Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Medwave ; 20(1): e7772, 2020.
Artigo em Inglês, Espanhol | LILACS | ID: biblio-1087876

RESUMO

ANTECEDENTES La ubicación precisa de un cuerpo extraño intraocular es crucial para el manejo de pacientes con trauma ocular abierto. La tomografía computarizada se usa habitualmente para detectar su ubicación en el segmento posterior. Reportamos tres casos con diferentes cuerpos extraños intraoculares en el segmento posterior, que fueron localizados con precisión mediante la tomografía computarizada y ecografía modo B. PRESENTACIÖN DEL CASO Presentamos tres casos con diferentes mecanismos de trauma, tipos de cuerpo extraño intraocular, síntomas clínicos y pronóstico visual. La tomografía computarizada determinó la ubicación exacta de todos los cuerpos extraños intraoculares en el segmento posterior. El ultrasonido modo B se realizó en un paciente con un cuerpo extraño intraocular no metálico. El primer caso tuvo una lesión ocular perforante con un cuerpo extraño intraorbitario; el caso dos y el caso tres presentaron diferentes tipos de cuerpos extraños intraoculares con pronóstico diferente. El manejo y el pronóstico fue distinto en todos los casos; todos se manejaron con éxito. La ubicación exacta de los cuerpos extraños intraoculares utilizando las diferentes modalidades de diagnóstico es importante en estos pacientes. Estos casos sirven como recordatorio de que el uso adecuado de las pruebas de imagen es indispensable en el contexto de un cuerpo extraño intraocular relacionado con trauma ocular abierto. CONCLUSIÓN Las diferentes técnicas de imágenes son muy importantes para la detección de un cuerpo extraño intraocular. La tomografía computarizada es una de las modalidades de imagen más simple y efectiva para la localización de cuerpos extraños intraoculares relacionadas con trauma ocular abierto.


BACKGROUND: Determining the precise location of intraocular foreign bodies is crucial for the management of patients with open-globe injury. Computed tomography is the most common method for detecting intraocular foreign bodies in the posterior segment. In this article, we describe three cases of open-globe injury with different types of intraocular foreign bodies in the posterior segment that were accurately located using computed tomography scans and B-scan ultrasonography. CASE PRESENTATION: Each of the three cases of open-globe injury described in this report had different types of ocular trauma, clinical symptoms, and intraocular foreign bodies. Computed tomography scans showed the exact location of the intraocular foreign bodies in the posterior segment in two of the three cases. A B-scan ultrasound was used to determine the location of a non-metallic intraocular foreign body in the third case. All three patients had intraocular foreign bodies, and one of them had an additional orbital foreign body. Case 1 had a perforating eye injury with the additional intraorbital foreign body; Cases 2 and Case 3 had different types of intraocular foreign bodies and prognoses. Various treatment approaches were used, ranging from observation to surgery, depending on the location of the intraocular foreign bodies, and all cases were successfully managed. These three cases show that proper use of various types of imaging tests is indispensable in the context of an intraocular foreign body related to open-globe injury. CONCLUSION: Imaging techniques are crucial for the detection of an intraocular foreign body, and computed tomography is one of the simplest and most useful, especially in cases of open-globe injury.


Assuntos
Humanos , Masculino , Adolescente , Adulto , Tomografia Computadorizada por Raios X , Ferimentos Oculares Penetrantes/diagnóstico por imagem , Corpos Estranhos no Olho/diagnóstico por imagem , Ultrassonografia , Plásticos , Ferimentos por Arma de Fogo/complicações , Ferimentos por Arma de Fogo/diagnóstico por imagem , Traumatismos por Explosões/complicações , Traumatismos por Explosões/diagnóstico por imagem , Imageamento por Ressonância Magnética , Radiografia , Ferimentos Oculares Penetrantes/complicações , Corpos Estranhos no Olho/etiologia , Vidro , Metais
2.
Rev. bras. oftalmol ; 76(2): 88-90, Mar.-Apr. 2017. graf
Artigo em Inglês | LILACS | ID: biblio-899052

RESUMO

Abstract This report aims to show an unusual case of "transorbitário" wooden foreign body causing visual loss due to optic nerve damage on the side contralateral penetration of foreign matter.


Resumo O presente relato tem o objetivo de mostrar um caso incomum de corpo estranho de madeira "transorbitário" que causou perda visual por lesão do nervo óptico do lado contralateral a penetração do corpo estranho.


Assuntos
Humanos , Feminino , Adolescente , Corpos Estranhos no Olho/cirurgia , Corpos Estranhos no Olho/diagnóstico por imagem , Traumatismos do Nervo Óptico/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Ferimentos Oculares Penetrantes/cirurgia , Ferimentos Oculares Penetrantes/diagnóstico por imagem , Veículos Off-Road , Traumatismos do Nervo Óptico/cirurgia
3.
Indian J Ophthalmol ; 2011 Nov; 59(6): 505-507
Artigo em Inglês | IMSEAR | ID: sea-136238

RESUMO

Orbito-cranial foreign bodies present a treacherous situation that can escape detection. The only evidence of these foreign bodies may be the entry wound in the form of a small lid laceration. A two-year-old boy presented with right upper lid laceration following a fall two hours back. Analysis of the fluid around the wound revealed a beta-tracer protein (beta-TP) value of 33.5 mg/l suggestive of cerebrospinal fluid (CSF). Three-dimensional computed tomography (CT) scan revealed a foreign body measuring 4.2 cm × 0.8 cm passing from the orbital roof to the frontal lobe. The foreign body tract was explored through the eyelid laceration and a broken pencil was removed followed by dural patch graft. The patient developed no ocular or intracranial complications. Beta-TP, a highly specific marker of CSF is routinely used in screening patients of neurosurgery and otolaryngology with CSF leaks, however, its use has never been reported in ophthalmic literature based on an online PubMed search.


Assuntos
Lesões Encefálicas/metabolismo , Lesões Encefálicas/diagnóstico por imagem , Rinorreia de Líquido Cefalorraquidiano/metabolismo , Rinorreia de Líquido Cefalorraquidiano/diagnóstico por imagem , Pré-Escolar , Corpos Estranhos no Olho/metabolismo , Corpos Estranhos no Olho/diagnóstico por imagem , Ferimentos Oculares Penetrantes/metabolismo , Ferimentos Oculares Penetrantes/diagnóstico por imagem , Humanos , Oxirredutases Intramoleculares/metabolismo , Lipocalinas/metabolismo , Masculino , Órbita/lesões , Tomografia Computadorizada por Raios X
4.
EMJ-Emirates Medical Journal. 2008; 26 (1): 35-37
em Inglês | IMEMR | ID: emr-86406

RESUMO

We report a case of a 27 year old male who presented to us with a badly lacerated upper lid in left eye with proptosis, chemosis and decreased vision associated with traumatic cataract, iridodialysis, vitreous and retrobulbar haemorrhage following a work place injury with paper grinding machine. The diagnosis of an intraorbital foreign body initially evaded us, as clinical examination, plain x-ray and ultrasound of orbit failed to show it


Assuntos
Humanos , Masculino , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/diagnóstico por imagem , Ferimentos Oculares Penetrantes/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Local de Trabalho
5.
SJO-Saudi Journal of Ophthalmology. 2006; 20 (2): 142-145
em Inglês | IMEMR | ID: emr-80546

RESUMO

Anterior chamber foreign bodies often result from perforating ocular injuries and it should be considered as ocular emergency. We are reporting a 28-year-old man with post-traumatic metallic anterior chamber angle foreign body [FB]. Diagnosis was made by history, ocular examination, orbital x-ray and computed tomography [CT]. Localization was established by help of ultrasound biomicroscopy [UBM]. The foreign body was extracted through limbal incision opposite to FB entry site with good visual outcome


Assuntos
Humanos , Masculino , Ferimentos Oculares Penetrantes/diagnóstico por imagem , Iris/diagnóstico por imagem , Procedimentos Cirúrgicos Oftalmológicos , Diagnóstico por Computador , Tomografia Computadorizada por Raios X , Ultrassonografia
7.
Korean Journal of Ophthalmology ; : 114-118, 2002.
Artigo em Inglês | WPRIM | ID: wpr-197282

RESUMO

A 41-year-old man visited our clinic complaining of esodeviation of the right eye. He had been operated on for corneal laceration 3 years before. One month later, exodeviation of the right eye had developed. The result of computed tomography (CT) was reported as orbital abscess and cellulitis. Although antibiotic treatment was administered for 2 weeks, the exodeviation didn't improve. On ocular examinations performed in our hospital in November-2001, his right eye was esotropic and had a relative afferent pupillary defect. Vision of the right eye was decreased to 0.02. Fundus examination showed optic atrophy. A new CT scan disclosed a foreign body introduced into the right medial orbital wall, nasal cavity and ethmoidal sinus. Although foreign body was surgically removed, vision and eye movement were not improved. In the case of a patient who has undergone orbital trauma, complete history taking and physical examinations must be performed. On suspicion of a foreign body, imaging study such as CT or MRI must be performed. However, because CT findings can be variable, careful follow-up is needed.


Assuntos
Adulto , Humanos , Masculino , Corpos Estranhos no Olho/diagnóstico por imagem , Ferimentos Oculares Penetrantes/diagnóstico por imagem , Procedimentos Cirúrgicos Oftalmológicos , Órbita/lesões , Tomografia Computadorizada por Raios X , Madeira
8.
Indian J Ophthalmol ; 2001 Sep; 49(3): 197-8
Artigo em Inglês | IMSEAR | ID: sea-70565

RESUMO

A case of retained metallic arrowhead in orbit and sphenoidal sinus through an unusual route is reported. The eyeball was removed because of a possible risk of sympathetic ophthalmia.


Assuntos
Adulto , Corpos Estranhos no Olho/diagnóstico por imagem , Ferimentos Oculares Penetrantes/diagnóstico por imagem , Traumatismos Faciais/diagnóstico por imagem , Seguimentos , Humanos , Masculino , Metais , Traumatismo Múltiplo/diagnóstico por imagem , Procedimentos Cirúrgicos Oftalmológicos/métodos , Órbita/lesões , Seio Esfenoidal/lesões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA