Resultados 1 - 20 de 25
Filtrar
1.
Rev. bras. oftalmol ; 81: e0043, 2022. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1387977

RESUMO

ABSTRACT Objective: To evaluate the efficacy of low-cost nucleus fragmenting forceps designed to reduce the use of ultrasound during phacoemulsification. Methods: A total of 60 pig eyes enucleated 10 hours before were placed in the microwave oven, at maximum power for 10 seconds, to form cataracts with hardness comparable to a grade IV nucleus in the Lens Opacities Classification System III. Cataract extraction was performed using the Centurion® phacoemulsifier (Alcon Laboratories, Geneve, Switzerland) and Leica M620 microscope. All eyes were submitted to the pre-chop technique dividing the nucleus into four parts. After the pre-chop, the quadrants in 30 eyes were phacoemulsified with the torsional mode and were fragmented in the remaining 30 eyes after the pre-chop was with the fragmentation forceps before torsional mode phacoemulsification. The device was calibrated for all eyes by applying the following parameters: 40% linear torsional phacoemulsification; intraocular pressure of 65 mmHg; the linear vacuum of 600 mmHg; aspiration flow of 40 ccs/minute. After each procedure, the following was recorded: cumulative dissipated energy; equivalent average torsional amplitude; equivalent average ultrasonic power; estimated aspirated fluid; ultrasound total time; and total aspiration time. Statistical analysis was performed using the Kruskal-Wallis test and the IBM Statistical Package for Social Sciences. The p-value <0.05 was considered statistically significant. Results: There was a statistically significant reduction favoring the use of the nucleus fragmenting forceps in all parameters, except for the average torsional amplitude. Conclusion: The use of the nucleus fragmenting forceps contributed to improving the efficacy of torsional phacoemulsification in enucleated pig eyes.


RESUMO Objetivo: Avaliar a eficácia de uma pinça fragmentadora de núcleo, de baixo custo, desenvolvida para reduzir o uso de ultrassom durante a emulsificação do núcleo. Métodos: Sessenta olhos de porco com 10 horas de enucleação foram colocados no forno de microondas, em potência máxima por 10 segundos, para a formação de catarata com dureza comparável à de um núcleo grau IV na Lens Opacities Classification System III. A extração da catarata foi realizada com o facoemulsificador Centurion® (Alcon Laboratories, Genebra, Suíça) e microscópio Leica M620. Todos os olhos foram submetidos a técnica de pre-chop, dividindo o núcleo em quatro partes. Em 30 olhos, após o pre-chop, foi feita a facoemulsificação dos quadrantes com o modo torsional e, nos outros 30 olhos, após o pre-chop, cada quadrante foi fragmentado com a pinça antes da facoemulsificação com o modo torsional. O aparelho foi calibrado para todos os olhos com os seguintes parâmetros: faco torsional linear 40%; pressão intraocular 65 mmHg; vácuo linear 600mmHg e fluxo de aspiração 40cc/minuto. Após cada procedimento, verificaram-se energia dissipada acumulada; média da amplitude do faco torsional; média equivalente do poder ultrassônico; líquido aspirado estimado; tempo total de ultrassom e tempo total de aspiração. A análise estatística foi realizada utilizando o teste de Kruskal-Wallis com o IBM Statistical Package for Social Sciences. Valor de p<0,05 foi considerado estatisticamente significante. Resultados: Houve redução estatisticamente significante em favor do uso da pinça fragmentadora de núcleo em todos os parâmetros, menos na média de amplitude do faco torsional. Conclusão: O uso da pinça fragmentadora de núcleo contribuiu para melhorar a eficácia do faco torsional em olhos de porco enucleados.


Assuntos
Animais , Instrumentos Cirúrgicos , Terapia por Ultrassom , Facoemulsificação/instrumentação , Facoemulsificação/métodos , Núcleo do Cristalino/cirurgia , Sonicação/efeitos adversos , Suínos , Catarata/classificação , Enucleação Ocular
2.
Arq. bras. oftalmol ; Arq. bras. oftalmol;84(3): 214-219, May-June 2021. graf
Artigo em Inglês | LILACS | ID: biblio-1248961

RESUMO

ABSTRACT Purpose: To evaluate the influence of pupil dynamics on the defocus profile and area-of-focus of eyes implanted with a diffractive multifocal intraocular lens (IOL). Methods: This prospective randomized trial was conducted at the Department of Ophthalmology, School of Medicine of Ribeirão Preto, University of São Paulo, Brazil. Thirty-eight patients were randomly assigned to receive the multifocal SN6AD1 (n=20) or the aspheric monofocal SN60WF (aIOL) (n=18) IOLs bilaterally. Dynamic pupillometry, visual acuity for distance and near, corrected and uncorrected, and a defocus profile were assessed postoperatively. The area-of-focus was calculated using an empirical polynomial model of the defocus profile. Results: Sixteen patients (32 eyes) in the multifocal SN6AD1 group and 17 patients (34 eyes) in the aspheric monofocal SN60WF group completed the 1-year follow-up. There were no significant between-group differences in monocular uncorrected distance or near visual acuity. The defocus profiles of the mfIOL group showed a double peak, whereas those of the aspheric monofocal SN60WF group showed only one peak, which is typical for a monofocal intraocular lens. The area-of-focus of the aIOL group (4.66 ± 1.51 logMARxD) was significantly different from that of the multifocal SN6AD1 (1.99 ± 1.31 logMARxD). Pupil size at maximum contraction after exposure to a flash of 30 cd/m2 for 1 second was significantly correlated with a better area-of-focus in the multifocal SN6AD1 group (r=0.54; p=0.0017), whereas this was not the case in the aspheric monofocal SN60WF group. Conclusion: These findings indicate that in eyes implanted with an multifocal SN6AD1, the smaller the pupil size, the better is the area-of-focus and hence the better is the visual performance. This correlation was not found for the aspheric monofocal SN60WF.(AU)


RESUMO Objetivo: Avaliar a influência da dinâmica pupilar na curva de desfoco de olhos implantados com lente intraoculares multifocais difrativas. Métodos: Estudo prospectivo e randomizado realizado na Faculdade de Medicina de Ribeirão Preto - Universidade de São Paulo - Departamento de Oftalmologia. Trinta e oito pacientes foram aleatoriamente designados para receber bilateralmente lentes intraoculares SN6AD1 (n=20) (mfIOL) ou SN60WF (n=18) (aIOL). Além da acuidade visual para longe e perto, corrigida e não corrigida, e curva de desfoco, foi ainda realizada pupilometria dinâmica. A área sob a curva de desfoco foi calculada usando um modelo polinomial empírico. Resultados: Um total de 16 e 17 pacientes (n=32 e 34 olhos) completaram 1 ano de seguimento nos grupos mfIOL e aIOL, respectivamente. Não houve diferenças significativas entre grupos para as acuidades visuais seja para longe ou perto. As curvas de desfoco do grupo mfIOL mostraram um pico duplo; enquanto o SN60WF mostrou apenas um pico, típico para uma lente intraoculares monofocal. A média da área sob a curva de desfoco do grupo aIOL foi (4,66 ± 1,51 logMAR.dp), e essa é estatisticamente significante diferente da métrica do grupo mfIOL (1,99 ± 1,31 logMAR.dp). A pupila na contração máxima após a exposição a um flash de 30 cd/m2 por 1 segundo foi significativamente correlacionada com uma melhor área de foco no grupo mfIOL (r=0,54; p=0,0017), essa relação não foi observada para o grupo aIOL. Conclusão: Estes dados indicam que quanto menor a pupila durante contração, melhor é a área sob a curva de desfoco e, portanto, o desempenho visual dos olhos implantados com essa mfIOL. Esta correlação não foi encontrada para lentes intraoculares monofocais.(AU)


Assuntos
Humanos , Extração de Catarata , Pupila/fisiologia , Facoemulsificação/instrumentação , Lentes Intraoculares Multifocais , Estudos Prospectivos
3.
Arq. bras. oftalmol ; Arq. bras. oftalmol;84(2): 158-162, Mar,-Apr. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1153111

RESUMO

ABSTRACT Purpose: The aim of this study was to evaluate the appropriate timing of capsular tension ring implantation in cases of zonular weakness due to pseudoexfoliation syndrome. Methods: This prospective, comparative study was performed at the Ophthalmology Department of Inonu University, Malatya, Turkey. There were 43 patients included in the study. Group 1 (16 patients) had early capsular tension ring implantation, and group 2 (27 patients) had late capsular tension ring implantation. Patients with pseudoexfoliation syndrome who underwent phacoemulsification surgery, posterior chamber intraocular lens implantation, and capsular tension ring implantation were included in the study. Intraoperative complications and difficulties with either capsular tension ring implantation or cortex removal were evaluated in each eye. Results: There was no significant difference between the groups in the difficulty of capsular tension ring implantation (p=0.124). The difficulty of cortex removal differed significantly between the groups (p=0.003). Intraoperative complications were observed in 3 patients in group 1 and 11 patients in group 2; the difference between the groups was not significant (p=0.18). Posterior capsule fluctuations were observed in 8 patients (29.5%) in group 2, which resulted in posterior capsule rupture in 2 patients. Conclusions: Cortex removal is more difficult with early capsular tension ring implantation, and posterior capsule fluctuations may cause problems with late capsular tension ring implantation. The surgeon must consider the risk-to-benefit ratio of early versus late insertion for the optimal timing of capsular tension ring implantation.


RESUMO Objetivo: Avaliar o momento apropriado para implante de anel de tensão capsular em casos de fraqueza zonular devida à síndrome pseudoesfoliativa. Métodos: Este foi um estudo prospectivo e comparativo realizado no Departamento de Oftalmologia da Universidade İnönü. Foram incluídos 43 pacientes, sendo 16 no grupo 1 e 27 no grupo 2. O grupo 1 era composto de pacientes que se submeteram ao implante precoce do anel de tensão capsular, enquanto no grupo 2 os pacientes tiveram implante tardio. Foram incluídos pacientes com síndrome pseudoesfoliativa submetidos à cirurgia de facoemulsificação e ao implante de lente intraocular na câmara posterior e anel de tensão capsular. Em cada olho, foram avaliadas as complicações intraoperatórias e as dificuldades tanto com a implantação do anel de tensão capsular quanto com a remoção do córtex. Resultados: Não houve diferença significativa entre os grupos quanto à dificuldade de implante do anel de tensão capsular (p=0,124). Ao se comparar as remoções do córtex, observou-se diferença significativa entre os grupos (p=0,003). Complicações intraoperatórias foram observadas em 3 pacientes do grupo 1 e 11 pacientes do grupo 2; porém, não houve diferença significativa entre os grupos (p=0,18). No grupo 2, observaram-se flutuações da cápsula posterior em 8 pacientes (29,5%), com ruptura da cápsula posterior em dois deles. Conclusões: A remoção do córtex é mais difícil no implante precoce do anel de tensão capsular e flutuações da cápsula posterior podem causar problemas no implante tardio do anel de tensão capsular. O cirurgião deve ponderar a relação risco/benefício do implante precoce e tardio ao avaliar o momento ideal para implante de anel de tensão capsular.


Assuntos
Humanos , Extração de Catarata/reabilitação , Facoemulsificação/instrumentação , Análise Custo-Eficiência , Estudos Prospectivos
4.
Arq. bras. oftalmol ; Arq. bras. oftalmol;79(2): 121-122, Mar.-Apr. 2016. graf
Artigo em Inglês | LILACS | ID: lil-782810

RESUMO

ABSTRACT We report the case of a 70-year-old female patient who developed corneal edema and iris discoloration following the inadvertent use of 1% methylene blue instead of 0.025% trypan blue to stain the anterior capsule during cataract phacoemulsification surgery. Copious irrigation was performed upon realization of incorrect dye use. Corneal edema and iris discoloration developed during the early postoperative period and persisted at 24-months follow-up. However, keratoplasty was not required. The intracameral use of 1% methylene blue has a cytotoxic effect on the corneal endothelium and iris epithelium. Copious irrigation for at least 30 min using an anterior chamber maintainer may improve outcomes.


RESUMO Paciente do sexo feminino com 70 anos de idade desenvolveu edema da córnea e descoloração da íris após o uso inadvertido de 1% de azul de metileno em vez de 0,025% de azul tripano para corar a cápsula anterior do cristalino durante a cirurgia de catarata por facoemulsificação. Foi realizada irrigação abundante quando detectou-se que o corante incorreto tinha sido usado. Edema da córnea e descoloração íris que ocorreu no período pós-operatório precoce persistiu durante 24 meses de seguimento; no entanto, a ceratoplastia não foi necessária. O uso intracameral de 1% de azul de metileno tem efeitos citotóxicos sobre o endotélio da córnea e epitélio da íris. A irrigação abundante durante pelo menos 30 minutos, utilizando um mantenedor de câmara anterior pode resultar em um prognóstico melhor.


Assuntos
Humanos , Feminino , Idoso , Facoemulsificação/efeitos adversos , Erros Médicos/efeitos adversos , Corantes/efeitos adversos , Azul de Metileno/efeitos adversos , Acuidade Visual , Edema da Córnea/etiologia , Iris/efeitos dos fármacos , Facoemulsificação/instrumentação , Corantes/administração & dosagem , Corantes/farmacologia , Injeções , Irrigação Terapêutica/métodos , Azul de Metileno/administração & dosagem , Azul de Metileno/farmacologia
5.
Arq. bras. oftalmol ; Arq. bras. oftalmol;78(1): 19-22, Jan-Feb/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-741162

RESUMO

Purpose: To compare the efficiency of surgical procedures using three phaco tip designs in torsional phacoemulsification using the bevel-down technique. Methods: In this prospective, comparative, masked study, patients were randomly assigned to have torsional coaxial microincision cataract surgery using the mini-flared 45-degree Kelman tip, reversed mini-flared 30-degree Kelman tip, or Sidewinder 30-degree Kelman tip. Clinical measurements included preoperative and 3-month postoperative corrected distance visual acuity (CDVA), endothelial cell counts (ECC), and preoperative and 1-day postoperative central corneal thickness (CCT). Intraoperative measurements included phaco time, torsional time, aspiration time, case time, cumulative dissipated energy (CDE), and balanced salt solution volume (BSS). Results: The study evaluated 150 eyes of 150 patients. Intraoperatively, there was no statistically significant difference in cumulative dissipated energy, case time, torsional time, and aspiration time between the three tip configurations. However, less phaco time was used with the mini-flared 45-degree Kelman tip (p=0.02) than that with the Sidewinder 30-degree Kelman tip or reversed mini-flared 30-degree Kelman tip. The mini-flared 45-degree Kelman tip and the reversed mini-flared 30-degree Kelman tip required significantly less balanced salt solution volume than that required by the Sidewinder 30-degree Kelman tip (p=0.009). There was no statistically significant difference in corrected distance visual acuity and endothelial cell counts between tips 3 months postoperatively (p>0.05). Conclusion: All three tips were effective with no intraoperative complications. When using torsional phacoemulsification through microincisions and the prefracture technique with the bevel-down technique, the mini-flared 45-degree Kelman tip required a lower mean phaco time than the reversed mini-flared 30-degree Kelman tip and the Sidewinder 30-degree Kelman tip. .


Objetivo: Comparar a eficácia cirúrgica da facoemulsificação com tecnologia torcional utilizando 3 modelos diferentes de ponteiras. Métodos: Neste estudo prospectivo, randomizado, mascarado, os pacientes foram aleatoriamente distribuídos para serem submetidos a cirurgia de facoemulsificação coaxial torcional utilizando a ponteira Kelman mini-flared de 45 graus, ou Kelman reversed mini-flared de 30 graus ou Kelman Sidewinder de 30 graus. Os parâmetros avaliados incluíram: acuidade visual com correção (AVCC) para longe; contagem de células endoteliais (CCE) pré-operatória e pós-operatória, ao final de 3 meses; espessura corneana central (ECC) pré-operatória e no primeiro dia pós-operatório. Medidas intraoperatórias incluíram tempo de facoemulsificação, tempo de energia torcional, tempo da aspiração, tempo cirúrgico, energia dissipada acumulada (CDE) e volume de solução salina balanceada (BSS). Resultados: Este estudo avaliou 150 olhos de 150 pacientes. No intraoperatório, não foram observadas diferenças significativas na energia dissipada acumulada, tempo de facoemulsificação, tempo de energia torcional, e tempo de aspiração entre os 3 modelos de ponteira. No entanto, foi utilizando menos tempo de faco com a ponteira Kelman mini-flared de 45 graus (p=0,02) quando comparado às ponteiras Kelman Sidewinder de 30 graus e reversa mini-flared de 30 graus. A ponteira Kelman mini-flared de 45 graus e a reversa mini-flared de 30 graus utilizaram menos solução salina balanceada quando comparado à ponteira Sidewinder de 30 graus (p=0,009). Não foram observadas diferenças significativas na acuidade visual com correção, contagem de células endoteliais e espessura corneana central entre as diferentes ponteiras ao final do estudo (p=0,05). Conclusão: As 3 ponteiras foram eficazes e não apresentaram complicacões intraoperatórias. Quando foi utilizando o faco torcional através de microincisão com a técnica da pré-fratura, a ponteira Kelman mini-flared ...


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Córnea/cirurgia , Facoemulsificação/instrumentação , Contagem de Células , Desenho de Equipamento , Endotélio Corneano/citologia , Período Intraoperatório , Duração da Cirurgia , Período Pós-Operatório , Cuidados Pré-Operatórios , Estudos Prospectivos , Facoemulsificação/métodos , Método Simples-Cego , Resultado do Tratamento , Acuidade Visual/fisiologia
7.
Clinics ; Clinics;67(9): 1059-1062, Sept. 2012. tab
Artigo em Inglês | LILACS | ID: lil-649386

RESUMO

OBJECTIVE: This study sought to compare the effects and outcomes of two ophthalmic viscosurgical devices, 1.6% hyaluronic acid/4.0% chondroitin sulfate and 2.0% hydroxypropylmethylcellulose, during phacoemulsification. METHODS: This prospective, randomized clinical trial comprised 78 eyes (39 patients) that received phacoemulsification performed by the same surgeon using a standardized technique. Patients were randomly assigned to receive either 1.6% hyaluronic acid/4.0% chondroitin sulfate or 2.0% hydroxypropylmethylcellulose on the first eye. The other eye was treated later and received the other viscoelastic agent. Preoperative and postoperative examinations (5, 24 and 48 hours; 7 and 14 days; 3 and 6 months) included measurements of the total volume of the ophthalmic viscosurgical device, ultrasound and washout times to completely remove the ophthalmic viscosurgical device, intraocular pressure, central corneal thickness and best-corrected visual acuity. The corneal endothelial cell count was measured at baseline and at six months postoperatively. ClinicalTrials.gov: NCT01387620. RESULTS: There were no statistically significant differences between groups in terms of cataract density or ultrasound time. However, it took longer to remove 2.0% hydroxypropylmethylcellulose than 1.6% hyaluronic acid/ 4.0% chondroitin sulfate, and the amount of viscoelastic material used was greater in the 2.0% hydroxypropylmethylcellulose group. In addition, the best-corrected visual acuity was significantly better in the hyaluronic acid/ chondroitin sulfate group, but this preferable outcome was only observed at 24 hours after the operation. There were no statistically significant differences between the two ophthalmic viscosurgical devices regarding the central corneal thickness or intraocular pressure measurements at any point in time. The corneal endothelial cell count was significantly higher in the hyaluronic acid/chondroitin sulfate group. CONCLUSION: The ophthalmic viscosurgical device consisting of 1.6% hyaluronic acid/4.0% chondroitin sulfate was more efficient during phacoemulsification and was easier to remove after IOL implantation than 2.0% hydroxypropylmethylcellulose. In addition, the corneal endothelial cell count was significantly higher following the use of hyaluronic acid/chondroitin sulfate than with hydroxypropylmethylcellulose, which promoted an improved level of corneal endothelium protection.


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Metilcelulose/análogos & derivados , Soluções Oftálmicas/administração & dosagem , Facoemulsificação/métodos , Sulfatos de Condroitina/administração & dosagem , Métodos Epidemiológicos , Ácido Hialurônico/administração & dosagem , Pressão Intraocular , Metilcelulose/administração & dosagem , Período Perioperatório , Facoemulsificação/instrumentação , Fatores de Tempo , Resultado do Tratamento , Acuidade Visual , Viscossuplementos/administração & dosagem
8.
Arq. bras. oftalmol ; Arq. bras. oftalmol;75(3): 174-177, maio-jun. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-644443

RESUMO

PURPOSE: To determine the incidence of Piry virus contamination among surgical instruments used with disposable accessories for phacoemulsification during sequential surgeries. METHODS: An experimental model was created with 4 pigs' eyes that were contaminated with Piry virus and 4 pigs' eyes that were not contaminated. Phacoemulsification was performed on the eyes, alternating between the contaminated and non-contaminated eyes. From one surgery to another, the operating fields, gloves, scalpel, tweezers, needles, syringes, tips and bag collector from the phacoemulsification machine were exchanged; only the hand piece and the irrigation and aspiration systems were maintained. RESULTS: In the collector bag, three samples from the contaminated eyes (3/4) were positive, and two samples from the non-contaminated (2/4) eyes were also positive; at the tip, one sample from the contaminated eyes (1/4) and two samples of the non-contaminated eyes (2/4) yielded positive results. In the irrigation system, one sample from a non-contaminated eye (1/4) was positive, and in the aspiration system, two samples from contaminated eyes (2/4) and two samples from non-contaminated eyes (2/4) were positive. In the gloves, the samples were positive in two samples from the non-contaminated eyes (2/4) and in two samples from the contaminated eyes (2/4). In the scalpel samples, three contaminated eyes (3/4) and none of the non-contaminated eyes (0/4) were positive; finally, two samples from the anterior chambers of the non-contaminated eyes gathered after surgery were positive. CONCLUSIONS: In two non-contaminated eyes, the presence of genetic material was detected after phacoemulsification surgery, demonstrating that the transmission of the genetic material of the Piry virus occurred at some point during the surgery on these non-contaminated eyes when the hand piece and irrigation and aspiration systems were reused between surgeries.


OBJETIVO: Determinar a incidência de contaminação com o vírus Piry entre os instrumentos cirúrgicos e acessórios usados durante cirurgias sequenciais de facoemulsificação. MÉTODOS: Um modelo experimental foi realizado com quatro olhos de porcos que foram contaminados com o vírus Piry e quatro olhos de porcos não contaminados. A facoemulsificação foi realizada alternando um olho contaminado para outro olho não contaminado. Entre as cirurgias, os campos de operação, luvas, bisturi, pinças, agulhas, seringas, pontas e bolsa coletora foram trocados, mantendo somente a caneta e os sistemas de irrigação e aspiração do facoemulsificador. RESULTADOS: No saco coletor, três amostras de olhos contaminados (3/4) foram positivos, e duas amostras de olhos não contaminados (2/4) também foram positivos; na ponta do facoemulsificador, uma amostra dos olhos contaminados (1/4) e duas amostras de olhos não contaminados (2/4) apresentaram resultados positivos. No sistema de irrigação, uma amostra de um olho não contaminado (1/4) foi positivo, e no sistema de aspiração, duas amostras de olhos contaminados (2/4) e duas amostras de olhos não contaminados (2/4) foram positivos. Nas luvas, as amostras foram positivos em dois olhos não contaminados (2/4) e duas amostras de olhos contaminados (2/4). Nas amostras de bisturi, três olhos contaminados (3/4) e nenhum dos olhos não contaminados (0/4) foram positivos e, finalmente, duas amostras da câmara anterior dos olhos não contaminados (2/4) reunidos após a cirurgia foram positivos. CONCLUSÕES: Em dois olhos não contaminados, a presença de material genético foi detectado após a cirurgia de facoemulsificação, demonstrando que a transmissão do material genético do vírus Piry ocorreu em algum ponto durante a cirurgia para estes olhos não contaminados, quando a caneta de facoemulsificação e o sistema de irrigação e aspiração foram reutilizados entre as cirurgias.


Assuntos
Animais , Modelos Animais de Doenças , Contaminação de Equipamentos , Infecções Oculares Virais/virologia , Facoemulsificação/instrumentação , Vesiculovirus/genética , Soluções Oftálmicas , Facoemulsificação/efeitos adversos , RNA Viral , Suínos , Irrigação Terapêutica/métodos
9.
Korean J. Ophthalmol ; Korean J. Ophthalmol;: 15-21, 2011.
Artigo em Inglês | WPRIM | ID: wpr-121943

RESUMO

PURPOSE: To compare surgical results between conventional intraocular lens (IOL) implantation using an ophthalmic viscosurgical device (OVD) and IOL implantation using a balanced salt solution (BSS) after irrigation/aspiration (I/A) of the lens cortex. METHODS: A randomized prospective study was conducted on 62 patients who underwent cataract surgery. Following completion of conventional I/A of the lens cortex, we divided patients into two groups according to whether or not BSS was used. In group A (n = 31), the anterior chamber and the capsular bag were completely filled with an OVD before IOL implantation. On the other hand, in group B (n = 31), BSS was irrigated into the anterior chamber through a previous side port during IOL implantation. Surgical results were compared between the two groups. RESULTS: In both groups, IOP peaked six hours after surgery. The occurrence of an IOP spike by postoperative day one was observed in six cases (6 / 31) in group A and in no cases (0 / 31) in group B, a difference that was statistically significant (p = 0.024). The values of endothelial cell density, central corneal thickness, anterior chamber inflammation, myopic shift, and posterior capsule opacification were not significantly different between the two groups. CONCLUSIONS: Compared with the use of OVD for IOL implantation, use of BSS during IOL implantation resulted in reductions in postoperative IOP spike and OVD removal time.


Assuntos
Idoso , Humanos , Pessoa de Meia-Idade , Câmara Anterior/cirurgia , Extração de Catarata , Remoção de Dispositivo , Pressão Intraocular , Implante de Lente Intraocular/métodos , Facoemulsificação/instrumentação , Estudos Prospectivos , Irrigação Terapêutica/métodos
10.
Arq. bras. oftalmol ; Arq. bras. oftalmol;73(6): 508-510, nov.-dez. 2010. ilus, tab
Artigo em Inglês | LILACS | ID: lil-572214

RESUMO

Purpose: To compare the extent of corneal endothelial (CE) cell loss changes in two groups of eyes submitted to phacoemulsification, with the conventional bevel-up tip position in one eye and with the bevel-down tip position in the fellow eye. Methods: This prospective clinical trial comprised 25 patients with bilateral cataracts subjected to lens removal by phacoemulsification with the conventional bevel-up tip position (GI) in one eye and with the bevel-down tip position (GII) in the fellow eye. The nuclei were graded clinically on the basis of hardness. The endothelial cell count (ECC) was evaluated preoperatively and 1, 3 and 6 months postoperatively. Total surgical time, effective ultrasound time and complications were also compared between the groups. Statistical analysis was performed by the Tukey Studentized Range test, with repeated measures for the selected periods. For the other parameters a paired t test was used. Data are presented as mean ± SD, with the level of significance set at p<0.05. Results: The mean effective ultrasound time was 8.08 ± 6.75 seconds in group I and 7.00 ± 5.75 seconds in GII (P=0.1792) and total surgical time was 10.01 ± 2.46 minutes in GI and 9.86 ± 2.17 minutes in GII (p=0.6267), respectively. The paired t test revealed no statistical differences between the groups. Complications were also similar between the groups. Mean endothelial cell count loss was 6.9 percent in GI and 2.8 percent in GII at one month; 6.9 percent in GI and 3.6 percent in GII at three months and 11.9 percent in GI and 7.6 percent in GII at six months postoperatively. Comparison of endothelial cell count (ECC) showed a statistically significant difference between the groups during the postoperative period. Conclusion: The conventional bevel-up tip position has a negative effect on corneal endothelial cells compared with the bevel-down position. Since the results of other surgical parameters were similar, the bevel-down tip position should be considered as an option in non-complicated phacoemulsification.


Objetivo: Comparamos duas técnicas de cirurgia de catarata. A técnica cirúrgica tradicional, em que direciona a abertura do bisel da ponteira de facoemulsificação para o endotélio corneano, com a técnica oposta, onde a reversão da posição de abertura permite o direcionamento da energia de emulsificação para o núcleo. Estudamos seus efeitos sobre a córnea e possíveis complicações. Métodos: O trabalho foi divido em quatro tempos: pré-operatório e após 30, 60 e 180 dias. Os pacientes foram divididos em dois grupos: o grupo 1, tratado com a técnica cirúrgica tradicional, com a abertura da ponteira direcionada para o endotélio, e grupo 2, que recebeu tratamento com técnica oposta, direcionada diretamente para o núcleo ou para os fragmentos nucleares. Após as cirurgias, foram estudados: perda endotelial após 30, 60 e 180 dias, tempo total de cirurgia e tempo efetivo de faco. Resultados: Os resultados intraoperatórios apresentaram o tempo efetivo de facoemulsificação no GI teve média de 8,08 segundos (DP=6,75) e no GII, média de 7,0 segundos (P=0,1792) e o tempo total de cirurgia de 10,01 ± 2,46 minutos no GI e 9,86 ± 2,17 minutos no GII (p=0,6267) respectivamente. O teste pareado não revelou diferença estatística entre os grupos. As complicações foram similares nos dois grupos. A média de perda de células endoteliais foi de 6,9 por cento no GI e2,8 por cento in GII com um mês; 6,9 por cento no GI e 3,6 por centonoGIIcom trêsmeses e 11,9 por cento no GI e 7,6 por cento no GII com seis meses de pós-operatório. Conclusão: Concluímos que a variação da manobra apresentada é segura e pode minimizar perdas no endotélio corneano, podendo ser uma opção na cirurgia da catarata, de acordo com as preferências pessoais do cirurgião.


Assuntos
Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Endotélio Corneano/cirurgia , Facoemulsificação/métodos , Contagem de Células , Seguimentos , Período Pós-Operatório , Estudos Prospectivos , Facoemulsificação/efeitos adversos , Facoemulsificação/instrumentação , Fatores de Tempo , Resultado do Tratamento
11.
Rev. bras. anestesiol ; Rev. bras. anestesiol;58(6): 569-581, nov.-dez. 2008. ilus, tab
Artigo em Inglês, Português | LILACS | ID: lil-497045

RESUMO

JUSTIFICATIVA E OBJETIVOS: Comparar a qualidade e a segurança da anestesia retrobulbar (ARB) para tratamento de catarata por facoemulsificação utilizando agulhas de dois diferentes tamanhos: 25 x 0,70 mm ou 20 x 0,55 mm. MÉTODOS: Seleção prospectiva de candidatos a bloqueio oftálmico para tratamento de catarata por facoemulsificação. Após sedação e monitorização padronizada, foi realizada anestesia retrobulbar (ARB) em punção única ínfero-lateral com 4 mL de ropivacaína 1 por cento, contendo hialuronidase. No Grupo I (GI) a agulha utilizada foi de 25 x 0,70 mm e no Grupo II (GII), de 20 x 0,55 mm. Em um paciente de cada grupo foram realizadas tomografias computadorizadas no momento da realização do bloqueio oftálmico e após cinco minutos da administração da solução anestésica com contraste radiológico. A mobilidade ocular foi avaliada após três, cinco e dez minutos. Por meio de um questionário padronizado, foram comparadas a incidência de complicações entre os grupos, a satisfação dos pacientes e cirurgiões. RESULTADOS: Foram avaliados 54 pacientes adultos (27 por grupo). Nenhum paciente relatou dor ou percepção luminosa intra-operatória. O procedimento anestésico foi considerado muito bom (MB) ou excelente (E) em 96,30 por cento dos casos nos dois grupos. A mesma avaliação foi feita por 100 por cento dos pacientes. Não houve diferença na necessidade de repetição do bloqueio entre os grupos (p = 1,0). O GI apresentou menor mobilidade ocular aos 3 minutos (p = 0,03). Observou-se o posicionamento da agulha em posição retrobulbar intraconal em ambos os grupos. A dispersão anestésica foi similar entre os grupos aos 5 minutos. CONCLUSÃO: A ARB realizada com a agulha de 20 × 0,55 mm, em punção única ínfero-lateral, utilizando baixas doses de anestésicos, se apresenta como uma opção eficaz e segura para tratamento de catarata por facoemulsificação.


BACKGROUND AND OBJECTIVES: The objective of this study was to compare the quality and safety of retrobulbar block for the treatment of cataracts by phacoemulsification using needles of different sizes: 27 × 0.70 mm and 20 × 0.55 mm. METHODS: Candidates for ophthalmic block for the treatment of cataracts by phacoemulsification were selected prospectively. After sedation and standardized monitoring, a retrobulbar block with 4 mL of 1 percent ropivacaine containing hyaluronidase was performed with a single inferolateral puncture. In Group I (GI), the 25 × 0.70 mm needle was used, while in Group II (GII) a 20 × 0.55 mm needle was used. All patients had a CT scan at the time of the blockade and five minutes after the administration of the anesthetic solution with radiologic contrast. Ocular mobility was assessed after three, five, and ten minutes. The incidence of complications in both groups and the satisfaction of patients and surgeons were compared by applying a standardized questionnaire. RESULTS: Fifty-four adult patients were evaluated (27 per group). Patients did not complain of intraoperative pain or perception of light. The anesthetic procedure was considered very good (VG) or excellent (E) in 96.3 percent of the cases in both groups. All patients were subjected to the same assessment. The need of block repetition between both groups did not differ (p = 1.0). Patients in GI showed decreased ocular mobility at 3 minutes (p = 0.03). The intraconal retrobulbar placement of the needle was observed on both groups. Anesthetic dispersion at 5 minutes was similar in the two groups. CONCLUSIONS: Retrobulbar block with a single inferolateral puncture with a 20 × 0.55 mm needle, using low doses of anesthetics, is an effective and safe option for the treatment of cataracts by phacoemulsification.


JUSTIFICATIVA Y OBJETIVOS: Comparar la calidad y la seguridad de la anestesia retrobulbar (ARB) para tratamiento de catarata por facoemulsificación, utilizando agujas de dos diferentes tamaños: 25 x 0,70 mm o de 20 x 0,55 mm. MÉTODOS: Selección prospectiva de candidatos a bloqueo oftálmico para tratamiento de catarata por facoemulsificación. Después de la sedación y monitoreo estandarizado, se realizó anestesia retrobulbar (ARB) en punción única ínfero-lateral con 4 mL de ropivacaina 1 por ciento, con hialuronidasa. En el Grupo I (GI), la aguja utilizada fue de 25 x 0,70 mm y en el Grupo II (GII), de 20 x 0,55 mm. En un paciente de cada grupo fueron realizadas tomografías computadorizadas al momento de la realización del bloqueo oftálmico y después de cinco minutos de la administración de la solución anestésica con contraste radiológico. La movilidad ocular se evaluó después de tres, cinco y diez minutos. A través de un cuestionario estandarizado, se compararon la incidencia de complicaciones entre los grupos, y la satisfacción de los pacientes y de los cirujanos. RESULTADOS: Fueron evaluados 54 pacientes adultos (27 por grupo). Ningún paciente relató dolor o percepción luminosa intraoperatoria. El procedimiento anestésico fue considerado muy bueno (MB) o excelente (E) en un 96,30 por ciento de los casos en los dos grupos. La misma evaluación se hizo en un 100 por ciento de los pacientes. No hubo diferencia en la necesidad de repetición del bloqueo entre los grupos (p = 1,0). El GI presentó menor movilidad ocular a los 3 minutos (p = 0,03). Se observó el posicionamiento de la aguja en posición retrobulbar intraconal en los dos grupos. La dispersión anestésica fue similar entre los grupos a los 5 minutos. CONCLUSIÓN: La ARB realizada con la aguja de 20 x 0,55mm, en punción única ínfero-lateral, utilizando bajas dosis de anestésicos, se presenta como una opción eficaz y segura para el tratamiento de catarata por facoemulsificación.


Assuntos
Humanos , Agulhas/normas , Anestesia por Condução/métodos , Facoemulsificação/instrumentação , Extração de Catarata
12.
Artigo em Inglês | IMSEAR | ID: sea-44172

RESUMO

BACKGROUND: Intra-ocular lens (IOLs) is the most commonly use organ substitute worldwide. Question of different type of IOLs which would offer different post operative visual acuity (VA) has been asked. OBJECTIVES: To compare the pre-operative and post operative visual acuity (VA) of cataract patients operated-patient and the use of non foldable and foldable IOLs in different age groups. METHOD: Retrospective study of post operative VA of cataract patients-operated from Priest, Lerdsin Hospital in Bangkok and Lampang Hospital in northern part of Thailand. Methods to operate and type of IOLs implantation were recorded. The cases with pre-operative and intra-operative complications were excluded. RESULTS: Post operative VA of cataract patients was better than pre-operation VA with statistically significant at p-value less than 0.05 and the results persisted for every age group. With phacoemulsification (PE) techniques, non-foldable IOLs offered better post operative VA than foldable IOLs in every age group except in age group of less than 40 and age group over 59 that showed statistically significant different at p-value less than 0.05. CONCLUSION: Due to the nature of retrospective study, the cause of poor post operative VA was due to astigmatism which the pre-operative astigmatism were not recorded to fulfill complete analysis.


Assuntos
Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Astigmatismo , Feminino , Humanos , Implante de Lente Intraocular/métodos , Masculino , Pessoa de Meia-Idade , Facoemulsificação/instrumentação , Qualidade de Vida , Estudos Retrospectivos , Tailândia , Acuidade Visual
14.
Korean J. Ophthalmol ; Korean J. Ophthalmol;: 155-158, 2008.
Artigo em Inglês | WPRIM | ID: wpr-41305

RESUMO

PURPOSE: To investigate the effect of lens density on liquefaction time by using liquefaction device (AquaLase(R), Alcon Laboratories, TX, U.S.A.). METHODS: Cataract surgery using AquaLase(R) was performed on 47 eyes. With a Scheimpflug camera, the density and thickness of lens were measured in eye of each patient preoperatively. During surgery, liquefaction time and total number of pulses were recorded. The correlation of both density and thickness of lens with liquefaction time and total number of pulses was analyzed. RESULTS: The mean density of anterior cortex, nucleus, and posterior cortex was 112.45+/-42.1 computer compatible tapes (CCT), 76.5+/-22.7 CCT, and 70.9+/-52.2 CCT, respectively. The mean thickness was 0.97+/-0.30 mm, 2.76+/-0.54 mm, and 0.81+/-0.24 mm, respectively. The mean liquefaction time was 174.8+/-108.2 seconds. The mean total number of pulses was 4799+/-3007.There was no significant difference between the density of each area of lens (anterior cortex, nucleus, posterior cortex, and total lens) and liquefaction time (p>0.05), and between the thickness of each area of lens and liquefaction time (p>0.05). There was no significant difference between the density of each area of lens and total number of pulses (p>0.05), and between the thickness of each area of lens and total number of pulses (p>0.05). CONCLUSIONS: When extraction of soft to moderate density cataract was performed with AquaLase(R), liquefaction time and total number of pulse did not correlate to the density and thickness of lens.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Catarata/patologia , Cristalino/patologia , Facoemulsificação/instrumentação , Fotografação , Fatores de Tempo
15.
Arq. bras. oftalmol ; Arq. bras. oftalmol;70(5): 746-751, set.-out. 2007. ilus, tab
Artigo em Português | LILACS | ID: lil-470088

RESUMO

OBJETIVO: Avaliar o comportamento do anel modificado de tensão capsular em cataratas traumáticas com subluxação, analisando a acuidade visual, centração do saco capsular, pseudofacodonese, seguimento pós-operatório, e complicações intra e pós-operatórias. LOCAL: Cincinnati Eye Institute, Cincinnati, Ohio, USA. MÉTODOS: Vinte e dois olhos de 22 pacientes com perda traumática de suporte zonular foram submetidos à facoemulsificação utilizando lente intra-ocular de câmara posterior e o implante do anel capsular modificado. O exame pré-operatório incluiu melhor acuidade visual corrigida (MAVC), a presença ou ausência de facodonese, descentração do cristalino e prolapso vítreo. A avaliação pós-operatória incluiu MAVC, presença de pseudofacodonese, centração do implante, necessidade de vitrectomia e outras complicações. RESULTADOS: Vinte e um olhos (95,45 por cento) tiveram melhora da MAVC. O exame pré-operatório revelou facodonese em 11 olhos (50 por cento) e nenhum olho apresentou pseudofacodonese. No exame pré-operatório, a descentração sintomática estava presente em 10 olhos (45,45 por cento). Todos os olhos apresentaram centração do complexo saco capsular/LIO no pós-operatório. Prolapso vítreo foi diagnosticado antes da cirurgia em 9 olhos (40,90 por cento) e a vitrectomia foi necessária em 11 olhos (50 por cento). CONCLUSÃO: O uso do anel modificado de tensão capsular resultou em boa centração do complexo saco capsular/lente intra-ocular nos olhos estudados com catarata traumática e perda de suporte zonular.


PURPOSE: To evaluate the behavior of the modified capsular tension ring (MCTR) in traumatic subluxated cataracts analyzing the visual acuity, centration of the capsular bag, pseudophacodonesis, postoperative follow-up and intra- and postoperative complications. SETTING: Cincinnati Eye Institute, Cincinnati, Ohio, USA. METHODS: Twenty-two eyes of 22 patients with traumatic loss of zonular support had phacoemulsification using PCIOL and MCTR implantation. The preoperative examination included best correct visual acuity (BCVA) and the presence or absence of phacodonesis, lens decentration and vitreous prolapse. The postoperative evaluation included BCVA, the presence of pseudophacodonesis, PCIOL centration, necessity of vitrectomy and other complications. RESULTS: 21 eyes (95.45 percent) had an improvement in BCVA. The preoperative examination disclosed phacodonesis in 11 eyes (50 percent) and no eye presented pseudophacodonesis in the postoperative period. Preoperatively, symptomatic decentration was presented by 10 eyes (45.45 percent) and 22 eyes (100 percent) had no decentration after surgery. The preoperative examination revealed vitreous prolapse in the anterior chamber in 9 eyes (40.90 percent). Vitrectomy was required in 11 eyes (50 percent). CONCLUSIONS: The use of the MCTR resulted in a good centration of the capsular bag and the PC IOL in 22 eyes with traumatic cataract and loss of zonular support.


Assuntos
Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Traumatismos Oculares/complicações , Cápsula do Cristalino/fisiopatologia , Cápsula do Cristalino/cirurgia , Subluxação do Cristalino/cirurgia , Facoemulsificação/instrumentação , Seguimentos , Complicações Intraoperatórias , Implante de Lente Intraocular/efeitos adversos , Implante de Lente Intraocular/instrumentação , Subluxação do Cristalino/etiologia , Subluxação do Cristalino/fisiopatologia , Cuidados Pré-Operatórios , Facoemulsificação/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual/fisiologia
16.
Indian J Ophthalmol ; 2006 Dec; 54(4): 267-9
Artigo em Inglês | IMSEAR | ID: sea-70275

RESUMO

We report an unusual case of angle closure glaucoma in a 78-year-old highly myopic female patient. The patient did not show any preoperative signs of subluxation of lens. However, the capsular bag was noted to be unstable during surgery. The patient was managed with phacoemulsification of lens using a novel method of iris hooks for stabilization of capsular bag during surgery.


Assuntos
Idoso , Desenho de Equipamento , Feminino , Seguimentos , Glaucoma de Ângulo Fechado/etiologia , Humanos , Pressão Intraocular , Iris/cirurgia , Cápsula do Cristalino/cirurgia , Subluxação do Cristalino/complicações , Miopia/complicações , Facoemulsificação/instrumentação , Refração Ocular , Índice de Gravidade de Doença , Acuidade Visual
17.
Arq. bras. oftalmol ; Arq. bras. oftalmol;69(3): 371-375, maio-jun. 2006. ilus, tab
Artigo em Português | LILACS | ID: lil-433801

RESUMO

OBJETIVO: Avaliar prospectivamente os resultados das lentes intra-oculares de polímeros expansíveis implantadas em pacientes submetidos à facoemulsificação, quanto à incidência de opacificação de cápsula posterior, levando em consideração a biocompatibilidade das lentes expansíveis. MÉTODOS: O grupo de estudo foi composto por 830 pacientes, 1.200 olhos, que foram submetidos a facoemulsificação, utilizando a mesma técnica, variando-se apenas o diâmetro da capsulorrexe, pelo mesmo cirurgião, no período de 1998 a 2002, com implante de lente intra-ocular hidrofílica expansível. O acompanhamento médio foi de 2,4 anos, variando de seis meses a quatro anos. RESULTADOS: O número total de opacificação de cápsula posterior foi de 54 casos. CONCLUSÃO: A incidência de opacificação de cápsula posterior encontrada no grupo foi de 4,6 por cento.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Catarata/etiologia , Cápsula do Cristalino/patologia , Implante de Lente Intraocular/efeitos adversos , Facoemulsificação/efeitos adversos , Resinas Acrílicas , Materiais Biocompatíveis , Catarata/epidemiologia , Seguimentos , Incidência , Implante de Lente Intraocular/instrumentação , Estudos Prospectivos , Facoemulsificação/instrumentação , Resultado do Tratamento
18.
Arq. bras. oftalmol ; Arq. bras. oftalmol;69(3): 389-393, maio-jun. 2006. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-433804

RESUMO

OBJETIVOS: As técnicas e resultados da cirurgia de catarata melhoraram drasticamente com o avanço tecnológico. Um dos motivos para melhoria seria a menor utilização de ultra-som com novos aparelhos de facoemulsificação. O objetivo deste estudo é confirmar na prática a vantagem teórica da caneta NeoSoniX TM. MÉTODOS: Foi realizada uma análise na qual os autores compararam resultados dos parâmetros registrados pelo aparelho de facoemulsificação Legacy durante 300 cirurgias de catarata realizadas com caneta de ultra-som (handpiece) convencional e 100 com a caneta NeoSoniX TM. Todas as cirurgias foram realizadas pelo mesmo cirurgião, com a mesma técnica cirúrgica. A escolha da "handpiece" foi aleatória, sendo comparadas, em relação ao grau de dureza das cataratas, os parâmetros de tempo do ultra-som, quantidade de solução salina balanceada e porcentagem de "average power" utilizadas durante as cirurgias. RESULTADOS: Foi realizada análise retrospectiva numa série cronológica de casos, mostrando que em qualquer que seja o grau de dureza da catarata, o tempo de utilização do ultra-som com a caneta NeoSoniX foi inferior ao da caneta convencional (p<0,000001). O volume de solução salina balanceada utilizado durante as cirurgias foi menor a favor da tecnologia NeoSoniX (p<0,000001). Em relação à porcentagem de potência do ultra-som utilizada com as diferentes tecnologias, encontrou-se valor inferior no grupo da caneta NeoSoniX (p<0,000001). CONCLUSÕES: Houve superioridade significativa no uso da caneta NeoSoniX comparada à caneta convencional do aparelho Legacy nas cirurgias de catarata, independente do seu grau.


Assuntos
Humanos , Facoemulsificação/instrumentação , Facoemulsificação/métodos , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento
19.
Arq. bras. oftalmol ; Arq. bras. oftalmol;67(2): 259-265, mar.-abr. 2004. tab
Artigo em Português | LILACS | ID: lil-362254

RESUMO

OBJETIVOS: Introduzir metodologia para Implantação de um programa de manutenção preventiva pleno, para os usuários do aparelho de facoemulsificação. MÉTODOS: Para implantação de um programa de manutenção de aparelho de facoemulsificação foi adotado como modelo de equipamento o Legacy 20000Õ (Alcon). Foi utilizado o manual de operações como busca preliminar, a fim de se quantificar a probalidade de falha ou quebra do equipamento. Verificaram-se as condições de manutenção do Legacy 20000Õ em alguns hospitais de São Paulo por meio de visita aos engenheiros clínicos destas instituições e o levantamento das requisições de serviço de manutenção. Pesquisou-se a opinião dos cirurgiões do Setor de Catarata da Universidade Federal de São Paulo a respeito do funcionamento do aparelho, para se detectar as principais falhas ou defeitos do Legacy 20000Õ, sob o ponto de vista do usuário. Após os resultados da pesquisa nos hospitais e com os cirurgiões, foi sugerido um Manual de Manutenção preventiva para o Legacy 20000Õ utilizando-se as ferramentas da manutenção preventiva. RESULTADOS: A análise referente as "mensagens de erro" do manual de operações demonstrou que a maioria dos potenciais problemas e ações corretivas a serem realizadas são por problemas de conexão ou fixação dos terminais. Foi no Hospital São Paulo, onde havia um aparelho comprado e onde a sua utilização foi maior, que se verificaram os principais defeitos do Legacy 20000Õ relacionados principalmente a quebra da caneta de ultra-som, quebra dos componentes eletrônicos e mecânicos, falhas no "setup", problemas de calibração, vácuo e aspiração. A pesquisa com os cirurgiões de catarata da Universidade Federal de São Paulo demonstrou falta de conhecimento técnico devido ao desconhecimento do manual de operações e ausência de treinamento formal com relação aos recursos do aparelho. CONCLUSÕES: Não existe programa de manutenção pleno e preditivo desenvolvido para o Legacy 20000Õ nos hospitais pesquisados, somente manutenção corretiva. Os itens do manual de manutenção preventiva sugerido para o Legacy 20000Õ foram elaborados a partir dos resultados da pesquisa utilizando as ferramentas da manutenção preventiva.


Assuntos
Análise de Falha de Equipamento , Manutenção de Equipamento , Extração de Catarata/instrumentação , Facoemulsificação/instrumentação , Manutenção Preventiva , Segurança de Equipamentos , Fatores de Tempo
20.
Indian J Ophthalmol ; 2002 Dec; 50(4): 333-7
Artigo em Inglês | IMSEAR | ID: sea-72147

RESUMO

The capsular tension ring (CTR) was originally introduced to reinforce the zonule in eyes with zonular dehiscence and to prevent capsular phimosis in eyes at risk for postoperative capsular shrinkage. Since then, other designs and applications have been developed and described. Modified CTRs with shields can be used in eyes with iris coloboma. A CTR with loops is intended for scleral fixation. Studies are underway to determine if the presence of the CTR helps avoid or limit capsular opacification. A number of different insertion techniques with the aid of manipulators, injectors and traction sutures have been described. We have developed a technique that is particularly effective in cases of zonular dehiscence due to its low solicitation to the damaged bag.


Assuntos
Humanos , Cápsula do Cristalino/cirurgia , Facoemulsificação/instrumentação , Polimetil Metacrilato , Próteses e Implantes , Desenho de Prótese , Implantação de Prótese/métodos