Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
J. health med. sci. (Print) ; 7(4): 231-238, oct.-dic. 2021. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1391707

RESUMO

To ensure a reliable verification of a radiation detector, the right parameters for this response verification must be determined and a specific characterization on the detectors of interest must be performed. These were the main pillars of this study, where four Geiger-Müller at the University of Costa Rica's Cyclotron Facilities' main laboratories were studied and characterized using a 137Cs source. First, a verification of the inverse-square law was performed to corroborate the correct measurement by the detectors as the distance from a 137Cs source to the detectors was varied using a new design for a positioner support to ensure repeatability. This verification yielded a potential fit curve with and equation D=670635 x-1.961 (error percentage of 1.95%) and an R2 value of 0.9836. Then, using combinations of copper plates of widths 1.0 mm and 2.0 mm as attenuators between the source and the detectors, the mass attenuation coefficient for copper was obtained only as a reference value for future calibrations of the detectors. The result for this value was 0.040 cm2 /g. The results obtained in this study and the method developed to achieve these results will serve as a base for calibrations of the detectors at these facilities, which will ensure the safety of the patients and personnel in this building.


Para asegurar respuesta correcta de un detector de radiación, se deben determinar los parámetros correctos para esta verificación y debe realizarse una caracterización específica de los detectores de interés. Estos fueron los pilares principales de este estudio, donde se estudiaron y caracterizaron 4 detectores Geiger-Müller en los laboratorios principales del Ciclotrón de la Universidad de Costa Rica utilizando una fuente radiactiva de 137Cs. Primero, se realizó una verificación de la ley del inverso-cuadrado para corroborar la medición correcta de los detectores según se varía la distancia entre la fuente de 137Cs al detector utilizando un diseño nuevo de un soporte posicionador para la fuente que asegura la repetibilidad entre experimentos. Esta verificación resultó en una curva de ajuste potencial de ecuación D=670635x-1,961 (porcentaje de error de 1,95%) y un valor de R2 de 0,9836. Luego, utilizando combinaciones de placas de cobre de espesores 1,0 mm y 2,0 mm como atenuadores entre la fuente y los detectores, se obtuvo el coeficiente de atenuación másico para el cobre como un valor de referencia para futuras calibraciones de los detectores. Este resultado fue de 0,040 cm2/g. Los resultados obtenidos en esta investigación y el método desarrollado para lograr estos resultados servirán como una base para una futura confirmación metrológica calibraciones de los detectores en estos laboratorios, lo cual colaborará con la seguridad y protección radiológica de pacientes y trabajadores en este edificio.


Assuntos
Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Radiometria/instrumentação , Radiometria/métodos , Universidades , Calibragem , Radioisótopos de Césio , Ciclotrons , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Costa Rica
2.
Braz. j. pharm. sci ; 50(1): 101-106, Jan-Mar/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-709539

RESUMO

To investigate the effects of sanguinarine (SAN) on acute radiation induced injury in mice, 45 mice were randomly divided into control, 10 Gy and SAN+10 Gy groups. Mice in the 10 Gy and SAN+10 Gy groups were exposed to single X-ray radiation with an accumulated dose of 10 Gy. Mice in the SAN+10 Gy group were administered intraperitoneally with 2.5 mg/kg body weight of SAN before radiation. Five days after radiation exposure, 5 mice from each group were sacrificed and samples of the small intestine, lung, spleen and liver were fixed for histopathological examinations. Compared with the 10 Gy group, radiation sickness was obviously delayed or attenuated in the SAN+10 Gy group. Survival analysis showed a significant difference between 2 radiation groups (P<0.05) and mean survival time was 3 days longer in the SAN+10 Gy group than in the 10 Gy group (7.21±0.19 vs. 4.20±0.13, P<0.001). Radiation-induced organ damage, based on histopathological examinations, was decreased by SAN pretreatment. Chiu’s pathology grading scores, which is an index of intestinal damage, was significantly lower in the SAN+10 Gy group than in the 10 Gy group (2.77±0.48 vs. 4.37±0.31, P<0.01). A similar result was obtained in the pathological score of lung (1.67±0.21 vs. 2.33±0.38, P<0.01). Our preliminary findings demonstrated that SAN protects animals against radiation-induced sickness and acute damage to organs and following animal death.


Para investigar os efeitos da sanguinarina (SAN) em lesões induzidas em ratos por radiação aguda, 45 ratos foram aleatoriamente divididos em grupo controle, grupo 10 Gy e grupo SAN+10 Gy. Os ratos dos grupos 10 Gy e SAN+10 Gy foram expostos à radiação de raio-X simples com uma dose acumulada de 10 Gy. Aos ratos do grupo SAN+10 Gy administraram-se, intraperitonealmente, 2.5 mg/kg de peso de SAN antes da radiação. Aos 5 dias de exposição à radiação, sacrificaram-se 5 ratos de cada grupo e retiraram-se amostras do intestino delgado, pulmões, baço e fígado para exames histopatológicos. Comparando com o grupo 10 Gy, a doença por radiação foi claramente atrasada e atenuada no grupo SAN+10 Gy. A análise de sobrevivência mostrou diferença significativa entre os dois grupos de radiação (P<0.05) e o tempo de sobrevivência média foi de mais 3 dias no grupo SAN+10 Gy do que no grupo 10 Gy (7.21±0.19 vs 4.20±0.13, P<0.001). Danos induzidos nos órgãos por radiação, baseados em exames histopatológicos, foram reduzidos pelo pré-tratamento com SAN. As pontuações de classificação da patologia Chiu, um índice para os danos intestinais, foi significativamente menor no grupo SAN+10 Gy do que no grupo 10 Gy (2.77±0.48 vs 4.37±0.31, P<0.01). Resultado semelhante foi obtido na pontuação patológica do pulmão (1.67±0.21 vs 2.33±0.38, P<0.01). As nossas descobertas preliminares mostram que SAN protege os animais contra doenças induzidas pela radiação e danos agudos nos órgãos seguidos de morte animal.


Assuntos
Animais , Ratos , /efeitos da radiação , /efeitos da radiação , Camundongos Endogâmicos BALB C , Raios X/efeitos adversos , Exposição à Radiação/análise , Controle da Exposição à Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA