1.
Rev. argent. cardiol ; 72(1): 9-13, ene.-feb. 2004. tab
Artigo em Espanhol | LILACS | ID: lil-389394

RESUMO

Este estudio se diseño para evaluar si los manguitos para la medición de la presión arterial pueden ser un reservorio de bacterias con potencial patogenicidad. Material y métodos: En condiciones asépticas, se obtuvo la cobertura de tela de 11 manguitos (seleccionados aleatoriamente) provenientes de consultorios externos o salas de internación de un hospital público. Resultados: El cultivo de los manguitos mostró en todos los casos desarrollo bacteriano, que abarcó 27 aislamientos: 12 Staphylococcus coagulasa negativo (4 de ellos meticilinorresistentes), 6 Staphylococcus aureus (2 meticilinorresistentes), 3 Acinetobacter spp (1 multirresistente), 1 Corynebacterium spp, 1 Streptococcus viridans, 1 Micrococcus spp, y 3 bacilos gramnegativos no fermentadores (diferentes de Pseudomonas aeruginosa y Acinetobacter spp). Conclusiones: Los manguitos de los esfigmomanómetros constituyen un reservorio de bacterias potencialmente patógenas.


Assuntos
Humanos , Infecções Bacterianas , Infecção Hospitalar/etiologia , Monitores de Pressão Arterial/efeitos adversos , Infecções Bacterianas , Contaminação de Equipamentos , Infecção Hospitalar/transmissão , Controle de Infecções , Fatores de Risco
2.
Pakistan Journal of Medical Sciences. 2000; 16 (4): 217-221
em Inglês | IMEMR | ID: emr-115437

RESUMO

To analyze the incidence of infectious complications of invasive blood pressure monitoring. Study was conducted at the Anaesthesia Department of Punjab Institute of Cardiology, Lahore. Design: Arterial catheter tip of 100 adult patient was sent for culture. Both right and left radial arteries were used for cannulation. Outcome Studied: Mean duration of arterial cannulation, any evidence of local or systemic infection, incidence of positive catheter tip culture and types of organism grown were noted. Positive arterial tip culture was seen in 31 patients. Staph epidermidis was the most common organism being seen in 17 patients. Mean duration of cannulation was 34.24 +/- 09.54 hours post operatively. None of these developed any local or systemic evidence of infection. Adherence to the aseptic technique during insertion and maintenance of arterial connulas is very important to prevent the infectious complications related to the procedure. Minimum handling of the whole monitoring system and limiting the duration of cannulation will certainly be helpful in this regard


Assuntos
Humanos , Masculino , Feminino , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Monitores de Pressão Arterial/efeitos adversos , Infecções , Pressão Sanguínea