Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Annals of Laboratory Medicine ; : 50-56, 2015.
Artigo em Inglês | WPRIM | ID: wpr-34576

RESUMO

BACKGROUND: The bacterium Chlamydia trachomatis is one of the leading causes of sexually transmitted diseases worldwide. Since no simple and effective tool exists to diagnose C. trachomatis infections, we evaluated a novel point-of-care (POC) test, aQcare Chlamydia TRF kit, which uses europium-chelated nanoparticles and a time-resolved fluorescence reader. METHODS: The test performance was evaluated by comparing the results obtained using the novel POC testing kit with those obtained using a nucleic acid amplification test (NAAT), using 114 NAAT-positive and 327 NAAT-negative samples. RESULTS: The cut-off value of the novel test was 20.8 with a detection limit of 0.27 ng/mL. No interference or cross-reactivity was observed. Diagnostic accuracy showed an overall sensitivity of 93.0% (106/114), specificity of 96.3% (315/327), positive predictive value (PPV) of 89.8% (106/118), and negative predictive value (NPV) of 97.5% (315/323). The sensitivity of the novel test was much higher than that of currently available POC tests. Furthermore, the relative ease and short turnaround time (30 min) of this assay enables C. trachomatis-infected individuals to be treated without a diagnostic delay. CONCLUSIONS: This simple and novel test is a potential tool to screen a larger population, especially those in areas with limited resources.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Infecções por Chlamydia/diagnóstico , Chlamydia trachomatis/genética , DNA Bacteriano/química , Európio/química , Nanopartículas Metálicas/química , Sistemas Automatizados de Assistência Junto ao Leito , Kit de Reagentes para Diagnóstico , Reação em Cadeia da Polimerase em Tempo Real , Sensibilidade e Especificidade
2.
Journal of Biomedical Engineering ; (6): 785-789, 2007.
Artigo em Chinês | WPRIM | ID: wpr-346070

RESUMO

A new biocompatible apatite-wollastonite magnetic glass ceramic has been synthesized via sol-gel process. Characteristics of the materials were determined with differential thermal analysis (DTA), X-ray diffraction (XRD), scan electron microscopy (SEM), energy dispersive spectrum (EDS), inductively couple plasma atomic emission spectroscopy (ICP-AES), vibrating sample magnetometer (VSM) and so on. Results showed that the main crystalline phases of the material were hydroxyapatite/fluoroapatite [Ca10(PO4)6(OH, F)), beta-wollastonite[beta-CaSiO3] and calcium europium oxide silicate Ca2Eu8[(SiO4)6O2]. The magnetization of the sample contanining 2% Eu2O3 in weight reached 2.18 emu/g for an applied field of 10 000Oe. Hydroxyapatite layer could form on the surface of the sample while soaking for 14 days in simulated body fluid. Good bioactivity was demonstrated. So it is a potential bone repairing material as well as a hyperthemia treatment material for pateints with cancer.


Assuntos
Apatitas , Química , Materiais Biocompatíveis , Química , Substitutos Ósseos , Química , Cerâmica , Química , Európio , Química , Magnetismo , Microscopia Eletrônica de Varredura , Porosidade , Ácido Silícico , Química , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA