Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Adicionar filtros








Intervalo de ano
1.
Arq. bras. oftalmol ; 69(6): 837-843, nov.-dez. 2006. tab
Artigo em Português | LILACS | ID: lil-440421

RESUMO

OBJETIVO: Avaliar a segurança, eficiência e custos do exame angiofluoresceinográfico utilizando menor dosagem de contraste e aparelho digital com máquina de fotocópia a laser. MÉTODOS: Estudo prospectivo e comparativo entre um grupo de 70 pacientes que foi submetido à avaliação angiográfica com retinógrafo convencional, injetando-se 5 ml de fluoresceína sódica a 10 por cento (grupo controle), e um grupo de 70 pacientes que foi submetido à avaliação angiográfica com retinógrafo digital injetando-se 2 ml de fluoresceína a 10 por cento (grupo estudo). Pressão arterial, freqüência cardíaca e oximetria foram avaliadas antes e após a injeção de contraste. Reações orgânicas, relacionadas ao exame, foram notificadas. A qualidade das fotografias e os custos foram comparados entre as duas técnicas. RESULTADOS: Observou-se que os pacientes do grupo controle apresentaram maior aumento da pressão arterial sistólica e diastólica. Freqüência cardíaca, oximetria e reações adversas não demonstraram diferenças estatisticamente significativas entre os dois grupos. Quanto à qualidade das fotografias foi notado melhor desempenho no grupo controle. Quanto aos custos observou-se que o exame realizado no grupo estudo proporcionou economia de aproximadamente 54,8 por cento por exame em relação ao grupo controle. CONCLUSÃO: A realização do exame com menor dosagem de fluoresceína, utilizando equipamento digital com máquina de fotocópia a laser, proporcionou maior estabilidade da pressão arterial sistólica e diastólica, porém não exerceu influência sobre a freqüência cardíaca, oximetria e reações adversas como náusea, vômito, síncope e urticária. A qualidade das fotografias pode ser considerada inferior, porém possibilitou a realização de diagnóstico e orientação terapêutica para quem executou o exame. Economicamente apresentou geração de lucro de 66,26 por cento contra 25,81 por cento do equipamento convencional.


PURPOSE: To evaluate the safety, effectiveness, and cost of angiofluoresceinographic examination by using both the least amount of dye as well as digital equipment along with a laser photocopier. METHODS: Prospective and comparative study carried out in a group of 70 patients, who underwent an angiographic evaluation with a conventional retinographer injecting 5 ml sodium fluorescein at 10 percent (control group) as well as a group of 70 patients who underwent an angiographic evaluation with a digital retinographer injecting 2 ml fluorescein at 10 percent (study group). Arterial pressure, heart rate and oximetry were assessed prior to and after the dye injection. Organic reactions related to the examination were reported. Photograph quality as well as cost between the two techniques were compared. RESULTS: Control group patients showed a greater increase in systolic and diastolic arterial pressure. Heart rate, oximetry measurement and adverse reactions did not show any significant statistical differences between both groups. As for the quality of photographs, a better performance was noticed in the control group. As for the cost, the examination carried out in the study group required lower cost and thus saved around 54.8 percent per examination in relation to the control group. CONCLUSION: The examination carried out with a lower dose of fluorescein using digital equipment along with a laser photocopier provided greater stability in the systolic and diastolic arterial pressure. However, it did not have any influence on heart rate, oximetry or adverse reactions such as nausea, vomiting, syncope and rashes. The quality of photographs was poor although they enabled diagnosis as well as therapy follow-up for those who carried out the examination. Moreover, economically the above procedure represented a gain of 66.26 percent, against 25.81 percent in relation to the conventional equipment.


Assuntos
Humanos , Meios de Contraste/administração & dosagem , Angiofluoresceinografia/economia , Angiofluoresceinografia/normas , Fluoresceína/administração & dosagem , Doenças Retinianas/diagnóstico , Angiografia Digital/economia , Angiografia Digital/métodos , Angiografia Digital/normas , Pressão Sanguínea/efeitos dos fármacos , Custos e Análise de Custo , Meios de Contraste/efeitos adversos , Processos de Cópia/normas , Angiofluoresceinografia/métodos , Fluoresceína/efeitos adversos , Frequência Cardíaca/efeitos dos fármacos , Lasers , Oximetria , Estudos Prospectivos , Fatores de Tempo , Vômito/etiologia
2.
Cienc. Trab ; 7(15): 21-26, ene.-mar. 2005. ilus
Artigo em Espanhol | LILACS | ID: lil-420798

RESUMO

Se realizó una recopilación de información técnica y científica, con el propósito de demostrar los potenciales riesgos existentes en las máquinas fotocopiadoras, tanto para los operadores como para los especialistas de servicios técnicos. Asimismo, se detectó la falta de conocimiento respecto de estos riesgos, a los que se ven diariamente enfrentadas las personas, condición que motivó el desarrollo de esta investigación, proponiéndose un protocolo de seguridad para todos aquéllos que se relacionan permanentemente con este tipo de máquinas, tanto en su trabajo diario como en un contacto periódico de mantenimiento.


Assuntos
Humanos , Prevenção de Acidentes , Saúde Ocupacional , Processos de Cópia/normas , Acidentes por Descargas Elétricas , Chile , Temperatura Alta/efeitos adversos , Campos Eletromagnéticos/efeitos adversos , Ozônio/efeitos adversos , Poliestirenos/efeitos adversos , Raios Ultravioleta/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA