Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
7.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 23(2): 67-74, abr.-jun. 2010. tab, graf
Artigo em Português | LILACS | ID: lil-559908

RESUMO

O ICD Register da Medtronic foi introduzido na América Latina com a finalidade de coletar dados relacionados à indicação de implantes de CDI para prevenção primária e secundária de morte súbita e ao acompanhamento de pacientes originários de Porto Rico, Caribe. México e América do Sul. Além dessa ampla variedade geográfica, também foram incluídos detalhes referentes aos cuidados de saúde recebidos como parte do tratamento. O presente estudo apresenta as características de desfecho de 910 portadores de cardiopatias tratados para prevenção primária, em comparação com aqueles nos quais o implante destinou-se à prevenção secundária.


The ICD Register was introduced to Latin America to collect data related to implant indication of ICD for the prevention of primary and secondary deaths and for the follow-up of patients from Puerto Rico, the Caribbean, Mexico and South America. In addition to this vast geographic variety, information related to the health care as part of the treatment has also been included. This study shows the characteristics of the outcome of 910 cardiopathy patients treated for primary prevention, incomparison to those whose implants were meant for secondary prevention.


El ICD Register de Medtronic fue introducido en América Latina a fin de recoger datos relacionados a la indicación de implantes de CDI para la prevención primaria y secundaria de muerte súbita y a la remisión de pacientes provenientes de Puerto Rico, Caribe, México y Sudamérica. Ademásde esa amplia variedad geográfica, también se incluyeron detalles referentes a los cuidados de saludrecibidos como parte del tratamiento. El presente estudio presenta las características de solución de 910 portadores de cardiopatías tratados para la prevención primaria, en comparación con aquellos cuyo implante se destinó a la prevención secundaria.


Assuntos
Humanos , Adulto , Idoso , Cardiopatias/terapia , Morte Súbita , Desfibriladores Implantáveis/normas , Estudos Multicêntricos como Assunto/classificação , Prevenção Primária/normas , Prevenção Secundária/normas
10.
Arq. bras. cardiol ; 90(3): 177-184, mar. 2008. ilus, graf, tab
Artigo em Inglês, Português | LILACS | ID: lil-479618

RESUMO

FUNDAMENTO: A programação ideal da energia de choque do CDI deve ser pelo menos 10 J acima do limiar de desfibrilação (LDF), necessitando de técnicas alternativas quando o LDF é elevado. OBJETIVO: Avaliar o comportamento clínico dos portadores de CDI com LDF>25 J e a eficácia da terapêutica escolhida. MÉTODOS: Foram selecionados portadores de CDI, entre janeiro de 2000 e agosto de 2004 (banco de dados prospectivo), com LDF>25 J intra-operatório, e analisaram-se: características clínicas, FEVE, resgate de eventos arrítmicos pelo CDI e óbitos. RESULTADOS: dentre 476 pacientes, 16 (3,36 por cento) apresentaram LDF>25J. Idade média de 56,5 anos, sendo 13 pacientes (81 por cento) do sexo masculino. Quanto à cardiopatia de base 09 eram chagásicos, 04 isquêmicos e 03 com etiologia idiopática. A FEVE média dos pacientes foi 37 por cento e 94 por cento utilizavam amiodarona. O seguimento médio foi de 25,3 meses. Em 02 pacientes com LDF > Choque Máximo (CM), foi necessário implante de eletrodo de choque adicional (array), sendo mantido programação com CM em zona de FV (>182bpm) nos demais. Durante o seguimento 03 pacientes apresentaram 67 terapias de choque apropriadas (TCA) com sucesso. Ocorreram 07 óbitos sendo 5 por causas não cardíacas e 2 por insuficiência cardíaca avançada. Os pacientes que foram a óbito apresentaram níveis de LDF maiores (p=0,0446), entretanto sem relação com a causa dos mesmos tendo em vista que não ocorreram TCA sem sucesso. CONCLUSÃO: Nessa coorte de pacientes com CDI, a ocorrência de LDF elevado foi baixa, implicando terapêuticas alternativas. Houve associação com disfunção ventricular grave, entretanto sem correlação com as causas de óbito.


BACKGROUND: The ideal programming of the implantable cardioverter defibrillator (ICD) shock energy should be at least 10J above the defibrillation threshold (DFT), requiring alternative techniques when the DFT is elevated. OBJECTIVE: To assess the clinical behavior of ICD patients with DFT>25J and the efficacy of the chosen therapy. METHODS: Patients who had undergone ICD implantation between Jan/00 and Aug/04 (prospective database) and presented intraoperative DFT>25J were selected. The analyzed variables were: clinical characteristics, LVEF, rescue of arrhythmic events from ICD and causes of deaths. RESULTS: among 476 patients, 16 (3.36 percent) presented DFT>25J. The mean age was 56.5 years, and 13 patients (81 percent) were men. According to the baseline cardiomyopathy, 09 patients had Chagas' disease, 04 had ischemic cardiomyopathy and 03 had idiopathic cardiomyopathy. Mean LVEF was 0.37 and amiodarone was used by 94 percent of the patients. Mean follow-up (FU) period was 25.3 months. DFT was higher than maximum energy shock (MES) in 2 patients and it was necessary to implant an additional shock electrode (array). It was programmed MES in ventricular fibrillation zone of ICD therapy in the other patients. In the FU, 03 patients had 67 successful appropriate shock therapies (AST). There were 05 noncardiac and 02 heart failure deaths. The patients who died showed higher DFT levels (p=0.044) without correlation with death because there wasn't unsuccessful AST. CONCLUSION: In this cohort of ICD patients, the occurrence of elevated DFT (>25J) was low, leading to alternative therapies. There was an association with severe ventricular dysfunction, although without correlation to the causes of death.


Assuntos
Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Cardioversão Elétrica , Amiodarona/uso terapêutico , Antiarrítmicos/uso terapêutico , Arritmias Cardíacas/tratamento farmacológico , Arritmias Cardíacas/mortalidade , Limiar Diferencial , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/normas , Técnicas Eletrofisiológicas Cardíacas , Cardioversão Elétrica/normas , Seguimentos , Estudos Prospectivos , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia
12.
In. Melo, Celso Salgado de; Greco, Oswaldo Tadeu; Mateos, José Carlos Pachón. Temas de marcapasso. São Paulo, Lemos, 2; 2004. p.353-363, ilus.
Monografia em Português | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1069612
13.
Rev. bras. eng. biomed ; 17(1): 03-12, jan.-abr. 2001. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-358868

RESUMO

Este artigo descreve um sistema de baixo custo desenvolvido para realizar análise de desfibriladores cardíacos, cardioversores e esfigmomanômetros. O sistema é composto de dois módulos externos (que realizam o condicionamento do sinal dos equipamentos sob teste) e de um módulo interno que é inserido no barramento ISA de um microcomputador IBM-PC ou compatível. O módulo interno é responsável pela digitalização da forma de onda gerada pelo equipamento sob teste. Esta forma de onda é então transmitida as microcomputador, que processa e calcula os parâmetros para caracterizar o desempenha dos equipamentos sob teste. Os parâmetros calculados para o desfibrilador são: energia liberada, pico de corrente, pico de tensão e a duração do pulso. Para o cardioversor, além dos parâmetros citados, calcula-se ainda o intervalo de tempo entre a ocorrência da onda R do ECG e o pulso desfibrilatório (tempo de sincronismo). Os parâmetros calculados, juntamento com a forma de onda amostrada são apresentados na tela do microcomputador e podem ser armazenados em um arquivo texto. Para o esfigmomanômetro, calcula-se a pressão média, o erro sistemático e o desvio padrão da medida do manômetro. Exemplos de ensaios realizados com este sistema são apresentados. Os resultados dos ensaios foram comparados com os obtidos por sistemas comerciais. Estas comparações mostraram que o sistema realiza as medições com a exatidão adequada ao propósito.


Assuntos
Processamento de Sinais Assistido por Computador , Esfigmomanômetros , Análise Numérica Assistida por Computador/instrumentação , Cardioversão Elétrica/normas , Desfibriladores Implantáveis/normas , Calibragem , Manutenção Preventiva
17.
In. Santelices Cuevas, Emilio. Cuidados postoperatorios y paciente quirúrgico crítico. Santiago de Chile, Sociedad de Cirujanos de Chile, nov. 1994. p.264-8.
Monografia em Espanhol | LILACS | ID: lil-173038
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA