Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Braz. arch. biol. technol ; 64(spe): e21210196, 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1278463

RESUMO

Abstract Recent technological advances and increased participation of energy systems based on photovoltaic solar energy place this renewable energy source in a prominent position in the current scenario. With the increase in the share of solar photovoltaic systems, the impact of power fluctuations in these sources has worsened, which can affect the quality of electrical energy and the reliability of the electrical power system. Therefore, with the use of energy storage together with control algorithms based on artificial intelligence, it is possible to control and perform power smoothing. In this context, the study presents a technical feasibility study on the use of artificial neural network (ANN) to perform the power smoothing of the photovoltaic system connected to the network. Being studied the performance of a real photovoltaic system operating in conjunction with an ideal energy storage for comparative analysis of the performance of the artificial neural network when the numbers of neurons and layers are modified for different real operating conditions considered as temperature variation, humidity, irradiation, pressure and wind speed, which are considered to be ANN input data. The results obtained point to the feasibility of using ANN, with acceptable precision, for power smoothing. According to the analyzes carried out, it is clear that ANN's with few neurons, the smoothing profile tends to be more accurate when compared to larger amounts of neurons. In the current state of the study, it was not possible to determine a relationship between the variations in the number of neurons with the most accurate results, it is important to note that the development of the curve pointed by the neural network can be influenced by the database. It should be noted that, when ANN exceeds or does not reach the optimal smoothing curve, the storage system compensates for the lack or excess of power, and there is a need for other mechanisms to optimize power smoothing.


Assuntos
Energia Solar , Redes Neurais de Computação , Fontes Geradoras de Energia , Sistemas Microeletromecânicos/métodos , Inteligência Artificial , Estudos de Viabilidade
2.
Adv Rheumatol ; 60: 14, 2020. tab
Artigo em Inglês | LILACS | ID: biblio-1088650

RESUMO

Abstract Introduction: Atrial fibrillation (AF) is the leading cause of ischemic stroke and is one of the most common arrhythmias. Previous studies have shown that impaired diastolic functions, P wave dispersion (Pd), and prolonged atrial conduction times (ACT) are associated with increased incidence of atrial fibrillation (AF). The aim of this study was to evaluate diastolic functions, Pd, and ACT in fibromyalgia syndrome (FMS) patients to determine whether there is an increase in the risk of developing AF. Methods: The study included a total of 140 female patients (70 FMS group, 70 healthy control group). Pd was evaluated using 12 lead electrocardiography (ECG), and diastolic functions and ACT with echocardiography. The ECG and echocardiographic evaluations were performed by different cardiologists blinded to the clinical information of the subjects. Results: There was no difference between the two groups in laboratory and clinical parameters. Patients with FMS had significantly higher echocardiographic parameters of ACT known as left-sided intra-atrial (13.9 ± 5.9 vs. 8.1 ± 1.8, p < 0.001), right-sided intra-atrial (21.9 ± 8.2 vs. 10.4 ± 3.5, p < 0.001) and interatrial [40 (25-64) ms vs. 23 (14-27) ms p < 0.001] electromechanical interval (EMI) compared with the control group. Pd was significantly greater in the FMS group compared with the control group [46 (29-62) ms vs. 32 (25-37) ms, p < 0.001]. In the FMS group, there was no significant relationship of the echocardiographic parameters of ACT, Pmax and Pd with age, E/A ratio and deceleration time (DT); while all these five parameters were significantly correlated with left atrial dimension, isovolumetric relaxation time (IVRT), fibromyalgia impact questionnaire (FIQ) and visual analogue scale (VAS). There was a strong correlation between FIQ and VAS and echocardiographic parameters of ACT, Pmax and Pd. Conclusions: Impaired diastolic functions, an increase in Pd, and prolongation of ACT were observed in FMS. Current disorders are thought to be associated with an increased risk of AF in FMS. The risk of developing AF increases with the severity of FMS and clinical progression.(AU)


Assuntos
Humanos , Fibrilação Atrial/diagnóstico , Fibromialgia/fisiopatologia , Eletrocardiografia/instrumentação , Sistemas Microeletromecânicos
3.
Clinical Psychopharmacology and Neuroscience ; : 288-296, 2019.
Artigo em Inglês | WPRIM | ID: wpr-763528

RESUMO

OBJECTIVE: The purpose of this study was to examine post-hospitalization outpatient drug adherence in patients with severe psychiatric illness, including bipolar disorder and schizophrenia, and to investigate factors associated with drug adherence. METHODS: Eighty-one patients diagnosed with schizophrenia or bipolar disorder who were hospitalized due to aggravation of psychiatric symptoms were monitored. At hospitalization, we conducted clinical assessments such as the Clinical Global Impression-Severity, Drug Attitude Inventory, Contour Drawing Rating Scale, Multidimensional Scale of Perceived Social Support scale, and patients' demographic factors. We measured drug adherence using the Medication Event Monitoring System (MEMS), pill count, and patients' self-report upon out-patients visits, 4 and 24 weeks after discharge. RESULTS: The mean values of the various measures of adherence were as follows: MEMS (4 weeks) 84.8%, pill count (4 weeks) 94.6%, self-report (4 weeks) 92.6%, MEMS (24 weeks) 81.6%, pill count (24 weeks) 90.6%, and self-report (24 weeks) 93.6%. The adherence agreement between MEMS, pill count, and self-report was moderate (4 weeks intra-class correlation [ICC]=0.54, 24 weeks ICC=0.52). Non-adherence (MEMS ≤0.08) was observed in 26.4% of the patients at 4 weeks and 37.7% at 24 weeks. There was a negative correlation between drug adherence assessed 4 weeks after discharge and Contour Drawing Rating Scale difference score (r=−0.282, p<0.05). A positive correlation was found between drug adherence assessed 24 weeks after discharge and Drug Attitude Inventory (r=0.383, p<0.01). CONCLUSION: Patients' attitude towards their medication and their degree of physical dissatisfaction influenced post-hospitalization drug adherence in severe psychiatric patients.


Assuntos
Humanos , Transtorno Bipolar , Demografia , Monitoramento de Medicamentos , Hospitalização , Adesão à Medicação , Sistemas Microeletromecânicos , Pacientes Ambulatoriais , Esquizofrenia
4.
Chinese Journal of Medical Instrumentation ; (6): 307-309, 2019.
Artigo em Chinês | WPRIM | ID: wpr-772499

RESUMO

This capacitive venous transfusion alertor is based on rise time of RC circuit and input capture function of timer in the microcontroller. The measure element of alertor is integrated with circuit board, it has the advantages of simple structure and low cost. Combined with narrow band intent of things(NB-IoT) technology to upload data, it can reduce the workload of medical personnel and caregivers, avoid unnecessary trouble and danger.


Assuntos
Algoritmos , Transfusão de Sangue , Padrões de Referência , Desenho de Equipamento , Padrões de Referência , Sistemas Microeletromecânicos , Padrões de Referência
5.
Chinese Journal of Medical Instrumentation ; (6): 337-340, 2019.
Artigo em Chinês | WPRIM | ID: wpr-772491

RESUMO

The paper describes how to develop a digital heart sound signal detection device based on high gain MEMS MIC that can accurately collect and store human heart sounds. According to the method of collecting heart sound signal by traditional stethoscope, the system improves the traditional stethoscope, and a composite probe equipped with a MEMS microphone sensor is designed. The MEMS microphone sensor converts the sound pressure signal into a voltage signal, and then amplifies, converts with Sigma Delta, extracts and filters the collected signal. After the heart sound signal is uploaded to the PC, the Empirical Mode Decomposition (EMD) is carried out to reconstruct the signal, and then the Independent Component Analysis (ICA) method is used for blind source separation and finally the heart rate is calculated by autocorrelation analysis. At the end of the paper, a preliminary comparative analysis of the performance of the system was carried out, and the accuracy of the heart sound signal was verified.


Assuntos
Humanos , Coração , Ruídos Cardíacos , Sistemas Microeletromecânicos , Processamento de Sinais Assistido por Computador , Estetoscópios
6.
Hanyang Medical Reviews ; : 235-241, 2016.
Artigo em Inglês | WPRIM | ID: wpr-132264

RESUMO

Various microrobots are being studied for potential biomedical applications including targeted cell transportation, precise drug delivery, opening blocked blood vessels, micro-surgery, sensing, and scaffolding. Precise magnetic field control system is a coil system for wireless control of those microrobots for personalized and minimally invasive treatments. The microrobots for possible biomedical applications are fabricated by micro-electro-mechanical systems (MEMS) and nano-electro-mechanical systems (NEMS) technologies. In this review, fabrication technologies for scaffold and ciliary microrobots will be introduced and their control methods will be discussed. Various materials are being used for the fabrication of the microrobot such as SU-8, IP-Dip, IP-L, silicon, etc. The scaffold and ciliary microrobots are fabricated by SU-8, IP-Dip, and IP-L because these materials showed the maximum performance for three-dimensional (3D) microrobots using a 3D laser lithography system. All or part of the structures are coated with nickel and titanium layers after fabrication of the structures for magnetic control and biocompatibility, respectively, of the microrobots.


Assuntos
Humanos , Vasos Sanguíneos , Campos Magnéticos , Sistemas Microeletromecânicos , Níquel , Silício , Titânio , Meios de Transporte
7.
Hanyang Medical Reviews ; : 235-241, 2016.
Artigo em Inglês | WPRIM | ID: wpr-132261

RESUMO

Various microrobots are being studied for potential biomedical applications including targeted cell transportation, precise drug delivery, opening blocked blood vessels, micro-surgery, sensing, and scaffolding. Precise magnetic field control system is a coil system for wireless control of those microrobots for personalized and minimally invasive treatments. The microrobots for possible biomedical applications are fabricated by micro-electro-mechanical systems (MEMS) and nano-electro-mechanical systems (NEMS) technologies. In this review, fabrication technologies for scaffold and ciliary microrobots will be introduced and their control methods will be discussed. Various materials are being used for the fabrication of the microrobot such as SU-8, IP-Dip, IP-L, silicon, etc. The scaffold and ciliary microrobots are fabricated by SU-8, IP-Dip, and IP-L because these materials showed the maximum performance for three-dimensional (3D) microrobots using a 3D laser lithography system. All or part of the structures are coated with nickel and titanium layers after fabrication of the structures for magnetic control and biocompatibility, respectively, of the microrobots.


Assuntos
Humanos , Vasos Sanguíneos , Campos Magnéticos , Sistemas Microeletromecânicos , Níquel , Silício , Titânio , Meios de Transporte
8.
International Neurourology Journal ; : 98-106, 2013.
Artigo em Inglês | WPRIM | ID: wpr-68528

RESUMO

From the first pacemaker implant in 1958, numerous engineering and medical activities for implantable medical device development have faced challenges in materials, battery power, functionality, electrical power consumption, size shrinkage, system delivery, and wireless communication. With explosive advances in scientific and engineering technology, many implantable medical devices such as the pacemaker, cochlear implant, and real-time blood pressure sensors have been developed and improved. This trend of progress in medical devices will continue because of the coming super-aged society, which will result in more consumers for the devices. The inner body is a special space filled with electrical, chemical, mechanical, and marine-salted reactions. Therefore, electrical connectivity and communication, corrosion, robustness, and hermeticity are key factors to be considered during the development stage. The main participants in the development stage are the user, the medical staff, and the engineer or technician. Thus, there are three different viewpoints in the development of implantable devices. In this review paper, considerations in the development of implantable medical devices will be presented from the viewpoint of an engineering mind.


Assuntos
Humanos , Materiais Biocompatíveis , Engenharia Biomédica , Pressão Sanguínea , Implantes Cocleares , Corrosão , Eletrônica Médica , Corpo Clínico , Sistemas Microeletromecânicos
9.
International Neurourology Journal ; : 2-10, 2013.
Artigo em Inglês | WPRIM | ID: wpr-102168

RESUMO

We present the construction of the lab-on-a-chip (LOC) system, a state-of-the-art technology that uses polymer materials (i.e., poly[dimethylsiloxane]) for the miniaturization of conventional laboratory apparatuses, and show the potential use of these microfluidic devices in clinical applications. In particular, we introduce the independent unit components of the LOC system and demonstrate how each component can be functionally integrated into one monolithic system for the realization of a LOC system. In specific, we demonstrate microscale polymerase chain reaction with the use of a single heater, a microscale sample injection device with a disposable plastic syringe and a strategy for device assembly under environmentally mild conditions assisted by surface modification techniques. In this way, we endeavor to construct a totally integrated, disposable microfluidic system operated by a single mode, the pressure, which can be applied on-site with enhanced device portability and disposability and with simple and rapid operation for medical and clinical diagnoses, potentially extending its application to urodynamic studies in molecular level.


Assuntos
Equipamentos Descartáveis , Dispositivos Lab-On-A-Chip , Sistemas Microeletromecânicos , Microfluídica , Miniaturização , Plásticos , Reação em Cadeia da Polimerase , Polímeros , Seringas , Urodinâmica
10.
Journal of Korean Geriatric Psychiatry ; : 26-31, 2013.
Artigo em Coreano | WPRIM | ID: wpr-48552

RESUMO

OBJECTIVES: Many patients with Alzheimer's disease have difficulty in taking their medicine by themselves and their poor drug adherence possibly results in aggravating various symptoms. The aim of this study was to assess the variables influencing drug adherence of Alzheimer's disease patients. METHODS: In a four-week period, 33 outpatients over 65 years old diagnosed with Alzheimer's disease were monitored. Drug adherences were assessed by the Medication Event Monitoring System (MEMS), the pill count, the clinician rating scale, and self-report. Agreements among adherence measures and the relationships between MEMS adherence and other clinical factors were assessed. RESULTS: The adherence rates for the MEMS, the pill count, the clinician rating scale and, self-report were 51.5%, 82.8%, 82.8%, and 87.9%. The Kappa coefficients were 0.382 (pill count vs. MEMS, clinician rating scale vs. MEMS) and 0.256 (self-report vs. MEMS). Males showed better adherence than females but the other clinical variables did not show significant differences between adherence group and non-adherence group. CONCLUSION: These findings suggest that clinicians should be concerned when assessing drug adherence in patients with Alzheimer's disease only by subjective reporting and pill counting since these methods may make patient's adherence underestimate. Clinicians should also take in mind that caregivers play an important role in improving adherence.


Assuntos
Feminino , Humanos , Masculino , Doença de Alzheimer , Cuidadores , Demência , Sistemas Microeletromecânicos , Pacientes Ambulatoriais
11.
Chinese Journal of Medical Instrumentation ; (6): 407-410, 2013.
Artigo em Chinês | WPRIM | ID: wpr-264175

RESUMO

The paper proposed a new method to design and fabricate a flexible neural microelectrode arrays (MEA) for retinal prosthesis, the ion-beam technology was introduced to decrease the width of conductive wires and the distances between wires, a high density MEA (120 microelectrodes with a matrix of 10 x 12) was fabricated on a single layer of polymer from this. The MEA was proved to possess a fine electrochemical property. In vitro test, the average impedance of MEA on 1 kHz was 16 k omega +/- 2 k omega and the average phase difference was -85 degrees +/-30 degrees.


Assuntos
Sistemas Microeletromecânicos , Microeletrodos , Desenho de Prótese , Próteses Visuais
12.
Psychiatry Investigation ; : 263-268, 2012.
Artigo em Inglês | WPRIM | ID: wpr-119420

RESUMO

OBJECTIVE: The primary aim of this study was to compare electronic monitoring with other measures of adherence to Osmotic-controlled Release Oral delivery System methylphenidate in children with attention-deficit hyperactivity disorder (ADHD). The secondary aim was to analyze the relationships between adherence and clinical factors, including ADHD symptoms. METHODS: Thirty-nine children diagnosed with ADHD were monitored for adherence to medication over the course of eight weeks. Medication adherence was assessed using the Medication Event Monitoring System (MEMS), which is a bottle cap with a microprocessor that records all instances and times that the bottle is opened; patient self-report; clinician rating; and pill count. Information, including demographic and clinical characteristics, symptom rating scale, and psychological test results, were also collected. The relationships between adherence and clinical factors, including ADHD rating scores of baseline and of the changes, were assessed. RESULTS: The rate of non-adherence measured by the MEMS was found to be 46.2%, which was considerably higher than those of the patient self-report (17.9%), clinician rating (31.7%), and pill count (12.8%) of non-adherence. The rate of adherence measured by the MEMS was not significantly associated with baseline symptom severity or symptom changes over the eight weeks, although non-adherent group showed more severe baseline symptoms and inferior improvement. CONCLUSION: Adherence as measured by the MEMS showed a discrepancy with other measures of adherence in patients with ADHD. The symptom severity and level of improvement were not related to adherence with MEMS. Further studies are needed to evaluate the variables that may impact medication adherence in children with ADHD.


Assuntos
Criança , Humanos , Transtorno do Deficit de Atenção com Hiperatividade , Eletrônica , Elétrons , Adesão à Medicação , Metilfenidato , Sistemas Microeletromecânicos , Microcomputadores , Testes Psicológicos
13.
Chinese Journal of Stomatology ; (12): 600-603, 2011.
Artigo em Chinês | WPRIM | ID: wpr-306379

RESUMO

<p><b>OBJECTIVE</b>To design and build the micro-stress sensor measurement system for invisible aligner technique.</p><p><b>METHODS</b>A measurement system based on silicon-on-insulator piezoresistive stress sensor was developed. A four-point-bending based experimental apparatus was constructed to calibrate the piezoresistive coefficients of this stress sensor. A chemical-mechanical polishing process was developed for thinning the stress sensor dies. A packaging solution using flexible printed circuit to get signals out was designed.</p><p><b>RESULTS</b>The developed silicon stress sensor chip was 7.0 mm × 6.0 mm × 0.1 mm in size, and 13 sensor rosettes and 4 calibration rosettes were fabricated in one sensor. And a main testing PCB and a Lab View program were designed to carry out the automation measurement of the stress sensor. The stress state during the process was obtained through this test system. And measuered the stress of the 13 sensor unit.</p><p><b>CONCLUSIONS</b>A stress measurement system was established for measuring stress during orthodontic treatment with invisable aligner.</p>


Assuntos
Calibragem , Análise do Estresse Dentário , Desenho de Equipamento , Análise de Elementos Finitos , Sistemas Microeletromecânicos , Métodos , Aparelhos Ortodônticos , Ortodontia Corretiva , Silício , Química , Estresse Mecânico
14.
Journal of Biomedical Engineering ; (6): 215-218, 2010.
Artigo em Chinês | WPRIM | ID: wpr-341650

RESUMO

This review summarized the progress of researches on the active locomotion system for capsule endoscope, analyzed the moving and controlling principles in different locomotion systems, and compared their merits and shortcomings. Owing to the complexity of human intestines and the limits to the size and consumption of locomotion system from the capsule endoscope, there is not yet one kind of active locomotion system currently used in clinical practice. The locomotive system driven by an outer rotational magnetic field could improve the commercial endoscope capsule, while its magnetic field controlling moving is complex. Active locomotion system driven by shape memory alloys will be the orientated development and the point of research in the future.


Assuntos
Animais , Humanos , Materiais Biomiméticos , Cápsulas Endoscópicas , Desenho de Equipamento , Locomoção , Magnetismo , Sistemas Microeletromecânicos , Movimento (Física) , Robótica
15.
Journal of Biomedical Engineering ; (6): 292-296, 2010.
Artigo em Chinês | WPRIM | ID: wpr-341632

RESUMO

In gynecology, it is very important to obtain the parameters of women's uterine musculature, such as its deformation size and contraction frequency, etc. This paper proposes a type of sensor for measuring these parameters and also analyzes its force situation. The sensor is flexible, deformable, and can adjust itself to the shape of the uterus. It can be put into the women's uterine cavity easily. The experiment shows that the sensitivity of the left and right sets coils of the sample sensor achieves 22.38 nH/mm2, while that of the top set coils achieves 22.84 nH/mm2, and the reaction time of the sensor is less than 200 ms. These results can meet the requirements of sensitivity and reaction time for testing the contraction situation of uterine musculature. The sensor has been applied in some medical fields.


Assuntos
Feminino , Humanos , Técnicas Biossensoriais , Desenho de Equipamento , Dispositivos Intrauterinos , Sistemas Microeletromecânicos , Contração Uterina , Fisiologia
16.
Korean Journal of Andrology ; : 169-174, 2010.
Artigo em Coreano | WPRIM | ID: wpr-87194

RESUMO

PURPOSE: Real-time monitoring of urinary bladder volume can not only provide information on urinary bladder function more precisely in laboratories and in the setting of intravesical pressure monitoring, but can also help areflexic neurogenic bladder patients have notice of the timing for optimal urination to prevent secondary complications. Thus we introduce a new implantable bladder volume monitoring device and its usefulness. MATERIALS AND METHODS: Ten male Sprague-Dawley rats were used under intraperitoneal anesthesia. Two microelectrodes produced by a micro-electrical-mechanical systems (MEMS) process were stitched onto each side wall of the urinary bladder and 25 G needles were inserted through the bladder dome. The distances between two microelectrodes converted from capacitances recorded by LCR meter were monitored in real-time during cystometry. Urinary bladder volume was estimated with its shape approximated as a sphere. RESULTS: Estimated bladder volume correlated well statistically with infused volume in (p0.05, repeated measures ANOVA). CONCLUSIONS: In our animal model, an implantable volume-monitoring device produced reliable data. Therefore, we expect that it should be an excellent tool for detecting urinary bladder volume and producing more accurate and useful information during urodynamic laboratory studies with small animals. Furthermore, we expect that this study will be the foundation of research for the clinical application of bladder volume monitoring devices to areflexic neurogenic bladder patients.


Assuntos
Animais , Humanos , Masculino , Ratos , Anestesia , Sistemas Microeletromecânicos , Microeletrodos , Modelos Animais , Agulhas , Ratos Sprague-Dawley , Bexiga Urinária , Bexiga Urinaria Neurogênica , Micção , Urodinâmica
17.
Chinese Journal of Biotechnology ; (12): 665-671, 2009.
Artigo em Chinês | WPRIM | ID: wpr-286659

RESUMO

Chitosan is a polymer with good biocompatibility, unique pH-responsive solubility, convenient modification and easier film-formability. Chitosan could serve as an active mediator between biological components and microfabricated devices to prepare biological micro electro mechanical systems (BioMEMS) with high selectivity and sensitivity. Recently, there has been a growing interest in BioMEMS based on biofabrication of chitosan. We reviewed the mechanisms and processes of three biofabrication methods based on chitosan, including directed assembly, enzymatic assembly and self-assembly. Current applications and research progress in biological, medical and environmental fields are also discussed. Finally, future research directions are prospected.


Assuntos
Materiais Biocompatíveis , Química , Biomimética , Técnicas Biossensoriais , Catálise , Quitosana , Química , Sistemas Microeletromecânicos , Métodos , Nanotecnologia , Hibridização de Ácido Nucleico
18.
Chinese Journal of Biotechnology ; (12): 315-322, 2008.
Artigo em Chinês | WPRIM | ID: wpr-276121

RESUMO

We designed a novel microcantilever immuosensor based on magnetic microbead, applying different-sized CdSe QDs as fluorescent probes and polystyrene magnetic microbead. The novel microcantilever immuosensor used fluorescent probes embedded polystyrene microbeads and specific antibodies on the surface of the polystyrene microbead. In addition, we studied the mechanism of the on-chip magnetic separation, the structure of micro-electromagnet and the microbead magnetization by the micro-magnetic field, the snake-shaped planar micro-electromagnet for the novel microcantilever immuosensor.


Assuntos
Anticorpos , Técnicas Biossensoriais , Métodos , Compostos de Cádmio , Química , Desenho de Equipamento , Imunoensaio , Métodos , Magnetismo , Sistemas Microeletromecânicos , Microesferas , Nanotecnologia , Poliestirenos , Química , Pontos Quânticos , Compostos de Selênio , Química
19.
Chinese Journal of Medical Instrumentation ; (6): 19-49, 2008.
Artigo em Chinês | WPRIM | ID: wpr-323231

RESUMO

A wireless energy transmission system for the MEMS system inside alimentary tracts is reported here in the paper. It consists of an automatic frequency tracking circuit of phase lock loop and phase shift PWM control circuit. Experimental results show that the energy transmission system is capable of automatic frequency-tracking and transmission power-adjusting and has stable received energy.


Assuntos
Sistema Digestório , Fontes de Energia Elétrica , Desenho de Equipamento , Sistemas Microeletromecânicos , Telemetria , Tecnologia sem Fio
20.
Journal of Biomedical Engineering ; (6): 1291-1294, 2007.
Artigo em Chinês | WPRIM | ID: wpr-230700

RESUMO

In this artical is first reported a survey of the progress in research of MEMS technology. Then, the basic structure, features and the principles of a massage device based on microcontroller in the field of alimentary tract are introduced. Special emphasis is laid on the utilization of MSP430F123 microprocessor for producing a kind of period pulse to control the power of massage capsule. In general, the research and development of the massage device in the field of alimentary tract have active support and deep significance to therapy in the clinical and business settings as well as in the development of biomedical engineering and MEMS.


Assuntos
Humanos , Desenho de Equipamento , Trato Gastrointestinal , Fisiologia , Massagem , Sistemas Microeletromecânicos , Microeletrodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA