F1


Assuntos
Biometria/instrumentação , Cebolas/enzimologia , Cebolas/genética
2.
Rev. bras. oftalmol ; 77(5): 272-277, set.-out. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-977871

RESUMO

Abstract Purpose: To report the prevalence and analyse corneal astigmatism patterns in cataract surgery candidates. Methods: Researchers examined 2136 eyes from 1204 patients for cataract surgery from 1 January to 31 December 2016. All the candidates were evaluated with partial coherence interferometry (IOLMaster). The results were analysed statistically in relation to qualitative and quantitative variables. Results: The mean age of the patients was 71.9 years with a female predominance. Mean corneal astigmatism was 1.0 dioptre (D). Against the rule (ATR) astigmatism increased with age. Women presented with steeper corneas than men. In those patients who had both eyes measured, we found strong correlations between amount of right and left eye astigmatism, axis and keratometry. Overall, 39% of the eyes had corneal astigmatism > 1.00 D and 19% >1.50 D. Conclusions: A significant percentage of our population presents with corneal astigmatism > 1.00 D with a shift from WTR (with the rule) to ATR with increasing age. Our findings, in a population that has never been described before, will be helpful to surgeons to enhance surgical techniques, patients to improve visual outcomes, IOL (intraocular lens) manufacturers to make better designs and health agents to optimise resources.


Resumo Objetivo: Relatar a prevalência e analisar os padrões de astigmatismo corneano em candidatos à cirurgia de catarata. Métodos: Os pesquisadores examinaram 2136 olhos de 1204 pacientes a cirurgia de catarata de 1 de janeiro a 31 de dezembro de 2016. Todos os candidatos foram avaliados com interferometria de coerência parcial (IOLMaster). Os resultados foram analisados estatisticamente em relação às variáveis qualitativa e quantitativa. Resultados: A média de idade dos pacientes foi de 71,9 anos, com predomínio do sexo feminino. A média de astigmatismo corneano foi de 1,0 dioptria (D). Contra a regra (ATR), o astigmatismo aumentou com a idade. As mulheres apresentaram córneas mais íngremes que os homens. Nos pacientes que tiveram os dois olhos medidos, encontramos fortes correlações entre quantidade de astigmatismo nos olhos direito e esquerdo, eixo e ceratometria. No geral, 39% dos olhos tinham astigmatismo corneano >1,00 D, e 19% > 1,50 D. Conclusões: Uma percentagem significativa da nossa população apresenta astigmatismo corneano >1,00, D com uma mudança de WTR (a favor da regra) para ATR (contra a regra) com o aumento da idade. Nossas descobertas em uma população que nunca foi descrita antes serão úteis para os cirurgiões melhorarem suas técnicas cirúrgicas, os pacientes melhorarem seus resultados visuais, os fabricantes de LIOs (lentes intraoculares) criarem projetos melhores, e os agentes de saúde otimizarem os recursos.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Astigmatismo/epidemiologia , Facoemulsificação/estatística & dados numéricos , Córnea/diagnóstico por imagem , Interferometria , Astigmatismo/fisiopatologia , Extração de Catarata/estatística & dados numéricos , Prevalência , Biometria/instrumentação , Comprimento Axial do Olho , Imagem Óptica/instrumentação , Câmara Anterior
3.
Rev. bras. oftalmol ; 77(5): 268-271, set.-out. 2018. graf
Artigo em Português | LILACS | ID: biblio-977865

RESUMO

Resumo Objetivos: Medir o ângulo lâmbda (AL) em indivíduos no pré-operatório de facectomias, correlacionando a sua presença com o comprimento axial e o esférico dos olhos. Sugerir condutas para o implante de LIO multifocal de acordo com a presença do ângulo lâmbda. Métodos: Estudo transversal em 128 olhos de 74 indivíduos candidatos à cirurgia de catarata para registrar a equivalente presença do ângulo lâmbda. Resultados: Avaliando o ângulo lâmbda observou-se uma correlação positiva (r= 0,559 / p= 0,000) para o tamanho desse ângulo comparando-se os dois olhos. Não houve correlação entre o tamanho do ângulo lâmbda e o equivalente esférico no olho direito (r= -0,027 / p= 0,840), mas foi verificada correlação positiva para o olho esquerdo (r= 0,313 / p= 0,013). A presença da hipermetropia correlacionou com os comprimentos axiais pequenos, assim como a miopia com os grandes. Observou-se correlação negativa entre o tamanho do ângulo lâmbda e o comprimento axial para os dois olhos, sendo de r= -0,249 para o olho direito (p= 0,042) e r= -0,281 para o olho esquerdo (p= 0,018) Conclusões: Houve correlação entre a presença de ângulo lâmbda maior e comprimentos axiais menores para os dois olhos. Para o equivalente esférico hipermétrope houve correlação com a presença de um ângulo lâmbda maior apenas para o olho esquerdo. Esse trabalho sugere parcimônia nos implantes de LIO multifocal na presença de ângulo lâmbda significativo, baseado na teoria que a presença desse ângulo é reguladora do equilíbrio entre as aberrações da superfície corneana versus cristalineanas.


Abstract Objectives: To measure the labral angle (LA) in individuals in the preoperative period of facectomies, correlating their presence with axial length and spherical equivalent of the eyes. Suggest conduits for the implantation of multifocal IOL according to the presence of the lambda angle. Methods: A cross-sectional study of 128 eyes of 74 individuals who were candidates for cataract surgery to record the presence of the lambda angle. Results: A positive correlation (r = 0.559 / p = 0.000) was observed for the angle of this angle by comparing the two eyes. There was no correlation between the size of the lambda angle and the spherical equivalent in the right eye (r = -0.027 / p = 0.840), but a positive correlation was observed for the left eye (r = 0.313 / p = 0.013). The presence of hyperopia correlated with small axial lengths, as did myopia with large ones. There was a negative correlation between the angle of the tongue and the axial length of the two eyes, with r = -0.249 for the right eye (p = 0.042) and = 0.281 for the left eye (p = 0.018). Conclusions: There was a correlation between the presence of a larger lambda angle and smaller axial lengths for both eyes. For the spherical hypermétrope equivalent, there was a correlation with the presence of a larger blunt angle only for the left eye. This work suggests parsimony in multifocal IOL implants in the presence of a significant lamella angle, based on the theory that the presence of this angle regulates the balance between corneal versus crystaline surface aberrations.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Pupila/fisiologia , Topografia da Córnea/métodos , Implante de Lente Intraocular , Comprimento Axial do Olho , Lentes Intraoculares Multifocais , Iluminação , Extração de Catarata/estatística & dados numéricos , Estudos Transversais , Biometria/instrumentação , Biometria/métodos , Período Pré-Operatório , Fixação Ocular , Fenômenos Fisiológicos Oculares
4.
Rev. bras. oftalmol ; 77(4): 184-188, jul.-ago. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-959100

RESUMO

ABSTRACT Objective: To evaluate the correlation of optical biometry and target with variable ages, anterior chamber depth, axial length, R1/K1 and R2/K2 established by two optical biometry devices in patients with cataract. Methods: The study included the analysis of 348 medical records, from which 503 cataract eyes were selected, which underwent evaluation by the optical biometric devices IOL Master 700 and Lenstar LS 900 in the period of April to July 2017. Data collected were: age, anterior chamber depth, axial length, R1/K1 and R2/K2. Results: The average of the biometrics obtained using Lenstar was 21.02, varying 3.46, more or less, with an average target of -0.02, varying 0.45. In relation to the IOL Master it was 21.19, with a variation of 3.40 and average target of -0.01, a variation of 0.11. It can be observed that despite close values in relation to the mean, there was significance (p<0.001). Axial length (p<0.001) and R1/K1 (p<0.001) had an influence on the difference of the biometric values between the devices. Conclusion: A high degree of clinical and statistical correspondence was observed between the results obtained by the biometry devices in patients with cataract.


RESUMO Objetivos: Avaliar a correlação da biometria óptica e target com as variáveis idade, profundidade da câmara anterior, comprimento axial, R1/K1 e R2/K2 estabelecidos por dois dispositivos de biometria óptica em pacientes com catarata. Métodos: O trabalho abrangeu a análise de 348 prontuários dos quais foram selecionados 503 olhos com catarata ,que passaram pela avaliação nos dispositivos de biometria óptica IOL Master 700 e Lenstar LS 900 no período de abril a julho de 2017. Os dados colhidos foram: idade, profundidade da câmara anterior, comprimento axial, R1/K1 e R2/K2 . Resultados: A média da biometria obtida utilizando o Lenstar foi de 21,02, variando 3,46 para mais ou para menos, com target médio de -0,02, variando 0,45. Já em relação ao IOL Master foi de 21,19, com variação de 3,40 e target médio de -0,01, variação de 0,11. Pode-se observar que apesar de valores próximos em relação à média, houve significância (p < 0,001). Houve a concordância da biometria em relação ao comprimento axial (p < 0,001) e R1/K1(p < 0,001). Conclusão: Observou-se alto grau de correspondência clínica e estatística entre os resultados obtidos pelos dispositivos de biometria em pacientes com catarata.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Erros de Refração/diagnóstico por imagem , Catarata/diagnóstico , Biometria/instrumentação , Biometria/métodos , Comprimento Axial do Olho/diagnóstico por imagem , Lentes Intraoculares/normas , Câmara Anterior/diagnóstico por imagem , Refração Ocular/fisiologia , Extração de Catarata/métodos , Acuidade Visual , Estudos Transversais , Reprodutibilidade dos Testes , Córnea/diagnóstico por imagem , Topografia da Córnea/instrumentação , Implante de Lente Intraocular/métodos , Período Pré-Operatório , Registros Eletrônicos de Saúde , Estudo Observacional , Cristalino/diagnóstico por imagem
5.
Rev. cuba. oftalmol ; 29(4): 712-720, oct.-dic. 2016. ilus
Artigo em Espanhol | LILACS | ID: biblio-845055

RESUMO

La emergencia de las lentes intraoculares fáquicas en las pasadas décadas mostró una nueva alternativa para las ametropías extremas. Desde el año 1950 han sido diseñados diferentes modelos de lentes intraoculares fáquicas con distintos diseños y complicaciones. Se presenta un caso con antecedente de miopía elevada, quien posterior a la colocación de una lente intraocular fáquica de cámara anterior de fijación angular presentó como complicación en el posoperatorio abundante pigmentación iridiana sobre el lente y sinequias anteriores en 360 grados. Nos motivamos a publicar este caso y de esta forma proporcionar una actualización sobre las complicaciones de la colocación de estos lentes, así como ofrecer algunas recomendaciones para detectar a tiempo los posibles riesgos de este procedimiento(AU)


The emergence of the phakic intraocular lenses in the last decades showed a new alternative for the extreme ametropias. Since1950 different models of phakic intraoduclar lenses have been designed with different designs and complications. Here is a patient with a history of high myopia who, after having undergone the implantation of an anterior chamber phakic intraocular lens with angle fixation, presented with abundant iridian pigmentation over the lens and anterior sinechia at 360 degrees. The objectives of this report were to provide an update on the complications of the implantation of these lenses as well as making some recommendations to timely detect the possible risks of this procedure(AU)


Assuntos
Humanos , Feminino , Adulto , Câmara Anterior/lesões , Biometria/instrumentação , Lentes Intraoculares/efeitos adversos , Miopia/diagnóstico , Erros de Refração/complicações , Complicações Pós-Operatórias
6.
Rev. bras. oftalmol ; 75(2): 160-165, Mar.-Apr. 2016. tab, graf
Artigo em Português | LILACS | ID: lil-779966

RESUMO

RESUMO Este artigo apresenta uma revisão dos princípios e das aplicações clínicas do princípio de Scheimpflug na área da imagiologia do segmento anterior. Ao disponibilizar uma imagem tridimensional do segmento anterior, esta tecnologia permite a caraterização da elevação e curvatura das superfícies anterior e posterior da córnea, o mapeamento paquimétrico, o cálculo do poder refrativo total da córnea e a biometria do segmento anterior. Na subespecialidade de cirurgia refrativa, esta abordagem melhora a capacidade de identificação de casos com risco de desenvolver ectasia, bem como de planeamento e de avaliação dos resultados dos procedimentos cirúrgicos. Recentemente, esta tecnologia foi introduzida na avaliação biomecânica in vivo da córnea e na cirurgia de catarata assistida por laser de femtossegundo.


ABSTRACT This article presents a review of the principles and clinical applications of the Scheimpflug principle in the anterior segment imaging. By providing a three-dimensional image of the anterior segment, this technology provides elevation and curvature data of the anterior and posterior surfaces of the cornea, pachymetric mapping, the total refractive power of the cornea and the anterior segment biometry. For the refractive surgery sub-specialty, this approach improves the ability to identify cases at risk of ectasia, as well as the planning and evaluation of the results of surgical procedures. Recently, this technology was introduced in corneal biomechanical in vivo evaluations and in femtosecond laser-assisted cataract surgery.


Assuntos
Humanos , Oftalmologia/instrumentação , Fenômenos Biomecânicos , Fotografação/métodos , Córnea/anatomia & histologia , Segmento Anterior do Olho/anatomia & histologia , Tonometria Ocular , Algoritmos , Processamento de Imagem Assistida por Computador , Apresentação de Dados , Fotografação/instrumentação , Fotografação/normas , Tomografia/métodos , Curva ROC , Biometria/instrumentação , Córnea/patologia , Córnea/diagnóstico por imagem , Topografia da Córnea/métodos , Imageamento Tridimensional , Técnicas de Diagnóstico Oftalmológico , Segmento Anterior do Olho/patologia , Segmento Anterior do Olho/diagnóstico por imagem
7.
Rev. bras. oftalmol ; 74(6): 350-354, nov.-dez. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-767072

RESUMO

RESUMO Objetivo: Avaliar os parâmetros biométricos oculares por meio da biometria óptica e observar uma possível diferença refratométrica esférica, assim como sua variação, baseada no cálculo pré-cirúrgico estimado e na refração esférica pós-cirurgia de catarata pela facoemulsificação com implante de lente intraocular (LIO). Métodos: Foram revisados 252 prontuários eletrônicos entre 2013 e 2014 dos quais foram selecionados 117 pacientes adultos (189 olhos) submetidos à facoemulsificação com implante de LIO dobrável pelo mesmo cirurgião e examinados através do IOLMaster® 500. O poder dióptrico da LIO foi calculado pela fórmula de Haigis. O teste de Wilcoxon foi empregado para testar a existência de diferença significativa (p<0,05) entre o grau esférico esperado (GEE) e o grau esférico final (GEF). Resultados: Foram operados 98 olhos direitos (OD) e 91 esquerdos (OE). Após calculada a variação entre o GEE e o GEF observou-se que 55% dos OD alcançaram resultados dentro de ± 0,5 dioptrias (D) e 89% resultados dentro de ± 1D. Quanto ao OE, 46% alcançaram resultados dentro de ± 0,5D e 78% dentro de ± 1D. Conclusão: A biometria óptica pode ser utilizada como um método confiável, previsível e reprodutível para que seja estimado o GEF de ambos olhos.


ABSTRACT Objective: To assess ocular biometric parameters by optical biometry and to observe a possible spherical refractive difference, as well as its variation based on estimated preoperative calculation and the spherical refraction post cataract surgery by phacoemulsification with intraocular lens implant (IOL). Methods: After reviewing 252 electronic medical records between 2013 and 2014, 117 adult patients (189 eyes) were selected.The patients underwent phacoemulsification with foldable IOL implantation by the same surgeon and were examined by IOLMaster® 500.The IOL power was calculated using the Haigis formula.The Wilcoxon test was applied to identify the existence of significant differences (p<0.05) between the spherical expected refraction (SER) and the final spherical refraction (FSR) of the eyes. Results: There were operated 98 right eyes (OD) and 91 left (OS). A calculation of the variation between FSR and SER indicated that 55% of the OD reached results within ± 0.5 diopters (D) and 89% within ± 1D. With respect to OS, 46% achieved results within ± 0.5D and 78% within ± 1D. Conclusion: Optical biometry is a reliable, predictable and reproducible method to estimate the FSR of both eyes.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Biometria/instrumentação , Biometria/métodos , Facoemulsificação/métodos , Implante de Lente Intraocular/métodos , Comprimento Axial do Olho/anatomia & histologia , Refração Ocular/fisiologia , Extração de Catarata/métodos , Estudos Transversais , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Registros Eletrônicos de Saúde , Lentes Intraoculares
8.
Arq. bras. oftalmol ; 77(6): 345-350, Nov-Dec/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-735807

RESUMO

Purpose: To compare the results of central corneal thickness (CCT) measurements obtained using optical low-coherence reflectometry (OLCR), Fourier domain optical coherence tomography (FD-OCT), and a Scheimpflug camera (SC), combined with Placido corneal topography. Methods: A total of 25 healthy subjects were enrolled in the present study, and one eye of each subject was included. A detailed ophthalmic examination was performed in all cases following CCT measurements with OLCR, FD-OCT, and SC. The results were compared using an ANOVA test. Bland-Altman analysis was used to demonstrate agreement between methods. Intra-examiner repeatability was assessed by using intraclass correlation coefficients (ICCs). Results: Statistically significant differences were observed between the results of the CCT measurements obtained using the three different devices (p=0.009). Significant correlations were found between OLCR and FD-OCT (r=0.97; p<0.0001), FD-OCT and SC (r=0.91; p<0.0001), and OLCR and SC (r=0.95; p<0.0001). The 95% limits of agreement (LOA) obtained from Bland-Altman plots were from -7.2 μm to 28.7 μm for OLCR versus FD-OCT, from -19.2 μm to 30.4 μm for OLCR versus SC, and from -42.6 to 32.3 μm for FD-OCT versus SC. Intra-examiner repeatability was excellent for each method, with ICCs >0.98. Conclusion: Although the results of CCT measurements obtained from these three devices were highly correlated with one another and the mean differences between instruments were comparable with the reported diurnal CCT fluctuation, the measurements are not directly interchangeable in clinical practice because of the wide LOA values. .


Objetivo: Comparar os resultados de medições de espessura corneana central (CCT ) obtidos com reflectometria óptica de baixa coerência (OLCR), tomografia de coerência óptica de domínio Fourier (FD-OCT ), e uma câmera Scheimpflug (SC), combinada com topografia corneana de placido. Métodos: Um olho de cada de 25 indivíduos saudáveis foram incluídos neste estudo. Um exame oftalmológico detalhado foi realizado em todos os casos após as medidas de CCT com OLCR, FD-OCT, e SC. Os resultados foram comparados por meio do teste ANOVA. Análise de Bland-Altman foi utilizada para demonstrar concordância entre os métodos. A repetibilidade intra-examinador foi avaliada por meio de coeficientes de correlação intraclasse (ICCs). Resultados: Foram observadas diferenças estatisticamente significativas entre os resultados das medidas de CCT obtidas a partir de três dispositivos diferentes (p=0,009). Foram encontradas correlações significativas entre OLCR e FD-OCT (r=0,97, p<0,0001), FD-OCT e SC (r=0,91, p<0,0001), e OLCR e SC (r=0,95; p<0,0001). Os limites de 95% de confiança (LOA) obtidos a partir de gráficos de Bland-Altman foram de -7,2 a 28,7 μm para OLCR contra FD-OCT, de -19,2 a 30,4 μm para OLCR contra SC, e de -42,6 a 32,3 μm para FD-OCT contra SC. A repetibilidade intra-examinador foi excelente para cada método com ICCs>0,98. Conclusões: Apesar de os resultados das medições CCT obtidos a partir destes três dispositivos terem sido altamente correlacionados entre si e as diferenças médias entre os instrumentos serem comparáveis à flutuação relatado da CCT diurna, as medições não são diretamente intercambiáveis na prática clínica em razão da largura dos valores limites de confiança. .


Assuntos
Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Córnea/anatomia & histologia , Paquimetria Corneana/instrumentação , Paquimetria Corneana/métodos , Topografia da Córnea/métodos , Tomografia de Coerência Óptica/métodos , Análise de Variância , Anatomia Transversal , Biometria/instrumentação , Biometria/métodos , Topografia da Córnea/instrumentação , Análise de Fourier , Variações Dependentes do Observador , Fotografação/instrumentação , Valores de Referência , Reprodutibilidade dos Testes , Estatísticas não Paramétricas
9.
Arq. bras. oftalmol ; 76(6): 354-356, nov.-dez. 2013. graf, tab
Artigo em Inglês | LILACS | ID: lil-701286

RESUMO

PURPOSE: To identify the correlation between the difference of intraocular pressure measurements (IOP) obtained using the Goldmann applanation tonometer (GAT) and three others tonometers (Handheld applanation tonometer - HAT, Dynamic contour tonometer - DCT and Tono-Pen®) with biometric characteristics (corneal diameter, pachymetry, keratometry and axial length) in patients with congenital glaucoma. METHODS: A cross-sectional study was performed on 46 eyes from 46 patients with congenital glaucoma. IOP measurements were obtained in all patients using GAT, HAT, DCT and Tono-Pen®. Keratometry, pachymetry, biometry and corneal diameter measurements were performed after the IOP measurement. The order of the tonometries was randomized. The correlations between the differences of IOP values of GAT and the other tonometers (Delta-IOP), and the different biometric parameters were studied. RESULTS: Tono-Pen® Delta IOP revealed moderate positive correlation to keratometry (r=0.41, p=0.004). The other Delta-IOPs showed no correlation with any of the biometric characteristics evaluated. CONCLUSIONS: IOP differences between GAT (gold standard) and GAT, HAT, DCT or Tono-Pen tonometers seem not to correlate with majority of ocular biometric characteristics. The only exception was the keratometry, which correlated in a positive and moderate way with Tono-Pen® Delta-IOP. This result suggests that the differences of IOP values of Tono-Pen® and GAT increase with the steepness of the cornea.


OBJETIVOS: Identificar correlações entre as diferenças de medições de pressão intraocular (IOP) obtidas usando o tonômetro de aplanação de Goldmann (GAT) e três outros tonômetros (Tonômetro portátil de aplanação - TPA, Tonômetro de contorno dinâmico - TCD e Tono-Pen®) com características biométricas (diâmetro corneano, paquimetria, ceratometria e comprimento axial) em pacientes com glaucoma congênito. MÉTODOS: Estudo transversal prospectivo foi realizado em 46 olhos de 46 pacientes com glaucoma congênito. As medidas de pressão intraocular foram obtidas em todos os pacientes utilizando TAG, TPA, TCD e Tono-Pen®. Ceratometria, paquimetria, biometria e diâmetro corneano foram realizadas após mensuração da pressão intraocular. A ordem da utilização tonômetros foi aleatória. Correlações entre as diferenças de valores de PIO entre cada um dos três tonômetros (PIOs Delta) e o tonômetro de Goldmann e as características biométricas foram analisadas. RESULTADOS: PIO Delta do Tono-Pen®revelou correlação positiva moderada com ceratometria (r=0,41, p=0,004). As outras PIOs Delta não se correlacionaram significativamente com nenhuma das características biométricas. CONCLUSÕES: As diferenças entre as PIOs obtidas pelo TAG (padrão ouro) e TPA, TCD e Tono-Pen®parece não se correlacionar com a maioria das características biométricas. A única exceção foi a ceratometria, a qual se correlacionou de forma positiva e moderada com a PIO Delta do Tono-Pen®. Estes resultados indicam que o aumento da diferença entre a PIO obtida com TAG e Tono-Pen®aumenta com o encurvamento da curvatura corneana.


Assuntos
Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Adulto Jovem , Biometria/instrumentação , Córnea/patologia , Glaucoma/congênito , Pressão Intraocular/fisiologia , Tonometria Ocular/instrumentação , Biometria/métodos , Estudos Transversais , Glaucoma/patologia , Ceratocone/diagnóstico , Tamanho do Órgão , Valores de Referência , Reprodutibilidade dos Testes , Tonometria Ocular/métodos
10.
Rev. bras. plantas med ; 15(2): 169-175, 2013. graf, tab
Artigo em Português | LILACS | ID: lil-677022

RESUMO

Objetivou-se com este trabalho fazer a caracterização biométrica de frutos e sementes de melão-de-são-caetano (Momordica charantia L.) e determinar as temperaturas cardinais para germinação das sementes desta espécie. A caracterização e a condução do experimento foram realizadas no Laboratório de Análise de Sementes da UFERSA, em Mossoró-RN. Os parâmetros avaliados foram: comprimento, diâmetro, número de sementes por fruto; comprimento, largura e espessura das sementes; grau de umidade, peso de mil sementes, e número de sementes por grama. Para o ensaio sobre as temperaturas, a semeadura foi realizada em caixas plásticas transparentes contendo areia esterilizada como substrato. As sementes foram incubadas nas temperaturas constantes de 10ºC, 15ºC, 20ºC, 25ºC, 30ºC, 35ºC e 40ºC, com fotoperíodo de 8 horas. O delineamento experimental foi inteiramente casualizado com quatro repetições de 50 sementes. Os frutos apresentam cerca de 49,8 mm de comprimento, 19,89 mm de diâmetro, contendo em torno de 18 sementes. As dimensões médias das sementes são: 8,9mm de comprimento, 4,30mm de largura, e 2,65mm de espessura. A germinação ocorre na faixa de 20 a 35ºC, porém as temperaturas ótimas para germinação de sementes de melão-de-são-caetano variam entre 25 e 30ºC.


The aims of this study were to perform the biometric characterization of fruits and seeds of balsam pear (Momordica charantia L.) and to determine the cardinal temperatures for seed germination in this species. The characterization and the experiment were conducted at the Laboratory of Seed Analysis of UFERSA in Mossoró-RN. The evaluated parameters were: length, width and thickness of seeds; moisture content; one thousand seed weight; and number of seeds per gram. For the temperature assay, sowing was done in transparent plastic boxes containing sterilized sand as substrate. The seeds were then incubated at the constant temperatures of 10ºC, 15°C, 20°C, 25°C, 30°C, 35°C and 40°C, with 8-hour photoperiod. Experimental design was completely randomized with four replicates of 50 seeds. Fruits have about 49.8mm length and 19.89 mm diameter, containing around 18 seeds. The medium dimensions of seeds are: 8.9mm length, 4.30 mm width and 2.65 mm thickness. There is germination in the range from 20 to 35ºC, but the optimal temperatures for the germination of balsam pear seeds vary between 25 and 30°C.


Assuntos
Biometria/instrumentação , Germinação , Momordica charantia/metabolismo , Sementes/crescimento & desenvolvimento
11.
Braz. j. vet. res. anim. sci ; 48(4): 307-314, ago. 2011.
Artigo em Português | LILACS | ID: lil-642201

RESUMO

A espécie ovina é largamente utilizada na região Nordeste do Brasil por apresentar alta rusticidade. No entanto, sua anatomia ainda é pouco estudada. Assim, crescem os estudos para gerar subsídios técnico-científicos àqueles profissionais que trabalham com as áreas aplicadas da Medicina Veterinária e afins. O objetivo do presente estudo foi estabelecer correlações entre as dimensões da cabeça e da cavidade craniana, utilizando 80 ovinos, 40 machos e 40 fêmeas, com média de peso entre 27,0 e 33,0 kg. Em fêmeas, foi observada correlação entre a massa corpórea e o comprimento da cabeça; entre a massa corpórea e largura da cabeça; entre o comprimento da cabeça e sua respectiva largura; entre comprimento da cabeça e o comprimento da cavidade craniana e entre a altura da cabeça e o comprimento da cavidade craniana. As demais dimensões, nas fêmeas, não tiveram correlação estatisticamente significativa. Já em animais do sexo masculino, foi possível evidenciar correlação apenas entre a altura da cabeça e altura da cavidade craniana. Desta forma, é possível concluir que, quanto maiores forem as proporções da cabeça, maiores serão as dimensões e volume intracranianos.


The sheep is a commonly used species in Northeast region of Brazil because of its high rusticity. Yet, very little is known about the anatomy of these species. Therefore, the number of studies in this field is increasing to stimulate technical and scientific subsidies to professionals in Veterinary Medicine. The aim of this study was to establish correlations between the head and cranial cavity dimensions, using 80 sheep, 40 males and 40 females, with a medium weight of 27,0 to 33,0 kg. In females, it was observed correlation between corporal weight and length of the head; corporal weight and width of the head; length of the head and its respective width; length of the head and length of the cranial cavity; height of the head and length of the cranial cavity. The other dimensions, in females, had non-significant correlation. In males, the only correlation established was between height of the head and height of the cranial cavity. Thus, it was possible to conclude that the larger the proportions of the cranium are, the larger will be the dimensions and the intracranial volume.


Assuntos
Animais , Biometria/instrumentação , Cavidades Cranianas/anatomia & histologia , Ovinos/classificação , Estatura , Cabeça/anatomia & histologia
12.
Braz. j. vet. res. anim. sci ; 48(4): 319-324, ago. 2011.
Artigo em Inglês | LILACS | ID: lil-642203

RESUMO

Little is known regarding the seasonal semen production of Lacaune rams in southern Brazil. Thus, the aim of this study was to evaluate semen quality and production of Lacaune rams maintained in Rio Grande do Sul (RS). Semen was collected using an artificial vagina, from 12 rams (1 to 4 years of age), kept under intensive conditions. The quantitative and qualitative characteristics of the semen and scrotal circumference of each ram were recorded, from the winter of 2002 to the spring of 2003. Seasonal variations were recorded in almost all the monitored semen characteristics and in scrotal circumference. Sperm concentration was the only semen characteristic evaluated that did not show seasonal variation. Sperm volume varied between 1.1 ± 0.4 mL (winter of 2002) and 1.5 ± 0.4 mL (autumn of 2003). Total number of sperm per ejaculate varied between 4.0 ± 3.3x109 (winter of 2002) and 5.7 ± 3.3x109 (summer of 2003). For scrotal circumference records, in 2002 significant differences between seasons were observed. Significant differences were also found in accordance with the age of rams (P < 0.05) in the winter of 2002. Results showed improvement in motility, concentration and volume of the sperm during summer and autumn when compared to spring and winter. So, in this region of Brazil summer and autumn are the more indicated seasons to maximize the utilization of Lacaune rams for reproductive practices. Further studies must be done to evaluate Lacaune semen freezability in these seasons of the year.


Existem poucos dados sobre a produção de sêmen da raça Lacaune, no sul do país. Assim, o objetivo deste estudo foi o de avaliar a produção e a qualidade do sêmen de carneiros desta raça, criados no estado do Rio Grande do Sul (RS). Foram utilizados 12 carneiros, de idades entre 1-4 anos, criados em condições intensivas. O sêmen foi colhido por vagina artificial e foram avaliadas as características quantitativas e qualitativas e a circunferência escrotal, do inverno de 2002 até a primavera de 2003. Com exceção da concentração espermática, foram observadas variações estacionais em todas as características estudadas. O volume variou de 1.1 ± 0.4 mL, no inverno de 2002, a 1.5 ± 0.4 mL no outono de 2003. O número total de espermatozóides por ejaculado variou de 4.0 ± 3.3x109 (inverno de 2002) a 5.7 ± 3.3x109 (verão de 2003). Observou-se variação estacional significativa (P < 0,05) na circunferência escrotal em 2002, bem como variação significativa entre as idades dos animais, no inverno do mesmo ano. Os valores médios da produção espermática observados no verão e o outono foram superiores aos obtidos no inverno e primavera. O verão e outono foram considerados as estações mais indicadas para a utilização de machos da raça Lacaune em programas reprodutivos, no RS. Mais estudos devem ser conduzidos, para a verificação de efeitos estacionais sobre o congelamento do sêmen.


Assuntos
Animais , Ovinos/classificação , Reprodução/fisiologia , Sêmen/citologia , Biometria/instrumentação
13.
Braz. j. vet. res. anim. sci ; 48(4): 332-335, ago. 2011.
Artigo em Inglês | LILACS | ID: lil-642205

RESUMO

The effect of age, follicular diameter and month of the breeding season (September to January) on the hCG induction of ovulation was evaluated using 123 Criollo mares. Age varied between two and 24 years and the animals were examined daily by rectal palpation and ultrasonography with a 5 MHz linear transducer. When ovarian follicles reached a diameter of 30 to 35 mm, ovulation was induced with an i.v. injection of 1000 IU (n = 39); 1500 IU (n = 41) or 2000 IU (n = 43) of hCG. The mares were bred the next day and examined daily until ovulation was detected. The percentage of mares ovulating before 24 h of hCG injection was 10.3%, 7.3% and 4.7%; until 48 h after injection 92.3%, 85.3% and 86.0% of the mares treated with 1000, 1500 and 2000 IU of hCG, respectively, ovulated. The month of the breeding season, age of the mares and follicular diameter had no influence on ovulatory response. The three hCG doses used in Criollo mares (P > 0.05) result in the induction of ovulation within 48 h after injection when a pre-ovulatory follicle with a 30 to 35 mm diameter was identified. A single dose of 1000 IU of hCG is efficient to induce ovulation in Criollo mares.


O efeito da idade, diâmetro folicular e mês da estação de monta (setembro a janeiro) na indução da ovulação com hCG foi avaliado em 123 éguas Crioulas. A idade das éguas variou entre dois e 24 anos e os animais foram examinados diariamente por palpação retal e ultrassonografia com transdutor linear de 5 MHz. Quando os folículos ovarianos atingiram diâmetro de 30 a 35 milímetros aplicou-se uma injeção intravenosa com 1000 UI (n = 39); 1500 UI (n = 41) ou 2000 UI (n = 43) de hCG. As éguas foram cobertas no dia seguinte e examinadas diariamente até a detecção da ovulação. O percentual de éguas que ovularam antes de 24 h da injeção de hCG foi de 10,3%, 7,3% e 4,7%, até 48h após a injeção foi de 92,3%, 85,3% e 86,0%, nos grupos com 1000, 1500 e 2000 UI de hCG, respectivamente. O mês da estação de monta, a idade das éguas ou o diâmetro folicular não influenciaram a resposta ovulatória. As três doses de hCG utilizadas em éguas Crioulas (P > 0,05) resultaram na indução da ovulação dentro de 48h após a aplicação, quando foi identificado um folículo pré-ovulatório de 30 a 35 mm de diâmetro. Uma única dose de 1000 UI de hCG é eficiente para induzir a ovulação em éguas Crioulas.


Assuntos
Animais , Cavalos/classificação , Ovulação/fisiologia , Biometria/instrumentação , Gonadotropina Coriônica
14.
Artigo em Português | LILACS | ID: biblio-964402

RESUMO

O presente artigo analisa criticamente os usos e abusos dos testes estatísticos de comparação entre médias, bem como sugere novos enfoques metodológicos para a coleta e análise de dados objetivando alcançar resultados mais fidedignos.


This paper critically examines the uses and abuses of statistical tests to compare means, and suggests new methodological approaches to collect and analyze data in order to achieve more reliable results.


Assuntos
Pesquisa/estatística & dados numéricos , Bioestatística/instrumentação , Biometria/instrumentação
15.
Journal of Preventive Medicine and Public Health ; : 479-485, 2010.
Artigo em Inglês | WPRIM | ID: wpr-103490

RESUMO

OBJECTIVES: The Korean Genome and Epidemiology Study (KoGES), a multicenter-based multi-cohort study, has collected information on body composition using two different bioelectrical impedence analysis (BIA) machines. The aim of the study was to evaluate the possibility of whether the test values measured from different BIA machines can be integrated through statistical adjustment algorithm under excellent inter-rater reliability. METHODS: We selected two centers to measure inter-rater reliability of the two BIA machines. We set up the two machines side by side and measured subjects' body compositions between October 2007 and December 2007. Duplicated test values of 848 subjects were collected. Pearson and intra-class correlation coefficients for inter-rater reliability were estimated using results from the two machines. To detect the feasibility for data integration, we constructed statistical compensation models using linear regression models with residual analysis and R-square values. RESULTS: All correlation coefficients indicated excellent reliability except mineral mass. However, models using only duplicated body composition values for data integration were not feasible due to relatively low R2 values of 0.8 for mineral mass and target weight. To integrate body composition data, models adjusted for four empirical variables that were age, sex, weight and height were most ideal (all R2>0.9). CONCLUSIONS: The test values measured with the two BIA machines in the KoGES have excellent reliability for the nine body composition values. Based on reliability, values can be integrated through algorithmic statistical adjustment using regression equations that includes age, sex, weight, and height.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Biometria/instrumentação , Composição Corporal , Estudos de Coortes , Impedância Elétrica , Genoma Humano , Variações Dependentes do Observador , Reprodutibilidade dos Testes , República da Coreia
16.
Artigo em Inglês | IMSEAR | ID: sea-41807

RESUMO

OBJECTIVE: To construct reference ranges of fetal ocular distance (interocular and binocular distance) and to evaluate the relationships between the gestational ages and fetal ocular distance. MATERIAL AND METHOD: Six hundred and two normal pregnant women were evaluated from the 15th to 40th week of gestation. Fetal ocular distance (interocular and binocular distances) was added to routine biometric measurements for normal fetuses. The fetal ocular distance (interocular and binocular distances) was also related to gestational age. RESULTS: Five hundred and ninety five measurements were used for analyses. A linear regression and correlation were observed between gestational age (GA) and interocular distance (y = 2.304 + 0.510 x GA, R2 = 0.887; p < 0.0001), and binocular distance (y = 2.590 + 1.420 x GA, R2 = 0.953; p < 0.0001). A linear growth function was observed between biparietal diameter (BPD) and both interocular distance (y = 2.854 + 0.203 x BPD, R2 = 0.888; p < 0.0001), and binocular distance (y = 3.893 + 0.568 x BPD, R2 = 0.965; p < 0.0001). CONCLUSION: The present study provides normative data of fetal interocular distance and binocular distance. These data may be helpful in detection of fetal hypotelorism or hypertelorism.


Assuntos
Adulto , Biometria/instrumentação , Oftalmopatias/diagnóstico , Feminino , Feto/anatomia & histologia , Idade Gestacional , Humanos , Modelos Lineares , Gravidez , Estudos Prospectivos , Valores de Referência , Fatores de Risco , Ultrassonografia Pré-Natal , Visão Binocular/fisiologia
17.
Rev. Salusvita (Online) ; 27(1): 29-44, 2008. ilus, mapas, graf, tab
Artigo em Português | LILACS | ID: lil-562315

RESUMO

Realizou-se o levantamento da ictiofauna existente na lagoa de captação de água do DAE (Departamento de Água e Esgoto) entre os meses de março e julho de 2005, sendo registradas 11 espécies, distribuídas em 9 famílias e 5 ordens. A ordem Characiformes, com sete espécies, foi a mais representativa, enquanto que Acestrorrynchuslacustris e Astyanax bimaculatus foram as espécies mais abundantese freqüentes. As espécies capturadas foram submetidas à biometria. Para isso, foram determinados cinco parâmetros da anatomia externa dos animais para compor uma base de dados para cada espécie, metodologia proposta por Gallego et al. (1995), calculando os índices anatômicos que possibilitaram a avaliação desse programa como chave taxonômica numérica. A partir disto, nove indivíduos, chamados “espécimes-problema”, foram submetidos ao programa etiveram seus índices comparados, sendo a maioria determinada com sucesso. Neste estudo, a biometria mostrou-se uma importante ferramenta para a caracterização e discussão sobre a proximidade entre as espécies.


This survey was carried out to describe the composition of fish community in the Lagoon of Reception of Water of DAE between the months of March and July of 2005. A total of 11 species were registered, distributed in 9 families and 5 orders. The order Characiformes, with 7 species, was the most representative, while Acestrorrynchus lacustris and Astyanax bimaculatus were the most abundant species with relationship to the frequency. The captured species were submitted to the biometric analysis. For this, 5 parameters of the external anatomy of the animals were considerate to compose a base of data for each species, according to the methodology proposed by Gallego et al. (1995). The anatomical indexes were calculated to enable an evaluation of this program like a numeric taxonomic key.Then, 9 individuals, called “specimens-problem”, were submitted to the program and had your compared indexes. The most of the specimens was resolved with success. In this study, the biometry was shown as an important tool for the characterization and discussion about the proximity between the species.


Assuntos
Animais , Biometria/instrumentação , Fauna Aquática , Peixes/classificação , Biodiversidade , Ecologia , Rios
18.
Artigo em Inglês | IMSEAR | ID: sea-44027

RESUMO

OBJECTIVE: To compare the performance of the Conventional Biometry (CB) (Applanation Ultrasound and Keratometry) and the Integrated Laser Interferometry with Keratometry Device (LI) in the measurement of Intraocular Lens (IOL). MATERIAL AND METHOD: A prospective study of 100 eyes in 50 cataract patients was conducted. The IOL measurement using the LIfollowed by the CB was done on all eyes. The keratometry (K), axial length (AL), IOL power, and time required for both methods were compared in the same subject by ANOVA with repeated measurement. RESULTS: The LI could not obtain the AL in 14%. There were 21% that the signal to noise ratio was below 1.6. The AL obtained by the LI was significant higher compared to the CB by mean of 0.28 mm (p < 0.05). The K showed no statistically significant difference (p = 0.05). There was statistically significantly higher IOL power calculated by the LI compared to the CB by mean of 0.63 D (p < 0.05). The time required for the LI was 2.77 +/- 1.44 min and the CB was 9.63 +/- 3.82 min (p < 0. 05). CONCLUSION: The LI required less time than the CB in measurement of the IOL but could not measure the AL in the group of patients with dense cataracts. The LI give a higher IOL power compared to the CB.


Assuntos
Biometria/instrumentação , Topografia da Córnea/instrumentação , Feminino , Humanos , Interferometria/instrumentação , Lasers , Implante de Lente Intraocular/instrumentação , Lentes Intraoculares , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA