Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Artigo em Inglês | IMSEAR | ID: sea-140009

RESUMO

Background and Objectives: Aim of this study was to determine the validity of cervical vertebrae radiographic assessment to predict skeletal maturation. Materials and Methods: Left-hand wrist and lateral cephalometric radiographs of 100 Bangalore children aged 8-18 years, divided into 10 groups of 10 subjects each with equal distribution of males and females, were measured. On left-hand wrist radiograph, the classification of Fishman was used to assess skeletal maturation. Cervical vertebrae maturation was evaluated with lateral cephalometric radiograph, using the stages developed by Hassel and Farman. The changes in hand wrist and cervical vertebrae were correlated. Results: Significant association was observed between skeletal maturation indicator stages and cervical vertebrae maturation indicator stages. Correlation coefficient was found to be significant (P<0.0001). Conclusion: The results of the study indicated that the cervical vertebrae maturation and hand wrist skeletal maturation was significantly related.


Assuntos
Adolescente , Determinação da Idade pelo Esqueleto/métodos , Vértebra Cervical Áxis/crescimento & desenvolvimento , Vértebra Cervical Áxis/diagnóstico por imagem , Desenvolvimento Ósseo/fisiologia , Ossos do Carpo/crescimento & desenvolvimento , Ossos do Carpo/diagnóstico por imagem , Cefalometria/métodos , Vértebras Cervicais/crescimento & desenvolvimento , Vértebras Cervicais/diagnóstico por imagem , Criança , Feminino , Previsões , Ossos da Mão/crescimento & desenvolvimento , Ossos da Mão/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Radiografia Dentária Digital/métodos , Fatores Sexuais , Tomografia Computadorizada por Raios X/métodos , Ecrans Intensificadores para Raios X
2.
Artigo em Inglês | IMSEAR | ID: sea-139993

RESUMO

Background and Objective: Digital photo stimulable phosphor (PSP)-based radiography has many known theoretical advantages over conventional film radiography but its diagnostic efficacy has to be assessed clinically. This study compared the efficiency of conventional film-based panoramic radiographs with that of digital PSP-based panoramic radiographs in the assessment of position and morphology of impacted mandibular third molars. Materials and Methods: We selected a total of 80 impacted mandibular third molars that fulfilled the inclusion and exclusion criteria of this study. Both conventional film-based panoramic radiographs and digital PSP-based panoramic radiographs were taken of all the study samples and the teeth were later surgically removed. Conventional film-based and digital PSP-based panoramic radiographs were compared for their relative efficiencies in the assessment of impaction status, position of tooth, number of roots, root morphology, and proximity to mandibular canal of impacted mandibular third molars. An oral surgeon graded these same factors during/after surgical exploration and this assessment was considered the gold standard. The data obtained were statistically analyzed using descriptive statistics, chi-square test, and McNemar's test. Results: There was no statistically significant difference between conventional film-based radiographic assessment and digital PSP-based panoramic radiographic assessment of impaction status, position of tooth, number of roots, and proximity to mandibular canal of impacted mandibular third molars (P>0.05). However, there was significant difference between the two methods with regard to assessment of root morphology of impacted mandibular third molars (P=0.00). Interpretation and Conclusion : Conventional film-based panoramic radiographs and digital PSP-based panoramic radiographs were comparable in their accuracy in the preoperative study of impacted mandibular third molar with regard to impaction status, tooth position, number of roots, and proximity to the mandibular canal. Digital PSP-based panoramic radiographs were more accurate than conventional film-based panoramic radiographs in the assessment of root morphology of impacted mandibular third molars. Hence, we conclude that digital PSP-based panoramic radiographs can be used as an effective alternative to conventional film-based panoramic radiographs for assessment of position and morphology of impacted mandibular third molars.


Assuntos
Adulto , Arco Dental/diagnóstico por imagem , Feminino , Humanos , Masculino , Mandíbula/diagnóstico por imagem , Nervo Mandibular/diagnóstico por imagem , Dente Serotino/diagnóstico por imagem , Dente Serotino/cirurgia , Radiografia Dentária Digital/normas , Radiografia Panorâmica/normas , Raiz Dentária/diagnóstico por imagem , Dente Impactado/diagnóstico por imagem , Dente Impactado/cirurgia , Filme para Raios X/normas , Ecrans Intensificadores para Raios X/normas , Adulto Jovem
3.
Korean Journal of Radiology ; : 320-326, 2010.
Artigo em Inglês | WPRIM | ID: wpr-183837

RESUMO

OBJECTIVE: To investigate the clinical feasibility of dual energy subtraction (DES) imaging to improve the delineation of the vocal cord and diagnostic accuracy of vocal cord paralysis as compared with the anterior-posterior view of flat panel detector (FPD) neck radiography. MATERIALS AND METHODS: For 122 consecutive patients who underwent both a flexible laryngoscopy and conventional/DES FPD radiography, three blinded readers retrospectively graded the radiographs during phonation and inspiration on a scale of 1 (poor) to 5 (excellent) for the delineation of the vocal cord, and in consensus, reviewed the diagnostic accuracy of vocal cord paralysis employing the laryngoscopy as the reference. We compared vocal cord delineation scores and accuracy of vocal cord paralysis diagnosis by both conventional and DES techniques using kappa statistics and assessing the area under the receiver operating characteristic curve (AUC). RESULTS: Vocal cord delineation scores by DES (mean, 4.2 +/- 0.4) were significantly higher than those by conventional imaging (mean, 3.3 +/- 0.5) (p < 0.0001). Sensitivity for diagnosing vocal cord paralysis by the conventional technique was 25%, whereas the specificity was 94%. Sensitivity by DES was 75%, whereas the specificity was 96%. The diagnostic accuracy by DES was significantly superior (kappa = 0.60, AUC = 0.909) to that by conventional technique (kappa = 0.18, AUC = 0.852) (p = 0.038). CONCLUSION: Dual energy subtraction is a superior method compared to the conventional FPD radiography for delineating the vocal cord and accurately diagnosing vocal cord paralysis.


Assuntos
Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Absorciometria de Fóton/instrumentação , Estudos de Viabilidade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração , Paralisia das Pregas Vocais/diagnóstico por imagem , Prega Vocal/diagnóstico por imagem , Ecrans Intensificadores para Raios X
4.
Artigo em Inglês | IMSEAR | ID: sea-51529

RESUMO

OBJECTIVE: The purpose of this study was to compare the subjective image quality of (1) regular intensifying screens with medium intensifying screens, (2) regular intensifying screens with digital radiography, and (3) medium intensifying screens with digital radiography for panoramic radiographs. MATERIALS AND METHODS: Forty-five patients participated and a total of 90 radiographs were obtained in the study. The patients were divided into three groups (regular-medium intensifying screen, regular intensifying screen-digital radiography, and medium intensifying screen-digital radiography) that consisted of 15 people each. All radiographs were assessed by three oral radiologists independently. The observers evaluated the images using a 3-point scale (1=well visible, 0=partly visible, -1=not or hardly visible) for anatomical structures and pathological findings that are commonly found on panoramic radiographs. Subjective image quality of the groups and comparison of the observers were assessed by using non parametric Kruskal Wallis and Mann-Whitney U tests. RESULTS: For all groups and observers, no statistically significant difference (p>0.05) was found for both anatomical structures and pathologies and between anatomical structures and pathologies according to the Mann Whitney U test. In comparison with observers, no statistically significant difference (p>0.05) was found for both anatomical structures and pathologies and between anatomical structures and pathologies for all groups according to the Kruskal Wallis test. CONCLUSION: The subjective image quality of medium and regular intensifying screens and conventional and digital panoramic radiographs were found statistically equal in this study.


Assuntos
Feminino , Humanos , Masculino , Radiografia Dentária Digital/instrumentação , Radiografia Dentária Digital/métodos , Radiografia Panorâmica/instrumentação , Radiografia Panorâmica/métodos , Percepção Visual , Filme para Raios X , Ecrans Intensificadores para Raios X , Adulto Jovem
5.
Journal of Biomedical Engineering ; (6): 59-62, 2009.
Artigo em Chinês | WPRIM | ID: wpr-318111

RESUMO

Using the present cone beam reconstruction formula for general trajectory, we have investigated the issue of detector efficiency for non-helical trajectory. The results reveal that the two factors dominating the detector efficiency are detector geometry and filtering directions. The methods for to higher detector efficiency are proposed, and the reliability and feasibility are tested by simulation results.


Assuntos
Humanos , Tomografia Computadorizada de Feixe Cônico , Métodos , Processamento de Imagem Assistida por Computador , Métodos , Intensificação de Imagem Radiográfica , Métodos , Espalhamento de Radiação , Ecrans Intensificadores para Raios X
6.
J. appl. oral sci ; 16(5): 350-354, Sept.-Oct. 2008. ilus, tab
Artigo em Inglês | LILACS | ID: lil-495140

RESUMO

This ex vivo study evaluated the quality of digital radiographic images obtained with the photostimulable phosphor plate system (Digora) according to the processing delay and maintenance of optical plates in either opaque (supplied with the system) or transparent protective plastic cases during this period. Five radiographs were obtained from the mandibular molar region of a dry human mandible using optical plates. These plates were placed in the protective plastic cases before obtaining the radiographs and were processed immediately or after processing delays of 5, 60 and 120 min, when the case was removed. The results revealed a reduction in image quality when processing was delay 120 min compared to the other times. The opaque case provided better protection to the sensor than the transparent case. In conclusion, a 120-min processing delay for the Digora system caused a reduction in image quality, yet without interfering with the quality of diagnosis. The opaque case supplied by the system's manufacturer provided better protection to the optical plate than the transparent case.


Assuntos
Humanos , Radiografia Dentária Digital/instrumentação , Radiografia Dentária Digital/métodos , Ecrans Intensificadores para Raios X , Cadáver , Mandíbula , Plásticos , Fatores de Tempo
7.
Rev. bras. eng. biomed ; 24(2): 109-119, ago. 2008. ilus, tab
Artigo em Português | LILACS | ID: lil-576307

RESUMO

Falhas na execução de uma imagem radiográfica ou durante o processamento dos filmes geram interpretações errôneas, repetição do exame, maior exposição dos pacientes à radiação, além de aumentar o tempo clínico e os custos. A seleção correta dos parâmetros de exposição radiográfica proporciona a aquisição de imagens radiográficas com contraste, nitidez, detalhes, densidade óptica e definição das estruturas anatômicas para a realização de laudos radiográficos confiáveis. Assim sendo, neste artigo é apresentado um método computacional que pode auxiliar na seleção dos parâmetros de exposição mais apropriados para um dado exame radiográfico. As densidades ópticas foram simuladas considerando a composição e a espessura dos tecidos da estrutura anatômica, as características do aparelho de raios  X e do sistema écran-filme e os parâmetros de exposição otimizados conforme regras encontradas na literatura. Cinco radiologistas experientes avaliaram imagens radiográficas adquiridas de simuladores antropomórficos com parâmetros de exposição sugeridos pelo método computacional desenvolvido e também parâmetros encontrados na literatura. Após analisarem o contraste (diferença de densidade óptica em áreas adjacentes) e a nitidez (presença de detalhes visíveis tais como linhas estruturais finas, bordas de tecidos ou estruturas de interesse diagnóstico), os radiologistas opinaram que as imagens adquiridas com os parâmetros de exposição sugeridos pelo método computacional proposto proporcionaram um bom diagnóstico. Além disso, os valores de densidade óptica medidos nas imagens radiográficas numa posição correspondente ao centro do campo de radiação também apresentaram uma boa correlação com aqueles calculados pelo método, em torno de 90%. Este método pode se tornar também um valioso recurso didático para treinamento de novos profissionais para o setor radiológico.


Radiographic images of good quality allow adequate diagnosis. However imperfections in the selection process of exposure parameters, or during the film processing, generate erroneous interpretations or exam repetition, resulting in major exposure of patients to the radiation, and increasing the clinical time and costs. This article presents a computer method that helps the choice of better exposure parameters. The optical densities had been simulated taking into account tissue composition and thickness of the anatomical structure, characteristics of the X-ray equipment and screen-film system, and radiographic exposure parameters optimized according to rules found in literature. Five experienced radiologists evaluated the radiographic images obtained from anthropomorphic phantoms with the exposure parameters suggested by proposed method (named MD), and also with others parameters found in literature. After analyzing the image contrast and sharpness, they declared that the MD images provide a good diagnosis. Besides, the optical density values measured in these radiographic images on the position corresponding to the center of radiation field presented a good agreement (correlation of 90%) with those values calculated by the proposed method. This method can also become a valuable didactic resource for training of new professionals for the radiological sector.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia/métodos , Radiografia/normas , Diagnóstico por Imagem/métodos , Doses de Radiação , Ecrans Intensificadores para Raios X , Controle de Qualidade , Padrões de Referência , Relação Dose-Resposta à Radiação , Sensibilidade e Especificidade , Tecnologia Radiológica/métodos
8.
Braz. oral res ; 22(1): 78-83, Jan.-Mar. 2008. ilus, tab
Artigo em Inglês | LILACS | ID: lil-480588

RESUMO

This study aimed at investigating the effect of the partial erasing of DenOptix® system storage phosphor plates on the image quality of digital radiographs. Standardized digital radiographs were acquired of a phantom mandible, using size 2 intraoral DenOptix® storage phosphor plates (n = 10). Subsequently, the active areas of the plates were placed in a viewing box with a constant light intensity of 1,700 lux for 130 seconds to achieve complete erasing (control plate), as well as for 0, 5, 10, 15, 20, 25, 34, 66, and 98 seconds, to compose the experimental group of partially erased plates. The same exposure settings were repeated using the control and experimental plates, which were scanned at a resolution of 300 dpi. Five radiologists independently examined the pairs of digital radiographs obtained with the control and partially erased plates, in random order, and indicated the best image for oral diagnosis. Cochran-Mantel-Haenszel’s chi-square test, at a significance level of 5 percent, was used to compare the percentages of superior quality images in each combination of control and partially erased plates, subjectively assessed. No significant differences were found between radiographic images acquired with control and partially erased plates, except for the combination of 0 second (30 percent) versus 130 seconds (70 percent), p = 0.0047. It can be concluded that, under adequate light intensity conditions, erasing intraoral DenOptix® storage phosphor plates may require time intervals of as little as 5 seconds.


Assuntos
Intensificação de Imagem Radiográfica/normas , Ampliação Radiográfica/normas , Radiografia Dentária Digital/normas , Distribuição de Qui-Quadrado , Processamento de Imagem Assistida por Computador , Luz , Medições Luminescentes , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Ampliação Radiográfica/métodos , Radiografia Dentária Digital/métodos , Software , Fatores de Tempo , Ecrans Intensificadores para Raios X
9.
Chinese Journal of Medical Instrumentation ; (6): 431-433, 2008.
Artigo em Chinês | WPRIM | ID: wpr-309558

RESUMO

A kind of rural digital radiography systems is introduced In this paper, including its design, constructural characteristics, and the implementing methods. Meanwhile time, it is pointed out that detail considerations should be given to the system features, key components selection and clinical workflow. Serviceability and ease of as for developments of rural digital radiography systems are also mentioned.


Assuntos
Humanos , China , Desenho de Equipamento , Processamento de Imagem Assistida por Computador , Métodos , Intensificação de Imagem Radiográfica , Saúde da População Rural , Ecrans Intensificadores para Raios X
10.
Braz. oral res ; 20(3): 207-213, Jul.-Sept. 2006. ilus, tab
Artigo em Inglês, Português | LILACS | ID: lil-435807

RESUMO

The objective of the present study was to determine the reproducibility of the pixel values obtained with the Digora system (Soredex, Finland). Exposures were standardized, with variation in exposure and scanning time of two photostimulable phosphor plates containing a stepwedge image. The smallest variation in pixel values ranged from 50 to 75 percent, with the widest variations being observed in less dense steps. A significant difference in pixel values was observed in terms of X-ray exposure and scanning times and between the two plates themselves (ANOVA, p < 0.01). Using the present methodology, the reproducibility of pixel values was not satisfactory for the tested white photostimulable plates. This wide variation in digitalization might be influenced by the amount of X-rays that sensitized the plates. It may be important to establish the reproducibility of the pixel values in quantitative studies using digital image.


O objetivo do presente trabalho foi determinar a reprodutibilidade dos valores de "pixels" obtidos com o sistema Digora (Soredex, Finlândia). As exposições foram padronizadas, com variação no tempo de exposição e leitura de duas placas de fósforo fotoestimuláveis contendo a imagem de um penetrômetro. A menor variação nos valores de "pixels" foi de 50 a 75 por cento, sendo as maiores variações oriundas nas faixas mais claras. Uma diferença significante nos valores de "pixels" foi observada em relação ao tempo de exposição e leitura das placas e entre as duas placas (ANOVA, p < 0,01). Utilizando a presente metodologia, a reprodutibilidade dos valores de "pixels" das placas testadas do sistema Digora não foi satisfatória. Essa grande variação na digitalização pode ter sido influenciada pela quantidade de Raios X que sensibilizou as placas. Isso pode ser importante para estabelecer a reprodutibilidade dos valores de "pixels" em estudos quantitativos usando imagem digital.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Intensificação de Imagem Radiográfica/normas , Radiografia Dentária Digital/instrumentação , Ecrans Intensificadores para Raios X , Análise de Variância , Instrumentos Odontológicos , Luz , Medições Luminescentes , Imagens de Fantasmas , Reprodutibilidade dos Testes , Radiografia Dentária Digital/métodos
11.
Chinese Journal of Medical Instrumentation ; (6): 402-406, 2002.
Artigo em Chinês | WPRIM | ID: wpr-344246

RESUMO

In this paper, the question about automatic brightness control for x-ray imaging systems based on CCD camera is discussed, and the structure and principle of an auto brightness control loop are analyzed along with the working procedure of the x-ray imaging system. A kind of digital brightness controller about a typical device and the designing idea of the computer brightness intelligent control software is introduced.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Proteção Radiológica , Intensificação de Imagem Radiográfica , Radiografia , Ecrans Intensificadores para Raios X
12.
Rev. chil. tecnol. méd ; 20(1/2): 855-64, 2000. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: lil-295220

RESUMO

En la mayoría de los Servicios y Centros Radiológicos de nuestro país se utilizan los sistemas detectores de pantalla-película de fósforos de tierras raras con emisión de luz verde y película sencible a la misma; sin embargo, en algunos Centros del Sistema Público de Salud aún se utilizan pantalla película convencionales de tungstato de calcio, que emite luz azul, con película sencible a este color (por ej: en el Hospital San Juan de Dios, Peumo, Quillota, Puerto Natales, San José de Maipo). El objetivo del presente artículo es proporcionar a los profesionales herramientas que les permitan optimizar el empleo de los sistemas detectores, que son elementos accesorios de gran importancia de la abtención de imágenes radiográficas de alta calidad diagnóstica, logrando además disminuir la dosis de irradiación al paciente y una mayor duración del tubo de rayos X, entre otras características


Assuntos
Humanos , Filme para Raios X/tendências , Ecrans Intensificadores para Raios X/tendências , Metais Terras Raras , Tecnologia Radiológica/métodos
13.
Rev. argent. radiol ; 61(1): 19-24, ene.-mar. 1997. ilus
Artigo em Espanhol | LILACS | ID: lil-197047

RESUMO

Es sabido que la detección precoz de la arterosclerosis coronaria disminuye el riesgo de infarto. Con tal motivo se estudiaron 104 pacientes, de 52 años de edad promedio, mediante radioscopia TV. De acuerdo a los resultados de la calcificación coronaria CC y al número de territorios involucrados se clasificaron los pacientes en varios grupos, concluyendo que la radioscopia TV es un método de alta sensibilidad, bajo costo, rapidez y seguridad para la detección de CC


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Calcinose/diagnóstico , LDL-Colesterol , Doença da Artéria Coronariana/diagnóstico , Diagnóstico por Imagem , Hiperlipidemias/diagnóstico , Lipoproteína(a) , Ecrans Intensificadores para Raios X/estatística & dados numéricos , Calcinose , Calcinose/etiologia , LDL-Colesterol/efeitos adversos , LDL-Colesterol/sangue , Doença da Artéria Coronariana , Doença das Coronárias , Doença das Coronárias/sangue , Doença das Coronárias/diagnóstico , Diagnóstico por Imagem , Hiperlipidemias/sangue , Hiperlipidemias/complicações , Lipoproteína(a)/efeitos adversos , Lipoproteína(a)/sangue
14.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.439-440, ilus, graf.
Monografia em Português | LILACS | ID: lil-236433

RESUMO

Este trabalho baseia-se em levantamentos radiométricos feitos nos modos de fluoroscopia e grafia, considerando medidas de feixe primário e secundário, com o objetivo da avaliação das taxas de exposição a que estão submetidos o paciente, o médico, o anestesista e demais membros da equipe executora de exames de radiologia vascular periférica.


Assuntos
Angiografia , Fluoroscopia , Ecrans Intensificadores para Raios X , Mapa , Equipamentos e Provisões Hospitalares , Exposição à Radiação , Hemodinâmica
15.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.437-438, ilus.
Monografia em Português | LILACS | ID: lil-236432

RESUMO

As características do ponto focal do tubo de raios-X são o fator limitante da capacidade de resolução espacial em muitos sistemas radiográfios, e variam consideravelmente quando observadas em diferentes pontos de campo de radiação. Desta forma, é importante não somente conhecer estas características, como também a posição exata a partir da qual foram medidas. Neste trabalho, estamos propondo um novo dispositivo eletrônico para localização do raio central do cone de radiação, a fim de possibilitar um perfeito alinhamento dos objetos de teste utilizados na avaliação do ponto focal com eixo de referência.


Assuntos
Raios X , Campos Eletromagnéticos , Ecrans Intensificadores para Raios X , Exposição à Radiação
16.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.431-432, ilus.
Monografia em Português | LILACS | ID: lil-236429

RESUMO

Este trabalho descreve um método para prever a influência do sistema de registro sobre a nitidez de imagens radiográficas por simulação computacional, procurando apresentar previamente a imagem a ser obtida para cada tipo de filme ou combinação écran-filme usada durante a exposição.


This work describes a method aimed to predict the influence of the record system on radiographic images sharpness by computer simulation. This method is intended to previously show the image to be obtained for each type of film or screen-film combination used during the exposure. l


Assuntos
Ecrans Intensificadores para Raios X , Sistema de Registros , Interpretação de Imagem Radiográfica Assistida por Computador , Simulação por Computador , Controle de Qualidade , Raios X , Imagens de Fantasmas
17.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.407-408, ilus, tab.
Monografia em Português | LILACS | ID: lil-236417

RESUMO

Neste trabalho é discutida uma metodologia comparativa entre técnicas convencionais de midição das dimensões do ponto focal de tubos de raios-X e uma nova técnica utilizando recursos para aquisição digital de imagens. São apresentados resultados de medições com ambos os métodos.


This work shows a comparative methodology between standard techniques for evaluation of X-ray tubes focal spots and a newer one which uses digital resources for image acquisition. Results from measurements by using both methods are presented


Assuntos
Raios X , Equipamentos e Provisões , Ecrans Intensificadores para Raios X , Radiografia , Odontologia
19.
In. Freitas, Leonidas de. Radiologia bucal: técnicas e interpretaçäo. Säo Paulo, Pancast, 1992. p.52-63, ilus, graf.
Monografia em Português | LILACS, BBO | ID: lil-250616
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA