Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
CoDAS ; 26(2): 112-116, Mar-Apr/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-711124

RESUMO

PURPOSE: Aging causes changes in the external ear as a collapse of the external auditory canal and tympanic membrane senile. Knowing them is appropriate for the diagnosis of hearing loss and selection of hearing aids. For this reason, the study aimed to verify the influence of the anatomical changes of the external ear resonance in the auditory canal in the elderly. METHODS: The sample consisted of objective measures of the external ear of elderly with collapse (group A), senile tympanic membrane (group B) and without changing the external auditory canal or tympanic membrane (group C) and adults without changing the external ear (group D). In the retrospective/clinical study were performed comparisons of measures of individuals with and without alteration of the external ear through the gain and response external ear resonant frequency and the primary peak to the right ear. RESULTS: In groups A, B and C was no statistically significant difference between Real Ear Unaided Response (REUR) and Real Ear Unaided Gain (REUG), but not for the peak frequency. For groups A and B were shown significant differences in REUR and REUG. Between the C and D groups were significant statistics to the REUR and REUG, but not for the frequency of the primary peak. CONCLUSION: Changes influence the external ear resonance, decreasing its amplitude. However, the frequency of the primary peak is not affected .


OBJETIVO: O envelhecimento ocasiona alterações de orelha externa como colabamento do meato acústico externo e membrana timpânica senil. Conhecê-las é oportuno para o diagnóstico da deficiência auditiva e para seleção do aparelho de amplificação sonora individual. Por esse motivo, o estudo propôs-se a verificar a interferência das alterações anatômicas da orelha externa na ressonância do meato acústico em idosos. MÉTODOS: A amostra foi composta por medidas objetivas de orelha externa de idosos com colabamento (grupo A), membrana timpânica senil (grupo B) e sem alteração de meato acústico externo ou membrana timpânica (grupo C) e de adultos sem alteração de orelha externa (grupo D). No estudo retrospectivo/clínico realizaram-se comparações de medidas de indivíduos com e sem alteração de orelha externa por meio do ganho e resposta de ressonância da orelha externa e da frequência de pico primário para orelha direita. RESULTADOS: Nos grupos A, B e C houve diferença estatisticamente significante entre Real Ear Unaided Response (REUR) e Real Ear Unaided Gain (REUG), mas não para a frequência de pico. Para os grupos A e B ocorreu diferença significativa na REUR e REUG. Entre os grupos C e D houve significância estatística para a REUR e REUG, mas não para a frequência do pico primário. CONCLUSÃO: As alterações na orelha externa influenciam na ressonância, diminuindo a sua amplitude. Todavia, a frequência do pico primário não é afetada. .


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Envelhecimento/fisiologia , Orelha Externa/fisiologia , Membrana Timpânica/fisiologia , Testes de Impedância Acústica , Fatores Etários , Auxiliares de Audição , Estudos Retrospectivos
2.
Rev. bras. otorrinolaringol ; 75(1): 15-23, jan.-fev. 2009. graf, tab
Artigo em Inglês, Português | LILACS | ID: lil-514853

RESUMO

Características como a freqüência de ressonância da orelha externa e da orelha média podem interferir na captação das emissões otoacústicas. OBJETIVO: Investigar a influência da freqüência de ressonância da orelha externa e da orelha média na resposta das emissões otoacústicas. DESENHO CIENTÍFICO: Estudo de série, prospectivo, clínico. MATERIAL E MÉTODO: Foram feitas medidas com microfone-sonda na orelha externa, timpanometria de multifreqüência e teste de emissões otoacústicas por transitório e produto de distorção em 19 orelhas direitas e 20 orelhas esquerdas de indivíduos do sexo masculino e 23 orelhas direitas e 23 orelhas esquerdas de indivíduos do sexo feminino com 17 a 30 anos. As 85 orelhas eram audiologicamente normais. RESULTADOS: Não foram observadas relações estatisticamente significantes entre a melhor freqüência de emissões otoacústicas e a freqüência de ressonância da orelha externa oclusa e da orelha média. CONCLUSÃO: Os níveis de respostas das emissões otoacústicas por transitório e produto de distorção não são influenciadas apenas pela ressonância da orelha externa e da orelha média.


Characteristics of how external and middle ear resonance frequency can impact the capture of otoacoustic emissions. AIM: to study the impact of external and middle ear resonance frequency in otoacoustic emissions. STUDY DESIGN: Prospective, clinical, series study. MATERIALS AND METHODS: Microphone-probe measurements were made in the external ear, together with multifrequency timpanometry distortion product transient otoacoustic emissions in 19 right and 20 left ears from male individuals and 23 right and 23 left ears from female individuals with 17 to 30 years of age. The 85 ears were audiologically normal. RESULTS: We did not observe statistically significant associations between the best otoacoustic emission best frequencies and the occluded external and middle ear resonance frequencies. CONCLUSION: Response levels for both transient and distortion product otoacoustic emissions are not influenced by the external and middle ear resonances alone.


Assuntos
Adolescente , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Orelha Externa/fisiologia , Orelha Média/fisiologia , Emissões Otoacústicas Espontâneas/fisiologia , Testes de Impedância Acústica , Análise de Variância , Audiometria de Resposta Evocada , Estudos Prospectivos , Valores de Referência , Adulto Jovem
3.
São Paulo; s.n; 2004. [145] p. ilus, tab, graf.
Tese em Português | LILACS | ID: lil-397834

RESUMO

A pesquisa teve como objetivo investigar o efeito da freqüência de ressonância da orelha externa e da orelha média na captação das emissões otoacústicas por transitório (EOAT) e produto de distorção (EOAPD). Foram analisadas as freqüências de ressonância da orelha externa e média e as EOAT e EOAPD de 85 orelhas audiologicamente normais. Houve uma concentração dos maiores níveis de resposta das EOAT nas freqüências médias e das EOAPD nas freqüências altas, no entanto não foram observadas relações estatisticamente significantes entre as melhores freqüências das emissões e as freqüências de ressonância. /The objective of research was to investigate the effect of the frequency of resonance of external and middle ears in the attainment of the transient and distortion product otoacoustic emissions (TEOAE/DPOAE). The frequency of resonance of external and middle ears and TEOAE and DPOAE emissions were analyzed in 85 ears with normal hearing. There was a concentration of the highest levels of TOAE in middle frequencies and of DPOAE in high frequencies however there were not statistically significant relations between the best frequencies of otoacoustic emissions and frequencies of resonance...


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Orelha Interna/fisiologia , Orelha Externa/fisiologia , Orelha Média/fisiologia , Testes de Impedância Acústica , Amplificadores Eletrônicos , Emissões Otoacústicas Espontâneas
4.
An. otorrinolaringol. mex ; 40(3): 117-21, jun.-ago. 1995. ilus, tab
Artigo em Inglês | LILACS | ID: lil-174000

RESUMO

Se hace una breve descripción de la anatomía del oído externo y de la fisiología auditiva de Sceloporus torcuatus. Se señala que la depresión formada por el conducto auditivo externo esta parcialmente cubierta por escamas de mayor tamaño que las normales, las que además tienen forma diferente al resto de las escamas de la región, por lo que se les dio un nombre especial, denominándolas escamas frontales del oído externo. Se describe detalladamente el conducto coclear, poniendo énfasis en la histología del mismo. También se describen algunos epitelios, tales como los de la papila basilar (órgano de la audición), las manchas de la lagena y la pared vestibular del conducto coclear, esta última se ha considerado en otros reptiles como tejido secreto. La similitud morfológica entre la pared vestibular del conducto coclear de esta especie, la estría vascular de los mamíferos y el tegumento vasculoso de las aves, sugiere semejanzas funcionales de estas estructuras. Se usaron potenciales evocados auditivos del tallo cerebral para estudiar esta especie reptiliana. Se encontró (con clics) el umbral de potenciales de estímulos auditivos a 40 dB


Assuntos
Animais , Ducto Coclear/anatomia & histologia , Meato Acústico Externo/anatomia & histologia , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Orelha Externa/fisiologia , Répteis/fisiologia
5.
Pró-fono ; 6(2): 14-7, set. 1994. tab
Artigo em Português | LILACS | ID: lil-227955

RESUMO

O presente trabalho teve como objetivo medir a variabilidade das medidas dos efeitos de ressonância da orelha externa, em 41 orelhas, através do teste-reteste de "curto prazo", nas condiçöes clínicas do Setor de Audiologia da Escola Paulista de Medicina. As medidas foram obtidas em sala näo tratada acusticamente, com equipamento Real Ear Measuring System CCI-10/3, marca Rastronics, realizando-se em teste e dois retestes. Foram selecionadas para estudo as frequências de 250, 5000, 1000, 2000, 3000, 4000, 6000 e 8000 Hz. Os resultados obtidos mostraram que 95 (por cento) dos valores encontrados no teste e retestes foram menores do que 3 dB para as frequências de 250, 1000, 2000, 3000 e 6000 Hz, e foram menores do que 5 dB para as frequências de 500, 4000 e 8000 Hz


Assuntos
Humanos , Masculino , Feminino , Adulto , Testes de Impedância Acústica , Estimulação Acústica , Orelha Externa/fisiologia , Implantes Cocleares
6.
Acta AWHO ; 13(2): 63-7, maio-ago. 1994. tab, graf
Artigo em Português | LILACS | ID: lil-139504

RESUMO

O objetivo da presente pesquisa foi estudar a influência do ângulo de incidência da onda sonora sobre o ganho acústico, resultante dos efeitos de ressonância da orelha externa, segundo as variáveis sexo e lado da orelha. A onda sonora foi emitida em campo livre, sob três diferentes ângulos de incidência - 0º, 45º e 90º azimute e as freqüências estudadas foram 2000, 2500, 3000, 3500, 4000, 5000, 6000 Hz. As medidas foram obtidas no nível da membrana timpânica de 42 indivíduos adultos normais (84 orelhas) de ambos os sexos. O sistema computadorizado da Rastronics Real Ear Measuring System CCI-10/3, possibilitou as mensuraçöes in situ. O estudo do ganho acústico nos três diferentes ângulos de incidência da onda sonora, revelou que os valores obtidos a 0º azimute foram menores do que os obtidos a 45º e 90º azimute em todas as freqüências estudadas e nos picos de ressonância. Por sua vez, os valores obtidos a 45º azimute foram menores do que a 90º azimute em 2500 Hz e nos picos de ressonância, tendo sido maiores nas demais freqüências. A análise estatística dos resultados segundo as variáveis sexo, lado da orelha e ângulo de incidência da onda sonora, mostrou-se significante


Assuntos
Humanos , Masculino , Feminino , Adulto , Audição/fisiologia , Orelha Externa/fisiologia , Estimulação Acústica/métodos , Valores de Referência
7.
Acta AWHO ; 9(3): 110, 115-20, set.-dez. 1990. tab
Artigo em Português | LILACS | ID: lil-92974

RESUMO

Através de um equipamento assistido por microprocessador de sinais associado a um microfone-sonda miniaturizado, do tipo Rastronics CCI 10/3, pôde-se pesquisar a existência do fenômeno de ressonância da orelha externa em indivíduos normais, numa faixa de freqüência entre 2.000 e 4.000Hz, com pico em 3.000Hz. O equipamento apresenta uma importância substancial na aplicaçäo clínica de acompanhamento dos deficientes auditivos, sendo um instrumento objetivo na indicaçäo, seleçäo e adaptaçäo da prótese auditiva e de grande utilidade no aperfeiçoamento dos moldes de orelha, além de contribuir para uma melhor compreensäo dos problemas ocasionados pelo trauma acústico


Assuntos
Humanos , Adulto , Feminino , Orelha Externa/fisiologia , Membrana Timpânica/fisiologia , Estimulação Acústica , Limiar Auditivo , Próteses e Implantes , Tempo de Reação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA