Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Adicionar filtros








Intervalo de ano
1.
Arq. bras. med. vet. zootec ; 68(3): 641-650, tab, graf
Artigo em Inglês | LILACS, VETINDEX | ID: lil-785710

RESUMO

The aim of this study was to evaluate changes in intraocular pressure (IOP), pupil size (PS), blood pressure (BP), heart rate (HR), and ECG variables (Pms wave PmV, PR interval, QRS complex, RMV wave and QT intervals) over time during the instillation of 0.5% timolol, 0.5% levobunolol and 0.5% apraclonidine in clinically normal dogs. Ten adult beagles were used. Baseline values were measured at 8a.m., 2p.m. and 8p.m., for three consecutive days. A waiting period of 10 days between the administrations of each drug was established. For 15 consecutive days, the drug being tested was instilled in one eye of each dog twice a day (7a.m. and 7p.m.). The parameters were evaluated at the aforementioned times on days 3, 6, 9, 12 and 15. Data were statistically compared using the Bonferroni test and one-way repeated measures analysis of variance (P<0.05). The Pearson test was used to evaluate any correlation between QT interval, HR and BP. The tested drugs did not find a decrease in IOP. A significant decreased in PS was observed in almost all dogs following levobunolol administration, relative to the control eye. A significant decrease in HR was observed on day 3 following levobunolol treatment, while apraclonidine induced an increase on day 15. Blood pressure was reduced in all measurement time points following apraclonidine treatment. A negative correlation between QT interval and HR was only observed in dogs treated with timolol. In conclusion, levobunolol was the only drug that induced significant alterations in PS. Apraclonidine was the only drug that induced systemic hypotension. Timolol was the only drug to that induced a negative correlation between QT and HR.(AU)


O objetivo deste estudo foi avaliar as mudanças na pressão intraocular (PIO), no diâmetro pupilar (DP), na pressão sanguínea (PS), na frequência cardíaca (FC) e nas variáveis eletrocardiográficas (onda Pms, PmV, intervalo PR, complexo QRS, onda RmV e intervalo QT), ao longo do tempo da instilação do timolol 0,5%, do levobunolol 0,5% e da apraclonidina 0,5% em cães clinicamente normais. Dez Beagles adultos compuseram o estudo. Valores basais foram mensurados às oito,, 14 e 20 horas, durante três dias consecutivos. Foi instituído um período de espera de 10 dias entre a administração de cada fármaco. Durante 15 dias consecutivos, um olho de cada animal recebeu uma gota de cada um deles, a intervalos de 12 horas (às sete e às 19 horas). Os parâmetros foram avaliados nos momentos acima referidos, nos dias três, seis, nove, 12 e 15. Os dados foram comparados estatisticamente empregando-se o teste de Bonferroni após análise de variância para medidas repetidas (P<0,05). Teste de Pearson foi utilizado para correlação entre o intervalo QT com a FC e a PS. Não se encontrou diminuição da PIO. Observou-se redução significativa do DP na quase totalidade dos animais que receberam levobunol, relativamente ao olho controle. Diminuição significativa da FC foi vista ao terceiro dia após a administração do levobunolol, enquanto apraclonidina induziu aumento no 15º dia. A pressão arterial foi reduzida em todos os momentos com a apraclonidina. Observou-se correlação negativa entre o intervalo QT e a FC apenas nos indivíduos tratados com o timolol. Em conclusão, levobunolol foi o único fármaco que induziu alterações significativas no DP. A apraclonidina foi o único fármaco que induziu hipotensão sistêmica significativa. O timolol foi o único a ensejar correlação negativa entre o intervalo QT e a FC.(AU)


Assuntos
Animais , Cães , Pressão Sanguínea , Frequência Cardíaca , Pressão Intraocular , Levobunolol/efeitos adversos , Levobunolol/análise , Timolol/efeitos adversos , Timolol/análise , Análise de Variância , Instilação de Medicamentos , Pupila
2.
Arab Journal of Pharmaceutical Sciences. 2013; 9 (4): 79-85
em Árabe | IMEMR | ID: emr-142820

RESUMO

Simple, sensitive and specific method for the simultaneous determination of Dorzolamid HCI and Timolol maleate in its dosage form /Eye drops/. The method depended on dilution of 1 volume of the Eye drops 100 time with distillers water, then 10 ml from the resulting solution to 50 ml of water and measure the absorbance at 258 nm and 295 nm against water. The proposed UV-method was successfully applied to the determination of sibotramin in commercial product Timodors [registered sign] [diamondpharm]. The percentage recoveries and the standard division [n=10] were 98.8 +/- 0.92%. For Dorzolamid and 98.1 +/- 0.95 for timolol. The suggested method was compared with HPLC method while the result was conform with the standard method according to statistic Value for F and T tests


Assuntos
Sulfonamidas/análise , Tiofenos/análise , Timolol/análise , Soluções Oftálmicas , Reprodutibilidade dos Testes
3.
Braz. j. pharm. sci ; 48(4): 819-827, Oct.-Dec. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-665878

RESUMO

Transdermal iontophoresis would be a promising method for the systemic delivery of water soluble and ionic drugs of relatively high molecular size, including peptides. The objective of the present study was to investigate the effect of biological variable such as guinea pig and human cadaver skin and other variables like drug concentration, current density on the transdermal iontophoretic transport of timolol maleate. The permeation profile of drug using solution and gel formulation was studied and compared. For better bioavailability, better patient compliance, and enhanced delivery, an iontophoretic drug delivery system of a timolol maleate matrix gel was formulated using Carbopol 974P. The study was conducted using silver-silver chloride electrodes across the guinea pig and human cadaver skin. Viscosity measurements and flux calculations indicated the suitability of the Carbopol 974P gel for transdermal iontophoretic delivery of timolol maleate. Anodal iontophoresis with silver-silver chloride electrode significantly increased the timolol maleate skin permeation as compared with the passive permeation study. The amount of timolol maleate transported during iontophoresis was significantly different among the different skins. However, iontophoretic gel formulations provided required flux of drug through human cadaver skin.


A iontoforese transdérmica seria um método promissor para a liberação sistêmica de fármacos solúveis em água e iônicos de relativamente elevado tamanho molecular, incluindo peptídeos. O objetivo do presente estudo foi investigar o efeito da variável biológica, tais como cobaia e pele de cadáver humano, e outras variáveis como concentração do fármaco, densidade de corrente sobre o transporte transdérmico iontoforético de maleato de timolol. Comparou-se o perfil de permeação do fármaco usando a formulação de solução e de gel. Para melhor biodisponibilidade, melhor adesão do paciente e liberação aprimorada, formulou-se sistema de liberação iontoforética gel de maleato de timolol usando Carbopol 974P. O estudo foi conduzido usando eletrodos de prata-cloreto de prata na cobaia e na pele de cadáver humano. Medidas de viscosidade e de fluxo indicaram a adequação do gel Carbopol 974 P para liberação iontoforética transdérmica do maleato de timolol. A iontoforese anódica com eletrodo de prata-cloreto de prata aumentou significativamente a permeação dérmica do maleato de timolol, comparativamente à permeação passiva. A quantidade de maleato de timolol transportado durante a iontoforese foi significativamente diferente entre as diferentes peles . No entanto, as formulações iontoforéticas de gel forneceram o fluxo necessário do fármaco através da pele de cadáver humano.


Assuntos
Cobaias , Timolol/análise , Iontoforese/classificação , Iontoforese/métodos , LILACS
4.
Arq. bras. oftalmol ; 55(5): 233-7, 1992. tab
Artigo em Português | LILACS | ID: lil-124339

RESUMO

Estudou-se os mesmos pacientes glaucomatosos sem dano do nervo óptico, comparativamente pela CDPo, a açäo hipotensora ocular de 3 drogas: maleato de timolol, betaxolol e levobunolol. O estudo foi precedido de uma CDPo sem medicaçäo. A análise estatística comparativa entre os 3 fármacos näo mostrou diferenças significativas em relaçäo à hipotensäo ocular que cada droga produziu. Näo havendo contra-indicaçäo, a escolha de um deles deve ser feita baseada no senso clínico


Assuntos
Humanos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Betaxolol/análise , Glaucoma/tratamento farmacológico , Pressão Intraocular/efeitos dos fármacos , Levobunolol/análise , Timolol/análise , Betaxolol/uso terapêutico , Brasil , Levobunolol/uso terapêutico , Timolol/uso terapêutico
5.
Arq. bras. oftalmol ; 54(6): 251-61, 1991. ilus, tab
Artigo em Português | LILACS | ID: lil-128715

RESUMO

Foram avaliadas a eficácia como agente hipotensor ocular e a segurança do colírio de maleato de timolol a 0,5//, em 34 indivíduos portadores de hipertensäo ocular ou glaucoma primário de ângulo aberto, por 12 semanas. Os resultados obtidos mostraram equivalência das duas drogas como agentes hipotensores oculares, nos diferentes momentos de estudo. A soluçäo de hidrocloreto de carteolol a 2//, assim como a de maleato de timolol a 0,5//, näo mostrou efeitos colaterais locais ou cardiovasculares


Assuntos
Humanos , Antagonistas Adrenérgicos beta/análise , Carteolol/análise , Glaucoma/prevenção & controle , Hipertensão Ocular/prevenção & controle , Timolol/análise , Antagonistas Adrenérgicos beta/uso terapêutico , Carteolol/uso terapêutico , Hipertensão Ocular/complicações , Timolol/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA