Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 227
Filtrar
1.
Rev. Flum. Odontol. (Online) ; 1(63): 168-179, jan-abr. 2024. ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-1567021

RESUMO

The flexural resistence is one of the most used test in researchs of mechanical characterization of resin composites for dental restoration. ISO 4049 photopolymerization technique performed static application stages of light tip. To polymerize the entire area of the specimen some areas must receive extra radiation. These areas with extra radiation are called overlap areas. In an attempt to remedy this problem, this research compared the ISO method with a new method using constant movement (CM) during photopolymerization. Twenty specimens (SPs) were produced with 25 x 2 x 2 mm, for each group, 10 specimens being polymerized by the static technique recommended by the ISO-4049 and 10 specimens polymerized by the CM technique for each LED curing light used. After Tukey's statistical analysis, it was found that there was no statistical difference in relation to flexural strength (FS) and for the flexural modulus of elasticity (EF). However, the standard deviation of both FS and EF were much lower in MC than in ISO. Therefore, the photopolymerization by CM of the samples for the flexural strength test proved to be a possible solution to the problem of overlap of the technique proposed by ISO.


O teste de flexão é um dos mais utilizados em pesquisa de caracterização mecânica de compósitos resinosos para restauração dentária. A técnica ISO 4049 é feita em etapas com aplicação estática da luz. Para que toda a área do corpo de prova receba esta radiação é preciso que outras áreas recebam radiação extra. Na tentativa de sanar tal problema, esta pesquisa comparou o método da ISO com um método que utiliza um movimento constante (MC) durante a fotopolimerização. Foram produzidos 20 corpos de provas (CPs) com 25 x 2 x 2 mm, para cada grupo, sendo 10 polimerizados pela técnica estática recomendada pela normativa ISO-4049 e 10 polimerizados pela técnica de movimentação contínua (MC) para cada fotopolimerizador LED utilizado. Após análise estatística de Tukey apurou-se que não houve diferença estatística em relação à resistência à flexão (RF) e para o módulo de elasticidade em flexão. Porém, percebe-se, que o desvio padrão tanto da RF quanto do EF foram bem menores em MC do que em ISO. Sendo assim, a fotopolimerização em movimentação constante (MC) das amostras para o teste de resistência à flexão se mostrou como uma possível solução para o problema de sobreposição na técnica proposta pela ISO.


Assuntos
Resinas Compostas , Lâmpadas de Polimerização Dentária , Módulo de Elasticidade , Resistência à Flexão
2.
Braz. dent. sci ; 27(2): 1-7, 2024. ilus, tab
Artigo em Inglês | LILACS, BBO | ID: biblio-1570673

RESUMO

Objective: Mouthguards can reduce or even prevent orofacial injuries. These devices are responsible for absorbing part of the energy of an impact force, while the remaining part is dissipated. The present study aimed to evaluate how the plasticization temperature of the sports mouthguards' manufacturing process influences their mechanical properties and protective potential. Material and Methods: Specimens were made according to different plasticization temperatures (85°C, 103°C, 121°C and 128°C) and different dental brands of EVA sheets (Bio-art and FGM). Plasticization temperatures were measured using a culinary thermometer (Term; TP300). The mechanical properties evaluated were: energy absorption capacity, deformation, and modulus of elasticity. Compression testing was carried out in the Emic universal testing machine with a speed of 600 mm/min to simulate a punch. Results: EVA sheets submitted to the highest temperatures (121°C and 128°C) had their energy absorption capacity reduced. In addition, the samples that plasticized at the lowest temperature (85°C) showed higher absorption capacity, lower elastic modulus, and less variation in its dimensions. It proved to be the most effective in protection and with greater durability. Conclusion: The plasticization temperature proved to be an influential factor in the absorption capacity of mouthguards, so the increase in temperature led to a reduction in this property, especially when higher than 120°C. In addition, the plasticization temperature may vary depending on the sheet brand used. Finally, the kitchen thermometer used proved to be efficient and practical, thanks to its easy-to-read display and wide availability on the market. (AU)


Objetivo: Os protetores bucais são capazes de reduzir ou mesmo prevenir lesões orofaciais. Esses dispositivos são responsáveis por absorver parte da energia de uma força de impacto, enquanto a parte restante é dissipada. Este estudo teve como objetivo avaliar como a temperatura de plastificação de protetores bucais esportivos influencia em suas propriedades mecânicas e no seu potencial protetivo. Material e Métodos: Foram confeccionados modelos de trabalho segundo diferentes temperaturas de plastificação (85°C, 103°C, 121°C e 128°C) e distintas marcas odontológicas de placas de EVA (Bio-art e FGM). As temperaturas de plastificação foram medidas com termômetro culinário da marca Term/TP300. As propriedades mecânicas avaliadas foram capacidade de absorção de energia, deformação e módulo de elasticidade. O teste de compressão foi realizado na máquina de ensaios universal Emic com velocidade de 600 mm/min, a fim de simular um soco. Resultados: As placas de EVA submetidas às mais altas temperaturas (121°C e 128°C) tiveram sua capacidade de absorção de energia reduzida. Além disso, as amostras que plastificaram na temperatura mais baixa (85°C) apresentaram maior capacidade de absorção, menor módulo de elasticidade e menor variação em suas dimensões. Assim, mostraram-se a mais eficaz na proteção e com maior durabilidade. Conclusão: A temperatura de plastificação demonstrou ser um fator influente na capacidade de absorção dos protetores bucais, de modo que o aumento da temperatura levou a uma redução desta propriedade, principalmente quando superior a 120°C. Além disso, a temperatura de plastificação pode variar dependendo da marca comercial utilizada. Por fim, o termômetro culinário utilizado mostrou-se eficiente e prático, pela facilidade de leitura e por ser facilmente encontrado no mercado (AU)


Assuntos
Temperatura , Polietileno , Módulo de Elasticidade , Absorção Fisico-Química , Protetores Bucais
3.
Int. j. morphol ; 41(5): 1288-1296, oct. 2023. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1521049

RESUMO

El propósito de este estudio fue analizar el comportamiento mecánico de la estructura dental sana de un primer premolar inferior humano sometido a fuerzas funcionales y disfuncionales en diferentes direcciones. Se buscó comprender, bajo las variables contempladas, las zonas de concentración de esfuerzos que conllevan al daño estructural de sus constituyentes y tejidos adyacentes. Se realizó el modelo 3D de la reconstrucción de un archivo TAC de un primer premolar inferior, que incluyó esmalte, dentina, ligamento periodontal y hueso alveolar considerando tres variables: dirección, magnitud y área de la fuerza aplicada. La dirección fue dirigida en tres vectores (vertical, tangencial y horizontal) bajo cuatro magnitudes, una funcional de 35 N y tres disfuncionales de 170, 310 y 445 N, aplicadas sobre un área de la cara oclusal y/o vestibular del premolar que involucró tres contactos estabilizadores (A, B y C) y dos paradores de cierre. Los resultados obtenidos explican el fenómeno de combinar tres vectores, cuatro magnitudes y un área de aplicación de la fuerza, donde los valores de esfuerzo efectivo equivalente Von Mises muestran valores máximos a partir de los 60 MPa. Los valores de tensión máximos se localizan, bajo la carga horizontal a 170 N y en el proceso masticatorio en la zona cervical, cuando la fuerza pasa del 60 %. Sobre la base de los hallazgos de este estudio, se puede concluir que la reacción de los tejidos a fuerzas funcionales y disfuncionales varía de acuerdo con la magnitud, dirección y área de aplicación de la fuerza. Los valores de tensión resultan ser más altos bajo la aplicación de fuerzas disfuncionales tanto en magnitud como en dirección, produciendo esfuerzos tensiles significativos para la estructura dental y periodontal cervical, mientras que, bajo las cargas funcionales aplicadas en cualquier dirección, no se generan esfuerzos lesivos. Esto supone el reconocimiento del poder de detrimento estructural del diente y periodonto frente al bruxismo céntrico y excéntrico.


SUMMARY: The purpose of this study was to analyze the mechanical behavior of the healthy dental structure of a human mandibular first premolar subjected to functional and dysfunctional forces in different directions. It was sought to understand, under the contemplated variables, the areas of stress concentration that lead to structural damage of its constituents and adjacent tissues. The 3D model of the reconstruction of a CT file of a lower first premolar was made, which included enamel, dentin, periodontal ligament and alveolar bone considering three variables: direction, magnitude and area of the applied force. The direction was directed in three vectors (vertical, tangential and horizontal) under four magnitudes, one functional of 35 N and three dysfunctional of 170, 310 and 445 N, applied to an area of the occlusal and/or buccal face of the premolar that involved three stabilizing contacts (A, B and C) and two closing stops. The results obtained explain the phenomenon of combining three vectors, four magnitudes and an area of force application, where the values of effective equivalent Von Mises stress show maximum values from 60 MPa. The maximum tension values are located under the horizontal load at 170 N and in the masticatory process in the cervical area, when the force exceeds 60%. Based on the findings of this study, it can be concluded that the reaction of tissues to functional and dysfunctional forces varies according to the magnitude, direction, and area of application of the force. The stress values turn out to be higher under the application of dysfunctional forces both in magnitude and in direction, producing significant tensile stresses for the dental and cervical periodontal structure, while under functional loads applied in any direction, no damaging stresses are generated. This supposes the recognition of the power of structural detriment of the tooth and periodontium against centric and eccentric bruxism.


Assuntos
Humanos , Dente Pré-Molar/fisiologia , Fenômenos Biomecânicos , Análise de Elementos Finitos , Dente/fisiologia , Força de Mordida , Bruxismo/fisiopatologia , Módulo de Elasticidade , Desgaste dos Dentes , Mastigação/fisiologia
4.
São Paulo; s.n; 20220720. 98 p.
Tese em Português | LILACS, BBO | ID: biblio-1379709

RESUMO

O presente estudo teve como objetivo avaliar o desempenho de quatro resinas bulk fill (Filtek Bulk Fill (FBF), Opus Bulk Fill (OBF), Sonicfill (SF) e Tetric N-Ceram Bulk Fill (TNBF)) e uma resina convencional (Charisma Diamond (CD)) quanto às seguintes propriedades: resistência à flexão (RF), módulo de elasticidade (ME) e dureza Knoop (KHN) em função da profundidade e após a realização de um envelhecimento acelerado. Corpos de prova em formato de barra foram confeccionados simultaneamente em diferentes profundidades (1, 2, 3, 4 e 5 mm) para realização dos testes de resistência à flexão (n=10), módulo de elasticidade (n=10) e dureza Knoop (n=3). Os testes foram realizados em dois momentos, previamente e após a realização de um envelhecimento acelerado, que consistiu na realização de uma termociclagem com banhos alternados em água a 5 e 55ºC, com 1 min de imersão em cada, por 2000 ciclos. Os resultados para o teste de RF e ME mostraram que os valores para estas duas propriedades diminuíram em função da profundidade e após a realização da termociclagem para todas as resinas estudadas. Apenas a resina TNBF não apresentou diferença estatística para valores de ME após o envelhecimento acelerado. Quanto à dureza, os valores também diminuíram em função da profundidade, porém aumentaram após a realização do envelhecimento acelerado. Apenas a resina SF não apresentou diferença estatística entre os valores de dureza antes e após o envelhecimento. A resina convencional CD após a ciclagem térmica foi a única que apresentou relação base/topo (2 mm) acima de 80%. Nenhuma das resinas do tipo bulk fill apresentou uma relação base/topo acima de 80% para a dureza quando avaliadas na espessura máxima recomendada. Com base nos resultados obtidos, pode-se afirmar que, quando fotoativadas na espessura máxima recomendada, apenas a resina convencional CD apresentou resultados condizentes com a homogeneidade esperada em todas as condições deste estudo. Entretanto, para as resinas do tipo bulk fill, pode-se observar que as propriedades estudadas, de modo geral, sofreram uma diminuição significativa em função da profundidade. Para o envelhecimento, a dureza, diferentemente dos outros parâmetros, mostrou uma tendência de aumento.


Assuntos
Envelhecimento , Resinas Compostas , Módulo de Elasticidade , Dureza
5.
Int. j. morphol ; 40(3): 824-831, jun. 2022. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1385651

RESUMO

SUMMARY: Biomechanical factors are important factors in inducing intervertebral disc degeneration, in this paper, the nonlinear viscoelastic mechanical properties of degenerated intervertebral discs were analyzed experimentally. Firstly, the loading and unloading curves of intervertebral discs before and after degeneration at different strain rates were compared to analyze the changes of their apparent viscoelastic mechanical properties; The internal stress/strain distribution of the disc before and after degeneration was then tested by combining digital image technology and fiber grating technology. The results show that the intervertebral disc is strain-rate- dependent whether before or after degeneration; The modulus of elasticity and peak stress of the degenerated disc are significantly reduced, with the modulus of elasticity dropping to 50 % of the normal value and the peak stress decreasing by about 55 %; Degeneration will not change the distribution of the overall internal displacement of the intervertebral disc, but has a greater impact on the superficial and middle AF; The stress in the center of the nucleus pulposus decreases, and the stress in the outer AF increases after degeneration. Degeneration has a great impact on the nonlinear viscoelastic mechanical properties of intervertebral disc, which has reference value for the mechanism, treatment and prevention of clinical degenerative diseases.


RESUMEN: Los factores biomecánicos son importantes en la inducción de la degeneración del disco intervertebral. En este estudio se analizaron experimentalmente las propiedades mecánicas viscoelásticas no lineales de los discos intervertebrales degenerados. En primer lugar se compararon las curvas de carga y descarga de los discos intervertebrales, antes y después de la degeneración, a diferentes velocidades de deformación para analizar los cambios aparentes de sus propiedades mecánicas viscoelásticas. La distribución interna de tensión/deformación del disco antes y después de la degeneración se probó luego combinando tecnología de imagen digital y tecnología de rejilla de fibra. Los resultados mostraron que el disco intervertebral depende de la velocidad de deformación antes o después de la degeneración; El módulo de elasticidad y la tensión máxima del disco degenerado se reducen significativamente, cayendo el módulo de elasticidad al 50 % del valor normal y la tensión máxima disminuyendo en aproximadamente un 55 %; La degeneración no cambiará la distribución del desplazamiento interno general del disco intervertebral, pero tiene un mayor impacto en la FA superficial y media; El estrés en el centro del núcleo pulposo disminuye y el estrés en el FA externo aumenta después de la degeneración. La degeneración tiene un gran impacto en las propiedades mecánicas viscoelásticas no lineales del disco intervertebral, que tiene valor de referencia para el mecanismo, tratamiento y prevención de enfermedades clínicas degenerativas.


Assuntos
Estresse Mecânico , Viscosidade , Dinâmica não Linear , Degeneração do Disco Intervertebral , Fenômenos Biomecânicos , Módulo de Elasticidade , Modelos Biológicos
6.
Sheng Li Xue Bao ; (6): 894-902, 2022.
Artigo em Chinês | WPRIM | ID: wpr-970085

RESUMO

Cardiovascular homeostasis is regulated by both physical and chemical factors. Vascular stiffness, a physical property of vessel, is crucial in maintaining the physiological function of vasculature. Vascular stiffness has been indicated to be correlated with hypertension, heart failure and other cardiovascular diseases. It has been the most widely accepted clinical index for assessment of vascular function and dysfunction. This paper reviews the commonly used experimental and clinical techniques for evaluating vascular stiffness including direct detection of the Young's modulus and indirect detection method that is based on ultrasound technique and others. Principles of these methodologies, as well as their advantages and disadvantages, are also presented here. Researchers and clinical staff are encouraged to choose the most suitable methods for detecting vascular stiffness according to their purposes and objects, so as to effectively evaluate vascular function.


Assuntos
Humanos , Rigidez Vascular , Módulo de Elasticidade , Hipertensão/diagnóstico , Doenças Cardiovasculares/diagnóstico , Insuficiência Cardíaca
7.
Braz. dent. sci ; 25(1): 1-8, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-1361498

RESUMO

Objective: To evaluate the influence of the incorporation of a polymerization catalyst to a light-cured pulp capping material on mechanical behavior and physicochemical characteristics. Material and Methods: Different percentages (2 wt%, and 4 wt%) of diphenyliodonium hexafluorophosphate (DPI) were incorporated into the Ultra-Blend Plus, a resin-modified calcium-based cement. The material without incorporation of DPI (0 wt%) served as control. Degree of Conversion (DC), Flexural Strength (FS), Elastic Modulus (EM), Water Sorption (WSp), Solubility (Sl), and pH of eluate at 24-h, 72-h, and 7-day storage times were measured. One-way ANOVA/Tukey posthoc tests were used to analyze the data (p <0.05). Results: For DC, FS, and EM, materials with different % of DPI showed statistically significant differences, so that 0% provided the lowest values and 2% the highest values. Materials with 0% and 2% of DPI provided statistically the lowest WSp, whilst material with 0% of DPI showed statistically the highest Sl. Conclusion: All materials provided statistically similar pH to eluates regardless of storage time, although only materials with DPI at 2% and 4% maintained pH of eluates statistically similar from 72 h to 7 days storage times.(AU)


Objetivo: avaliar a influência nas propriedades mecânicas e físico-químicas da incorporação de um catalisador de polimerização a um protetor pulpar fotoativável. Material e Métodos: foram adicionadas diferentes porcentagens em massa (2% e 4%) de hexafluorofosfato de difeniliodônio (DPI) ao Ultra-Blend Plus, um cimento à base de hidróxido de cálcio modificado por resina. O material sem a adição do DPI (0%) serviu como controle. Foram avaliados: Grau de Conversão (DC), Resistência Flexural (FS), Módulo de Elasticidade (EM), Sorção (WSp), Solubilidade (SI) e o pH do eluato nos tempos de 24h, 72h e 7 dias de armazenamento. ANOVA 1-way com pós-teste de Tukey (p <0.05). Foi utilizado para avaliar os resultados estatisticamente. Resultados: Os materiais com diferentes % de DPI apresentaram diferenças significativas para os testes de DC, FS e EM. A porcentagem em massa de 0% de DPI mostrou valores inferiores a todos os testados e os materiais com adição 2% apresentaram a melhor performance. Materiais com 0% e 2% de DPI apresentaram valores inferiores de WSp; a porcentagem de 0% proporcionou valores estatisticamente maiores para SI. Conclusão: Todos os materiais testados apresentaram pH semelhante nos eluatos independente do tempo de armazenamento, contudo, apenas os materiais com 2% e 4% mantiveram o pH dos eluatos estatisticamente similares nos tempos de estocagem de 72h a 7 dias.(AU)


Assuntos
Capeamento da Polpa Dentária , Módulo de Elasticidade , Polimerização , Solubilidade
8.
Rev. cuba. invest. bioméd ; 40(4)dic. 2021. ilus, tab
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1408590

RESUMO

Objetivo: Comparar el módulo de elasticidad y resistencia de la resina acrílica de termocurado y la resina flexible superpoliamida. Métodos: Se diseñó un estudio experimental que empleó dos tipos de resinas acrílicas preparadas en cera para obtener una forma rectangular de 64 mm de largo, 10 mm de ancho y 2,5 mm de grosor, pasadas a acrílico de termocurado y resina flexible superpoliamida. Se emplearon 10 bloques de resina acrílica de cada tipo sometidas a compresión por la máquina de ensayos universal, que generó una fuerza de aproximación de 0,001 N sobre los bloques con un avance de 0,01 mm/min. El módulo de resistencia y el módulo de elasticidad se analizaron mediante la prueba de flexión de tres puntos. Resultados: El módulo de elasticidad de la resina acrílica de termocurado fue de 2501,83 ± 139,42, mientras que el módulo de resistencia fue de 78,36 ± 11,69 MPa. Por otro lado, el módulo de elasticidad de la resina flexible superpoliamida fue de 1020,59 ± 92,95, mientras que el módulo de resistencia fue de 36,04 ± 2,71 MPa. El módulo de elasticidad de la resina acrílica de termocurado fue mayor al de la resina flexible superpoliamida, esta diferencia fue de 1481,24 MPa. El módulo de resistencia de la resina acrílica de termocurado fue mayor al de la resina flexible superpoliamida. Conclusiones: Se concluyó que el módulo de elasticidad (rigidez) y resistencia fue mayor en la resina acrílica de termocurado en comparación a la resina flexible superpoliamida(AU)


Objective: Compare the module of elasticity and resistance of thermal curing acrylic resin and flexible superpolyamide resin. Methods: An experimental study was conducted of two types of acrylic resins molded in wax to obtain a 64 mm long, 10 mm wide and 2.5 mm thick rectangular shape, and then transferred to thermal curing acrylic resin and flexible superpolyamide resin. Ten acrylic resin blocks of each type were used. The blocks were compressed by the universal testing machine, which generated an approximation force of 0.001 N on the blocks at a forward speed of 0.01 mm/min. The resistance module and the elasticity module were analyzed with the three point flexural test. Results: The elasticity module of the thermal curing acrylic resin was 2501.83 ± 139.42, whereas the resistance module was 78.36 ± 11.69 MPa. The elasticity module of the flexible superpolyamide resin was 1020.59 ± 92,95, whereas the resistance module was 36.04 ± 2.71 MPa. The elasticity module of the thermal curing acrylic resin was greater than that of the flexible superpolyamide resin, the difference being 1481.24 MPa. The resistance module of the thermal curing acrylic resin was greater than that of the flexible superpolyamide resin. Conclusions: The elasticity (rigidity) and resistance module was greater in the thermal curing acrylic resin than in the flexible superpolyamide resin(AU)


Assuntos
Humanos , Resinas Acrílicas , Módulo de Elasticidade , Técnicas In Vitro , Estudos Transversais , Estudos Prospectivos , Estudos de Avaliação como Assunto
9.
Int. j. odontostomatol. (Print) ; 15(1): 226-233, mar. 2021. graf, tab
Artigo em Inglês | LILACS | ID: biblio-1385707

RESUMO

This study aims to evaluate the physical, chemical, mechanical and optical properties of Bulk-Fill resin, in relation to the literature and its proper clinical uses. A bibliographic search was performed in the main health databases PUBMED (www.pubmed.gov) and Scholar Google (www.scholar.google.com.br), in which articles published from 1994 to 2020 were collected. Laboratory studies, case reports, systematic reviews and literature reviews, which were developed in living individuals, were included. Therefore, articles that did not deal with the characteristics of the Bulk-Fill resin and its proper clinical uses were excluded. The use of Bulk-Fill resin has been progressively increasing over the years, presenting good properties, achieving success in clinical performance, ease of handling and thus has become the material of choice for dentists. In addition, its longevity demonstrates durability with mechanical properties and resistance to tooth structure. Bulk - Fill resins have characteristics similar to traditional composite resins, when performed according the usage protocol. With the use of this group of resins in a single increment, possible failures that occur during the restorative procedure can be minimized, such as: less chance of incorporating bubbles and a volumetric contraction with less stress on the interface.


Este estudio tuvo como objetivo evaluar las propiedades físicas, químicas, mecánicas y ópticas de la resina Bulk-Fill, en relación con la literatura y sus usos clínicos apropiados. Realizamos una búsqueda bibliográfica en las bases de datos de salud PUBMED (www.pubmed.gov) y Scholar Google (www.scholar.google.com.br), en la que se recopilaron trabajos que se publicaron entre 1994 y 2020. Fueron incluidos estudios de laboratorio, informes de casos, revisiones sistemáticas y revisiones de literatura, desarrollados en individuos vivos. Por tanto, se excluyeron los artículos que no trataban las características de la resina Bulk-Fill y sus usos clínicos adecuados. El uso de la resina Bulk-Fill ha ido aumentando progresivamente a lo largo de los años, presentando buenas propiedades, logrando éxito en el rendimiento clínico, facilidad de manejo y, por lo tanto, se ha convertido en el material elegido por los dentistas. Además, su longevidad demuestra durabilidad, con propiedades mecánicas y resistencia a la estructura dental.Las resinas Bulk-Fill tienen características similares a las resinas compuestas tradicionales, cuando se realizan siguiendo el protocolo de uso. Con el uso de este grupo de resinas mono incremental, es posible eliminar el paso de varios incrementos, disminuyendo a su vez el tiempo clínico. Además, se pueden minimizar las posibles fallas que se producen durante el procedimiento de restauración, tales como: menos posibilidades de incorporar burbujas y una contracción volumétrica con menos estrés en la interfaz.


Assuntos
Resinas Compostas , Resistência à Flexão , Estresse Mecânico , Propriedades de Superfície , Teste de Materiais , Módulo de Elasticidade , Polimerização
10.
Artigo em Chinês | WPRIM | ID: wpr-880413

RESUMO

Osteoporosis is one of the common metabolic diseases, which can easily lead to osteoporotic fractures. Accurate prediction of bone biomechanical properties is of great significance for the early prevention and diagnosis of osteoporosis. Bone mineral density measurement is currently used clinically as the gold standard for assessing bone strength and diagnosing osteoporosis, but studies have shown that bone mineral density can only explain 60% to 70% of bone strength changes, and trabecular bone microstructure is an important factor affecting bone strength. In order to establish the connection between trabecular bone microstructure and bone strength, this paper proposes a prediction method of trabecular bone modulus based on SE-DenseVoxNet. This method takes three-dimensional binary images of trabecular bone as input and predicts its elastic modulus in the z-axis direction. Experiments show that the error and bias between the predicted value of the method and the true value of the sample are small and have good consistency.


Assuntos
Humanos , Fenômenos Biomecânicos , Densidade Óssea , Osso Esponjoso/diagnóstico por imagem , Módulo de Elasticidade , Osteoporose/diagnóstico por imagem
11.
Araçatuba; s.n; 2021. 137 p. ilus, graf, tab.
Tese em Inglês, Português | LILACS, BBO | ID: biblio-1436158

RESUMO

O objetivo deste estudo in vitro foi avaliar o efeito da aplicação de agentes antioxidantes após o clareamento dentário e previamente à cimentação de laminados cerâmicos na estabilidade cromática do conjunto restaurador, assim como nas propriedades mecânicas de nanodureza (HIT), módulo de elasticidade (Eit*), grau de conversão, resistência de união e morfologia da interface adesiva. Ademais, a neutralização de peróxido de hidrogênio e a caracterização superficial do esmalte, como ângulo de contato, energia de superfície, energia livre total de interação, microscopia eletrônica de varredura e espectroscopia de energia dispersiva do substrato submetido à ação das soluções antioxidantes e do agente clareador também foram analisados. Duzentos e quarenta e dois blocos de esmalte dentário (7x8x0,6mm) foram utilizados para o processo de cimentação e distribuídos em grupos experimentais de acordo com os métodos de procedimentos (grupo não clareado, grupo clareado com Whiteness HP Maxx 35%), tipos de antioxidantes adotados (controle; ácido ascórbico 10% e α-tocoferol 10%) e períodos de cimentação (após 24 horas e 14 dias do processo de cimentação) (n = 22). Foi utilizado o sistema adesivo Tetric N Bond Universal e o cimento resinoso Variolink Esthetic LC (Ivoclar Vivadent) como agentes cimentantes. Os dados foram submetidos a testes estatísticos de normalidade e analisados por ANOVA e teste de Tukey (α = 0,05). Os dados da morfologia da interface adesiva, obtidas pela microscopia confocal a laser, foram submetidas ao teste Kappa inter-examinadores e os dados foram submetidos aos testes Kruskal-Wallis e Dunn (α = 0,05). Os resultados mostraram que, de modo geral, a utilização da solução antioxidante α-tocoferol 10% pós-clareamento no período mediato promoveu resultados satisfatórios com relação à estabilidade cromática do conjunto restaurador, assim como para as propriedades mecânicas, grau de conversão, resistência de união e morfologia da interface adesiva comparado ao grupo clareado sem associação dos agentes antioxidantes, tanto para o período mediato, quanto para o período de 14 dias (p< 0,05). A solução de αtocoferol 10% apresentou maiores valores de neutralização do peróxido de hidrogênio e maiores valores de molhabilidade do esmalte em relação aos grupos controle e ácido ascórbico (p< 0,05). A energia de superfície e energia livre total de interação do esmalte dentário foi significativamente influenciada pelo tratamento clareador (p< 0,05). Dessa forma, conclui-se que o emprego da solução antioxidante α-tocoferol 10% promoveu resultados promissores, sugerindo que o mesmo poderia ser utilizado mediatamente após o clareamento dental na cimentação de laminados cerâmicos(AU)


The aim of this in vitro study was to evaluate the effect of antioxidant agents application after tooth bleaching and prior to luting of ceramic veneers on color stability of the restorative set, as well as on mechanical properties of nanohardness (HIT), elastic modulus (Eit*), degree of conversion, bond strength and morphology of the adhesive interface. Furthermore, the hydrogen peroxide neutralization and surface characterization of enamel, such as contact angle, surface energy, total free energy of interaction, scanning electron microscopy and energy-dispersive spectroscopy of the substrate submitted to the action of antioxidant solutions and bleaching agent were also analyzed. Two hundred forty two dental enamel blocks (7 x 8 x 0.6 mm) were used for the luting process and distributed into experimental groups according to the procedure methods (unbleached group, bleached group with Whiteness HP Maxx 35%), types of antioxidants adopted (control; 10% ascorbic acid and 10% α-tocopherol) and the luting periods (24 hours and 14 days after the luting process) (n = 22). Tetric N Bond Universal adhesive system and Variolink Esthetic LC resin cement (Ivoclar Vivadent) were used as luting agents. Data were submitted to statistical tests of normality and analyzed by ANOVA and Tukey tests (α = 0.05). The adhesive interface morphology data, obtained by confocal laser microscopy, were submitted to the interexaminer Kappa test and the data were submitted to Kruskal-Wallis and Dunn´s tests (α = 0.05). The results showed that, in general, the use of 10% α-tocopherol antioxidant solution after bleaching in mediate period promoted satisfactory results regarding the color stability of the restorative set, as well as for the mechanical properties, degree of conversion, shear bond strength and adhesive interface morphology compared to the bleached group without antioxidant agents association, both for the mediate and 14-day period (P < 0.05). The 10% αtocopherol solution showed higher hydrogen peroxide neutralization values and higher enamel wettability values compared to the control and ascorbic acid groups (P < 0.05). Surface energy and total free energy of interaction of tooth enamel were significantly influenced by the bleaching treatment (P < 0.05). Thus, it is concluded that the use of 10% αtocopherol antioxidant solution promoted promising results, suggesting that it could be used mediately after tooth bleaching on luting of ceramic laminates(AU)


Assuntos
Clareamento Dental , Cerâmica , Cimentação , Antioxidantes , Ácido Ascórbico , Espectrometria por Raios X , Propriedades de Superfície , Estresse Oxidativo , Cimentos de Resina , Tocoferóis , Cimentos Dentários , Esmalte Dentário , Resistência ao Cisalhamento , Módulo de Elasticidade , Dureza , Peróxido de Hidrogênio
12.
Zhongguo yi xue ke xue yuan xue bao ; Zhongguo yi xue ke xue yuan xue bao;(6): 190-196, 2020.
Artigo em Chinês | WPRIM | ID: wpr-826383

RESUMO

To explore the value of conventional ultrasound combined with shear-wave elastography in the quantitative evaluation of sciatic nerve crush injury in rabbit models. Forty healthy male New Zealand white rabbits were randomly divided into four groups (=10 in each group):three crush injury (CI) groups (2,4,and 8 weeks after crush) and control group (without injury). The thickness and stiffness of the crushed sciatic nerves and denervated triceps surae muscles were measured at different time points and compared with histopathologic parameters. Inter-reader variability was assessed with intraclass correlation coefficients. Compared with the control group,the inner diameters of the sciatic nerves significantly increased in the 2-week CI group [(1.65±0.34) mm (0.97±0.15) mm,=0.00] but recovered to the nearly normal level in the 8-week CI group [(1.12±0.18) mm (0.97±0.15) mm,=0.06];however,compared with control group [(8.75±1.02)kPa],the elastic modulus of the nerves increased significantly in all the CI groups [2-week:(14.77±2.53) kPa;4-week:(19.12±3.46) kPa;and 8-week:(28.39±5.26) kPa;all =0.00];pathologically,massive hyperplasia of collagen fibers were found in the nerve tissues. The thickness of denervated triceps surae muscle decreased gradually,and the elastic modulus decreased 2 weeks after injury but increased gradually in the following 6 weeks;pathologically,massive hyperplasia of collagen fibers and adipocytes infiltration were visible,along with decreased muscle wet-weight ratio and muscle fiber cross-sectional area. The inter-reader agreements were good. Conventional ultrasound combined with shear-wave elastography is feasible for the quantitative evaluation of the morphological and mechanical properties of crushed nerves and denervated muscles.


Assuntos
Animais , Masculino , Coelhos , Lesões por Esmagamento , Diagnóstico por Imagem , Módulo de Elasticidade , Técnicas de Imagem por Elasticidade , Músculo Esquelético , Patologia , Distribuição Aleatória , Nervo Isquiático , Ferimentos e Lesões , Ultrassonografia
14.
Rev. bras. pesqui. méd. biol ; Braz. j. med. biol. res;53(11): e10058, 2020. graf
Artigo em Inglês | LILACS, ColecionaSUS | ID: biblio-1132498

RESUMO

This study aimed to explore changes in nanoscale elastic modulus of the synovium using atomic force microscopy (AFM) in addition to investigate changes in synovial histomorphology and secretory function in osteoarthritis (OA) in a rat anterior cruciate ligament transection (ACLT) model. Sprague-Dawley rats were randomly assigned to sham control and ACLT OA groups. All right knee joints were harvested at 4, 8, or 12 weeks (W) after surgery for histological assessment of cartilage damage and synovitis in both the anterior and posterior capsules. AFM imaging and nanoscale biomechanical testing were conducted to measure the elastic modulus of the synovial collagen fibrils. Immunohistochemistry was used to visualize the expression of interleukin-1β (IL-1β), tumor necrosis factor-α (TNF-α), and matrix metalloproteinase-3 (MMP-3) in the synovium. The OA groups exhibited progressive development of disease in the cartilage and synovium. Histopathological scores of the synovium in the OA groups increased gradually. Significant differences were observed between all OA groups except for the posterior 4W group. The synovial fibril arrangement in all OA groups was significantly disordered. The synovial fibrils in all ACLT OA groups at each time point were stiffer than those in the sham controls. OA rats displayed a significantly higher expression of IL-1β and MMP3 in the anterior capsule. In summary, synovial stiffening was closely associated with joint degeneration and might be a factor contributing to synovitis and increased production of proinflammatory mediators. Our data provided insights into the role of synovitis, particularly stiffening of the synovium, in OA pathogenesis.


Assuntos
Animais , Masculino , Ratos , Osteoartrite , Cartilagem Articular , Membrana Sinovial , Ligamento Cruzado Anterior , Ratos Sprague-Dawley , Microscopia de Força Atômica , Módulo de Elasticidade
15.
Braz. oral res. (Online) ; 34: e099, 2020. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-1132660

RESUMO

Abstract The composition of infiltrants can influence their physical properties, viscosity and depth of penetration (DP). Strategies are used to increase the DP, such as the addition of diluents or the use of heat. This study aimed to evaluate the effect of preheating and composition on physical properties and DP of infiltrants in demineralized enamel. The groups were assigned, and the following experimental formulations were made: 25%BisEMA +75%TEGDMA; 25%BisEMA +65%TEGDMA +10%ethanol; 25%BisEMA +65%TEGDMA +10%HEMA; 100%TEGDMA; 90%TEGDMA +10%ethanol; 90%TEGDMA +10%HEMA. The samples were photoactivated at two temperatures (25°C and 55°C). Degree of conversion (DC) was performed using an infrared spectrophotometer. Elastic modulus (E), flexural strength (FS) and contact angle (CA) tests were also performed. The DP of an infiltrant in demineralized enamel was determined by confocal laser scanning microscopy (CLSM) using an indirect labeling technique. The data were analyzed by two-way ANOVA and Tukey's test. DC increased after preheating in all the groups; however, 90%TEGDMA+10%ethanol showed the lowest DC for both temperatures, and the lowest E. Preheating did not influence E or FS. The CA increased at 55°C for most groups, but decreased for groups containing HEMA. Temperature did not seem to influence DP, and Icon showed the lowest DP values. The 100%TEGDMA composition showed more homogeneous penetration, whereas Icon showed heterogeneous and superficial penetration. The preheating technique does not improve all properties in all the material compositions. The composition of a material can influence and improve its properties.


Assuntos
Esmalte Dentário , Polietilenoglicóis , Ácidos Polimetacrílicos , Viscosidade , Teste de Materiais , Bis-Fenol A-Glicidil Metacrilato , Resinas Compostas , Módulo de Elasticidade , Metacrilatos
16.
Clinics ; Clinics;75: e1691, 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1133437

RESUMO

OBJECTIVE: Imaging diagnosis of cervical lymphadenopathy has conventionally used ultrasonography. Shear wave elastography (SWE) is a recent ultrasound technological advancement that has shown promise in the important medical problem of differentiating between benign and malignant cervical lymph nodes based on quantitative measurements of elasticity modulus. However, widely varying elasticity modulus metrics and regions-of-interest (ROIs) were used in existing studies, leading to inconsistent findings and results that are hard to compare with each other. METHODS: Using a large dataset of 264 cervical lymph nodes from 200 patients, we designed a study comparing three elasticity modulus metrics (Emax, Emean, and standard deviation-SD) with three different ROIs to evaluate the effect of such selections. The metric values were compared between the benign and malignant node groups. The different ROI and metric selections were also compared through receiver operating characteristics curve analysis. RESULTS: For all ROIs, all metric values were significantly different between the two groups, indicting their diagnostic potential. This was confirmed by the ≥0.80 area under the curve (AUC) values achieved with these metrics. Different ROIs had no effect on Emax, whereas all ROIs achieved high performance at 0.88 AUC. For Emean, the smallest ROI focusing on the area of the highest elasticity achieved the best diagnostic performance. In contrast, the larger ROIs achieved higher performances for SD. CONCLUSIONS: This study illustrated the effect of elasticity modulus and ROI selection on the diagnostic performance of SWE on cervical lymphadenopathy. These new findings help guide relevant future studies and clinical applications of this important quantitative imaging modality.


Assuntos
Humanos , Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Reprodutibilidade dos Testes , Ultrassonografia , Sensibilidade e Especificidade , Diagnóstico Diferencial , Módulo de Elasticidade , Linfonodos/diagnóstico por imagem , Pescoço/diagnóstico por imagem
17.
J. appl. oral sci ; J. appl. oral sci;28: e20190544, 2020. tab, graf
Artigo em Inglês | LILACS, BBO | ID: biblio-1101250

RESUMO

Abstract Objective To evaluate the influence of three levels of dental structure loss on stress distribution and bite load in root canal-treated young molar teeth that were filled with bulk-fill resin composite, using finite element analysis (FEA) to predict clinical failure. Methodology Three first mandibular molars with extensive caries lesions were selected in teenager patients. The habitual occlusion bite force was measured using gnathodynamometer before and after endodontic/restoration procedures. The recorded bite forces were used as input for patient-specific FEA models, generated from cone-beam computed tomographic (CT) scans of the teeth before and after treatment. Loads were simulated using the contact loading of the antagonist molars selected based on the CT scans and clinical evaluation. Pre and post treatment bite forces (N) in the 3 patients were 30.1/136.6, 34.3/133.4, and 47.9/124.1. Results Bite force increased 260% (from 36.7±11.6 to 131.9±17.8 N) after endodontic and direct restoration. Before endodontic intervention, the stress concentration was located in coronal tooth structure; after rehabilitation, the stresses were located in root dentin, regardless of the level of tooth structure loss. The bite force used on molar teeth after pulp removal during endodontic treatment resulted in high stress concentrations in weakened tooth areas and at the furcation. Conclusion Extensive caries negatively affected the bite force. After pulp removal and endodontic treatment, stress and strain concentrations were higher in the weakened dental structure. Root canal treatment associated with direct resin composite restorative procedure could restore the stress-strain conditions in permanent young molar teeth.


Assuntos
Humanos , Criança , Força de Mordida , Resinas Compostas/química , Dente não Vital/terapia , Restauração Dentária Permanente/métodos , Dente Molar , Valores de Referência , Resistência à Tração , Reprodutibilidade dos Testes , Resultado do Tratamento , Resinas Compostas/uso terapêutico , Dente não Vital/diagnóstico por imagem , Força Compressiva , Análise de Elementos Finitos , Análise do Estresse Dentário , Tomografia Computadorizada de Feixe Cônico , Módulo de Elasticidade , Modelagem Computacional Específica para o Paciente
19.
Artigo em Inglês | WPRIM | ID: wpr-1010471

RESUMO

In maxillofacial surgery, there is a significant need for the design and fabrication of porous scaffolds with customizable bionic structures and mechanical properties suitable for bone tissue engineering. In this paper, we characterize the porous Ti6Al4V implant, which is one of the most promising and attractive biomedical applications due to the similarity of its modulus to human bones. We describe the mechanical properties of this implant, which we suggest is capable of providing important biological functions for bone tissue regeneration. We characterize a novel bionic design and fabrication process for porous implants. A design concept of "reducing dimensions and designing layer by layer" was used to construct layered slice and rod-connected mesh structure (LSRCMS) implants. Porous LSRCMS implants with different parameters and porosities were fabricated by selective laser melting (SLM). Printed samples were evaluated by microstructure characterization, specific mechanical properties were analyzed by mechanical tests, and finite element analysis was used to digitally calculate the stress characteristics of the LSRCMS under loading forces. Our results show that the samples fabricated by SLM had good structure printing quality with reasonable pore sizes. The porosity, pore size, and strut thickness of manufactured samples ranged from (60.95± 0.27)% to (81.23±0.32)%, (480±28) to (685±31) μm, and (263±28) to (265±28) μm, respectively. The compression results show that the Young's modulus and the yield strength ranged from (2.23±0.03) to (6.36±0.06) GPa and (21.36±0.42) to (122.85±3.85) MPa, respectively. We also show that the Young's modulus and yield strength of the LSRCMS samples can be predicted by the Gibson-Ashby model. Further, we prove the structural stability of our novel design by finite element analysis. Our results illustrate that our novel SLM-fabricated porous Ti6Al4V scaffolds based on an LSRCMS are a promising material for bone implants, and are potentially applicable to the field of bone defect repair.


Assuntos
Humanos , Ligas , Biônica , Substitutos Ósseos/química , Osso e Ossos/patologia , Força Compressiva , Módulo de Elasticidade , Análise de Elementos Finitos , Lasers , Teste de Materiais , Implante de Prótese Maxilofacial , Porosidade , Pressão , Impressão Tridimensional , Próteses e Implantes , Desenho de Prótese , Estresse Mecânico , Cirurgia Bucal/instrumentação , Engenharia Tecidual/métodos , Titânio/química
20.
Ultrasonography ; : 37-43, 2019.
Artigo em Inglês | WPRIM | ID: wpr-731043

RESUMO

PURPOSE: The purpose of this study was to investigate the feasibility of shear wave ultrasound elastography for differentiating superficial benign soft tissue masses through a comparison of their shear moduli. METHODS: We retrospectively analyzed 48 masses from 46 patients from February 2014 to May 2016. Surgical excision, fine-needle aspiration, and clinical findings were used for the differential diagnosis. The ultrasonographic examinations were conducted by a single musculoskeletal radiologist, and the ultrasonographic findings were reviewed by two other radiologists who were blinded to the final diagnosis. Conventional ultrasonographic features and the median shear modulus were evaluated. We compared the median shear moduli of epidermoid cysts, ganglion cysts, and lipomatous tumors using the Kruskal-Wallis test. Additionally, the Mann-Whitney U test was used to compare two distinct groups. RESULTS: Significant differences were found in the median shear moduli of epidermoid cysts, ganglion cysts, and lipomatous tumors (23.7, 5.8, and 9.2 kPa, respectively; P=0.019). Epidermoid cysts showed a greater median shear modulus than ganglion cysts (P=0.014) and lipomatous tumors (P=0.049). CONCLUSION: Shear wave elastography may contribute to the differential diagnosis of superficial benign soft tissue masses through a direct quantitative analysis.


Assuntos
Humanos , Biópsia por Agulha Fina , Diagnóstico , Diagnóstico Diferencial , Módulo de Elasticidade , Técnicas de Imagem por Elasticidade , Cisto Epidérmico , Cistos Glanglionares , Lipoma , Estudos Retrospectivos , Resistência ao Cisalhamento , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA