1.
J. coloproctol. (Rio J., Impr.) ; 41(1): 70-78, Jan.-Mar. 2021. tab
Artigo em Inglês | LILACS | ID: biblio-1286965

RESUMO

Abstract Introduction The present study aims to identify normal high-resolution anorectal manometry (HRAM) values and related factors in healthy Vietnamese adults. Methods The present cross-sectional study was conducted at the Viet Duc hospital, Hanoi, Vietnam, during April and May 2019. Healthy volunteers were recruited to participate in the study. Anorectal measurement values from the digestive tract, including pressure, were recorded. Results A total of 76 healthy volunteers were recruited. The mean functional anal canal length was 4.2 ± 0.5 cm, while the mean anal high-pressure zone length was 3.4 ± 0.5 cm. Themean defecation index was 1.4 ± 0.8, with values ranging from 0.3 to 5.0. The mean threshold volume to elicit the rectoanal inhibitory reflex (RAIR) was 18.1 mL. The mean rectal sensation values were 32.4mL, 81.6mL, and 159 mL for first sensation, desire to defecate, and urge to defecate, respectively. Dyssynergic patterns occurred in ~ 50% of the study participants and included mainly types I (27.6%) and III (14.6%). There were significant differences between male and female patients in terms of maximum anal squeeze pressure, maximum anal cough pressure, maximum anal strain pressure, maximum rectal cough pressure, and maximum rectal strain pressure (all p<0.01). Conclusions The present study establishes normal HRAM values in healthy Vietnamese adults, particularly regarding normal values of anorectal pressure and rectal sensation. Further studies that include larger sample sizes should be conducted to further confirm the constants and their relationships.


Resumo Introdução O presente estudo tem como objetivo identificar valores normais de manometria anorretal de alta resolução e fatores relacionados em adultos vietnamitas saudáveis. Métodos O presente estudo transversal foi conduzido no hospital Viet Duc, Hanói, Vietnã, durante abril e maio de 2019. Voluntários saudáveis foram recrutados para participar do estudo. Valores de medição anorretal, incluindo pressão do trato digestivo, foram registrados. Resultados Um total de 76 voluntários saudáveis foram recrutados. O comprimento funcional médio do canal anal foi de 4,2 ± 0,5 cm, enquanto o comprimento médio da zona anal de alta pressão foi de 3,4 ± 0,5 cm. O índice médio de defecação foi de 1,4 ± 0,8, com valores variando de 0,3 a 5,0. O volume limite médio para eliciar o reflexo inibitório retoanal (RAIR, sigla em inglês) foi de 18,1 mL. Os valores médios da sensação retal foram 32,4mL, 81,6mL e 159 mL para a primeira sensação, o desejo de defecar e a urgência de defecar, respectivamente. Os padrões dissinérgicos ocorreram em aproximadamente 50% dos participantes do estudo e incluíram principalmente os tipos I (27,6%) e III (14,6%). Houve diferenças significativas entre homens e mulheres na pressão de compressão anal máxima, pressão de tosse anal máxima, pressão de distensão anal máxima, pressão de tosse retal máxima e pressão de distensão retal máxima (todos p<0,01). Conclusões O presente estudo estabelece valores normais de HRAM em adultos vietnamitas saudáveis, particularmente no que diz respeito aos valores normais de pressão anorretal e sensação retal. Mais estudos que incluam tamanhos de amostra maiores devemser realizados a fim de confirmar melhor as constantes e suas relações.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Canal Anal/anatomia & histologia , Manometria/normas , Manometria/estatística & dados numéricos
2.
Arq. gastroenterol ; 57(2): 209-215, Apr.-June 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1131658

RESUMO

ABSTRACT BACKGROUND: The high-resolution manometry has been a significant advance in esophageal diagnostics. There are different types of catheter and systems devices to capture esophageal pressures that generate variable data related to Chicago Classification (CC) and consequently influence normal values results. There are not normative data for the 24-channel water-perfused high-resolution manometry system most used in Brazil with healthy volunteers in supine posture. OBJECTIVE: To determine manometric esophageal normative values for a 24-channel water-perfused high-resolution manometry catheter in supine posture using healthy volunteers according to CC 3.0 parameters. METHODS: A total of 92 volunteers with no gastrointestinal symptoms or medications affecting GI motility underwent esophageal high-resolution manometry by standard protocol. Age, gender and manometry parameters analyzed using Alacer software were collected. The median, range, and 5th and 95th percentiles (where applicable) were obtained for all high-resolution manometry metrics. Normal value percentiles were defined as 95th integrated relaxation pressure, 5th-100th distal contractile integral, and 5th distal latency. RESULTS: The mean age was 40.5±13.2 years. Our normative metrics were integrated relaxation pressure <16 mmHg and distal contractile integral (708-4111 mmHg.cm.s) distal latency was <6 s and peristaltic break size (>4 cm). For EGJ-CI the range 5th-95th was 21.7-86.9 mmHg.cm.s. CONCLUSION: This is the first report of normative data for the 24-channel water-perfused system in supine posture. It revealed higher integrated relaxation pressure and distal latency duration which suggest the need to change CC 3.0 cutoffs for this system. It is observed that there is a tendency that DCI >7000 mmHg.cm.s may represent the lower limit of hypercontractility, and when <700 mmHg.cm.s (<5% percentile) interpreted as ineffective esophageal motility or failcontraction. Also compared to Chicago 3.0, higher integrated relaxation pressure and duration of distal latency were found. We emphasize that these data must be confirmed by future studies.


RESUMO CONTEXTO: A manometria de alta resolução tem sido um avanço significativo nos diagnósticos esofágicos. Existem diferentes tipos de cateteres e sistemas dispositivos para capturar pressões esofágicas que geram dados variáveis relacionados à Classificação de Chicago (CC) e, consequentemente, podem influenciar os resultados de valores da normalidade. Não há dados normativos com voluntários saudáveis na postura supina, para o sistema manométrico sob perfusão em água de 24 canais, o mais utilizado no Brasil. OBJETIVO: Determinar os valores normativos manométricos do esôfago para um cateter sob perfusão de alta resolução de 24 canais na postura supina utilizando-se voluntários saudáveis assintomáticos de acordo com os parâmetros CC. MÉTODOS: Um total de 92 voluntários sem sintomas gastrointestinais ou medicamentos que afetassem a motilidade gastrointestinal foram submetidos à manometria de alta resolução do esôfago por protocolo padrão (Sistema Alacer Multiplex). Foram coletados parâmetros de idade, sexo e os da manometria analisados pelo software Alacer versão 6.2. A mediana, os limites, e 5% e 95% percentis (quando aplicável) foram obtidos para todas as métricas de alta resolução. Os valores normais foram definidos como percentis de 95% da integral da pressão de relaxamento (IRP), 5%-100% da integral contrátil distal (DCI), e 5% latência distal. RESULTADOS: A média de idade foi de 40,5±13,2 anos. As métricas normativas foram definidas como IRP <16 mmHg) e DCI (708-4111 mmHg.cm.s). Para a latência distal foi de 5,8-9,9 s (faixa: 5,3-10,7s). O comprimento total de quebra na contração esofágica foi de 4,0 cm (faixa: 0,1-6,8 cm). Para a EGJ-CI a faixa 5%-95% percentis foi de 21,7-86,9 mmHg.cm.s. CONCLUSÃO: Este é o primeiro relatório de dados normativos para o sistema de 24 canais perfundido por água na postura supina. A partir dos dados encontrados observa-se a possibilidade de alterar os cortes CC 3.0 para este sistema. Observa-se que há uma tendência que DCI >7000 mmHg.cm.s possa representar o limite inferior da hipercontratilidade e quando <700 mmHg.cm.s (<5% percentil) interpretada como motilidade esofágica ineficaz ou contração falha. Também em comparação com Chicago 3.0, foi encontrada maior pressão de relaxamento integrado e duração da latência distal. Ressaltamos que esses dados devem ser confirmados por estudos futuros.


Assuntos
Humanos , Adulto , Transtornos da Motilidade Esofágica , Esôfago , Manometria/normas , Peristaltismo , Valores de Referência , Brasil , Pessoa de Meia-Idade
3.
Clinics ; 64(6): 527-533, June 2009. graf, tab
Artigo em Inglês | LILACS | ID: lil-517923

RESUMO

OBJECTIVE: To analyze the results obtained in the evaluation of intra-vaginal pressure using three different brands of perineometers in nulliparous volunteers. MATERIALS AND METHODS: Twenty nulliparous women with no anatomical alterations and/or dysfunction of the pelvic floor were enrolled in our study. All the women had the ability to voluntarily contract their PFM (Pelvic Floor Muscles), as assessed by digital palpation. The intra-vaginal pressure was assessed using three different brands of perineometer (Neurodyn EvolutionTM, SensuPowerTM and PeritronTM). Each volunteer was evaluated on three alternate days by a single examiner using a single brand of perineometer on each day. In the assessment, the volunteers were required to pull (contract) their PFM in and up as strongly as possible 3 times and to sustain the contraction for 5 seconds, with an interval of 30 seconds between each pull. For the statistical analysis, a concordance correlation coefficient was used to compare the values that were obtained with each brand of perineometer. RESULTS: A moderate concordance (0.51) was found between the results from the PeritronTM and NeurodynTM perineometers, a fair concordance (0.21) between the PeritronTM and SensuPowerTM brands and a poor concordance (0.19) between the NeurodynTM and SensuPowerTM brands. CONCLUSION: The concordance of the measurements of the intra-vaginal pressure ranged from poor to moderate, suggesting that perineometers of different brands generate different results.


Assuntos
Adolescente , Adulto , Feminino , Humanos , Gravidez , Adulto Jovem , Contração Muscular , Manometria/instrumentação , Pressão , Diafragma da Pelve/fisiologia , Vagina/fisiologia , Manometria/normas , Paridade , Exame Físico/métodos , Reprodutibilidade dos Testes , Transdutores , Adulto Jovem
4.
Arq. gastroenterol ; 45(4): 261-267, out.-dez. 2008. tab
Artigo em Português | LILACS | ID: lil-502134

RESUMO

RACIONAL: Por padronização aceita internacionalmente, posiciona-se o sensor distal de pHmetria esofágica a 5 cm acima da borda superior do esfíncter inferior do esôfago, localizado por manometria esofágica. Porém, vários autores sugerem técnicas alternativas de posicionamento que prescindem da manometria. Dentre essas, destaca-se a da viragem do pH, tema este controverso pela sua duvidosa confiabilidade. OBJETIVO: Avaliar a adequação do posicionamento do sensor distal de pHmetria pela técnica de viragem do pH, considerando-se a presença, o tipo e o grau de erro de posicionamento que tal técnica proporciona, e também estudar a influência da posição adotada pelo paciente durante a técnica da viragem. MÉTODOS: Foram estudados de modo prospectivo, durante o período de 1 ano, 1.031 pacientes. Durante entrevista clínica, foram registrados os dados demográficos e as queixas clínicas apresentadas. Todos foram submetidos a manometria esofágica para localização do esfíncter inferior do esôfago e a técnica da viragem do pH. A identificação do ponto de viragem foi realizada de dois modos distintos, caracterizando dois grupos de estudo: com o paciente sentado (grupo I - 450 pacientes) e com o paciente em decúbito dorsal horizontal (grupo II - 581 pacientes). Após a identificação do ponto de viragem, o sensor distal de pHmetria era posicionado na posição padronizada, baseada na localização manométrica do esfíncter. Registrava-se onde seria posicionado o sensor de pH se fosse adotada a técnica da viragem. Para avaliação da adequação do posicionamento, considerou-se que o erro é representado pela diferença (em centímetros) entre a localização padronizada (manométrica) e a localização que seria adotada caso fosse empregada a técnica da viragem. Considerou-se que o erro seria grosseiro se fosse maior que 2 cm. Analisou-se também o tipo de erro mais freqüente (se acima ou abaixo da posição padronizada). Foram incluídos todos pacientes que aceitaram participar...


BACKGROUND: By internationally accepted standardization, the esophageal pH-meter distal sensor is positioned 5 cm above the superior border of the lower esophageal sphincter, identified by esophageal manometry. However, several authors suggest alternative positioning techniques that leave out the manometry; among such techniques, the pH step-up is the one to be pointed out. This subject is controversial; some publications state that the step-up technique is not reliable while some others consider it reliable. AIMS: Considering the existent controversy and the small number of prospective works with suitable sample and methodology, we have idealized the present study, that aims the evaluation of the suitability of the pH-meter distal sensor positioning based on the step-up technique, by analyzing the presence, the type and the degree of the error of positioning that such technique provides and the influence of the position adopted by the patient during the procedure. METHODS: One thousand and thirty one patients conducted to the esophageal pH-meter procedure were studied in a prospective way. During the clinical interview, the demographic data and the presented clinical complaints were registered. All the patients were submitted to both esophageal manometry in order to localize the lower esophageal sphincter and the pH step-up technique, that consists of the introduction of the pH-meter sensor in the gastric chamber and in the sensor's gradual traction until the pH steps up to levels over 4. The step-up point was identified by two distinct ways, characterizing two study groups: with the sitting patient (group I - 450 patients) and with the patient in supine position (group II - 581 patients). After the step-up point identification, the pH-meter distal sensor was placed in the standard position (based on the sphincter manometric placement). It was registered where the pH sensor would be positioned if the step-up technique were adopted. To...


Assuntos
Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Erros de Diagnóstico/estatística & dados numéricos , Monitoramento do pH Esofágico/normas , Refluxo Gastroesofágico/diagnóstico , Manometria/métodos , Postura/fisiologia , Eletrodos Implantados , Monitoramento do pH Esofágico/instrumentação , Manometria/normas , Estudos Prospectivos , Estatísticas não Paramétricas , Decúbito Dorsal/fisiologia , Adulto Jovem
5.
Acta cir. bras ; 21(4): 230-236, July-Aug. 2006. ilus, graf
Artigo em Inglês | LILACS | ID: lil-431841

RESUMO

OBJETIVO: Avaliar, em cães, a função da papila duodenal maior submetidas à dilatação por balão hidrostático sob o ponto de vista das alterações radiográficas e manométricas. MÉTODOS: Vinte cães foram submetidos a laparotomia, duodenotomia, dilatação da papila maior - GA(n=10) - com balão de 8mm insuflado com pressão de 0,5atm, durante 2 minutos ou ao procedimento simulado - GB(n=10). A manometria computadorizada e a colangiografia foram efetuadas antes e imediatamente após o procedimento inicial, uma e quatro semanas após a dilatação ou a simulação. Foram calculadas à partir das imagens radiográficas: a média, desvio-padrão, mediana, variação absoluta e porcentual das medidas do diâmetro da papila. Foram medidas: a pressão basal na região da papila, a amplitude das contrações e a pressão do colédoco em todos tempos de observação(t0, t7 e t28). RESULTADOS: Não houve diferença nas medidas do diâmetro da papila em t0 (GA=5,14 e DP=1,1) (GB=4,64 e DP=0,9), assim como nas variações absolutas (0,14mm) ou relativas (-2,7%). Nos animais do GA a medida da pressão basal da papila, mostrou-se menor no t28 (11,1) que nos tempos t0 (18,6) e T7 (16,2). As médias das amplitudes de contração foram significantemente inferiores nos tempos pós-operatórios (pós-t0, t7 e t28) em relação ao tempo inicial (pré-t0), nos animais dos grupos A e B. Os valores médios da pressão no colédoco também foram inferiores em t28 (7,5) que nos tempos t0 (17,8) e t7 (12,6) nos animais do GA.CONCLUSÃO: A função da papila duodenal está comprometida parcialmente com a dilatação, pois provocou diminuição da pressão basal e comprometimento da capacidade do esfíncter em suas contrações cíclicas até aos 28 dias de observação.


Assuntos
Animais , Masculino , Cães , Ampola Hepatopancreática/fisiopatologia , /normas , Colangiografia/normas , Coledocolitíase/terapia , Manometria/normas , Esfincterotomia Transduodenal/normas , Ampola Hepatopancreática , Distribuição de Qui-Quadrado , Modelos Animais de Doenças , Estatísticas não Paramétricas
7.
Maghreb Medical. 1996; (306): 20-21
em Francês | IMEMR | ID: emr-41918
8.
Arq. bras. oftalmol ; 56(5): 291-2, out. 1993.
Artigo em Português | LILACS | ID: lil-134108

RESUMO

A determinaçäo da pressäo intraocular continua a ser um dos elementos propedêuticos básicos em oftalmologia. Os tonômetros de aplanaçäo, segundo a literatura, necessitam de cuidados periódicos relacionados com a sua calibragem. Estudo para verificar a reprodutibilidade dos resultados, ao serem utilizados diferentes tonômetros de aplanaçäo de Goldmann da marca Haag Streit


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Equipamentos e Provisões/normas , Pressão Intraocular , Manometria/normas