Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Braz. oral res. (Online) ; 30(1): e137, 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-951974

RESUMO

Abstract: To analyse the changes of surface characteristics of machined and moderately roughened titanium disks following a standardised implantoplasty protocol. Forty titanium discs (machined: n = 20; moderately roughened: n = 20) were instrumented with one half of each disc maintained as the control (non-instrumented). The standardised implantoplasty protocol was carried out using a custom jig with the sequential change of burs: 1) Regular grit diamond [10s], 2) Super-fine grit diamond [10s], 3) Brownie(tm) silicone polisher [15s], 4) Greenie(tm) silicone polisher [15s]. Surface topography was analysed using confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). Energy dispersive x-ray spectroscopy (EDS) was used to measure the elemental profiles of each disc. Quantitative analysis showed similar changes in level of roughness between the machined and moderately roughened titanium discs. CLSM demonstrated an increased roughness (Ra and Sa values) after polishing with a regular grit diamond bur when compared to the uninstrumented surfaces. Although the roughness decreased after the further polishing with the super-fine grit diamond bur, subsequent instrumentation using silicon burs tended to increase the roughness, albeit being statistically insignificant. There was a residue of silicon particles despite the irrigation after each polishing stage. The proposed implantoplasty protocol did not achieve a sufficient level of smoothness on the machined or moderately roughened titanium surfaces when compared to the Ra threshold. Further research is recommended to test the efficacy of each bur on titanium surfaces with longer duration using actual oral implants to allow better comparison.


Assuntos
Titânio/química , Polimento Dentário/métodos , Valores de Referência , Espectrometria por Raios X , Propriedades de Superfície , Teste de Materiais , Microscopia Eletrônica de Varredura , Diamante/química , Estatísticas não Paramétricas , Microscopia Confocal
2.
Braz. oral res. (Online) ; 30(1): e12, 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-768252

RESUMO

Abstract The present study investigated the effect of grinding on roughness, flexural strength, and reliability of a zirconia ceramic before and after heat treatment. Seven groups were tested (n = 15): a control group (labeled CG, untreated), and six groups of samples ground with diamond discs, simulating diamond burs, with grits of 200 µm (G80); 160 µm (G120), and 25 µm (G600), either untreated or heat-treated at 1200°C for 2 h (labeled A). Yttria tetragonal zirconia polycrystal discs were manufactured, ground, and submitted to roughness and crystalline phase analyses before the biaxial flexural strength test. There was no correlation between roughness (Ra and Rz) and flexural strength. The reliability of the materials was not affected by grinding or heat treatment, but the characteristic strength was higher after abrasion with diamond discs, irrespective of grit size. The X-ray diffraction data showed that grinding leads to a higher monoclinic (m) phase content, whereas heat treatment produces reverse transformation, leading to a fraction of m-phase in ground samples similar to that observed in the control group. However, after heat treatment, only the G80A samples presented strength similar to that of the control group, while the other groups showed higher strength values. When zirconia pieces must be adjusted for clinical use, a smoother surface can be obtained by employing finer-grit diamond burs. Moreover, when the amount of monoclinic phase is related to the degradation of zirconia, the laboratory heat treatment of ground pieces is indicated for the reverse transformation of zirconia crystals.


Assuntos
Cerâmica/química , Temperatura Alta , Zircônio/química , Diamante/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Maleabilidade , Reprodutibilidade dos Testes , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo , Difração de Raios X , Ítrio/química
3.
Dental press j. orthod. (Impr.) ; 18(6): 45-50, Nov.-Dec. 2013. ilus, tab
Artigo em Inglês | LILACS | ID: lil-697730

RESUMO

OBJECTIVE: The aim of the present study was to assess the influence of saliva contamination over the structural strength and integrity of conventional glass-ionomer cements used for cementing orthodontic bands in the absence and presence of a surface-protecting varnish. METHOD: 48 samples were prepared by inserting 3 types of glass-ionomer cements into standardized metallic matrixes of 10 mm of diameter and 2 mm of depth. The cements used were: Meron (VOCO), Ketac-Cem (3M ESPE) and Vidrion C (DFL), all of which comprised groups A, B and C, respectively. Subgroups A1, B1 and C1 comprised samples with no surface protection, whereas subgroups A2, B2 and C2 comprised samples of which surface was coated with Cavitine varnish (SS White), after cement manipulation and application, in order to protect the cement applied. All samples were stored in artificial saliva for 24 hours at 37ºC. A Vickers diamond micro-durometer was used to produce indentations on the non-treated group (non-varnished) and the treated group (varnished). RESULTS: Varnished materials had significantly higher microhardness values in comparison to non-varnished materials. Ketac-Cem had the highest microhardness value among the varnished materials. CONCLUSION: Varnish application is necessary to preserve the cement and avoid enamel decalcification. Glass-ionomer cements should be protected in order to fully keep their properties, thus, contributing to dental health during orthodontic treatment.


OBJETIVO: avaliar a influência da contaminação salivar na resistência estrutural e integridade de cimentos de ionômero de vidro convencionais utilizados para cimentação de bandas ortodônticas na ausência e na presença de um verniz protetor de superfície. MÉTODOS: quarenta e oito corpos de prova foram confeccionados a partir de três cimentos ortodônticos, com auxílio de matrizes metálicas padronizadas com 10mm de diâmetro e 2mm de altura. Os cimentos utilizados foram: Meron (Voco), Ketac-Cem (3M ESPE) e Vidrion C (DFL), compondo os grupos A, B e C, respectivamente. Metade dessas amostras não recebeu nenhum tipo de proteção superficial, constituindo os subgrupos A1, B1 e C1, enquanto, os subgrupos A2, B2 e C2 tiveram suas superfícies isoladas com verniz Cavitine (SS White) após manipulação e aplicação do cimento, com intuito de proteger a superfície do cimento. As amostras foram armazenadas em saliva artificial por 24 horas a 37ºC. Foi realizado um ensaio de microdureza (Vickers) para avaliação da dureza de superfície do grupo não-tratado (sem isolamento) e do grupo tratado (agente protetor). RESULTADOS: os materiais previamente isolados com o verniz obtiveram valores de microdureza significativamente maiores que os não-isolados. O cimento Ketac-Cem apresentou, estatisticamente, a maior microdureza entre os materiais protegidos. CONCLUSÃO: o isolamento com verniz mostrou-se necessário para preservação do cimento e, consequentemente, de sua capacidade de evitar possíveis desmineralizações dentárias. Os cimentos de ionômero de vidro devem ser protegidos para manutenção de sua integridade, contribuindo para saúde dental durante o tratamento ortodôntico.


Assuntos
Humanos , Cimentos de Ionômeros de Vidro/química , Braquetes Ortodônticos , Substâncias Protetoras/química , Diamante/química , Contaminação de Equipamentos , Dureza , Teste de Materiais , Óxido de Magnésio/química , Cimento de Policarboxilato/química , Estresse Mecânico , Propriedades de Superfície , Saliva Artificial/química , Temperatura , Fatores de Tempo , Óxido de Zinco/química
4.
Braz. dent. j ; 24(2): 107-110, Mar-Apr/2013. graf
Artigo em Inglês | LILACS | ID: lil-675667

RESUMO

Despite the excellent properties of mineral trioxide aggregate (MTA), the condensation technique may have some influence in its sealing ability. The purpose of this study was to compare the sealing ability of sonic and ultrasonic setting of MTA. Thirty-four extracted human teeth had their canals prepared and filled with Sealapex sealer and gutta-percha using the active lateral condensation technique. The teeth were rendered waterproof and apicoectomy performed at 3 mm from the apex. Root-end cavities (3.0 mm deep and 1.4 mm diameter) were prepared with diamond ultrasonic tips. The root-end cavities were filled with Pro-Root MTA® with ultrasonic vibration, sonic vibration or no vibration. The positive control group did not receive any material while the negative control group was totally rendered waterproof. After material set, the specimens were immersed in Rodhamine B for 24 h, under vacuum in the first 15 min, then washed, dried and split longitudinally for evaluating the infiltration at the dentin/material interface. Data were analyzed using ANOVA and Tukey's tests at 5% significance level. Sonic vibration promoted the lowest infiltration values (p<0.05). It was concluded that sonic vibration could be considered an efficient aid to improve the sealing ability of MTA when used as root-end filling material.


Resumo O objetivo deste estudo foi avaliar in vitro, a influência da vibração sônica e ultrassônica no selamento marginal proporcionado pelo MTA. Trinta e quatro dentes humanos tiveram seus canais radiculares instrumentados e obturados com cimento Sealapex® pela técnica da condensação lateral ativa. Os dentes foram impermeabilizados e seccionados os 3 mm apicais. Retrocavidades (3 mm de profundidade e 1,4 mm de diâmetro) foram preparadas com pontas ultrassônicas diamantadas. As retrocavidades foram preenchidas com Pro-Root MTA® com auxílio da vibração ultrassônica, com auxílio da vibração sônica e sem vibração alguma. O grupo controle positivo não recebeu material retrobturador, enquanto que o negativo foi totalmente impermeabilizado. Após a presa do material, os espécimes foram mergulhados em Rodamina B por 15 min em vácuo, permanecendo nesta solução por mais 24 h. Em seguida, foram lavados, secados e clivados longitudinalmente para avaliação da infiltração do corante na interface dentina/material retrobturador. Os dados foram analisados utilizando a análise de variância e o teste de Tukey (p<0,05). Observou-se que apenas a vibração sônica foi diferente apresentando os menores índices de infiltração. Pode-se concluir que vibração sônica contribui com a melhora da capacidade de selamento marginal proporcionado pelo MTA quando empregado como material retrobturador. .


Assuntos
Humanos , Compostos de Alumínio/uso terapêutico , Compostos de Cálcio/uso terapêutico , Colagem Dentária , Óxidos/uso terapêutico , Obturação Retrógrada/métodos , Materiais Restauradores do Canal Radicular/uso terapêutico , Silicatos/uso terapêutico , Apicectomia/métodos , Hidróxido de Cálcio/uso terapêutico , Combinação de Medicamentos , Dentina/ultraestrutura , Diamante/química , Corantes Fluorescentes , Guta-Percha/uso terapêutico , Rodaminas , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Sonicação , Propriedades de Superfície , Salicilatos/uso terapêutico , Fatores de Tempo , Ultrassom/instrumentação , Vibração
5.
J. appl. oral sci ; 18(1): 10-16, Jan.-Feb. 2010. ilus, tab
Artigo em Inglês | LILACS | ID: lil-545021

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the effects of different polishing techniques on the surface roughness of dental porcelains. MATERIAL AND METHODS: Fifty-five cylindirical specimens (15x2 mm) were prepared for each feldspathic (Vita VMK 95, Ceramco III) and low-fusing dental porcelain (Matchmaker). Fifty-five specimens of machinable feldspathic porcelain blocks (Vitablocs Mark II), (12x14x18 mm) were cut into 2-mm-thick slices (12x14 mm) with low speed saw. The prepared specimens were divided into 11 groups (n=5) representing different polishing techniques including control ((C) no surface treatment), glaze (G) and other 9 groups that were finished and polished with polishing discs (Sof-Lex) (Sl), two porcelain polishing kits (NTI (Pk), Dialite II (Di)), a diamond polishing paste (Sparkle) (Sp), a zirconium silicate based cleaning and polishing prophy paste (Zircate) (Zr), an aluminum oxide polishing paste (Prisma Gloss) (Pg), and combinations of them. The surface roughness of all groups was measured with a profilometer. The data were analyzed with a 2-way analysis of variance, and the mean values were compared by the Tukey Honestly Significant Difference test (a=0.05). RESULTS: For all porcelain material groups, the lowest Ra values were observed in Group Gl, Group Sl, Group Pk, and Group Di, which were not significantly different from each other (p>0.05).When comparing the 4 different porcelain materials, the machinable feldspathic porcelain block group (Mark II) demonstrated statistically significantly less Ra values than the other porcelain materials tested (p<0.05). No significant difference was observed between the VMK 95 and Ceramco III porcelain groups (p=0.919), also these groups demonstrated the highest Ra values. CONCLUSION: Subjected to surface roughness, the surfaces obtained with polishing and/or cleaning-prophy paste materials used alone were rougher compared to the surfaces finished using Sof-lex, Dialite, ...


Assuntos
Humanos , Polimento Dentário/métodos , Porcelana Dentária/química , Óxido de Alumínio/química , Silicatos de Alumínio/química , Polimento Dentário/instrumentação , Diamante/química , Teste de Materiais , Compostos de Potássio/química , Propriedades de Superfície , Silicatos/química , Zircônio/química
6.
J. appl. oral sci ; 17(5): 421-426, Sept.-Oct. 2009. ilus, graf
Artigo em Inglês | LILACS | ID: lil-531390

RESUMO

Cell culture system has been used to evaluate alloy cytotoxicity under different environments, testing the extracts, but the effect of temperature variation on the cytotoxicity of dental alloys has not been analyzed. OBJECTIVE: The aim of the present study was to investigate if temperature variation could affect dental alloy cytotoxicity, testing alloy extracts in an epithelial cell culture system. MATERIAL AND METHODS: Discs of Ni-Cr, Co-Cr-Mo, Ni-Cr-Ti, Ti-6Al-4V and commercially pure titanium (cp Ti) were cast by arc melting, under argon atmosphere, injected by vacuum-pressure. Discs were immersed in artificial saliva and subjected to different temperatures: 37ºC and thermocycling (37ºC/5ºC/37ºC/55ºC/37ºC). After thermocycling, extracts were put in a subconfluent culture during 6 h, and the number of cells and their viability were used to evaluate cytotoxicity in these temperatures. For each alloy, data from temperature conditions were compared by Student's t-test (α=0.05). RESULTS: The cytotoxicity tests with alloy/metal extracts showed that Ni-Cr, Co-Cr-Mo, Ti-6Al-4V and cp Ti extracts (p>0.05) did not affect cell number or cell viability, while Ni-Cr-Ti (p<0.05) extract decreased cell number and viability when the alloy was subjected to thermocycling. CONCLUSION: Within the limitations of the present study, the Ni-Cr-Ti alloy had cell number and viability decreased when subjected to temperature variation, while the other alloys/metal extracts did not show these results.


Assuntos
Humanos , Ligas Dentárias/toxicidade , Revestimento para Fundição Odontológica/toxicidade , Materiais Dentários/toxicidade , Titânio/toxicidade , Ligas/química , Ligas/toxicidade , Óxido de Alumínio/química , Materiais Biocompatíveis/química , Materiais Biocompatíveis/toxicidade , Contagem de Células , Linhagem Celular Tumoral , Compostos Inorgânicos de Carbono/química , Sobrevivência Celular/efeitos dos fármacos , Ligas de Cromo/química , Ligas de Cromo/toxicidade , Técnica de Fundição Odontológica , Corrosão Dentária , Ligas Dentárias/química , Revestimento para Fundição Odontológica/química , Materiais Dentários/química , Polimento Dentário/métodos , Diamante/química , Teste de Materiais , Saliva Artificial/química , Compostos de Silício/química , Dióxido de Silício/química , Temperatura , Titânio/química
7.
Braz. dent. j ; 17(3): 191-194, 2006. tab
Artigo em Inglês | LILACS | ID: lil-442365

RESUMO

During fabrication of bonded ceramic restorations, cervical adaptation, occlusal adjustment and final finishing/polishing are procedures to be performed at the dental office after adhesive cementation. Final adjustments may result in loss of ceramic glaze, which requires new polishing of the ceramic surface, with special attention for selection of adequate materials and instruments. The purpose of this study was to evaluate the efficiency of different vehicles associated with diamond pastes indicated for dental ceramic polishing. Two polishing pastes (Crystar Paste and Diamond Excell) associated with four vehicles (rubber cup, Robinson bristle brush, felt wheel and buff disc) were evaluated. Disc-shaped specimens were fabricated from Ceramco II dental ceramic. Surface roughness means (Ra) of the ceramic specimens were determined with a rugosimeter. Data were analyzed statistically by two-way ANOVA and Tukey's test at 5 percent significance level. There was no statistically significant difference (p>0.01) between the polishing pastes. However, there were statistically significant differences (p<0.01) among the tested vehicles. Vehicle-paste interaction showed statistically significant difference (p<0.05) as well. It may be concluded that: 1) Robinson bristle brush, felt wheel and buff disc were efficient vehicles to be used in association with a diamond polishing paste; 2) The use of rubber cup as a vehicle showed poor efficiency for mechanical polishing of the ceramic surfaces; 3) Both pastes provided similar and efficient polishing and may be recommended for use with an appropriated vehicle.


Durante a confecção de restaurações de cerâmica aderidas, a adaptação cervical, o ajuste oclusal e o polimento/acabamento final são procedimentos a serem executados no consultório odontológico após a cimentação adesiva. Os ajustes finais podem resultar na perda do "glaze" da cerâmica, o que requer novo polimento da superfície da restauração, necessitando de atenção especial em relação aos materiais e instrumentos adequados. O objetivo deste estudo foi avaliar a eficiência de diferentes veículos associados a pastas diamantadas indicadas para polimento de cerâmicas odontológicas. Duas pastas de polimento diamantadas (Crystar Paste and Diamond Excell) associadas a quatro veículos (taça de borracha, escova de Robinson, roda de feltro e disco de feltro) foram avaliadas. A cerâmica Ceramco II foi selecionada para a confecção dos espécimes. A rugosidade superficial (Ra) dos espécimes de cerâmica foi determinada por um rugosímetro. Os dados foram submetidos a análise de variância a dois critérios e ao teste de Tukey com nível de significância de 5 por cento. Não houve diferença estatisticamente significante (p>0,01) entre as pastas de polimento avaliadas. Contudo, houve diferença significante (p<0,01) entre os veículos. A interação veículo-pasta revelou diferença significante (p<0,05). Conlcuir que: 1) A escova de Robinson, a roda de feltro e o disco de feltro foram veículos efetivos para serem usados em associação com as pastas de diamante; 2) O uso da taça de borracha como veículo foi menos eficiente para o polimento mecânico das superfícies cerâmicas; 3) Ambas as pastas de polimento apresentaram comportamento similar e eficiente e podem ser indicadas para o polimento final de restaurações cerâmicas com um veículo apropriado.


Assuntos
Humanos , Materiais Dentários/química , Polimento Dentário/métodos , Porcelana Dentária/química , Diamante/química , Silicatos de Alumínio/química , Polimento Dentário/instrumentação , Desenho de Equipamento , Teste de Materiais , Compostos de Potássio/química , Propriedades de Superfície
8.
Braz. dent. j ; 17(4): 285-289, 2006. ilus
Artigo em Inglês | LILACS | ID: lil-442395

RESUMO

The purpose of this study was to test the hypothesis that mechanical polishing methods of ceramic surfaces allow similar superficial roughness to that of glazed surfaces. Twenty-five Vitadur Alpha ceramic discs (5 mm x 2 mm) were prepared according to the manufacturer's specifications. All specimens were glazed and randomly assigned to 5 groups (n=5), according to finishing and polishing protocols: G1: glazed (control); G2: diamond bur finishing; G3: G2 + silicon rubber tip polishing; G4: G3 + felt disc/diamond polishing paste; G5: G3 + felt disc impregnated with fine-particle diamond paste. Next, surface roughness means (Ra - æm) were calculated. Qualitative analysis was made by scanning electron microscopy. Surface roughness data were submitted to ANOVA and Tukey's test at 5 percent significance level. G1 and G4 were statistically similar (p>0.05). G2 presented the highest roughness means (p<0.05) followed by groups G3, G5, G4 and G1 in a decreasing order. The hypothesis was partially confirmed as only the mechanical polishing (G4) produced similar superficial roughness to that of surface glazing, although finishing and polishing are technically critical procedures.


O objetivo deste estudo foi testar a hipótese de que o acabamento e o polimento da superfície cerâmica produzem rugosidade superficial semelhante à superfície cerâmica vitrificada. Vinte e cinco corpos-de-prova (5 mm x 2 mm) da cerâmica Vitadur Alpha foram obtidos de acordo com as recomendações do fabricante. Todas os corpos-de-prova foram vitrificados e aleatoriamente divididos em 5 grupos (n=5), de acordo com os seguintes protocolos de acabamento e polimento: G1: vitrificação (controle); G2: abrasão com ponta diamantada; G3: G2 + acabamento com borrachas abrasivas; G4: G3 + polimento com pasta diamantada/disco de feltro; G5: G3 + disco de feltro impregnado com pasta diamantada. Após 6 análises individuais foi obtida 1 média por corpo-de-prova da rugosidade (Ra). A análise qualitativa foi realizada por microscopia eletrônica de varredura. Os valores médios de rugosidade foram submetidos à ANOVA e ao teste de Tukey com nível de significância de 5 por cento. G1 e G4 foram estatisticamente semelhantes (p>0.05). O grupo G2 apresentou o maior valor médio de rugosidade (p<0.05) seguido por G3, G5, G4 e G1 em ordem decrescente. A hipótese foi parcialmente confirmada, pois somente o polimento mecânico do grupo G4 produziu rugosidade superficial semelhante à da superfície vitrificada, embora o acabamento e o polimento sejam procedimentos críticos tecnicamente.


Assuntos
Humanos , Óxido de Alumínio/química , Silicatos de Alumínio/química , Cerâmica/química , Polimento Dentário/métodos , Porcelana Dentária/química , Compostos de Potássio/química , Polimento Dentário/instrumentação , Diamante/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Elastômeros de Silicone/química
9.
Braz. dent. j ; 14(1): 37-41, June 2003. tab
Artigo em Inglês | LILACS | ID: lil-340487

RESUMO

This study evaluated the effect of surface finishing methods on the average surface roughness of resin composites. Seven composites and two polishing systems were used. One hundred and twenty-six conical specimens of each material were prepared in stainless steel molds against a polyester strip. Forty-two of them remained intact and were used as controls. Each half of the remaining samples was polished with either diamond burs or diamond burs + aluminum oxide discs. The results showed no statistical difference in average surface roughness (Ra, µm) between the polyester strip and aluminum oxide discs (p>0.05). However, finishing with diamond burs showed a statistically higher average roughness for all composites (p<0.05). Statistical differences were detected among materials (p<0.05) in the use of diamond burs


Assuntos
Humanos , Resinas Compostas/química , Polimento Dentário , Análise de Variância , Óxido de Alumínio/química , Bis-Fenol A-Glicidil Metacrilato/química , Polimento Dentário/instrumentação , Diamante/química , Metacrilatos/química , Poliésteres/química , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Poliuretanos/química , Estatística como Assunto , Propriedades de Superfície , Siloxanas/química , Aço Inoxidável/química , Terpenos/química
10.
RPG rev. pos-grad ; 7(1): 64-73, jan.-mar. 2000. ilus, tab, graf
Artigo em Português | LILACS, BBO | ID: lil-298260

RESUMO

Foi utilizado um método inédito para a avaliaçäo do desempenho (tempo de vida útil) de pontas diamantadas, especialmente confeccionadas com 8 tipos de gräos (naturais e sintéticos), cortando-se substrato constituído por vidro, o qual era movimentado contra a ponta em açäo. Estabelecida uma série de necessárias condiçöes operatórias, os valores de tensäo e corrente elétrica no motor da caneta (a qual prendia a ponta em ensaio) eram basicamente transferidos para um microcomputador, onde em tempo real era calculado o valor da respectiva força tangencial de corte, através de um programa de computaçäo especialmente desenvolvido, o qual efetuava uma série de cálculos matemáticos, criando gráficos e mantendo o registro de todos os valores verificados. Nas condiçöes estabelecidas, em ordem decrescente de magnitude da vida útil, os gräos de diamante avaliados assim se comportaram: PDA 433, DMB-T, DMB-G, PDA 555, PDA 665, PDA 768, TED-II e PDA 878


Assuntos
Diamante/análise , Instrumentos Odontológicos/normas , Diamante/química , Diamante/classificação , Gráficos por Computador/estatística & dados numéricos , Gráficos por Computador/instrumentação , Materiais Dentários/análise , Materiais Dentários/classificação , Materiais Dentários/química , Computação Matemática
11.
Saudi Journal of Disability and Rehabilitation. 2000; 6 (3): 196-201
em Inglês | IMEMR | ID: emr-55212
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA