1.
Rev. bras. enferm ; 72(supl.3): 162-169, 2019. tab
Artigo em Inglês | BDENF, LILACS | ID: biblio-1057717

RESUMO

ABSTRACT Objective: to compare blood pressure values obtained by auscultatory and oscillometric methods in different gestational periods, considering cuff width. Method: it is a cross-sectional and quasi-experimental study approved by the Research Ethics Committee. The sample consisted of 108 low-risk pregnant women. Blood pressure measurements were performed in gestational periods of 10-14, 19-22 and 27-30 weeks. Results: The oscillometric device presented values similar to the auscultatory method in systolic blood pressure, but overestimated diastolic blood pressure. Underestimation of blood pressure occurred when using the standard width cuff rather than the correct width cuff in both measuring methods. Conclusion: Verification of brachial circumference and use of adequate cuffs in both methods are indispensable to obtain reliable blood pressure values in pregnant women. We recommend performance of additional studies to evaluate diastolic blood pressure overestimation by the Microlife 3BTO-A.


RESUMEN Objetivo: Comparar los valores de presión arterial obtenidos por los métodos auscultatorio e oscilométrico en distintos períodos del embarazo, en función del ancho del manguito. Método: Se trata de un estudio transversal y cuasiexperimental aprobado por el Comité de Ética en Investigación. Se analizó una muestra compuesta por 108 embarazadas de bajo riesgo. Las medidas de presión arterial se obtuvieron en los períodos gestacionales de 10-14, 19-22 y 27-30 semanas. Resultados: El aparato oscilométrico presentó valores similares al método auscultatorio en la presión arterial sistólica, sin embargo sobreestimó la presión arterial diastólica. Hubo subestimación de la presión arterial al utilizar el manguito de anchura estándar en lugar del manguito de anchura adecuada, en los dos métodos de medida. Conclusión: La verificación de la circunferencia braquial y el uso de manguitos adecuados en los dos métodos son indispensables para obtener valores confiables de la presión arterial en embarazadas. Recomendamos que se realicen nuevos estudios para evaluar la sobreestimación de la presión arterial diastólica por el aparato Microlife 3BTO-A.


RESUMO Objetivo: Comparar os valores de pressão arterial, obtidos pelos métodos auscultatório e oscilométrico em diferentes períodos gestacionais, em função da largura do manguito. Método: Trata-se de um estudo transversal e quase-experimental aprovado pelo Comitê de Ética em Pesquisa. A amostra foi composta por 108 gestantes de baixo risco. As medidas de pressão arterial foram realizadas nos períodos gestacionais de 10-14, 19-22 e 27-30 semanas. Resultados: O aparelho oscilométrico apresentou valores similares ao método auscultatório na pressão arterial sistólica, porém superestimou a pressão arterial diastólica. Houve subestimação da pressão arterial ao utilizar o manguito de largura padrão ao invés do manguito de largura correta, nos dois métodos. Conclusão: A verificação da circunferência braquial e o uso de manguitos adequados nos dois métodos são indispensáveis para obter valores confiáveis da pressão arterial em gestantes. Recomendamos que novos estudos sejam realizados para avaliar a superestimação da pressão arterial diastólica pelo aparelho Microlife 3BTO-A.


Assuntos
Humanos , Feminino , Gravidez , Adulto , Oscilometria/instrumentação , Determinação da Pressão Arterial/instrumentação , Gestantes , Oscilometria/métodos , Oscilometria/normas , Auscultação/instrumentação , Auscultação/métodos , Determinação da Pressão Arterial/métodos , Determinação da Pressão Arterial/normas , Estudos Transversais , Idade Gestacional , Pessoa de Meia-Idade
2.
Acta fisiátrica ; 22(4): 186-191, dez. 2015.
Artigo em Inglês, Português | LILACS | ID: biblio-970

RESUMO

Oscilometria de impulso (IOS) é um método alternativo e complementar de avaliação da mecânica respiratória, mas cuja técnica de execução ainda necessita padronização. Objetivo: Analisar e comparar os resultados de parâmetros do IOS quando realizado em escolares nas posições ortostática e sentada. Método: estudo analítico observacional transversal. Escolares saudáveis de 6 a 12 anos foram submetidos à espirometria e dois exames de IOS randomizados quanto à postura (sentada e ortostática). Os dados foram analisados no SPSS 20.0. Utilizou-se o teste Shapiro-Wilk e, segundo a normalidade dos dados, aplicou-se o teste de Wilcoxon ou t de Student para comparação das posturas. Na correlação entre dados antropométricos e as variáveis oscilométricas empregouse o teste de Pearson ou Spearman, com p ≤ 0,05. Resultados: participaram 72 crianças, idade média de 8,42 ± 1,26. Não houve diferença entre as variáveis oscilométricas nas duas posturas. Na posição sentada, houve correlação negativa baixa entre altura de tronco (Altronco) e variáveis: resistência a 20Hz (R20) (p = 0,034) e a 5Hz (R5) (p = 0,041), resistência central (Rescent) (p = 0,018) e impedância (Z) (p = 0,030). Em ortostatismo verificou-se correlação negativa baixa entre idade e resistência periférica (Resper) (p = 0,011), R5 (p = 0,014) e Z (p = 0,009). Conclusão: Não houve diferença nos valores das variáveis oscilométricas entre a postura sentada e ortostática. Contudo, a resistência das vias aéreas foi influenciada pela Altronco, estatura e idade. O ortostatismo parece ser a melhor posição para análise da Resper


Impulse oscillometry (IOS) is an alternative and supplementary method for evaluating respiratory mechanics, but whose performance technique still requires standardization. Objective: This study sought to analyze and compare the results of IOS parameters when done with schoolchildren in standing (orthostatic) and sitting positions. Method: Analytical cross-sectional study. Healthy school children of 6 to 12 years were submitted to spirometry and two exams with IOS (randomized sitting and standing). Data were analyzed with SPSS 20.0. Using the Shapiro-Wilk test and, according to the normality of the data, applying the Wilcoxon or Student T-tests, the postures were compared. In correlating between the anthropometric data and the oscillometric variables, the Pearson or Spearman test was used, with p ≤ 0.05. Results: Participating were 72 children with a mean age of 8.42 ± 1.26. There was no difference between the oscillometric variables in the two postures. In the sitting position, there was low negative correlation between trunk height (Hetrunk) and the following variables: resistance to 20Hz (R20) (p = 0.034) and 5Hz (R5) (p = 0.041), central resistance (Rescent) (p = 0.018), and impedance (Z) (p = 0.030). In the standing position there was low negative correlation between age and peripheral resistance (Resper) (p = 0.011), R5 (p = 0.014), and Z (p = 0.009). Conclusion: There was no difference noted in comparing the oscillometric variables in the two postures. However, the airway resistance was influenced by Hetrunk, height, and age. The orthostatic position seems to be the best position to analyze Resper


Assuntos
Humanos , Criança , Oscilometria/instrumentação , Postura , Testes de Função Respiratória/instrumentação , Mecânica Respiratória , Estudos Transversais , Estudo Observacional
3.
J. bras. nefrol ; 34(1): 43-49, jan.-fev.-mar. 2012. graf, tab
Artigo em Português | LILACS | ID: lil-623354

RESUMO

INTRODUÇÃO: Um dos maiores desafios no manejo da hipertensão arterial é o adequado controle pressórico. Para se alcançar esse objetivo tem se difundido a medida residencial da pressão arterial (MRPA) com aparelhos automáticos. Entretanto, parte da comunidade médico-científica ainda discute sua validade, acreditando que as medidas pressóricas domiciliares podem ser incorretas. OBJETIVO: Avaliar a correspondência entre as medidas simultâneas da pressão arterial (PA) pelo método auscultatório convencional e método digital automático, habitualmente utilizado na MRPA. MÉTODOS: Através de uma conexão em "Y" acoplamos um manguito a um aparelho digital automático validado (ONROM 705IT) e a um esfigmomanômetro de coluna de mercúrio, permitindo aferir simultaneamente a PA pelos dois métodos. Determinamos a PA em 423 indivíduos (normotensos e hipertensos), adequando o tamanho do manguito à circunferência braquial. RESULTADOS: Os valores representam média ± desvio padrão (DP) (valores mínimo-máximo): Idade 40,8 ± 16,3 anos (18-92), circunferência braquial 28,2 ± 3,7 cm (19-42), PA sistólica (PAS) auscultatório 127,6 ± 22,8 mmHg (69-223), PAS automático 129,5 ± 23,0 mmHg (56-226), PA diastólica (PAD) auscultatório 79,5 ± 12,6 mmHg (49-135), PAD automático 79,0 ± 12,6 mmHg (48-123). A diferença média da PAS entre os dois métodos foi de 1,9 mmHg (-15 a +19) e a diferença da PAD de 0,5 mmHg (-19 a +13). Os índices de correlação de Pearson entre os métodos são para a PAS (r = 0,97), e PAD (r = 0,91). A análise de Bland-Altman mostrou concordância clinicamente aceitável entre os métodos. CONCLUSÃO: A PA aferida pelo método digital automático apresenta boa concordância com o método auscultatório convencional, devendo ser usada no auxílio do diagnóstico e controle da hipertensão arterial (HA).


INTRODUCTION: One of the biggest challenges in the management of hypertension is adequate blood pressure (BP) control. To achieve this goal, home blood pressure measurement (HBPM) with automated devices has been encouraged. However, part of the medical community still disputes its validity, believing that HBPM may lead to incorrect readings. OBJECTIVE: To evaluate the correspondence between the simultaneous measurements of BP with the auscultatory method and an oscillometric digital method, commonly used in HBPM. METHODS: BP was determined simultaneously in 423 individuals (normotensive and hypertensive) with a validated automated digital device (ONROM 705IT) and with the auscultatory method with a mercury sphygmomanometer. Both devices were connected through a Y-shaped connection to a cuff whose size was adjusted to the arm circumference. RESULTS: The values represent mean ± SD (minimum-maximum values): age 40.8 ± 16.3 years (18-92), arm circumference 28.2 ± 3.7 cm (19-42), systolic BP (SBP) auscultatory 127.6 ± 22.8 mmHg (69-223), SBP automated 129.5 ± 23.0 mmHg (56-226), diastolic BP (DBP) auscultatory 79.5 ± 12.6 mmHg (49-135) DBP automated 79.0 ± 12.6 mmHg (48-123). The mean difference in SBP between the two methods was 1.9 mmHg (-15 to +19) and 0.5 mmHg for DBP (-19 to +13). The Bland-Altman analysis showed clinically acceptable agreement between the methods. CONCLUSION: BP measured with the automated method closely mirrors that determined with the conventional auscultatory method and should be used to improve the diagnosis and control of hypertension.


Assuntos
Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Determinação da Pressão Arterial/métodos , Pressão Sanguínea/fisiologia , Oscilometria/instrumentação , Esfigmomanômetros
4.
Arq. bras. cardiol ; 90(5): 322-326, maio 2008. tab
Artigo em Inglês, Português | LILACS | ID: lil-482922

RESUMO

FUNDAMENTO: Índice Tornozelo-Braquial (ITB) é essencial na prática clínica, mas dificuldades técnicas na sua execução pelo padrão de referência Doppler vascular (DV) tornam-no ainda pouco utilizado. OBJETIVO: Avaliar aplicabilidade da determinação do ITB com uso de esfigmomanômetros oscilométricos automáticos (EOA) e sugerir a utilização dos índices delta-Bráquio-Braquial (delta-BB) e delta-ITB como marcadores de risco cardiovascular. MÉTODOS: Estudo descritivo e observacional de 247 pacientes ambulatoriais (56,2 por cento feminino, média 62,0 anos) submetidos à determinação do ITB com aferição simultânea da pressão arterial (PA) em membros superiores (MMSS) e inferiores (MMII) utilizando-se dois EOA (OMRON-HEM705CP). Nos casos em que não foi possível aferir PA em pelo menos um dos MMII utilizou-se DV. Os pacientes divididos em Grupo N (ITB normal: 0,91 a 1,30) e Grupo A (ITB alterado: <0,90 ou >1,30) tiveram comparados entre si os valores de delta-ITB (diferença absoluta ITB/MMII) e delta-BB (diferença absoluta PAS/MMSS). RESULTADOS: Utilizando-se EOA foi possível determinar ITB em 90,7 por cento. Com dados do Grupo N determinaram-se valores de referência (VR) no percentil 95 de delta-ITB (0-0,13) e delta-BB (0-8 mmHg). Quando comparado com o Grupo N, o Grupo A apresentou prevalência mais elevada tanto de delta-ITB (30/52 contra 10/195; Razão de Chances: 25,23; p<0,0001) como de delta-BB (13/52 contra 7/195; Razão de Chances: 8,95; p<0,0001) acima dos VR. CONCLUSÃO: O ITB pode ser determinado na maioria das vezes com EOA. Delta-ITB e delta-BB acima dos VR estiveram significativamente mais prevalentes nos portadores de ITB alterado e podem ser sugeridos como marcadores de risco cardiovascular em futuros estudos epidemiológicos.


BACKGROUND: Assessing Ankle-Brachial Index is an essential procedure in clinical settings, but since its measurement by the gold standard Doppler Ultrasonic (DU) technique is impaired by technical difficulties, it is underperformed. OBJECTIVE: The aim of this study was to assess the efficacy of an automated oscillometric device (AOD) by performing Ankle-Brachial Index (ABI) assessments and to suggest delta brachial-brachial (delta-BB) and delta-ABI as markers of cardiovascular risk. METHODS: In this observational and descriptive study, 247 patients (56.2 percent females, mean age 62.0 years) had their arterial blood pressure (ABP) measured for ABI calculation. Two AOD (OMRON-HEM705CP) devices were used for simultaneous measurements of the ABP, first of the two arms and then of the arm with higher systolic ABP and a leg, first the left and then the right one. When leg ABP measurements were not possible, ABI determination was performed by using the standard Doppler Ultrasonic (DU) technique. Patients were designated to Group N (normal ABI: 0.91 to 1.30) or Group A (abnormal ABI: <0.90 or >1.30). Other indexes were also calculated: delta-BB (absolute difference in mmHg of systolic ABP between arms) and delta-ABI (absolute difference of ABI between legs) and the results were compared. RESULTS: In most patients (90.7 percent), it was possible to determine the ABI. Group N data allowed calculation of the 95th percentile reference values (RV) of delta-BB (0 to 8 mmHg) and delta-ABI (0 to 0.13). When compared to Group N, Group A had a significantly higher prevalence of high values greater than the RVs of delta-ABI (30 of 52 and 10 of 195, respectively; Odds Ratio = 25.23; p<0.0001) and delta-BB (13 of 52 and 7 of 195, respectively; Odds Ratio = 8.95; p<0.0001). CONCLUSION: In most patients, the ABI could be measured by AOD. Both indexes, delta-BB and delta-ABI greater than the RVs, were significantly more prevalent in patients with abnormal ABI ...


Assuntos
Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tornozelo/irrigação sanguínea , Braço/irrigação sanguínea , Pressão Sanguínea/fisiologia , Artéria Braquial/fisiologia , Oscilometria/métodos , Doenças Vasculares Periféricas/diagnóstico , Análise de Variância , Tornozelo/fisiologia , Braço/fisiologia , Determinação da Pressão Arterial/métodos , Intervalos de Confiança , Razão de Chances , Oscilometria/instrumentação , Valor Preditivo dos Testes , Doenças Vasculares Periféricas/fisiopatologia , Fluxo Sanguíneo Regional
5.
J. pediatr. (Rio J.) ; 75(2): 91-6, mar.-abr. 1999. ilus, tab
Artigo em Português | LILACS | ID: lil-234283

RESUMO

objetivo: Este estudo propöem-se a analisar a substituiçäo do método oscilométrico para determinar a pressäo arterial, independente da validade do método auscultatório quando relacionado ao método intra-arterial. O objetivo específico foi o de avaliar a acurácia do método oscilométrico na determinaçäo da pressäo arterial quando comparado com o método auscultarório utilizando o esfigmomanômetro de coluna de mercúrio, tomado como referência, em escolares aparentemente normais. Método: Para determinaçäo da pressäo arterial, utilizou-se um equipamento capaz de produzir 3 leituras simultâneas: a do monitor e dos dois observadosre "cegos". Foram estudados 72 escolares com média de idade de 9,5 anos (mínimo de 6,1 e máximo de 16,1 anos), do sexo masculino 39 (54,2 por cento). Resultados: A diferença entre a pressäo sistólica obtida pelo monitor em relaçäo oas observadores foi em média de + 6,2 mm de Hg, e a diferença entre as pressöes diastólicas obtidas pelo monitor em relaçäo aos observadores versus monitor, e o nível de comparabilidade foi pobre. Conclusöes: Sob as condiçöes da pesquisa (método e populaçäo) näo podemos indicar a substituiçäo do método auscultatório clássico pelo método oscilométrico do monitor digital näo invasivo para determinar a pressäo arterial em escolares


Assuntos
Humanos , Masculino , Feminino , Criança , Adolescente , Determinação da Pressão Arterial , Oscilometria/instrumentação , Equipamentos e Provisões , Esfigmomanômetros