Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Annals of Laboratory Medicine ; : 123-127, 2015.
Artigo em Inglês | WPRIM | ID: wpr-64360

RESUMO

Intermediate-resolution HLA-DQ typing has gained importance in organ transplantation recently. We evaluated the performance of the LIFECODES HLA-DQB1 typing kit (Immucor, USA) using sequence-specific oligonucleotide (SSO) probe and Luminex platform (Luminex Corp., USA) on 100 samples tested by sequence-based typing (SBT) using the AlleleSEQR HLA-DQB1 kit (Abbott Molecular, USA) in Korean individuals. No sample showed ambiguity in the assignment of 4-digit HLA-DQB1 allele with the LIFECODES HLA-DQB1 SSO typing kit, and the results were fully concordant with those of high-resolution typing of AlleleSEQR HLA-DQB1 SBT up to 4-digit level. Three samples required adjustment of false reactions (3/100, 3.0%): two samples with DQB1*03:03/*06:01 showed false-positive result in probe 253, and 1 sample with DQB1*04:02/*05:02 showed false-negative result in probe 217. We tested an additional sample with DQB1*03:03/*06:01, which showed same false-positivity in probe 253 and 2 samples with DQB1*04:02/*05:02, which showed no false reaction. The false reactions did not result in ambiguity or change in the HLA allele assignment. We could assign HLA-DQB1 alleles to 4 digit-level without ambiguity, with 100% concordance with the SBT results. Thus, LIFECODES HLA-DQB1 SSO typing kit showed good performance for intermediate-resolution HLA-DQB1 typing in clinical laboratory for organ transplantation in Koreans.


Assuntos
Humanos , Alelos , Primers do DNA/metabolismo , Frequência do Gene , Genótipo , Cadeias beta de HLA-DQ/genética , Teste de Histocompatibilidade/normas , Reação em Cadeia da Polimerase , Kit de Reagentes para Diagnóstico/normas , República da Coreia
2.
The Korean Journal of Laboratory Medicine ; : 442-450, 2007.
Artigo em Coreano | WPRIM | ID: wpr-161971

RESUMO

BACKGROUND: To monitor the performance of histocompatibility testing laboratories, HLA proficiency survey in Korea has been conducted biannually since 1996. In this report, we summarized the results of the surveys performed in recent two years (2005-2006). METHODS: A total of four proficiency surveys were performed, in which 59-61 laboratories participated. Each survey included three tests for HLA class I (serology and DNA) and class II (DNA) typing and six tests for HLA crossmatch. RESULTS: The overall concordance of serologic typing was 98.9% (355/359) for HLA-A, 97.5% (350/ 359) for HLA-B, and 94.7% (337/356) for HLA-C. The antigens assigned correctly by less than 95% of the participating laboratories were A26 (93.8%), B38 (94.2%), Cw3/Cw10 (90.9%), Cw6 (94.4%), and Cw8 (74.3%). The overall concordance rates of DNA typing were 99.6% (533/535) for HLA-A, 99.8% (539/540) for HLA-B, and 100% (392/392) for HLA-C. Correct assignment of HLA-DRB1 and -DQB1 was reported by 99.2% (98.1-100%) and 96.7% (88.9-100%) for the generic level and 100% and 95.8% (75-100%) for the allelic level, respectively. On the average 3.8% (0-7.7%) of the total laboratories showed unacceptable results in the crossmatch tests. CONCLUSIONS: The rates of correct antigen identification and of unacceptable crossmatch were similar to those of previous surveys, which were considered satisfactory. The Korean proficiency survey program may have contributed to a high quality of HLA tests today and should be continued for further improvements of the tests tomorrow.


Assuntos
Humanos , Alelos , Coleta de Dados , Antígenos HLA/sangue , Antígenos HLA-A/sangue , Antígenos HLA-B/sangue , Antígenos HLA-C/sangue , Antígenos HLA-DQ/sangue , Antígenos HLA-DR/sangue , Haplótipos , Teste de Histocompatibilidade/normas , Coreia (Geográfico) , Laboratórios , Controle de Qualidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA