1.
Arq. bras. med. vet. zootec. (Online) ; 73(3): 647-652, May-June 2021. ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1278370

RESUMO

The treatment of fractures from the thoracic limb in giant anteaters is extremely challenging. Unfamiliar and peculiar anatomical characteristics, robust musculature and the imminent need for an early return to limb function highlight such challenges. The objective of this report was to describe the successful use of anatomical osteosynthesis with a robust locking compression plate in a humeral fracture of an adult giant anteater. The patient was rescued on the highway after being run over and presented for treatment at the Veterinary Teaching Hospital. Surgical stabilization was performed using a craniomedial approach to the humerus, using a customized broad 3.5mm locking compression plate. The patient presented early limb support at 24 hours postoperatively. Radiographic monitoring was performed at 30, 60 and 90 days postoperatively, and bone healing was observed without any complications. It is concluded that the treatment of humerus fractures in giant anteaters requires robust fixation. The use of a reinforced locking compression plate system proved to be effective and adequate to the mechanical load that an adult individual of this species needs for early use of the thoracic limb and, at the same time, efficient in controlling interfragmentary movement, which allowed fracture consolidation.(AU)


O tratamento das fraturas do membro torácico dos tamanduás-bandeira (Myrmecophaga tridactyla) é extremamente desafiador. Características anatômicas pouco familiares e peculiares, musculatura muito desenvolvida e necessidade iminente de retorno precoce à função do membro destacam tais desafios. Objetivou-se, neste relato, descrever a utilização com sucesso da osteossíntese anatômica com placa bloqueada robusta em fratura umeral de um tamanduá-bandeira. O paciente foi resgatado em rodovia após atropelamento e atendido no Hospital Veterinário Universitário. Após sedação e avaliação física completa, foi realizado exame radiográfico, o qual revelou fratura completa oblíqua curta em diáfise média de úmero esquerdo. A estabilização cirúrgica foi realizada por abordagem craniomedial ao úmero, utilizando-se placa bloqueada (LCP) do sistema 3,5mm customizada. O paciente apresentou apoio precoce do membro com 24 horas de pós-operatório. Realizou-se acompanhamento radiográfico aos 30, 60 e 90 dias, sendo observada união clínica sem quaisquer complicações. Conclui-se que o tratamento das fraturas do úmero em tamanduás-bandeira exige robustez na fixação. A utilização de sistema reforçado de placa bloqueada mostrou-se efetiva e adequada à carga mecânica de que um indivíduo adulto dessa espécie necessita para uso precoce do membro torácico e, ao mesmo tempo, eficiente no controle da movimentação interfragmentária, o qual permitiu consolidação da fratura.(AU)


Assuntos
Animais , Consolidação da Fratura , Eutérios/cirurgia , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/veterinária , Fraturas do Úmero/cirurgia , Fraturas do Úmero/veterinária , Placas Ósseas/veterinária , Animais Selvagens/cirurgia
2.
Arq. bras. med. vet. zootec. (Online) ; 72(2): 493-498, Mar./Apr. 2020. ilus
Artigo em Português | LILACS, VETINDEX | ID: biblio-1128385

RESUMO

Foi atendida, no Hospital Veterinário da Universidade de Cuiabá, uma coruja suindara (Tyto furcata), resgatada pela Polícia Militar Ambiental, sem histórico, adulta e 400 gramas de peso corporal. A ave apresentava impotência funcional do membro pélvico direito, além de desvio, crepitação e dor na região proximal tibiotársica direita, sem lesão cutânea. Estudo radiográfico revelou fratura diafisária oblíqua curta em tibiotarso direito. A estabilização da fratura foi realizada com placa bloqueada do sistema de 1,5mm, na função de apoio, seis orifícios, com três parafusos monocorticais distais, dois parafusos monocorticais proximais e um parafuso bicortical proximal. Ao 30º dia do pós-operatório, os achados radiográficos de consolidação óssea e o retorno da função do membro permitiram a alta médica. Concluiu-se que o uso de placa bloqueada em função apoio para estabilização de fraturas tibiotársicas simples de coruja suindara oferece resultados satisfatórios.(AU)


An adult suindara owl (Tyto furcata), with no specific history and 400 grams of body weight was treated at the Veterinary Hospital of the University of Cuiabá. The patient presented functional impotence in the right pelvic limb, deviation, crepitation and pain in the proximal region in right tibiotarsal, without cutaneous lesions. Radiographs revealed a short oblique diaphyseal fracture at the right tibiotarsus. Fracture stabilization was performed with a 1.5mm locking plate, buttress, six holes; three distal monocortical screws, two proximal monocortical screws and a proximal bicortical screw. On the 30th postoperative day, radiographic revealed bone healing, and the return of limb function allowed medical discharge. It was concluded that the use of locking plates in buttress function to stabilize simple tibiotarsus fractures in suindara owl offers satisfactory results.(AU)


Assuntos
Animais , Fraturas da Tíbia/cirurgia , Placas Ósseas/veterinária , Estrigiformes/cirurgia , Fraturas Ósseas/veterinária , Fixação Interna de Fraturas/veterinária
3.
Arq. bras. med. vet. zootec. (Online) ; 71(4): 1339-1347, jul.-ago. 2019. tab, graf, ilus
Artigo em Português | VETINDEX, LILACS | ID: biblio-1038623

RESUMO

O presente estudo objetivou comparar, biomecanicamente, por meio do ensaio de compressão excêntrica, a resistência dos implantes Clamp and Rod Internal Fixation (CRIF) 5,0mm e placa de reconstrução 3,5mm na fixação de fraturas distais de fêmur de cão. Foram utilizados 22 fêmures de 11 cadáveres de cão entre 2 e 7 anos de idade e peso corporal entre 20 e 40kg e subdivididos em dois grupos, denominados grupo CRIF (GC - 11 fêmures) e grupo placa (GP - 11 fêmures). Para realização dos testes, foi simulada falha que mimetizasse uma fratura distal nos corpos de prova, por meio de uma osteotomia de até 0,5cm, realizada com auxílio de serra oscilatória, imediatamente proximal ao início da tróclea. Os implantes foram fixados segundo os padrões AOSIF, lateralmente ao fêmur, sendo utilizados três parafusos distais e cinco proximais ao foco de fratura. Foi empregado o programa de computador PMI para calcular o ponto máximo de resistência antes da falha e avaliaram-se as variáveis força máxima, deformação máxima real, rigidez, força intermediária e deformação intermediária real. Não foram encontradas diferenças estatisticamente significativas entre os GC e GP quanto às variáveis avaliadas, sugerindo que ambos os implantes são boas opções de fixações para tais fraturas.(AU)


This study aims to compare the biomechanical properties, through compression eccentric test, of the resistance of the 5.0mm Clamp and Rod Internal Fixation Implants (CRIF) and 3.5mm reconstruction plate in fixing dog femur distal fracture. It was used 22 femurs from 11 dog cadavers with age between 2 and 7 years old and body weight between 20 and 40kg, subdivided into two groups, called CRIF Group (CG - 11 femurs) and plate group (PG - 11 femurs). A distal fracture in the specimens with a gap of 0.5cm osteotomy, was simulated to perform the test, performed by the oscillating saw, just proximal to the beginning of the trochlea. The implants were fixed by the standards AO / SIF, laterally to the femur, using three distal screws and five proximal to the fracture site. PMI computer program was used to calculate the maximum point of resistance before failure and evaluated the variables maximum strength, real maximum deformation, stiffness, intermediate strength and real intermediate deformation. No statistically significant differences were found between the GC and GP as the variables evaluated, suggesting that both implants are good fixation options for such fractures.(AU)


Assuntos
Animais , Cães , Placas Ósseas/veterinária , Fixadores Internos/veterinária , Fraturas do Fêmur/veterinária , Fixação de Fratura/métodos , Fixação de Fratura/veterinária
4.
Pesqui. vet. bras ; 38(2): 335-339, fev. 2018. ilus
Artigo em Português | LILACS, VETINDEX | ID: biblio-895567

RESUMO

Foi atendido um Gavião Caboclo (Buteogallus meridionalis), de vida livre e histórico desconhecido. O paciente apresentava impotência funcional da asa direita e solução de continuidade de aspecto recente envolvendo a região de rádio e ulna direitos caracterizando fratura aberta grau II. Os achados radiológicos foram fratura completa cominutiva de diáfise média de ulna e fratura completa tranversa de diáfise média de rádio. A estabilização da fratura de rádio foi realizada com miniplaca de 1,5mm de 6 orifícios, com 2 parafusos proximais e 2 parafusos distais e, osteossíntese de ulna com placa bloqueada de 2,0mm de 12 orifícios, com 3 parafusos proximais e 2 parafusos distais. Aos 180 dias de pós-operatório, os implantes ortopédicos foram removidos e o paciente recebeu alta. Conclui-se que o emprego de placa bloqueada para tratamento de fraturas abertas em ulna de Gavião Caboclo, pode propiciar adequada consolidação e retorno à função do membro sendo capaz de voar.(AU)


A wild Savanna Hawk (Buteogallus meridionalis) of unknown history, was seen at the veterinary hospital. The patient presented with a dropped right wing and soft tissue damage that appeared to be a recent wound involving the right radius and ulna region, characterizing an open fracture grade II. The radiological findings were a comminuted complete fracture of the ulnar diaphysis and complete transverse fracture of the radial diaphysis. Stabilization of the radius fracture was performed with a 1.5mm miniplate with 6 holes, with 2 proximal screws and 2 distal screws, and ulna osteosynthesis with a 2.0mm locking plate with 12 holes, with 3 proximal screws and 2 distal screws. At 180 postoperative days, the implants were removed and the patient was discharged. The use of locking plate for the treatment of open fractures in ulna of Savanna Hawks may provide adequate healing and return to limb function being able to fly.(AU)


Assuntos
Animais , Placas Ósseas/veterinária , Fixação Interna de Fraturas/veterinária , Falcões/cirurgia , Fraturas do Rádio/cirurgia , Fraturas da Ulna/cirurgia , Rádio (Anatomia)/cirurgia , Ulna/cirurgia
5.
Pesqui. vet. bras ; 37(12): 1474-1478, dez. 2017. ilus
Artigo em Português | LILACS, VETINDEX | ID: biblio-895384

RESUMO

Tendo em vista as vantagens das hastes intramedulares bloqueadas (HIB) em relação às placas ósseas na estabilização femoral, o presente estudo objetivou avaliar a exequibilidade e eficácia da aplicação da HIB pós osteotomia intertrocantérica varizante (OIV). Submeteu-se 10 cadáveres caninos à OIV. Nos antímeros esquerdos obteve-se a estabilização por meio de HIB (grupo HIB) e, nos direitos, com placas de compressão dinâmica (grupo placa). Foram comparados os ângulos de Norberg e de inclinação da cabeça e colo femoral (ICF) antes (T0) e após (T1) a OIV. O tempo dispendido para a colocação dos implantes e resultados de resistência biomecânica à compressão e torção também foram confrontados entre os grupos. Houve aumento do ângulo de Norberg entre T0 (106,84®5,55o) e T1 (111,22o®3,89), apenas no grupo HIB (p<0,05). No entanto, redução do ângulo de ICF após OIV (T1) foi observada tanto no grupo placa (T0=127,6®4,70o e T1=110,06®10,61o, p<0,05) quanto no grupo HIB (T0=126,43®5,87o e T1=116,87®8,62o, p<0,05). Os tempos de colocação dos implantes não diferiram estatisticamente e apenas o teste biomecânico de compressão revelou diferença entre os grupos, com maior resistência (P=0,033) do grupo placa (863,3®74,46N/mm) em relação ao grupo HIB (586,7®44,10N/mm). Deste modo, a estabilização por meio de HIB foi factível e eficaz. Embora o resultado biomecânico de compressão tenha demonstrado maior fragilidade da HIB em relação à placa de compressão, seus valores estão acima das forças atuantes, reportadas na literatura, na deambulação normal de cão.(AU)


Considering the advantages of the interlocking intramedullary nail (IN) in relation to bone plates in the femoral stabilization, this study aimed to evaluate the feasibility and effectiveness of IN application post intertrochanteric varus osteotomy (IVO). For this purpose, 10 canines cadavers were used. On the left femurs, the fixation was obtained with IN (IN group) and rights fixed with dynamic compression plates and screws (plate group). Was compared the angles of Norberg and inclination of the head and femoral neck (IHF) before (T0) and after (T1) IVO. The results of time spent for placement of implants and biomechanical resistance to compression and torsion were also confronted between groups. There was an increase of the Norberg angle between T0 (106.84®5.55o) and T1 (111.22o®3.89), only in IN group (p<0.05). However, reduction of IHF angle after IVO (T1) was observed in both, the plate group (T0=127.6®4.70o e T1=110.06®10.61o, p<0.05) and IN group (T0=126.43®5.87o e T1=116.87® 8.62 o, p<0.05). The placement times of the implants did not differ statistically and only the compression biomechanical test revealed differences between groups, with greater resistance (P=0.033) of the plate group (863.3®74.46N/mm) compared to IN group (586.7®44.10N/mm). Thus, stabilization through IN was feasible and effective. Although the compression biomechanical results has demonstrated a higher fragility of IN in relation to the compression plate, their values are above the forces, reported in literature, acting in normal dog gait.(AU)


Assuntos
Animais , Cães , Osteotomia/veterinária , Próteses e Implantes/veterinária , Placas Ósseas/veterinária , Fixação Intramedular de Fraturas/veterinária , Displasia Pélvica Canina/terapia , Fraturas do Quadril/veterinária , Procedimentos Ortopédicos/veterinária
6.
Arq. bras. med. vet. zootec ; 66(5): 1343-1350, Sep-Oct/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-729768

RESUMO

The present study aimed to assess the heat generated by a therapeutic ultrasound (TUS) in a metal bone plate and adjacent structures after fixation to the femur of canine cadavers. Ten pairs of hind limbs were used, and they were equally distributed between groups that were subjected to 1- and 3-MHz frequencies, with each frequency testing 1- and 2-W/cm² intensities. The right hind limb was defined as the control group (absence of the metal plate), and the left hind limb was the test group (presence of the metal plate). Therefore, the control groups (CG) were denominated CGI, using TUS with 1-MHz frequency and 1-W/cm² intensity; CGII, using 1-MHz frequency and 2-W/cm² intensity; CGIII, using 3-MHz frequency and 1-W/cm² intensity; and CGIV, using 3-MHz frequency and 2-W/cm² intensity. For each control group, its respective test group (TG) was denominated TGI, TGII, TGIII and TGIV. The TUS was applied to the lateral aspect of the thigh using the continuous mode and a 3.5-cm² transducer in a 6.25-cm² area for 2 minutes. Sensors were coupled to digital thermometers that measured the temperature in different sites before (t0) and after (t1) of the TUS application. The temperatures in t1 were higher in all tested groups. The intramuscular temperature was significantly higher (P<0.05) in the groups used to test the 3-MHz frequency in the presence of the metal plate. The therapeutic ultrasound in the continuous mode using frequencies of 1 and 3 MHz and intensities of 1 and 2 W/cm2 for 2 minutes caused heating of the metal plate and adjacent structures after fixation to the femur of canine cadavers...


O objetivo deste estudo foi avaliar o aquecimento gerado pelo ultrassom terapêutico (UST) na placa óssea metálica e estruturas adjacentes após a fixação no fêmur de cadáveres caninos. Foram utilizados dez pares de membros pélvicos, distribuídos igualmente entre os grupos que utilizaram as frequências de 1 e 3 MHz. Cada frequência testou as intensidades de 1 e 2 W/cm², sendo que o membro pélvico direito foi definido grupo controle (ausência da placa óssea metálica) e o membro pélvico esquerdo o grupo teste (presença da placa óssea metálica). Portanto, os grupos controles foram denominados GCI, com UST na frequência de 1 MHz e intensidade de 1 W/cm²; GCII, com 1 MHz e 2 W/cm²; GCIII, com frequência de 3 MHz e intensidade de 1 W/cm²; e GCIV, com 3 MHz e 2 W/cm². Para cada grupo controle, seu respectivo grupo teste foi denominado GTI, GTII, GTIII e GTIV. O UST foi aplicado na face lateral da coxa, utilizando o modo contínuo, transdutor de 3,5cm², em uma área de 6,25cm², durante dois minutos. Foram utilizados sensores acoplados a termômetros digitais que mediram a temperatura em diferentes locais antes (t0) e após (t1) a aplicação do UST. Pode-se verificar que as temperaturas em t1 foram maiores em todos os grupos testados. Os grupos que testaram a frequência de 3 MHz demonstraram que a temperatura intramuscular foi significativamente maior (P<0,05) na presença da placa óssea metálica. O ultrassom terapêutico no modo contínuo de 1 e 3 MHz e intensidades de 1 e 2 W/cm2 durante dois minutos promove o aquecimento da placa óssea metálica e estruturas adjacentes após a fixação no fêmur de cadáveres caninos...


Assuntos
Animais , Cães , Ossos Pélvicos/ultraestrutura , Placas Ósseas/efeitos adversos , Placas Ósseas/veterinária , Ultrassonografia/veterinária , Calefação/instrumentação , Contratura/veterinária , Fêmur , Especialidade de Fisioterapia
7.
Pesqui. vet. bras ; 33(10): 1201-1207, Oct. 2013. ilus, graf
Artigo em Português | LILACS | ID: lil-697159

RESUMO

A evolução tecnológica tem possibilitado o desenvolvimento e o aperfeiçoamento de novos materiais para implantes. Apesar dos fundamentais benefícios providos pelos dispositivos ortopédicos, complicações decorrentes de corrosão, degradação, infecção, além de outras podem ocorrer. O entendimento das características dos biomateriais é fundamental para a previsibilidade do seu comportamento in vivo, fornecendo subsídios para que o composto mais adequado seja escolhido na reconstrução do defeito ósseo. As placas de origem metálica são as mais utilizadas para o reparo de fraturas de ossos longos, sendo mecanicamente resistentes e biocompatíveis. No entanto, a necessidade de remoção e o enfraquecimento do osso são suas principais desvantagens. Neste trabalho, placas produzidas a partir de osso cortical equino foram empregadas experimentalmente em fêmur osteotomizado de coelhos (Grupo osso-GO), num estudo comparativo com placas de metal (Grupo metal-GM). A avaliação radiográfica foi realizada a cada 30 dias, durante 120 dias, momento em que foi então realizada análise histológica do material em estudo. Não houve diferença estatisticamente significante entre os dois grupos com relação à morfometria do calo ósseo e consolidação óssea em todos os momentos avaliados, sendo que ambas as placas permitiram a consolidação em todos os animais. Entretanto, observou-se que o calo ósseo foi menor no GO, em relação ao GM, em todos os momentos do estudo. Por outro lado, a maior parte dos animais do GO apresentou consolidação completa da fratura aos 90 dias, enquanto que no GM isto ocorreu aos 60 dias. Não foram evidenciadas células do tipo corpo estranho na histopatologia dos animais do GO, mas maior quantidade de tecido fibroso foi identificada, envolvendo este biomaterial. A placa confeccionada com osso equino representa uma alternativa de baixo custo e muito viável, uma vez que permitiu estabilização adequada para consolidação óssea de fratura de fêmur em ...


Actually, technological advances have contributed to the development and improvement of new materials for implants. Despite the fundamental benefits provided by orthopedic materials, complications resulting from corrosion, degradation, infection, and others may occur. The knowledge of characteristics of the biomaterials is important to predict their behavior in vivo, supporting that the most suitable compound is chosen to reconstruct the bone defect. Metallic plates are the most common material used for repair of long bone fractures, and they are mechanically stable and biocompatible. However, the need of removal and bone weakening are their disadvantages. In this paper, plates made from equine cortical bone were used experimentally in osteotomized rabbit femur (bone-GO Group), in a comparative study with metal plates (metal GM Group). Radiographic evaluation was performed every 30 days during 120 days, at which time was then performed femur histological analysis. During all evaluated moments of the study, there was no statistically significant difference between the two groups in callus morphometry, and complete consolidation was observed in all animals. However, it was observed that the callus was lower in GO compared to GM, all times during the study. Moreover, most of the GO animals showed complete consolidation fracture at 90 days only, whereas this occurred in GM at 60 days. There were no foreign-body cells in the histopathology exam of the GO animals, but larger amount of fibrous tissue was identified, involving this biomaterial. The plate made from horse bone represents a low cost alternative and it is very feasible, it allowed adequate stabilization of femur fracture in rabbits. In this study, the lower periosteal callus associated with a longer time for consolidation in GO suggest greater fracture stability when the bone plate was used.


Assuntos
Animais , Adulto , Coelhos/lesões , Fixação de Fratura/veterinária , Próteses e Implantes/veterinária , Placas Ósseas/veterinária , Radiografia/veterinária
8.
Int. j. morphol ; 26(4): 791-797, Dec. 2008. ilus, tab, graf
Artigo em Espanhol | LILACS | ID: lil-532978

RESUMO

Los objetivos generales fueron: evaluar resistencia a la compresión del fémur derecho aislado y del fémur izquierdo osteotomizado transversalmente fijado con una placa ortopédica fabricada en polipropileno, y comparar las características mecánicas estáticas entre ambos. Este trabajo se realizó mediante la confección de un modelo experimental de carga constituido por un fémur de mamífero (perro) en condiciones aisladas. Se utilizaron los huesos fémur de 13 perros mestizos, adultos jóvenes, de talla mediana a grande. Para los pruebas se utilizó una máquina servohidráulica para ensayos estáticos y dinámicos Amsler Wolpert. Se utilizó para el tratamiento de los datos, el test estadístico de diferencias de medias para muestras pareadas dependientes. Como resultado del análisis de las curvas se obtuvo que: el fémur derecho soportó antes de la falla, entre 4,02 a 8,47 KN de carga (= 6,66 KN) con una deformación de 2,02 a 5,09 mm (= 3,66 mm). En tanto el conjunto fémur izquierdo + placa ortopédica soportó antes de la falla, entre 3,05 a 5,61 KN de carga (= 4,49 KN) con una deformación de 2 a 4.5 mm (= 3 mm). Como conclusión, es posible afirmar que hay diferencias en la resistencia a la carga compresiva entre el fémur derecho y su contralateral izquierdo + placa ortopédica.


The general aims were: to evaluate the resistance to compression of the right femur isolated and that of the left femur transversally osteotomized fixed to an orthopedic plate made of polypropylene and to compare the mechanical statistical characteristics between both. This work was carried out by performing an experimental charge pattern made of a mammal femur (dog) under isolated conditions. Femur bones of 13 hybrid young adult dogs of medium to large size were used. A servohydric engine was used for the Amsler Wolpert static and dynamic essays. The mean difference statistical test for depending paired samples was used for the evaluation of data. As a result of the curves analysis it was obtained that: before failure the right femur underwent a charge of 4.02 to 8.47 KN (= 6.66 KN) with a deformation of 2.02 to 5.09 mm (= 3.66mm) while the charge that the left femur + orthopedic plate underwent before de failure was of 3.05 to 5.61 KN ( = 4.49KN) with a deformation of 2 to 4.5 mm ( = 3mm). As a conclusion it might be stated that there are differences in the resistance to the compressive charge between right femur and its left contra lateral + the orthopedic plate.


Assuntos
Animais , Cães , Fenômenos Biomecânicos , Fêmur/fisiologia , Polipropilenos , Cães/fisiologia , Placas Ósseas/veterinária , Procedimentos Ortopédicos/métodos , Aparelhos Ortopédicos/veterinária , Fêmur/cirurgia , Força Compressiva/fisiologia , Ciência dos Materiais , Modelos Biológicos , Osteotomia , Suporte de Carga/fisiologia
9.
Journal of Veterinary Science ; : 193-196, 2008.
Artigo em Inglês | WPRIM | ID: wpr-75536

RESUMO

We performed biomechanical comparison of a xenograft bone plate-screw (XBPS) system for achieving cadaveric lumbar transpedicular stabilization (TS) in dogs. Twenty dogs' cadaveric L2-4 lumbar specimens were harvested and their muscles were removed, but the discs and ligaments were left intact. These specimens were separated to four groups: the L2-4 intact group as control (group I, n = 5), the L3 laminectomy and bilateral facetectomy group (LBF) (group II, n = 5), the LBF plus TS with metal plate-screw group (group III, n = 5) and the LBF plus TS with XBPS group (group IV, n = 5). Five kinds of biomechanical tests were applied to the specimens: flexion, extension, left-right bending and rotation. The averages of the 16 stiffness values were calculated and then these were statistically analyzed. The statistical results show that the XBPS system contributes spinal stability and this system can be a good choice for achieving TS.


Assuntos
Animais , Cães , Fenômenos Biomecânicos , Placas Ósseas/veterinária , Parafusos Ósseos/veterinária , Cadáver , Vértebras Lombares/fisiologia , Amplitude de Movimento Articular/fisiologia , Fusão Vertebral/instrumentação , Transplante Heterólogo/instrumentação
10.
Botucatu; s.n; 2006. 95 p. ilus, tab.
Tese em Português | LILACS | ID: lil-457078

RESUMO

O trabalho teve por objetivos avaliar por meio de exames clínicos, radiográficos e histológicos, defeitos ósseos segmentares induzidos em tíbia de ovinos, tratados com placa metálica associada a um Gage, que foi preenchido com enxerto cortical autólogo ou biomateriais. Foram utilizados 12 ovinos hígidos com idade entre quatro e cinco meses, divididos em dois grupos, G1 (n=6) e G2 (n=6). Removeu-se um segmento da porção média da diáfise tibial direita de 3,5 cm de extensão e, em ambos os grupos, o defeito segmentar foi tratado pela colocação de uma placa combinada a um Cage de titânio. O Cage foi preenchido no G1 com fragmentos de osso cortical autólogo obtidos do segmento ósseo tibial excisado, e no G2 com enxerto ósseo liofilizado composto, contendo osso bovino inorgânico, matriz bovina orgânica, aglutinante natural de colágeno e pool de BMPs de origem bovina absorvidas à hidroxiapatita sintética absorvível ultrafina, misturado com 1 ml de sangue do próprio animal. Com exceção de um animal do G1, todos os outros apresentaram função normal do membro após 60 dias da cirurgia. O exame radiográfico mostrou, aos 15 dias de pós-operatório, o entortamento da placa (3º-9º) na transição entre placa e Cage em quatro animais do G1 e um do G2. Nenhuma modificação da placa foi detectada nos outros momentos de observação. Aos 15 dias de pós-operatório já era visibilizado em todos os ovinos a formação do calo periotestal, que se localiza nas extremidades osteotomizadas e sobre a placa de Cage. Aos 30 dias de pós-operatório, a produção de calo estava mais acentuada, cobrindo quase totalmente o Cage. Aos 60 e 90 dias de pós-operatório notava-se a organização do processo. Os animais foram submetidos à eutanásia aos 90 dias de pós-operatório e as tíbias foram colhidas para avaliação histológico. O exame histológico revelou neoformação óssea nas falhas segmentares de ambos os grupos, porém comparativamente o tecido ósseo neoformado em G1 mostrou-se mais imaturo em relação a G2....


Assuntos
Animais , Cirurgia Veterinária/métodos , Materiais Biocompatíveis/uso terapêutico , Placas Ósseas/veterinária , Ovinos , Transplante Ósseo/veterinária
11.
Arq. bras. med. vet. zootec ; 45(1): 35-41, fev. 1993.
Artigo em Português | LILACS | ID: lil-240199

RESUMO

Dez cäes da raça Fila Brasileiro, em fase de crescimento, foram utilizados para avaliar o emprego de placas ósseas de cloreto de polivinila no tratamento de fraturas completas do terço distal do rádio e da ulna. Näo foram utilizados meios externos de imobilizaçäo. Clinicamente, os animais näo mostraram quaisquer anormalidades durante o período de observaçäo. A consolidaçäo da fratura, evidenciada radiologicamente, ocorreu dentro do tempo esperado


Assuntos
Animais , Cães , Fraturas do Rádio/reabilitação , Placas Ósseas/veterinária , Fraturas da Ulna/reabilitação