1.
Rev. chil. radiol ; 21(3): 94-99, 2015. ilus, tab
Artigo em Espanhol | LILACS | ID: lil-771668

RESUMO

Because diagnostic and interventional radiology procedures represent one of the main sources of irradiation by ionizing radiation in the population, it has become a priority to become familiar with the quantities and units that account for patient dosimetry. There are countless documents and international recommendations on names, concepts, definitions and areas of application for various quantities and units used in patient dosimetry, in interventional and diagnostic radiology procedures. However, national legislation is not updated in this regard and does not provide, in any of its documents, an updated glossary that enables finding this type of information quickly and precisely. Therefore, this review paper presents in a didactic way and in plain language, the main quantities and units to be used in the dosimetry of patients undergoing diagnostic and interventional radiology procedures.


Debido a que los procedimientos de radiodiagnóstico e intervencionismo representan una de las principales fuentes de irradiación a la población por radiaciones ionizantes, se vuelve prioritario conocer las magnitudes y unidades que dan cuenta de la dosimetría a los pacientes. Existen innumerables documentos y recomendaciones internacionales sobre nombres, conceptos, definiciones y campos de aplicación para diversas magnitudes y unidades utilizadas en la dosimetría de pacientes en procedimientos de radiodiagnóstico e intervencionismo. Sin embargo, la legislación nacional no se encuentra actualizada en este sentido y no contempla en ninguno de sus documentos, un glosario actualizado que permita encontrar en forma rápida y precisa este tipo de información. Por lo anterior, este trabajo de revisión presenta de manera didáctica y en un lenguaje sencillo, las principales magnitudes y unidades que se deben utilizar en la dosimetría de pacientes sometidos a procedimientos de radiodiagnóstico e intervencionismo.


Assuntos
Humanos , Diagnóstico por Imagem/normas , Kerma , Radiografia Intervencionista/normas , Radiometria/normas
2.
Radiol. bras ; 46(2): 96-100, mar.-abr. 2013. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-673352

RESUMO

OBJETIVO: Verificar a viabilidade de filmes radiocrômicos como um dosímetro alternativo para estimativa da dose média em cortes múltiplos a partir dos perfis de kerma.MATERIAIS E MÉTODOS: Os filmes foram distribuídos em cilindros posicionados no centro e nas regiões periféricas de um objeto simulador padrão de abdome utilizado para dosimetria em tomografia computadorizada.RESULTADOS: Os valores de dose média em cortes múltiplos calculados foram 13,6 ± 0,7, 13,5 ± 0,7 e 18,7 ± 1,0 mGy para os valores de passo (pitch) de 0,75, 1,00 e 1,50, respectivamente.CONCLUSÃO: Apesar de os resultados mostrarem valores menores que o nível de referência de radiodiagnóstico de 25 mGy estabelecido pela legislação brasileira para exames de abdome, eles sugerem que há espaço para otimização dos procedimentos e uma revisão do valor para o nível de referência de radiodiagnóstico brasileiro.


OBJECTIVE: To evaluate the feasibility of using radiochromic films as an alternative dosimeter to estimate the multiple scan average dose on the basis on kerma profiles.MATERIALS AND METHODS: The radiochromic films were distributed in cylinders positioned in the center and in four peripheral bores of a standard abdominal phantom utilized for computed tomography dosimetry.RESULTS: Values for multiple scan average dose values corresponded to 13.6 ± 0.7, 13.5 ± 0.7 and 18.7 ± 1.0 mGy for pitch of 0.75, 1.00 and 1.50, respectively.CONCLUSION: In spite of results showing lower values than the reference level for radiodiagnosis (25 mGy) established by the Brazilian regulations for abdominal studies, it is suggested that there is room to optimize procedures and review the reference level for radiodiagnosis in Brazil.


Assuntos
Humanos , Masculino , Feminino , Dosimetria/métodos , Kerma , Órgãos Governamentais , Guias como Assunto , Tomografia Computadorizada por Raios X/normas
3.
Radiol. bras ; 45(4): 210-214, jul.-ago. 2012. graf, tab
Artigo em Português | LILACS | ID: lil-647861

RESUMO

OBJETIVO: Avaliar as exposições pediátricas de radiologia intervencionista em dois hospitais do Estado da Bahia, visando contribuir para a construção de um cenário estadual e nacional, possibilitando o conhecimento das exposições e da necessidade de sua otimização, visto que as peculiaridades que envolvem a radiologia e a pediatria se potencializam quando se trata de procedimentos de radiologia intervencionista, em razão das doses elevadas de radiação. MATERIAIS E MÉTODOS: Foram avaliados 32 procedimentos em quatro salas nos dois principais hospitais que realizam procedimentos de radiologia intervencionista pediátrica na Bahia. Foram avaliados os valores de kerma no ar incidente e o produto kerma-área no ar de 27 procedimentos cardiológicos e 5 procedimentos cerebrais. RESULTADOS: Os valores máximos de produto kerma-área e kerma obtidos para procedimentos cardiológicos foram, respectivamente, 129,9 Gy.cm² e 947,0 mGy, e para procedimentos cerebrais, 83,3 Gy.cm² e 961,0 mGy. CONCLUSÃO: Os resultados deste estudo mostraram valores de exposições superiores em até 14 vezes os obtidos em estudos realizados em outros países, chegando próximos de resultados obtidos para procedimentos em adultos. Isto revela quão elevadas podem ser as exposições pediátricas, indicando a necessidade de constante otimização dos procedimentos e avaliação das exposições.


OBJECTIVE: To evaluate pediatric radiation exposure in procedures of interventional radiology in two hospitals in the Bahia state, aiming at contributing to delineate the scenario at the state and national levels. The knowledge of exposure levels will allow an evaluation of the necessity of doses optimization, considering that peculiarities of radiology and pediatrics become even more significant in interventional radiology procedures which involve exposure to higher radiation doses. MATERIALS AND METHODS: A total of 32 procedures were evaluated in four rooms of the two main hospitals performing pediatric interventional radiology procedures in the Bahia state. Air kerma rate and kerma-area product were evaluated in 27 interventional cardiac and 5 interventional brain procedures. RESULTS: Maximum values for air kerma rate and kerma-area product and air kerma obtained in cardiac procedures were, respectively, 129.9 Gy.cm² and 947.0 mGy; and, for brain procedures were 83.3 Gy.cm² and 961.0 mGy. CONCLUSION: The present study results showed exposure values up to 14 times higher than those found in other foreign studies, and approximating those found for procedures in adults. Such results demonstrate excessive exposure to radiation, indicating the need for constant procedures optimization and evaluation of exposure rates.


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Lactente , Pré-Escolar , Criança , Adolescente , Cérebro , Coração , Imagem por Ressonância Magnética Intervencionista , Kerma , Radiologia Intervencionista , Interpretação Estatística de Dados
4.
Radiol. bras ; 45(2): 71-81, mar.-abr. 2012. ilus, tab
Artigo em Português | LILACS | ID: lil-624455

RESUMO

OBJETIVO: Apresentar uma ferramenta de análise de dados que pode ser utilizada para proteção de pacientes e trabalhadores em áreas de uso de equipamentos móveis. MATERIAIS E MÉTODOS: Foi desenvolvida uma ferramenta, em planilha ativa Excel®, que utiliza medidas de exposição para gerar um banco de dados de fatores de forma e calcular o kerma no ar ao entorno de um leito. O banco de dados inicial foi coletado com três equipamentos móveis. Um espalhador não antropomórfico foi utilizado, sendo realizadas medidas de exposição em uma malha de (4,2 × 4,2) m², ao passo de 0,3 m. RESULTADOS: A ferramenta calcula o kerma no ar (associado à exposição de pacientes expostos e ao equivalente de dose ambiente) à radiação secundária. Para distâncias inferiores a 60,0 cm, valores acima do limite máximo de equivalente de dose ambiente definido para área livre (0,5 mSv/ano) foram verificados. Os dados coletados a 2,1 m foram sempre inferiores a 12% do referido limite. CONCLUSÃO: A ferramenta é capaz de auxiliar na proteção radiológica de pacientes e trabalhadores, quando associada à coleta de dados adequada, pois possibilita a determinação de áreas livres ao entorno de leitos em áreas onde equipamentos móveis geradores de radiação X são utilizados.


OBJECTIVE: To present a data analysis toolkit that may be utilized with the purpose of radiation protection of hospital inpatients and workers in areas where mobile apparatuses are used. MATERIALS AND METHODS: An Excel® ActiveSheet was utilized to develop a computational toolkit with exposure measurements to generate a database of shape factors and to calculate the air kerma around hospital beds. The initial database included data collected with three mobile apparatuses. A non-anthropomorphic phantom was utilized and exposure measurements were performed on a (4.2 × 4.2) m² mesh-grid at 0.3 m steps. RESULTS: The toolkit calculates the air kerma (associated with patients' radiation exposure and with ambient equivalent dose) under secondary radiation. For distances lower than 60.0 cm, values above the maximum ambient equivalent dose threshold defined for radiation free areas (0.5 mSv/year) were verified. Data collected at 2.1 m have always presented values lower than 12% of that threshold. CONCLUSION: The toolkit can aid in the radiological protection of patients and workers, provided it is combined with appropriate data collection, since it allows the determination of radiation free areas around beds in rooms where mobile X-ray apparatuses are utilized.


Assuntos
Humanos , Kerma , Exposição à Radiação , Proteção Radiológica , Radiologia , Radiometria/normas , Software , Bases de Dados como Assunto , Manual de Segurança Radiológica , Saúde Ocupacional , Segurança do Paciente
5.
Radiol. bras ; 43(1): 39-45, jan.-fev. 2010. tab, ilus
Artigo em Português | LILACS | ID: lil-542688

RESUMO

OBJETIVO: O processo de migração de sistemas analógicos para digitalizados, para aplicações diagnósticas, requer cuidados específicos, a fim de manter a qualidade das imagens e minimizar a dose no paciente. Este trabalho tem como objetivo analisar e comparar a qualidade da imagem e o kerma num simulador não antropomórfico de tórax gerados por sistemas analógicos e digitalizados CR. MATERIAIS E MÉTODOS: Foram analisados a qualidade da imagem e o kerma, de entrada e saída, no simulador para dois equipamentos de raios X diferentes (Siemens e Emic), com diferentes sistemas de retificação de onda (12 pulsos e alta frequência). Ambos os sistemas (analógico e digitalizado) estavam sendo utilizados no mesmo local. Foram geradas imagens em filme e em image plates. RESULTADOS: Foi observado aumento na tensão e/ou na carga transportada pelo tubo de raios X quando houve a migração para o sistema CR, para manutenção das características diagnósticas da imagem. Isto resultou em aumento de kerma coletado. CONCLUSÃO: As maiores diferenças determinadas (aumento de dose e redução da qualidade da imagem) foram observadas no equipamento com retificação de onda de 12 pulsos e transdutor de imagem CR (image plates).


OBJECTIVE: The process of migration from analog to digital imaging system requires specific attention to preserve images quality and minimizing the dose to the patients. The present study was aimed at analyzing and comparing images quality and entrance and exist air kerma measurements in a non-anthropomorphic chest phantom with analog and CR digital imaging systems. MATERIALS AND METHODS: Two different X-ray units (Siemens and Emic) with different wave rectification systems (12-pulse and high-frequency) were utilized in a single institution along the process of migration from analog to CR digital imaging system. Images were acquired on films and image plates. RESULTS: An increase on the X-ray tube peak voltage and/or load was observed in the migration from analog to CR digital system to preserve the diagnostic quality of the image. As a result, an increase in the air kerma rate was observed. CONCLUSION: The greatest differences (increase in dose and decrease in image quality) were observed with the 12-pulse wave rectification system with the CR image transducer (imaging plates).


Assuntos
Conversão Análogo-Digital , Intensificação de Imagem Radiográfica/tendências , Kerma , Tecnologia Radiológica , Processamento de Imagem Assistida por Computador , Controle de Qualidade , Relação Dose-Resposta à Radiação
6.
Radiol. bras ; 42(6): 375-378, nov.-dez. 2009. ilus, tab
Artigo em Inglês, Português | LILACS | ID: lil-536419

RESUMO

OBJETIVO: O objetivo deste trabalho é o de estudar a otimização da qualidade da imagem fluoroscópica e a taxa de kerma no ar de entrada na superfície do paciente em procedimentos de radiologia intervencionista, utilizando-se de um objeto simulador adaptado para fluoroscopia. MATERIAIS E MÉTODOS: Foi utilizado um objeto simulador desenvolvido para avaliação de imagens em radiologia convencional. O objeto simulador foi adaptado para fluoroscopia mediante incorporação de dois cateteres com diferentes espessuras, ambos utilizados em radiologia intervencionista. Os níveis de taxa de kerma no ar de entrada na superfície do paciente foram determinados utilizando-se este objeto simulador. RESULTADOS: A avaliação dos parâmetros técnicos para diversos modos de exposição de um equipamento fluoroscópico com digitalização de imagens permitiu estabelecer os indicadores de taxa de kerma no ar, que permitem a otimização da qualidade das imagens em procedimentos intervencionistas. A redução na taxa de kerma no ar de entrada na superfície do paciente pode chegar a 67 por cento. CONCLUSÃO: A otimização da qualidade da imagem utilizando-se um objeto simulador possibilita reduzir a taxa de kerma no ar de entrada na superfície do paciente, sem perda considerável de informação diagnóstica.


OBJECTIVE: The objective of the present study is to analyze the optimization of fluoroscopic image quality and patient entrance surface air kerma rate in interventional radiology procedures, utilizing a phantom adapted for fluoroscopy. MATERIALS AND METHODS: The authors utilized a phantom developed for evaluating conventional radiological images adapted for fluoroscopy through the addition of two catheters with different diameters, both of them utilized in interventional radiology. The patient entrance surface air kerma rate was determined with the aid of this phantom. RESULTS: The evaluation of technical parameters for different exposure modes of a digital fluoroscopic imaging system has allowed the determination of the air kerma rate, enabling the optimization of the image quality in interventional procedures. The decrease in the patient entrance surface air kerma rate may achieve 67 percent. CONCLUSION: The optimization of fluoroscopic image quality achieved with a phantom allows reducing the patient entrance surface air kerma with no significant loss of diagnostic performance.


Assuntos
Doses de Radiação , Fluoroscopia/métodos , Kerma , Radiologia Intervencionista , Dosagem , Otimização de Processos
7.
Radiol. bras ; 42(5): 315-319, set.-out. 2009. graf, tab
Artigo em Português | LILACS | ID: lil-530180

RESUMO

OBJETIVO: Avaliar os fatores de técnica utilizados durante exames de tórax póstero-anterior em pacientes-padrão e correlacioná-los aos valores de kerma no ar na superfície de entrada e à qualidade das imagens clínicas. MATERIAIS E MÉTODOS: O estudo foi realizado em três hospitais do Rio de Janeiro, num total de cinco salas de raios X, com dez pacientes por sala. As imagens foram avaliadas pelos radiologistas dos serviços segundo o protocolo europeu. O kerma no ar na superfície de entrada foi estimado a partir da curva de rendimento do equipamento de raios X, que foi obtida utilizando câmara de ionização acoplada a um eletrômetro. Análise de variância foi realizada para verificar se a diferença entre os valores de kerma no ar na superfície de entrada é significativa. RESULTADOS: Os valores de kerma no ar na superfície de entrada variaram entre 0,05 e 0,26 mGy, com média 60 por cento inferior ao nível de referência publicado na Portaria 453. Das imagens avaliadas, 98 por cento atenderam acima de 65 por cento dos critérios de qualidade. CONCLUSÃO: Para um padrão de qualidade da imagem, aceitável para o diagnóstico, verificou-se ampla variação do kerma no ar na superfície de entrada para pacientes-padrão. Isto demonstra a falta de padronização dos fatores de técnica e a existência de um potencial de redução do valor do kerma no ar na superfície de entrada.


OBJECTIVE: To evaluate technical factors involved in posteroanterior chest radiography in standard patients, and correlating them with entrance surface air kerma rate and with the clinical images quality. MATERIALS AND METHODS: The present study was developed at three hospitals in Rio de Janeiro, Brazil, involving a total of five x-ray rooms, with ten patients per room. The images were evaluated by the radiologists of the institutions, in accordance with the European protocol. The estimation of surface entrance air kerma rate was based on the x-ray equipment output curve obtained with an ionization chamber coupled with an electrometer. Variance analysis was performed to evaluate the significance of the difference between entrance surface air kerma rates. RESULTS: Entrance surface air kerma rates ranged between 0.05 and 0.26 mGy, with a mean value 60 percent lower than the reference level established by the Order (Portaria) 453. Among the images evaluated, 98 percent fulfilled > 65 percent of the images quality criteria. CONCLUSION: For a standard image quality that is acceptable for diagnosis purposes, a significant variation was observed in the entrance surface air kerma rate for standard patients, demonstrating the lack of technical factors standardization and a potential for decreasing the entrance surface air kerma rate.


Assuntos
Kerma , Radiografia Torácica/efeitos da radiação , Melhoria de Qualidade , Radiação Ionizante
8.
Radiol. bras ; 41(5): 325-329, set.-out. 2008. graf, tab
Artigo em Inglês, Português | LILACS | ID: lil-496937

RESUMO

OBJETIVO: Os objetivos deste trabalho são: a) avaliar os procedimentos radiográficos e estimar o valor do kerma no ar na superfície de entrada nos recém-nascidos prematuros submetidos a exames de tórax e abdome, realizados no setor de neonatologia de um hospital público de Belo Horizonte; b) estimar as doses nos órgãos e os respectivos riscos de ocorrência de câncer nesses órgãos em decorrência das exposições à radiação. MATERIAIS E MÉTODOS: Foram analisados os prontuários dos pacientes internados no setor de neonatologia desse hospital durante o período de maio a setembro de 2004, anotando-se os dados antropométricos, data de internação/alta, exames de raios X realizados. O kerma no ar na superfície de entrada foi determinado a partir do rendimento do tubo de raios X e dos parâmetros de irradiação utilizados nos exames. As doses nos órgãos foram estimadas com o software PCXMC e o risco, durante o restante da expectativa de vida, com o software IREP. RESULTADOS: O valor médio do kerma no ar na superfície de entrada por exame foi abaixo do nível de referência da publicação da Comunidade Européia. Para o paciente mais severamente irradiado, os órgãos mais suscetíveis à ocorrência de câncer foram fígado, mama e estômago, com valores máximos de excess relative risk, respectivamente, de 3,4 por cento, 2,3 por cento e 1,7 por cento. CONCLUSÃO: Foi constatada a necessidade de otimização dos procedimentos radiográficos com vista à diminuição do risco para os recém-nascidos, que apesar de ser considerado baixo (comparativamente ao benefício), deve ser sempre diminuído para valores tão baixos quanto razoavelmente exeqüíveis.


OBJECTIVE: The present study was aimed at: a) evaluating radiographic procedures and estimating entrance surface air kerma in preterm neonates submitted to chest and abdominal radiography at the unit of neonatology in a public hospital of Belo Horizonte, MG, Brazil; b) estimating the dose to organs and respective risks for cancer as a result from radiation exposure. MATERIALS AND METHODS: Records of patients admitted to the unit of neonatology of this hospital in the period between May and September 2004 were reviewed. Anthropometric data, admission/discharge dates and radiographic studies performed were recorded for each of the patients. The calculation of the entrance surface air kerma was based on the x-ray tube output and irradiation parameters adopted for examinations. Dose to organs was calculated with the aid of the software PCXMC, and the lifetime risk for cancer, with the software IREP. RESULTS: Mean entrance surface air kerma per examination was below the diagnostic reference levels recommended by the European Community. In the most severely irradiated patients, liver, breast and stomach were the organs at highest risk for cancer, with maximum excess relative risk of respectively 3.4 percent, 2.3 percent, and 1.7 percent. CONCLUSION: The present study demonstrated the need for optimization of radiographic procedures in order to reduce the risks for neonates that, in spite of being considered to be low as compared with the benefits, should be reduced to values as low as reasonably achievable.


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Dosimetria/efeitos adversos , Kerma , Neoplasias Induzidas por Radiação , Proteção Radiológica , Riscos de Radiação , Carcinógenos , Radiação Ionizante , Radiometria , Medição de Risco
9.
Radiol. bras ; 41(1): 39-43, jan.-fev. 2008. ilus, tab
Artigo em Inglês, Português | LILACS | ID: lil-477722

RESUMO

OBJETIVO: Desenvolver uma câmara de ionização de placas paralelas de dupla face para determinação de kerma no ar e taxa de kerma no ar em campos de radiação-X utilizados em radiografia convencional e mamografia. MATERIAIS E MÉTODOS: A câmara desenvolvida tem janelas de entrada de poliéster aluminizado, elétrodos internos e anéis de guarda de alumínio em uma face (face A) e de grafite na outra (face G). Neste trabalho foram testadas as características operacionais de linearidade, dependência angular e energética de resposta. RESULTADOS: A linearidade de resposta foi de 0,86 por cento para a face A e de 0,92 por cento para a face G. Para ângulos de incidência da radiação de 0º a ± 5º, a variação da resposta relativa foi menor que 0,8 por cento para ambas as faces da câmara. A dependência energética de resposta foi de 0,8 por cento para a face A nas qualidades de raios-X para diagnóstico convencional e de 2,4 por cento para a face G da câmara nas qualidades de raios-X para mamografia. CONCLUSÃO: Esta câmara pode ser utilizada rotineiramente na determinação de kerma no ar e taxa de kerma no ar em feixes de raios-X utilizados em radiografia convencional e mamografia.


OBJECTIVE: To develop a double-faced plane-parallel ionization chamber for measurement of air kerma and air kerma rate in X-radiation fields utilized in conventional radiography and mammography. MATERIALS AND METHODS: The chamber has entrance windows made of aluminized polyester film, inner and guard electrodes of aluminum at one side (face A) and graphite at the other side (face G). The present study evaluated operational characteristics as regards response linearity, angular and energy dependence. RESULTS: The linearity of response was 0.86 percent for face A and 0.92 percent for face G. For radiation incidence angles, of 0º to ± 5º, the response variation was less than 0.8 percent for both faces of the chamber. The energy dependence of response was 0.8 percent for face A on X-ray qualities for conventional radiography, and 2.4 percent for the face G of the chamber on X-ray qualities for mammography. CONCLUSION: This chamber can be utilized on a routine basis for measurement of air kerma and air kerma rate in X-ray beams utilized in conventional radiography and mammography.


Assuntos
Kerma , Mamografia/instrumentação , Radiometria/instrumentação , Desenvolvimento Tecnológico , Controle de Qualidade , Radiação Ionizante , Tecnologia Radiológica
10.
Radiol. bras ; 40(6): 409-413, nov.-dez. 2007. graf, tab
Artigo em Inglês, Português | LILACS | ID: lil-472001

RESUMO

OBJETIVO: Avaliar a freqüência das incidências radiográficas realizadas nos seios da face de pacientes pediátricos em hospitais de Belo Horizonte, MG, as condições de radioproteção, as técnicas radiográficas empregadas, o kerma no ar de entrada e as doses nos órgãos mais expostos. MATERIAIS E MÉTODOS: Foram coletados os dados dos pacientes e parâmetros de técnica radiográfica empregados em exames de crianças de 1 a 16 anos de idade, em cinco salas de quatro hospitais da cidade, observando, também, aspectos de proteção radiológica. O kerma no ar de entrada foi estimado a partir dos rendimentos dos tubos de raios-x e as doses nos órgãos utilizando o software PCXMC. RESULTADOS: Os valores médios do kerma no ar de entrada para as cinco salas foram, respectivamente, 1.398 µGy, 829 µGy, 877 µGy, 1.168 µGy e 3.886 µGy para pacientes entre 1 e 5 anos de idade. CONCLUSÃO: Foi constatado que as incidências mento-naso e fronto-naso são comumente solicitadas em conjunto, na maioria dos hospitais, o que confere dose significativa para os pacientes. Os riscos para os pacientes podem ser diminuídos mediante a utilização de cilindros de colimação, a não-utilização de grades antiespalhamento, o emprego de altos valores de tensão e baixos valores de tempo.


OBJECTIVE: The present study was aimed at evaluating the frequency of radiographic assessment of paranasal sinuses in pediatric patients in hospitals of Belo Horizonte, MG, Brazil. Additionally, aspects regarding radiation protection conditions and radiographic parameters were evaluated, and entrance air kerma and organ doses were estimated. MATERIALS AND METHODS: Patients' data and parameters of radiographic technique employed in the assessment of children in the age range between 1 and 16 years were collected in five examination rooms of four hospitals in Belo Horizonte, also taking into consideration the radiation protection aspects. Entrance air kerma calculation was based on the x-ray tubes output, and organ doses were estimated with the PCXMC software. RESULTS: Mean entrance air kerma values found in the five rooms were, respectively, 1398 µGy, 829 µGy, 877 µGy, 1168 µGy and 3886 µGy for patients with ages between 1 and 5 years. CONCLUSION: Most frequently, mento-naso and fronto-naso views are requested in conjunction in the majority of hospitals, which increases the radiation dose to the patients. It may be concluded that the risks for patients can be reduced by means of the utilization of an appropriate x-ray field, non-utilization of antiscattering grids, selection of high voltages and lower exposure times.


Assuntos
Humanos , Masculino , Feminino , Lactente , Pré-Escolar , Criança , Adolescente , Exposição à Radiação , Radiação Ionizante , Relação Dose-Resposta à Radiação , Sinusite , Doses de Radiação , Kerma
11.
Rev. chil. tecnol. méd ; 27(2): 1376-1386, dic. 2007. ilus, graf
Artigo em Espanhol | LILACS | ID: lil-482838

RESUMO

Los objetivos generales fueron determinar las curvas de isodosis dentro del Laboratorio de Hemodinamia, mediante la evaluación del KERMA (Kinetic Energy Release in Matter) en aire y relacionar las zonas analizadas con la distribución que adopta el personal ocupacionalmente expuesto (POE) durante la realización de estos procedimientos. Los objetivos específicos fueron medir la tasa de exposición con cámara de ionización para las distintas proyecciones utilizadas, calcular la tasa de dosis equivalente en mSv/h a la cual está expuesto el POE dentro del laboratorio en los distintos puntos utilizados para efectuar las mediciones e identificar los puntos con los mayores niveles de KERMA en aire dentro del laboratorio. Las mediciones fueron realizadas según proyección y espesor de fantoma con una misma cámara de ionización Radcal de 1800 cc ubicada en puntos definidos de antemano dentro del laboratorio de hemodinámica. Se confeccionaron gráficos y mapas con curvas de distribución de dosis superpuestas al plano arquitectónico del laboratorio de hemodinámica, delimitando en los mapas los niveles de distribución de dosis asociados a determinados sectores. Se identificó un punto de ubicación del POE en el cual la tasa de exposición y su equivalente tasa de dosis presentó los niveles más altos y peligrosos para las proyecciones y espesores de fantoma utilizados en este trabajo y que simularon condiciones laborales cotidianas. Se concluye que las curvas de isodosis obtenidas se modifican según la incidencia del haz de Rayos X o según las proyecciones utilizadas durante los procedimientos angiográficos, esto se desprende de la simple observación de los gráficos y mapas con las curvas de distribución de dosis.


The general objectives were to determine isodose's curves whithin Hemodinamia's Laboratory, by means of the evaluation of the KERMA (Kinetic Energy Release in Matter) in air and to relate the zones examined with the distribution that the staff occupationally exposed (POE) during the realization of these procedures embraces. The specific objetives were to measure the rate of exposition with ionization chamber for the different utilized projections, estimating the rate of exposition with ionization chamber for the different utilized projections, estimating the rate of equivalent dose around mSv/h witch the POE within the Laboratory in the several utilized points to make measurements and to identify the points with KERMA's bigger levels in air within the laboratory is on view to. Measurements were accomplished according to projection and fantoma's thickness with a same ionization chamber Radcal of 1800 cc located in points circumscribed in advance within Hemodinamia's Laboratory. They manufactured graphics and maps with curves of distribution of dose.


Assuntos
Humanos , Relação Dose-Resposta à Radiação , Pessoal de Laboratório , Exposição Ocupacional , Kerma , Laboratórios , Exposição à Radiação , Radiometria/instrumentação , Espalhamento de Radiação
12.
Braz. dent. j ; 15(3): 214-219, Sept.-Dec. 2004. tab, graf
Artigo em Inglês | LILACS | ID: lil-431296

RESUMO

Este estudo avaliou a redução da taxa de kerma no ar, o espectro de energia dos raios X e alterações na qualidade da imagem radiográfica. Comparações com várias espessuras do filtro de liga de alumínio-cobre em três diferentes porcentagens foram feitas com o filtro de alumínio. Os experimentos foram feitos utilizando-se um aparelho de raios X odontológico convencional, obtendo radiografias com auxílio de um fantoma de segmento de mandíbula e de uma escala de densidade confeccionada com alumínio laminado. Dependendo da espessura da filtração da liga de alumínio-cobre, o feixe de raios X pôde ser endurecido em relação ao filtro de alumínio. O uso do filtro de liga de alumínio-cobre resultou em 8,40% a 47,33% de redução da taxa média de kerma no ar e indicou contraste da imagem radiográfica sem alteração, quando comparado com a filtração de alumínio, mostrando que os filtros de liga de alumínio-cobre tornam-se alternativas aceitáveis em relação aos filtros de alumínio.


Assuntos
Filtração/instrumentação , Intensificação de Imagem Radiográfica , Radiografia Dentária , Critérios de Qualidade do Ar , Ligas , Kerma
13.
Pesqui. odontol. bras ; 16(1): 77-82, jan.-mar. 2002. graf
Artigo em Português | LILACS, BBO | ID: lil-308372

RESUMO

O objetivo neste trabalho foi avaliar os efeitos da filtraçäo alternativa da liga alumínio-zinco em aparelhos de raios X odontológicos, em relaçäo ao espectro de energia dos feixes de raios X, a taxa de kerma no ar, o índice de contraste nas radiografias obtidas e a qualidade das imagens radiográficas. Este estudo foi realizado comparando-se o filtro convencional de alumínio com várias espessuras do filtro de liga alumínio-zinco, em diferentes porcentagens do elemento zinco na liga (2 por cento, 3 por cento, 4 por cento e 5 por cento). Foi utilizado um de raios X odontológicos convencional, operando com 60 kVp e 70 kVp, e filmes radiográficos dos grupos D e E de sensibilidade. Foram realizadas radiografias de um "phantom" e de uma escala de densidade de alumínio. Os resultados mostraram que uso dos filtros de liga Al-Zn resultou em um näo-endurecimento dos feixes. A taxa de kerma no ar diminuiu em até 18,53 porcento, sem alteraçäo no contraste das radiografias e a qualidade das imagens teve uma boa aceitaçäo pelos examinadores. A análise dos resultados nos levou a concluir que o filtro de liga Al-Zn 2 por cento, com 1,99 mm de espessura, tensäo de 60 kVp, quando usado com filme D, foi o que obteve melhor desempenho, reduzindo a taxa de kerma no ar sem variar o índice de contraste das radiografias, mantendo a qualidade da imagem aceitável para diagnóstico, sem contudo aumentar o tempo de exposiçäo


Assuntos
Ligas Dentárias , Filtros , Espectrometria por Raios X , Kerma