Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Adicionar filtros








Intervalo de ano
1.
Rev. chil. tecnol. méd ; 30(2): 1589-1594, dic. 2010. tab
Artigo em Espanhol | LILACS | ID: lil-583085

RESUMO

Determinar criterios de evaluación morfológica del hemograma, basados en parámetros clínicos y resultados del contador hematológico, en términos de gestión, costos y clínica en un hospital tipo 1. Pacientes, materiales y métodos: muestras de hemogramas de pacientes del hospital de carabineros de Chile durante el mes de agosto de 2009, analizadas en un equipo HMX Beckman-Coulter y evaluadas morfológicamente por Tecnólogo Médico(TM). Se registraron parámetros clínicos como hemoglobina, leucocitos y plaquetas; además se consideró el lugar de derivación, especialidad y edad del paciente. Se determinaron los costos e ingresos en función de los resultados obtenidos. Resultados: de los 2.222 pacientes evaluados, existió concordancia entre el Tecnólogo Médico y el analizador en 93,3 por ciento de los casos, con una sensibilidad de 97,3 por ciento y una especificidad de 88,9 por ciento con valores predictivos positivo y negativo de 95,9 por ciento y 92,7 por ciento respectivamente, para detectar una muestra anormal. Con los criterios de selección fue posible eliminar la evaluación morfológca en 79,5 por ciento de los casos, permitiendo un ahorro de $3655929 en el mes por concepto de hemogramas. Discusión: el estudio demostró que es posible disminuir el número de evaluaciones morfológicas realizadas al hemograma a valores similares obtenidos en estudios internacionales, con reducción significativa de los costos y tiempos de TM.


Objective: to determine criteria for the morphological analysis of the full blood count, based on the clinical parameters and the results of the full blood count using an automatic counter in terms of cost and clinicla implications in a distric hospital. Patients, Materials and Method: Full blood count samples from patients attended in the Hospital de Carabineros de Chile during the month of August 2009 were analyzed using HmX Beckman-Coulter and evaluated morpholigically by the Medical Science Officer(Medical Technologist). Clinical parameters, hemoglobin, white cell count platete count were registered, as well the origin of the specimen, medical speciality an patient age. The cost an income derived from the full blood count were determined by the Unit of Cost, Hospital of Carabineros and the changes in costs calculated in function of the results obtained. Results: Of the 2,222 patients evaluated, there was a concordance between the Clinical Science Officer(Medical Technologist) and the automatic counter in 93,9 percent of the samples, with a sensitivity of 97,3 percent and a specificy of 88,9 percent, a positive and negative predictive evalues of 95,9 percent and 92,7 percent respectively for detecting an abnormal sample. Using the criteria of selection it was possible to eliminate the evaluation morphological in 79,5 percent of the samples permitting a saving of $3655929 per month for the analysis of full morphological evaluations of the blood count without losing clinically important data in 80 percent of the samples, which is similar to that reported internationally, with a significant decrease in cost an Medical Scientific Officer time.


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Lactente , Pré-Escolar , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Análise Custo-Benefício , Gestão em Saúde , Laboratórios Hospitalares/economia , Laboratórios Hospitalares/organização & administração , Controle de Qualidade , Contagem de Células Sanguíneas/economia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA