Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Arq. bras. med. vet. zootec. (Online) ; 71(4): 1316-1326, jul.-ago. 2019. tab, graf
Artigo em Português | LILACS, VETINDEX | ID: biblio-1038610

RESUMO

O presente trabalho objetivou comparar o efeito do flunixin meglumine, cetoprofeno e meloxicam no tratamento da dor pós-operatória de ovinos submetidos à implantação de cânula ruminal e orquiectomia. Foram utilizados 32 ovinos, machos, pesando em média 35,5±3,5kg, distribuídos em três grupos: GFlu (flunixin meglumine 1,1mg/kg i.v.), GCet (cetoprofeno 3,0mg/kg i.v.) e GMel (meloxicam 0,5mg/kg i.v.). Exame clínico e coletas de sangue foram realizados no M0 (pré-avaliação), M1 (10 minutos após a pré-avaliação), M2 (início da sutura para fixação da cânula ruminal), M3 (logo após o término da cirurgia) e em duas, 12, 23, 25, 48 e 72 horas após a cirurgia (M2h, M12h, M23h, M25h, M48h e M72h), quando foram avaliados cortisol, glicose, proteína total, albumina, γ-glutamiltransferase (GGT), aspartato aminotransferase (AST), creatina quinase (CK), ureia, creatinina e hemograma. Nos M2h, M12h, M23h, M25h e M48h, foi realizada avaliação comportamental. O GFlu apresentou maior concentração de cortisol no M12h e no M48h e maior escore de dor na fístula e no testículo no M12h, quando comparado ao GMel. Os animais do GCet apresentaram menor interação com outros membros da baia no M23h. A ação analgésica do meloxicam foi maior em animais submetidos à implantação de cânula ruminal e orquiectomia, quando comparado ao flunixin meglumine e ao cetoprofeno.(AU)


This study aimed to compare the effect of flunixin meglumine, ketoprofen, and meloxicam in the treatment of postoperative pain in sheep submitted to ruminal cannulation and orchiectomy. 32 sheep were submitted to implantation of rumen cannula and orchiectomy, divided into three groups: GFlu (Flunixin meglumine 1,1mg/kg i.v.); GCet (Ketoprofen 3,0mg/kg i.v.); GMel (Meloxicam 0,5mg/kg i.v.). Clinical examination and blood samples were performed at M0 (pre-evaluation), M1 (10 minutes after pre-evaluation), M2 (beginning ruminal cannula), M3 (immediately post-surgery), and M2h, M12h, M23h, M25h, M48h and M72h (2h, 12h, 23h, 25h, 48h and 72 hours post-surgery) with the evaluation of cortisol, glucose, total protein, albumin, γ-glutamyl transferase (GGT), aspartate aminotransferase (AST), creatine kinase (CK), urea, creatinine and blood count. At M2h, M12h, M23h, M25h and M48h a behavioral evaluation was performed. The GFlu showed higher concentration of cortisol at M12h and M48h and greater pain score related with fistula and testis procedures at M12h when compared to GMel. Animals in the GCet group presented lower interaction with other animals in the same M23h paddock. The analgesia provided by Meloxicam was higher than flunixin meglumine and ketoprofen in animals submitted to placement of ruminal cannula and orchiectomy.(AU)


Assuntos
Animais , Estresse Fisiológico , Ovinos , Cateterismo/veterinária , Orquiectomia/veterinária , Anti-Inflamatórios não Esteroides/administração & dosagem , Meloxicam/uso terapêutico , Bem-Estar do Animal
2.
Arq. bras. med. vet. zootec ; 68(3): 611-619, tab, graf
Artigo em Português | LILACS, VETINDEX | ID: lil-785682

RESUMO

Após validação de dois diferentes métodos de mensuração de pressão arterial sistólica (PAS) não invasivos ou indiretos (oscilométrico e Doppler vascular) com o invasivo ou direto (cateterização arterial - padrão ouro) em 12 gatos hígidos anestesiados de mesma faixa etária, os métodos não invasivos foram avaliados e comparados em 24 gatos hígidos e conscientes, divididos em quatro grupos de idade. Em cada animal, procedeu-se à mensuração da pressão pelos métodos Doppler e oscilométrico. O método oscilométrico foi o primeiro a ser realizado, e, logo em seguida, o método Doppler. Os valores considerados foram obtidos das médias de sete medidas consecutivas para cada método, com intervalo de 30 segundos entre elas. A primeira medida e as medidas discrepantes (variação ˃ 20% PAS), obtidas com sinais óbvios de estresse e/ou com movimentação do animal, foram descartadas. Os métodos de mensuração oscilométrico e Doppler, embora tenham apresentado médias estatisticamente diferentes em todos os grupos, quando comparados em cada grupo, apresentaram uma correlação significativa, alta e positiva. Ou seja, sempre que for obtido um valor elevado por um método, o mesmo fato ocorrerá com o outro método e vice-versa. Clinicamente, a diferença observada não é relevante, uma vez que a diferença média dos valores obtida pelos dois métodos, em cada grupo, foi menor que 1,1%.(AU)


After two different validation systolic blood pressure measurement methods (PAS), not invasive or indirect (oscillometric and doppler vascular) with invasive or direct (arterial catheterization - Gold Standard) in 12 anesthetized healthy cats of the same age group, not invasive methods were evaluated and compared in 24 healthy conscious cats, divided into four age groups. In each animal, we proceeded to measure the pressure by Doppler and oscillometric methods. The oscillometric method was the first to be performed, and, shortly thereafter, the doppler method. The values considered were obtained from averages from seven consecutive measurements for each method with an interval of thirty seconds between them. The first measurement and disparate measurements (range ˃ 20% PAS) obtained with obvious signs of stress and / or animal movement were discarded. Methods of oscillometric and doppler measurement, although statistically different averages were shown in all groups when compared, each group showed a significant high positive correlation, meaning that when a high value is obtained by a method, the same occurs with the other method, and vice versa. Clinically, the observed difference is not relevant since the mean difference values obtained by the two methods, in each group was lower than 1.1%.(AU)


Assuntos
Animais , Gatos , Anestesia/veterinária , Pressão Arterial , Pressão Sanguínea , Cateterismo/veterinária , Oscilometria/veterinária , Hipertensão/veterinária , Fenômenos Fisiológicos
3.
Pesqui. vet. bras ; 30(10): 861-867, out. 2010. tab
Artigo em Português | LILACS | ID: lil-567930

RESUMO

To develop a model of hemodialysis (HD), 18 healthy dogs, without a defined breed, males, weighing 7-14 kg, were studied. A double lumen catheter was inserted into the jugular vein for vascular access. HD sessions, totalizing 5 for each dog, were performed with a proportional HD machine, controlled isovolemic ultrafiltration, standard dialysis solution and bicarbonate buffer. Sodium profile and sodium heparin were used. During HD sessions the dogs were kept anesthetized (levomepromazine and propofol). Hematological and biochemistry data, blood gas analysis, systemic arterial blood pressure, and activated clotting time were evaluated. Serum biochemistry e blood gas analysis showed, respectively, sodium and SO2 maintenance. Systemic blood pressure kept sustained during HD sessions. It could be concluded that it was possible to develop a HD dog model that is a safe and viable technique to be used in chronic renal failure patients.


Com o objetivo de desenvolver um modelo de hemodiálise (HD) em cães, foram estudados 18 animais, sem raça definida, machos, clinicamente sadios, com peso corporal variando entre sete e 14 kg. O acesso vascular foi obtido através de implantação do cateter de duplo lúmen em veia jugular externa. As sessões de HD, em número de cinco por animal, com até três horas de duração, foram realizadas em hemodialisadora de sistema proporcional com ultrafiltração (UF) controlada, com solução dialisante padrão e tampão bicarbonato. A UF foi ajustada para HD isovolêmica, utilizou-se perfil de sódio, e para anticoagulação heparina sódica. Os animais foram mantidos anestesiados com cloridrato de levomepromazina e propofol. Foram avaliados dados hematológicos, bioquímicos, hemogasometria, pressão arterial sistêmica e tempo de coagulação ativado. Foi observada diminuição do número global de hemácias, volume globular, hemoglobina e leucócitos. Em relação aos exames bioquímicos, houve manutenção nos níveis de sódio sérico, e quanto à hemogasometria, a manutenção da SO2. A pressão arterial sistêmica manteve-se constante. Os resultados obtidos no presente trabalho permitiram concluir que foi possível o desenvolvimento do modelo proposto e mostrou que a HD em cães é um método viável e seguro, que poderá contribuir para o tratamento clínico da insuficiência renal nesta espécie.


Assuntos
Animais , Masculino , Adulto , Cateterismo/métodos , Cateterismo/veterinária , Diálise Renal/métodos , Diálise Renal/veterinária
4.
Rev. bras. ciênc. vet ; 15(3): 129-133, set.-dez. 2008. tab
Artigo em Português | LILACS | ID: lil-519321

RESUMO

Com o objetivo de realizar adequação da técnica de hemodiálise para a espécie eqüina, foram formados quatro grupos experimentais de seis animais cada, sendo os tratamentos: Grupo I: animais submetidos a cateterismo central unilateral e protocolo de sedação (controle); Grupo II: animais submetidos a cateterismo central unilateral com cateter duplo-lúmen e uma sessão de hemodiálise de seis horas; Grupo III: animais submetidos a cateterismo central unilateral com cateter duplo-lúmen e duas sessões de hemodiálise de seis horas; Grupo IV: animais submetidos a cateterismo central bilateral com cateter mono-lúmen e uma sessão de hemodiálise de seis horas. Empregou-se xilazina 10 por cento (0,4 mg/kg) associada a acepromazina 2 por cento (0,08 mg/kg) via intravenosa para sedação. Foram utilizados dois hemodialisadores em série, do tipo fibras ocas, e o fluxo sanguíneo foi de 319,18 ± 97,41 mL/minuto. A anticoagulação foi feita com heparina sódica em 100 UI/kg para primming, repetida na dose de 53,86 ± 18,61 UI/kg/hora. Dentre as respostas pesquisadas neste estudo, na avaliação hematológica não foram observadas alterações do leucograma (contagem global e diferencial dos leucócitos e avaliação da morfologia celular). Concluiu-se que a técnica de hemodiálise pode ser empregada na espécie eqüina, utilizando-se dialisadores de polissulfona, com tempo de seis horas em cada sessão de diálise, sem causar alterações hematológicas no leucograma.


With the goal of promote hemodialysis technical adequacy for horses, four experimental groups with six animals was formed, and the folowing treatments was applied: Group I: horses submited to unilateral central venous catheter and a sedation protocol (control group); Group II: horses submited to unilateral central venous double lumen catheter and one session of six hours hemodialysis; Group III: horses submited to unilateral central venous double lumen catheter and two sessions of six hours hemodialysis; Group IV: horses submited to bilateral central venous mono lumen catheter and one in session of six hours hemodialysis. Xilazine 10 percent (0,1 ml/50 kg) associated with acepromazine 2 percent (0,1 ml/50 kg) was done by venous rote for sedation. Two hollow fiber, low flux polyssulfone of 1,8m2 was used in serie connexion. The mean blood flux was 319,18 ± 97,41 ml/min. Antiocoagulation was performed with sodium heparin, 100 UI/kg for primming and at the dose of 53,86 ± 18,61 UI/kg/hr. For the evaluation performed in this study, in the blood analysis was not observed leukogram alterations (global and differential leukocytes counts and celular morphology evaluation). Was concluded that hemodialysis can be applied for horses by using polyssulfone dializers in six hours dialysis session, without leading hematological.


Assuntos
Animais , Feminino , Cateterismo/veterinária , Cavalos/sangue , Diálise Renal/veterinária , Hematologia
5.
Rev. bras. ciênc. vet ; 15(2): 72-76, maio-ago. 2008. tab
Artigo em Português | LILACS | ID: lil-521216

RESUMO

Com o objetivo de realizar a adequação da técnica de hemodiálise para eqüinos, foram formados quatro grupos experimentaisde seis animais cada, sendo determinados os seguintes tratamentos: Grupo I: animais sadios submetidos a cateterismocentral unilateral e protocolo de sedação (grupo controle); Grupo II: animais sadios submetidos a cateterismo central unilateralcom cateter duplo-lúmen e uma sessão de hemodiálise de seis horas; Grupo III: animais sadios submetidos a cateterismocentral unilateral com cateter duplo-lúmen e duas sessões de hemodiálise de seis horas; Grupo IV: animais sadios submetidosa cateterismo central bilateral com cateter mono-lúmen e uma sessão de hemodiálise de seis horas. Empregou-se xilazina10% (0,4 mg/kg) associada a acepromazina 2% (0,08 mg/kg) via intravenosa para sedação. Foram utilizados doishemodialisadores dispostos em série, do tipo fibras ocas, baixo fluxo, membrana de polissulfona e área de 1,8m2. O fluxosanguíneo médio do circuito extracorpóreo foi de 319,18 ± 97,41 ml/minuto. A anticoagulação foi feita com heparina sódica em100 UI/kg para primming, repetida na dose de 53,86 ± 18,61 UI/kg/hora. Dentre as respostas pesquisadas neste estudo, naavaliação hematológica observou-se diminuição nos valores de eritrócitos e índices hematimétricos, sendo estes achadoscondizentes com o emprego de um circuito extracorpóreo. Concluiu-se que o procedimento de hemodiálise pode ser empregadona espécie eqüina, empregando-se a técnica clássica descrita neste trabalho. Contudo, a avaliação hematológica antes edepois de cada sessão de diálise é fundamental para monitorização do paciente.


With the goal of promote hemodialysis technical adequacy for horses, four experimental groups with six animals was formed,and the folowing treatments was applied: Group I: horses submited to unilateral central venous catheter and a sedation protocol(control group); Group II: horses submited to unilateral central venous double lumen catheter and one session of six hourshemodialysis; Group III: horses submited to unilateral central venous double lumen catheter and two sessions of six hourshemodialysis; Group IV: horses submited to bilateral central venous mono lumen catheter and one session of six hourshemodialysis. Xilazine 10% (0,1 ml/50 kg) associated with acepromazine 2% (0,1 ml/50 kg) was done by venous rote forsadation. Two hollow fiber, low flux polyssulfone of 1,8m2 was used in serie connexion. The mean blood flux was 319,18 ± 97,41ml/min. Antiocoagulation was performed with sodium heparin, 100 UI/kg for primming and at the dose of 53,86 ± 18,61 UI/kg/hr.For the evaluation performed in this study, in the blood analysis was observed decrease in eritrocites and hematimetric values.Was concluded that hemodialysis can be applied for horses by using the classical thecnic, described in this work, but, the bloodevaluation before and after this procedure is fundamental for patients monnitoring.


Assuntos
Animais , Masculino , Feminino , Cateterismo/veterinária , Diálise Renal , Diálise Renal/veterinária , Anemia Infecciosa Equina , Eritrócitos , Hematologia , Hipnóticos e Sedativos/administração & dosagem , Sorologia
6.
Rev. bras. ciênc. vet ; 15(2): 72-76, maio-ago. 2008. tab
Artigo em Português | LILACS, VETINDEX | ID: biblio-1491365

RESUMO

Com o objetivo de realizar a adequação da técnica de hemodiálise para eqüinos, foram formados quatro grupos experimentais de seis animais cada, sendo determinados os seguintes tratamentos: Grupo I: animais sadios submetidos a cateterismo central unilateral e protocolo de sedação (grupo controle); Grupo II: animais sadios submetidos a cateterismo central unilateralcom cateter duplo-lúmen e uma sessão de hemodiálise de seis horas; Grupo III: animais sadios submetidos a cateterismo central unilateral com cateter duplo-lúmen e duas sessões de hemodiálise de seis horas; Grupo IV: animais sadios submetidos a cateterismo central bilateral com cateter mono-lúmen e uma sessão de hemodiálise de seis horas. Empregou-se xilazina 10% (0,4 mg/kg) associada a acepromazina 2% (0,08 mg/kg) via intravenosa para sedação. Foram utilizados dois hemodialisadores dispostos em série, do tipo fibras ocas, baixo fluxo, membrana de polissulfona e área de 1,8m2. O fluxo sanguíneo médio do circuito extracorpóreo foi de 319,18 ± 97,41 ml/minuto. A anticoagulação foi feita com heparina sódica em 100 UI/kg para primming, repetida na dose de 53,86 ± 18,61 UI/kg/hora. Dentre as respostas pesquisadas neste estudo, na avaliação hematológica observou-se diminuição nos valores de eritrócitos e índices hematimétricos, sendo estes achados condizentes com o emprego de um circuito extracorpóreo. Concluiu-se que o procedimento de hemodiálise pode ser empregado na espécie eqüina, empregando-se a técnica clássica descrita neste trabalho. Contudo, a avaliação hematológica antes e depois de cada sessão de diálise é fundamental para monitorização do paciente.


With the goal of promote hemodialysis technical adequacy for horses, four experimental groups with six animals was formed,and the folowing treatments was applied: Group I: horses submited to unilateral central venous catheter and a sedation protocol(control group); Group II: horses submited to unilateral central venous double lumen catheter and one session of six hours hemodialysis; Group III: horses submited to unilateral central venous double lumen catheter and two sessions of six hours hemodialysis; Group IV: horses submited to bilateral central venous mono lumen catheter and one session of six hours hemodialysis. Xilazine 10% (0,1 ml/50 kg) associated with acepromazine 2% (0,1 ml/50 kg) was done by venous rote forsadation. Two hollow fiber, low flux polyssulfone of 1,8 m2 was used in serie connexion. The mean blood flux was 319,18 ± 97,41ml/min. Antiocoagulation was performed with sodium heparin, 100 UI/kg for primming and at the dose of 53,86 ± 18,61 UI/kg/hr.For the evaluation performed in this study, in the blood analysis was observed decrease in eritrocites and hematimetric values.Was concluded that hemodialysis can be applied for horses by using the classical thecnic, described in this work, but, the blood evaluation before and after this procedure is fundamental for patients monnitoring.


Assuntos
Animais , Cateterismo/veterinária , Diálise Renal/métodos , Eritrócitos , Hematologia , Anemia Infecciosa Equina , Hipnóticos e Sedativos/administração & dosagem , Sorologia
7.
Journal of Veterinary Science ; : 197-202, 2008.
Artigo em Inglês | WPRIM | ID: wpr-75535

RESUMO

Canine heart worm disease is often life-threatening due to its various complications, including right side heart failure, caval syndrome and pulmonary eosinophilic granulomatosis. Several preventive medications and melarsomine have been developed and they are very effective to control heartworm infestation. However, in a case of severe infestation, melarsomine therapy often results in an unfavorable outcome because of the severe immune reaction caused by rapid killing of the adult worm. Surgical removal and an interventional method using flexible alligator forceps have been well described in the literature. Despite the usefulness of mechanical removal using flexible alligator forceps, the methodology still needs to be upgraded for increasing the applicability for treating dogs with severe infestation. We describe herein a newly developed percutaneous removal method for heartworms and this was successfully applied to 4 dogs with severe heartworm infestation. The follow-up studies also showed favorable outcomes with no complications.


Assuntos
Animais , Cães , Cateterismo/veterinária , Dirofilaria immitis , Dirofilariose/cirurgia , Doenças do Cão/cirurgia , Ecocardiografia , Eletrocardiografia , Fluoroscopia/métodos , Instrumentos Cirúrgicos/veterinária , Procedimentos Cirúrgicos Torácicos/métodos
8.
Indian J Physiol Pharmacol ; 1998 Apr; 42(2): 231-8
Artigo em Inglês | IMSEAR | ID: sea-107706

RESUMO

The present investigation on pancreatic juice (PJ) and duodenal fluid (DF) was carried out in 10 crossbred (Jersey x Kankrej) male cow calves from birth to early ruminant state (15 week). The respective samples were measured in situ by cannulating the pancreatic duct and duodenal lumen, 30 minutes before feeding (BF) and 30 minutes after feeding (AF) both during morning (MH) and evening (EH). The results revealed significant increase in PJ and DF flow rate with age. Diurnal effect was nonsignificant except a significant increase recorded during EH on 4 d for PJ and 3 d for DF.


Assuntos
Envelhecimento/fisiologia , Animais , Animais Recém-Nascidos/fisiologia , Líquidos Corporais/fisiologia , Cateterismo/veterinária , Ritmo Circadiano/fisiologia , Duodeno/fisiologia , Masculino , Ductos Pancreáticos/fisiologia , Suco Pancreático/fisiologia , Rúmen/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA