Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 206
Filtrar
1.
Chinese Medical Sciences Journal ; (4): 349-352, 2022.
Artigo em Inglês | WPRIM | ID: wpr-970700

RESUMO

Autosomal recessive congenital ichthyosis (ARCI) is characterized by being born as collodion babies, hyperkeratosis, and skin scaling. We described a collodion baby at birth with mild ectropion, eclabium, and syndactyly. Whole exome sequencing showed a compound heterozygous variant c.[56C>A], p.(Ser19X) and c.[100G>A], p.(Ala34Thr) in the PNPLA1 gene [NM_001145717; exon 1]. The protein encoded by PNPLA1 acts as a unique transacylase that specifically transfers linoleic acid from triglyceride to ω-hydroxy fatty acid in ceramide, thus giving rise to ω-O-acylceramide, a particular class of sphingolipids that is essential for skin barrier function. The variant was located in the patatin core domain of PNPLA1 and resulted in a truncated protein which could disrupt the function of the protein. This case report highlights a novel compound heterozygous mutation in PNPLA1 identified in a Chinese child.


Assuntos
Humanos , Recém-Nascido , Aciltransferases/genética , Ceramidas/metabolismo , Colódio , Ictiose Lamelar/genética , Lipase/metabolismo , Mutação , Fosfolipases/genética
2.
Journal of Zhejiang University. Science. B ; (12): 343-354, 2019.
Artigo em Inglês | WPRIM | ID: wpr-1010465

RESUMO

Rice stripe virus (RSV) causes dramatic losses in rice production worldwide. In this study, two monoclonal antibodies (MAbs) 16E6 and 11C1 against RSV and a colloidal gold-based immunochromatographic strip were developed for specific, sensitive, and rapid detection of RSV in rice plant and planthopper samples. The MAb 16E6 was conjugated with colloidal gold and the MAb 11C1 was coated on the test line of the nitrocellulose membrane of the test strip. The specificity of the test strip was confirmed by a positive reaction to RSV-infected rice plants and small brown planthopper (SBPH), and negative reactions to five other rice viruses, healthy rice plants, four other vectors of five rice viruses, and non-viruliferous SBPH. Sensitivity analyses showed that the test strip could detect the virus in RSV-infected rice plant tissue crude extracts diluted to 1:20 480 (w/v, g/mL), and in individual viruliferous SBPH homogenate diluted to 1:2560 (individual SPBH/μL). The validity of the developed strip was further confirmed by tests using field-collected rice and SBPH samples. This newly developed test strip is a low-cost, fast, and easy-to-use tool for on-site detection of RSV infection during field epidemiological studies and paddy field surveys, and thus can benefit decision-making for RSV management in the field.


Assuntos
Anticorpos Monoclonais/química , China , Cromatografia de Afinidade/métodos , Colódio/química , Coloides/química , Coloide de Ouro/química , Teste de Materiais , Membranas Artificiais , Oryza/virologia , Doenças das Plantas/virologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Especificidade da Espécie , Tenuivirus/isolamento & purificação
3.
Korean Journal of Dermatology ; : 645-647, 2018.
Artigo em Coreano | WPRIM | ID: wpr-718997

RESUMO

No abstract available.


Assuntos
Colódio
4.
Journal of Veterinary Science ; : 307-316, 2017.
Artigo em Inglês | WPRIM | ID: wpr-57417

RESUMO

A simple and rapid immunochromatographic test strip incorporating a colloidal gold-labeled recombinant Nsp7 antigen probe was successfully developed for the detection of anti-porcine reproductive and respiratory syndrome virus (PRRSV) antibodies in swine. Recombinant Nsp7 protein of PRRSV labeled with colloidal gold was dispensed on a conjugate pad for use as the detector. Staphylococcal protein A and purified porcine anti-Nsp7 antibodies were blotted on a nitrocellulose membrane to form test and control lines, respectively. A comparison of the strip with standard diagnostic tests, enzyme-linked immunosorbent assays and immunoperoxidase monolayer assay, was also performed. The immunochromatographic test strip was shown to be of high specificity and sensitivity. Furthermore, the strip assay is rapid and easy to perform with no requirement for professional-level skills or equipment. It is suggested that the immunochromatographic test strip can be used to quickly and accurately detect PRRSV antibody and to be suitable for diagnostic purposes in the field.


Assuntos
Anticorpos , Colódio , Coloides , Testes Diagnósticos de Rotina , Ensaio de Imunoadsorção Enzimática , Coloide de Ouro , Cromatografia de Afinidade , Membranas , Síndrome Respiratória e Reprodutiva Suína , Vírus da Síndrome Respiratória e Reprodutiva Suína , Sensibilidade e Especificidade , Proteína Estafilocócica A , Suínos
5.
Clinical and Experimental Vaccine Research ; : 61-66, 2017.
Artigo em Inglês | WPRIM | ID: wpr-43943

RESUMO

PURPOSE: Nitrocellulose membrane–based filtration system (NCFS) is widely used for protein concentration. In this study, we applied NCFS for production of virus-like particle (VLP) as a vaccine candidate and evaluated yield property and immunogenicity. MATERIALS AND METHODS: Influenza VLPs were generated by baculovirus-insect cell protein expression system. NCFS and sucrose gradient ultracentrifugation were used for purification of VLP. Immunogenicity of VLP was evaluated by animal experiment. RESULTS: Influenza VLPs expressing hemagglutinin (HA) and neuraminidase proteins derived from highly pathogenic influenza virus (H5N8) were effectively produced and purified by NCFS. HA activity of VLP which correlated with antigenicity was well conserved during multiple purification steps. This NCFS based purified VLPs induced influenza virus–specific antibody responses. CONCLUSION: Our results indicate that the influenza VLP vaccine could be prepared by NCFS without loss of immunogenicity and elicit antigen-specific immune responses.


Assuntos
Experimentação Animal , Formação de Anticorpos , Baculoviridae , Colódio , Filtração , Hemaglutininas , Influenza Humana , Membranas , Neuraminidase , Orthomyxoviridae , Sacarose , Ultracentrifugação , Vacinas
6.
Chinese Journal of Biotechnology ; (12): 1387-1392, 2015.
Artigo em Chinês | WPRIM | ID: wpr-337482

RESUMO

The preservation of urinary proteins on a membrane plays a vital role in biomarker research, and the efficient elution of proteins preserved on nitrocellulose membrane (NC membrane) determines the application of this method. During the heating elution procedure, we raised the temperature to reduce the intense vortexing time, and kept gentle rotating while precipitation to prevent nitrocellulose reformation. We also used SDS-PAGE and LC-MS/MS to analyze the urinary proteins prepared by heating elution procedure, intense vortexing elution procedure and acetone precipitation method. There was no degradation of proteins prepared by heating elution procedure. Compared with proteins prepared by heating elution method and acetone precipitation method, the overlapping rates of the proteins was almost the same (92.6% versus 96.8%) and the ratios of CV values (< 20%) of the proteins were both high (85.2% and 94.4%). The heating elution procedure achieved good technical reproducibility, and was much simpler and more efficient than the previous one. It can facilitate the application of the preservation of urinary proteins on membrane.


Assuntos
Humanos , Acetona , Biomarcadores , Urina , Cromatografia Líquida , Colódio , Eletroforese em Gel de Poliacrilamida , Temperatura Alta , Proteínas , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem , Urina , Química
7.
Chinese Journal of Biotechnology ; (12): 982-989, 2014.
Artigo em Chinês | WPRIM | ID: wpr-279454

RESUMO

Nitrocellulose membrane based urinary protein preservation method is simple, fast and economic, but its advantage over the traditionally used acetone precipitation method is still unclear. In this work, we prepared urinary proteins by the two methods by LC-MS/MS. Then we used protein spectra counts to assess the reproducibility of the two methods. Proteins identified by the two methods were almost the same in number, spectral count distribution and distribution of coefficients of variation value. In conclusion, nitrocellulose membrane method is generally the same as acetone precipitation method. It can be used for large scale preservation of clinical urine samples.


Assuntos
Humanos , Acetona , Cromatografia Líquida , Colódio , Espectrometria de Massas , Proteínas , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem , Urina , Química
8.
The Journal of Advanced Prosthodontics ; : 226-233, 2013.
Artigo em Inglês | WPRIM | ID: wpr-181924

RESUMO

PURPOSE: This study evaluated the adhesion of 10-MDP containing self-etch and self-adhesive resin cements to dentin with and without the use of etch-and-rinse technique. MATERIALS AND METHODS: Human third molars (N=180) were randomly divided into 6 groups (n=30 per group). Conventional (Panavia F2.0, Kuraray-PAN) and self-adhesive resin cements (Clearfil SA, Kuraray-CSA) were bonded to dentin surfaces either after application of 3-step etch-and-rinse (35% H3PO4 + ED Primer) or two-step self-etch adhesive resin (Clearfil SE Bond). Specimens were subjected to shear bond strength test using the universal testing machine (0.5 mm/min). The failure types were analyzed using a stereomicroscope and quality of hybrid layer was observed under a scanning electron microscope. The data (MPa) were analyzed using two-way ANOVA and Tukey's tests (alpha=.05). RESULTS: Overall, PAN adhesive cement showed significantly higher mean bond strength (12.5 +/- 2.3 - 14.1 +/- 2.4 MPa) than CSA cement (9.3 +/- 1.4 - 13.9 +/- 1.9 MPa) (P<.001). Adhesive failures were more frequent in CSA cement groups when used in conjunction with two-step self-adhesive (68%) or no adhesive at all (66%). Hybrid layer quality was inferior in CSA compared to PAN cement in all conditions. CONCLUSION: In clinical situations where bonding to dentin substrate is crucial, both conventional and self-adhesive resin cements based on 10-MDP can benefit from etch-and-rinse technique to achieve better quality of adhesion in the early clinical period.


Assuntos
Humanos , Adesivos , Compostos de Alumínio , Compostos de Cálcio , Quimera , Colódio , Dentina , Elétrons , Dente Serotino , Cimentos de Resina , Compostos de Enxofre
9.
The Journal of Advanced Prosthodontics ; : 241-247, 2013.
Artigo em Inglês | WPRIM | ID: wpr-181922

RESUMO

PURPOSE: To evaluate the effect of various metal oxides on impact strength (IS), fracture toughness (FT), water sorption (WSP) and solubility (WSL) of heat-cured acrylic resin. MATERIALS AND METHODS: Fifty acrylic resin specimens were fabricated for each test and divided into five groups. Group 1 was the control group and Group 2, 3, 4 and 5 (test groups) included a mixture of 1% TiO2 and 1% ZrO2, 2% Al2O3, 2% TiO2, and 2% ZrO2 by volume, respectively. Rectangular unnotched specimens (50 mm x 6.0 mm x 4.0 mm) were fabricated and droptower impact testing machine was used to determine IS. For FT, compact test specimens were fabricated and tests were done with a universal testing machine with a cross-head speed of 5 mm/min. For WSP and WSL, discshaped specimens were fabricated and tests were performed in accordance to ISO 1567. ANOVA and Kruskal-Wallis tests were used for statistical analyses. RESULTS: IS and FT values were significantly higher and WSP and WSL values were significantly lower in test groups than in control group (P<.05). Group 5 had significantly higher IS and FT values and significantly lower WSP values than other groups (P<.05) and provided 40% and 30% increase in IS and FT, respectively, compared to control group. Significantly lower WSL values were detected for Group 2 and 5 (P<.05). CONCLUSION: Modification of heat-cured acrylic resin with metal oxides, especially with ZrO2, may be useful in preventing denture fractures and undesirable physical changes resulting from oral fluids clinically.


Assuntos
Colódio , Bases de Dentadura , Dentaduras , Óxidos , Polímeros , Polimetil Metacrilato , Reforço Psicológico , Solubilidade , Água
10.
The Journal of Advanced Prosthodontics ; : 248-255, 2013.
Artigo em Inglês | WPRIM | ID: wpr-181921

RESUMO

PURPOSE: This study compared the effect of three intraoral repair systems on the bond strength between composite resin and zirconia core. MATERIALS AND METHODS: Thirty zirconia specimens were divided into three groups according to the repair method: Group I- CoJet(TM) Repair System (3M ESPE) [chairside silica coating with 30 microm SiO2 + silanization + adhesive]; Group II- Ceramic Repair System (Ivoclar Vivadent) [etching with 37% phosphoric acid + Zirconia primer + adhesive]; Group III- Signum Zirconia Bond (Heraus) [Signum Zirconia Bond I + Signum Zirconia Bond II]. Composite resin was polymerized on each conditioned specimen. The shear bond strength was tested using a universal testing machine, and fracture sites were examined with FE-SEM. Surface morphology and wettability after surface treatments were examined additionally. The data of bond strengths were statistically analyzed with one-way ANOVA and Tamhane post hoc test (alpha=.05). RESULTS: Increased surface roughness and the highest wettability value were observed in the CoJet sand treated specimens. The specimens treated with 37% phosphoric acid and Signum Zirconia Bond I did not show any improvement of surface irregularity, and the lowest wettability value were found in 37% phosphoric acid treated specimens. There was no significant difference in the bond strengths between Group I (7.80 +/- 0.76 MPa) and III (8.98 +/- 1.39 MPa). Group II (3.21 +/- 0.78 MPa) showed a significant difference from other groups (P<.05). CONCLUSION: The use of Intraoral silica coating system and the application of Signum Zirconia Bond are effective for increasing the bond strength of composite resin to zirconia.


Assuntos
Cerâmica , Colódio , Ácidos Fosfóricos , Polímeros , Dióxido de Silício , Molhabilidade , Zircônio
11.
The Journal of Advanced Prosthodontics ; : 278-286, 2013.
Artigo em Inglês | WPRIM | ID: wpr-181917

RESUMO

PURPOSE: The aim of this study was to determine whether the push-out bond strengths between the radicular dentin and fiber reinforced-composite (FRC) posts with various resin cements decreased or not, according to the coronal, middle or apical level of the root. MATERIALS AND METHODS: FRC posts were cemented with one of five resin cement groups (RelyX Unicem: Uni, Contax with activator & LuxaCore-Dual: LuA, Contax & LuxaCore-Dual: Lu, Panavia F 2.0: PA, Super-Bond C&B: SB) into extracted human mandibular premolars. The roots were sliced into discs at the coronal, middle and apical levels. Push-out bond strength tests were performed with a universal testing machine at a crosshead speed of 0.5 mm/min, and the failure aspect was analyzed. RESULTS: There were no significant differences (P>.05) in the bond strengths of the different resin cements at the coronal level, but there were significant differences in the bond strengths at the middle and apical levels (P.05); all other groups had a significant decrease in bond strength at the middle or apical level (P<.05). The failure aspect was dominantly cohesive at the coronal level of all resin cements (P<.05), whereas it was dominantly adhesive at the apical level. CONCLUSION: All resin cement groups showed decreases in bond strengths at the middle or apical level except LuA and Uni.


Assuntos
Humanos , Adesivos , Dente Pré-Molar , Compostos de Boro , Colódio , Resinas Compostas , Cimentos Dentários , Dentina , Metacrilatos , Metilmetacrilatos , Cimentos de Resina
12.
The Journal of Advanced Prosthodontics ; : 287-295, 2013.
Artigo em Inglês | WPRIM | ID: wpr-181916

RESUMO

PURPOSE: This study investigated the effect of laser parameters and air-abrasion on the peel strength of silicon-based soft denture liner to different denture resins. MATERIALS AND METHODS: Specimens (N=180) were prepared out of three different denture base resins (Rodex, cross-linked denture base acrylic resin; Paladent, heat-cured acrylic resin; Deflex, Polyamide resin) (75 mm x 25 mm x 3 mm). A silicon-based soft denture liner (Molloplast B) was applied to the denture resins after the following conditioning methods: a) Air-abrasion (50 microm), b) Er,Cr:YSGG laser (Waterlase MD Turbo, Biolase Technology) at 2 W-20 Hz, c) Er,Cr:YSGG laser at 2 W-30 Hz, d) Er,Cr:YSGG laser at 3 W-20 Hz, e) Er,Cr:YSGG laser at 3 W-30 Hz. Non-conditioned group acted as the control group. Peel test was performed in a universal testing machine. Failure modes were evaluated visually. Data were analyzed using two-way ANOVA and Tukey's test (alpha=.05). RESULTS: Denture liner tested showed increased peel strength after laser treatment with different parameters (3.9+/-0.4 - 5.58+/-0.6 MPa) compared to the control (3.64+/-0.5 - 4.58+/-0.5 MPa) and air-abraded groups (3.1+/-0.6 - 4.46+/-0.3 MPa), but the results were not statistically significant except for Paladent, with the pretreatment of Er,Cr:YSGG laser at 3 W-20 Hz. Polyamide resin after air-abrasion showed significantly lower peel strength than those of other groups (3.1+/-0.6 MPa). CONCLUSION: Heat-cured acrylic resin, PMMA, may benefit from Er,Cr:YSGG laser treatment at 3 W-20 Hz irradiation. Air-abrasion of polyamide resins should be avoided not to impair their peel bond strengths to silicon-based soft denture liners.


Assuntos
Colódio , Bases de Dentadura , Reembasadores de Dentadura , Dentaduras , Nylons , Polimetil Metacrilato
13.
The Korean Journal of Orthodontics ; : 235-241, 2013.
Artigo em Inglês | WPRIM | ID: wpr-213118

RESUMO

OBJECTIVE: The purpose of this study was to investigate whether extension of the custom base is necessary for enhancement of bond strength, by comparing the debonding forces and residual adhesives of 3 different lingual bracket systems. METHODS: A total of 42 extracted upper premolars were randomly divided into 3 groups of 14 each for bonding with brackets having (1) a conventional limited resin custom base; (2) an extended gold alloy custom base: Incognito(TM); and (3) an extended resin custom base: KommonBase(TM). The bonding area was measured by scanning the bracket bases with a 3-dimensional digital scanner. The debonding force was measured with an Instron universal testing machine, which applied an occlusogingival shear force. RESULTS: The mean debonding forces were 60.83 N (standard deviation [SD] 10.12), 69.29 N (SD 9.59), and 104.35 N (SD17.84) for the limited resin custom base, extended gold alloy custom base, and extended resin custom base, respectively. The debonding force observed with the extended resin custom base was significantly different from that observed with the other bases. In addition, the adhesive remnant index was significantly higher with the extended gold alloy custom base. CONCLUSIONS: All 3 custom-base lingual brackets can withstand occlusal and orthodontic forces. We conclude that effective bonding of lingual brackets can be obtained without extension of the custom base.


Assuntos
Adesivos , Ligas , Dente Pré-Molar , Colódio , Colagem Dentária , Braquetes Ortodônticos
14.
The Journal of Advanced Prosthodontics ; : 382-387, 2013.
Artigo em Inglês | WPRIM | ID: wpr-159882

RESUMO

PURPOSE: Although several surface treatments have been recently investigated both under in vitro and in vivo conditions, controversy still exists regarding the selection of the most appropriate zirconia surface pre-treatment. The purpose of this study was to evaluate the effect of alumina (Al) and aluminium nitride (AlN) coating on the shear bond strength of adhesive resin cement to zirconia core. MATERIALS AND METHODS: Fifty zirconia core discs were divided into 5 groups; air particle abrasion with 50 microm aluminum oxide particles (Al2O3), polishing + Al coating, polishing + AlN coating, air particle abrasion with 50 microm Al2O3 + Al coating and air particle abrasion with 50 microm Al2O3 + AlN coating. Composite resin discs were cemented to each of specimens. Shear bond strength (MPa) was measured using a universal testing machine. The effects of the surface preparations on each specimen were examined with scanning electron microscope (SEM). Data were statistically analyzed by one-way ANOVA (alpha=.05). RESULTS: The highest bond strengths were obtained by air abrasion with 50 microm Al2O3, the lowest bond strengths were obtained in polishing + Al coating group (P<.05). CONCLUSION: Al and AlN coatings using the reactive magnetron sputtering technique were found to be ineffective to increase the bond strength of adhesive resin cement to zirconia core.


Assuntos
Adesivos , Óxido de Alumínio , Colódio , Cimentos de Resina , Zircônio
15.
Asian Spine Journal ; : 63-71, 2013.
Artigo em Inglês | WPRIM | ID: wpr-172140

RESUMO

Patient safety regarding wrong site surgery has been one of the priority issues in surgical fields including that of spine care. Since the wrong-side surgery in the DM foot patient was reported on a public mass media in 1996, the wrong-site surgery issue has attracted wide public interest as regarding patient safety. Despite the many wrong-site surgery prevention campaigns in spine care such as the operate through your initial program by the Canadian Orthopaedic Association, the sign your site program by the American Academy of Orthopedic Surgeon, the sign, mark and X-ray program by the North American Spine Society, and the Universal Protocol program by the Joint Commission, the incidence of wrong-site surgery has not decreased. To prevent wrong-site surgery in spine surgeries, the spine surgeons must put patient safety first, complying with the hospital policies regarding patient safety. In the operating rooms, the surgeons need to do their best to level the hierarchy, enabling all to speak up if any patient safety concerns are noted. Changing the operating room culture is the essential part of the patient safety concerning spine surgery.


Assuntos
Humanos , Colódio , , Incidência , Articulações , Meios de Comunicação de Massa , Salas Cirúrgicas , Ortopedia , Segurança do Paciente , Coluna Vertebral
16.
The Korean Journal of Orthodontics ; : 96-100, 2013.
Artigo em Inglês | WPRIM | ID: wpr-143928

RESUMO

OBJECTIVE: To evaluate the effects of contamination by either blood or a hemostatic agent on the shear bond strength (SBS) of orthodontic buttons. METHODS: We used 45 freshly extracted, non-carious, impacted third molars that were divided into 3 groups of 15. Each tooth was etched with 37% phosphoric acid gel for 30 s. Human blood or the blood stopper agent was applied to the tooth surface in groups I and II, respectively. Group III teeth were untreated (controls). Orthodontic buttons were bonded to the teeth using light-curing composite resin. After bonding, the SBS of the button was determined using a Universal testing machine. Any adhesive remaining after debonding was assessed and scored according to the modified adhesive remnant index (ARI). ANOVA with post-hoc Tukey's test was used to determine significant differences in SBS and Fisher's exact test, to determine significant differences in ARI scores among groups. RESULTS: ANOVA indicated a significant difference between groups (p < 0.001). The highest SBS values were measured in group III (10.73 +/- 0.96 MPa). The SBS values for teeth in groups I and II were significantly lower than that of group III (p < 0.001). The lowest SBS values were observed in group I teeth (4.17 +/- 1.11 MPa) (p < 0.001). CONCLUSIONS: Contamination of tooth surfaces with either blood or hemostatic agent significantly decreased the SBS of orthodontic buttons. When the contamination risk is high, it is recommended to use the blood stopper agent when bonding orthodontic buttons on impacted teeth.


Assuntos
Humanos , Adesivos , Colódio , Dente Serotino , Ácidos Fosfóricos , Dente , Dente Impactado
17.
The Korean Journal of Orthodontics ; : 96-100, 2013.
Artigo em Inglês | WPRIM | ID: wpr-143921

RESUMO

OBJECTIVE: To evaluate the effects of contamination by either blood or a hemostatic agent on the shear bond strength (SBS) of orthodontic buttons. METHODS: We used 45 freshly extracted, non-carious, impacted third molars that were divided into 3 groups of 15. Each tooth was etched with 37% phosphoric acid gel for 30 s. Human blood or the blood stopper agent was applied to the tooth surface in groups I and II, respectively. Group III teeth were untreated (controls). Orthodontic buttons were bonded to the teeth using light-curing composite resin. After bonding, the SBS of the button was determined using a Universal testing machine. Any adhesive remaining after debonding was assessed and scored according to the modified adhesive remnant index (ARI). ANOVA with post-hoc Tukey's test was used to determine significant differences in SBS and Fisher's exact test, to determine significant differences in ARI scores among groups. RESULTS: ANOVA indicated a significant difference between groups (p < 0.001). The highest SBS values were measured in group III (10.73 +/- 0.96 MPa). The SBS values for teeth in groups I and II were significantly lower than that of group III (p < 0.001). The lowest SBS values were observed in group I teeth (4.17 +/- 1.11 MPa) (p < 0.001). CONCLUSIONS: Contamination of tooth surfaces with either blood or hemostatic agent significantly decreased the SBS of orthodontic buttons. When the contamination risk is high, it is recommended to use the blood stopper agent when bonding orthodontic buttons on impacted teeth.


Assuntos
Humanos , Adesivos , Colódio , Dente Serotino , Ácidos Fosfóricos , Dente , Dente Impactado
18.
The Journal of Korean Academy of Prosthodontics ; : 160-166, 2013.
Artigo em Coreano | WPRIM | ID: wpr-225952

RESUMO

PURPOSE: The purpose of this study was to compare the fracture strength of traditional metal-ceramic crowns and full zirconia crowns according to the occlusal thickness. MATERIALS AND METHODS: A mandibular first molar resin tooth was prepared with 1.5 mm occlusal reduction, 1.0 mm rounded shoulder margin and 6degrees taperness in the axial wall. Duplicating the resin tooth, 64 metal dies were fabricated. 48 full zirconia crowns were fabricated using Prettau zirconia blanks by ZIRKONZAHN CAD/CAM and classified into six groups according to the occlusal thickness (0.5 mm, 0.6 mm, 0.7 mm, 0.8 mm, 0.9 mm, 1.0 mm). 16 metal-ceramic crowns were fabricated and classified into two groups according to the occlusal porcelain thickness (1.0 mm, 1.5 mm). All crowns were cemented on each metal die and mounted in a universal testing machine. The load was directed at the functional cusp of each specimen until catastrophic failure occurred. One-way ANOVA, Tukey multiple comparison test (alpha=.05) and t-test (alpha=.05) were used. RESULTS: The results were as follows. 1. The test 1 group (646.48 N) showed the lowest fracture strength (P.05). The value of test 6 group (1781.24 N) was significantly higher than those of the other groups (P<.05). 2. There were no significant differences of the fracture strength of metal ceramic crowns according to occlusal porcelain thickness 1.0 mm (2515.71 N) and 1.5 mm (3473.31 N) (P<.05). CONCLUSION: Full zirconia crown needs to be 1.0 mm or over in occlusal thickness for the posterior area to have higher fracture strength than maximum bite force.


Assuntos
Força de Mordida , Cerâmica , Colódio , Coroas , Porcelana Dentária , Dente Molar , Ombro , Dente , Zircônio
19.
Journal of the Korean Surgical Society ; : 298-303, 2013.
Artigo em Inglês | WPRIM | ID: wpr-169026

RESUMO

PURPOSE: Venous thromboembolism (VTE) after bariatric surgery is a significant cause of morbidity and mortality. Current modalities of thromboprophylaxis include subcutaneous injection of unfractionated or low-molecular-weight heparin (LMWH), pneumatic compression, elastic stockings, and inferior vena cava filters. Despite universal agreement on the need for thromboprophylaxis, no clear consensus has been reached regarding the best regimen and treatment duration of bariatric surgery. METHODS: From April, 2009 to December, 2011, we performed 200 bariatric surgery (191 with primary intent, 9 with revisional intent). There was no history of VTE prior to surgery. Clexane therapy was done with 4000 U SQ once daily for 2 weeks to the day before surgery. Development of VTE was assessed by direct interview, physical examination in out-patient clinic, and phone calls to patients for history taking if needed. The history taking was presented in questionnaire format. The patients were asked to state their symptoms of VTE by answering the questionnaire. The patients were followed up for a minimum of 6 months after surgery to determine the incidence of clinical VTE. RESULTS: Two-week Clexane therapy was completed in 193 patients. Clexane was stopped in 5 due to surgical related complications (4 bleeding, 1 reoperation due to leak), in 2 due to Clexane related complications (1 epistaxis, 1 metrorrhagia). Follow-up of out-patient clinic were 68%, those who could follow up by telephone were 89%. There was no evidence of VTE. CONCLUSION: A 2-week VTE prophylaxis regimen using LMWH is simple, effective and associated with a low incidence of complications.


Assuntos
Humanos , Cirurgia Bariátrica , Colódio , Consenso , Enoxaparina , Epistaxe , Seguimentos , Hemorragia , Heparina de Baixo Peso Molecular , Incidência , Injeções Subcutâneas , Pacientes Ambulatoriais , Exame Físico , Inquéritos e Questionários , Reoperação , Meias de Compressão , Telefone , Filtros de Veia Cava , Tromboembolia Venosa
20.
The Journal of Korean Academy of Prosthodontics ; : 20-26, 2013.
Artigo em Coreano | WPRIM | ID: wpr-87091

RESUMO

PURPOSE: The purpose of this study was to evaluate the bond strengths between the latest CAD/CAM ceramic inlay and various resin cements which are used primarily for esthetic restoration. MATERIALS AND METHODS: Cylindrical ceramic blocks(Height: 5 mm, diameter: 3 mm) were fabricated by using Cerec3 and bonded on the dentin of the ninety extracted caries-free molars using three different kinds of resin cement(Unicem(R), Biscem(R), and Variolink II(R)) according to the manufacturer's instructions. Ninety specimens were divided into 3 groups according to three different kinds of resin cement. Half of each group were conducted thermocycling under the conditions of the 5 - 55degrees C, 5,000 cycle but the other half of them weren't. All specimens were kept in normal saline 37degrees C, for 24 hours before measuring the bond strength. The shear bond strength was measured by Universal testing machine with a cross head speed of 0.5 mm/min. The results were analyzed statistically by t-test and one-way ANOVA. RESULTS: Unicem(R) group showed the highest shear bond strength despite a slight decline by thermocycling. The shear bond strength of Unicem(R) group and ValiolinkII(R) group were significantly influenced by thermocycling, whereas Biscem(R) group was not influenced (P<.05). There were no significant differences in the bond strength between the three groups without thermocycling, but there was significant differences between Unicem(R) group and Valiolink II(R) group with thermocycling(P<.05). CONCLUSION: It has been shown to be clinically effective when the self-adhesive resin cements Unicem(R) and Biscem(R) were used instead of the etch-and-rinse resin cement Valiolink II(R) during the bonding of CAD/CAM ceramic inlay restorations with teeth.


Assuntos
Cerâmica , Colódio , Dentina , Cabeça , Restaurações Intracoronárias , Dente Molar , Cimentos de Resina , Dente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA