1.
Einstein (Säo Paulo) ; 14(3): 408-414, July-Sept. 2016. graf
Artigo em Inglês | LILACS | ID: lil-796971

RESUMO

ABSTRACT Objective: To present the result of upgrading a clinical gamma-camera to be used to obtain in vivo tomographic images of small animal organs, and its application to register cardiac, renal and neurological images. Methods: An updated version of the miniSPECT upgrading device was built, which is composed of mechanical, electronic and software subsystems. The device was attached to a Discovery VH (General Electric Healthcare) gamma-camera, which was retired from the clinical service and installed at the Centro de Imagem Pré-Clínica of the Hospital Israelita Albert Einstein. The combined system was characterized, determining operational parameters, such as spatial resolution, magnification, maximum acceptable target size, number of projections, and acquisition and reconstruction times. Results: Images were obtained with 0.5mm spatial resolution, with acquisition and reconstruction times between 30 and 45 minutes, using iterative reconstruction with 10 to 20 iterations and 4 projection subsets. The system was validated acquiring in vivo tomographic images of the heart, kidneys and brain of normal animals (mice and adult rats), using the radiopharmaceuticals technetium-labeled hexakis-2-methoxy-isobutyl isonitrile (99mTc-Sestamibi), technetium-labeled dimercaptosuccinic acid (99mTc-DMSA) and technetium-labeled hexamethyl propyleneamine oxime (99mTc-HMPAO). Conclusion: This kind of application, which consists in the adaptation for an alternative objective of already existing instrumentation, resulted in a low-cost infrastructure option, allowing to carry out large scale in vivo studies with enhanced quality in several areas, such as neurology, nephrology, cardiology, among others.


RESUMO Objetivo: Apresentar o resultado da adaptação de uma gama câmara clínica para uso dedicado na obtenção de imagens tomográficas in vivo de órgãos de pequenos animais de experimentação, e de sua aplicação na obtenção de imagens cardíacas, renais e neurológicas. Métodos: Foi construída uma versão atualizada do dispositivo de adaptação miniSPECT, composto por três subsistemas: mecânico, eletrônico e de software. O dispositivo foi montado em uma câmara Discovery VH da General Electric Healthcare, retirada do serviço clínico e instalada no Centro de Imagem Pré-Clínica do Hospital Israelita Albert Einstein. O sistema combinado foi caracterizado, determinando parâmetros de funcionamento como resolução espacial, magnificação, limites de tamanho dos alvos de estudo, número de projeções, tempo de registro e tempo de reconstrução das imagens tomográficas. Resultados: Foram obtidas imagens com resolução espacial de até 0,5mm, com tempos de registro e reconstrução de 30 a 45 minutos, utilizando reconstrução iterativa com 10 a 20 iterações e 4 subconjuntos de projeções. O sistema foi validado obtendo imagens tomográficas in vivo do coração, dos rins e do cérebro de animais normais (camundongos e ratos adultos), utilizando os radiofármacos hexaquis-2-metoxi-isobutil-isonitrila marcado com 99mTc (Sestamibi-99mTc), ácido dimercaptosuccínico marcado com 99mTc (DMSA-99mTc) e hexametil-propileno-amina-oxima marcada com 99mTc (HMPAO-99mTc). Conclusão: Este tipo de aplicação, que consiste na adaptação para um objetivo alternativo de instrumentação já existente, constituiu-se em uma opção de infraestrutura de baixo custo, que permite realizar estudos in vivo em larga escala, com qualidade aprimorada, em áreas diversas, como neurologia, nefrologia, cardiologia, entre outras.


Assuntos
Animais , Masculino , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Imagem Molecular/instrumentação , Pesquisa Translacional Biomédica/instrumentação , Encéfalo/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Imagens de Fantasmas , Modelos Animais , Imagem Molecular/métodos , Coração/anatomia & histologia , Coração/diagnóstico por imagem , Rim/diagnóstico por imagem , Camundongos
2.
Arq. bras. cardiol ; 101(1): 59-67, jul. 2013. ilus
Artigo em Português | LILACS | ID: lil-681836

RESUMO

FUNDAMENTO: Técnicas de imageamento in vivo permitem avaliar sequencialmente a morfologia e a função dos órgãos em diversos modelos experimentais. Desenvolvemos um dispositivo de adaptação de uma gama-câmara clínica para obter imagens tomográficas por emissão de fótons singulares (SPECT) de alta resolução, baseado em colimador pinhole. OBJETIVO: Determinar a acurácia desse sistema na quantificação da área de infarto miocárdico em ratos. MÉTODOS: Treze ratos Wistar machos (250 g) foram submetidos a infarto do miocárdio por oclusão da artéria coronária esquerda. Após 4 semanas, foram adquiridas imagens tomográficas com o sistema desenvolvido, 1,5 hora após a injeção endovenosa de 555MBq de 99mTc-Sestamibi. Na reconstrução tomográfica, utilizamos software especialmente desenvolvido baseado no algoritmo de Máxima Verossimilhança. Comparamos as médias e analisamos a correlação entre a extensão dos defeitos perfusionais detectados pela cintilografia e a extensão da fibrose miocárdica avaliada pela histologia. RESULTADOS: As imagens apresentaram ótima relação órgão-alvo/fundo, com apropriada visualização das paredes e da cavidade do ventrículo esquerdo. Todos os animais exibindo áreas de infarto foram corretamente identificados pelas imagens de perfusão. Não houve diferença entre a área do infarto medida pelo SPECT (21,1 ± 21,2%) e pela histologia (21,7 ± 22,0%; p = 0,45), obtendo forte correlação entre os valores da área de infarto mensurada pelos dois métodos (r = 0,99; p < 0,0001). CONCLUSÃO: O sistema desenvolvido apresentou resolução espacial adequada e elevada acurácia para detecção e quantificação das áreas de infarto miocárdico, sendo uma opção de baixo custo e grande versatilidade na obtenção de imagens em SPECT de alta resolução de órgãos de pequenos roedores.


BACKGROUND: Imaging techniques enable in vivo sequential assessment of the morphology and function of animal organs in experimental models. We developed a device for high-resolution single photon emission computed tomography (SPECT) imaging based on an adapted pinhole collimator. OBJECTIVE: To determine the accuracy of this system for quantification of myocardial infarct area in rats. METHODS: Thirteen male Wistar rats (250 g) underwent experimental myocardial infarction by occlusion of the left coronary artery. After 4 weeks, SPECT images were acquired 1.5 hours after intravenous injection of 555 MBq o f 99mTc-Sestamibi. The tomographic reconstruction was performed by using specially developed software based on the Maximum Likelihood algorithm. The analysis of the data included the correlation between the area of perfusion defects detected by scintigraphy and extent of myocardial fibrosis assessed by histology. RESULTS: The images showed a high target organ/background ratio with adequate visualization of the left ventricular walls and cavity. All animals presenting infarction areas were correctly identified by the perfusion images. There was no difference of the infarct area as measured by SPECT (21.1 ± 21.2%) and by histology (21.7 ± 22.0%; p=0.45). There was a strong correlation between individual values of the area of infarction measured by these two methods. CONCLUSION: The developed system presented adequate spatial resolution and high accuracy for the detection and quantification of myocardial infarction areas, consisting in a low cost and versatile option for high-resolution SPECT imaging of small rodents.


Assuntos
Animais , Masculino , Ratos , Infarto do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Precisão da Medição Dimensional , Processamento de Imagem Assistida por Computador , Infarto do Miocárdio/patologia , Ratos Wistar , Valores de Referência , Fatores de Tempo , Tomografia Computadorizada de Emissão de Fóton Único/economia , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
3.
Braz. j. med. biol. res ; 43(12): 1160-1166, Dec. 2010. ilus
Artigo em Inglês | LILACS | ID: lil-569007

RESUMO

The main objective of the present study was to upgrade a clinical gamma camera to obtain high resolution tomographic images of small animal organs. The system is based on a clinical gamma camera to which we have adapted a special-purpose pinhole collimator and a device for positioning and rotating the target based on a computer-controlled step motor. We developed a software tool to reconstruct the target’s three-dimensional distribution of emission from a set of planar projections, based on the maximum likelihood algorithm. We present details on the hardware and software implementation. We imaged phantoms and heart and kidneys of rats. When using pinhole collimators, the spatial resolution and sensitivity of the imaging system depend on parameters such as the detector-to-collimator and detector-to-target distances and pinhole diameter. In this study, we reached an object voxel size of 0.6 mm and spatial resolution better than 2.4 and 1.7 mm full width at half maximum when 1.5- and 1.0-mm diameter pinholes were used, respectively. Appropriate sensitivity to study the target of interest was attained in both cases. Additionally, we show that as few as 12 projections are sufficient to attain good quality reconstructions, a result that implies a significant reduction of acquisition time and opens the possibility for radiotracer dynamic studies. In conclusion, a high resolution single photon emission computed tomography (SPECT) system was developed using a commercial clinical gamma camera, allowing the acquisition of detailed volumetric images of small animal organs. This type of system has important implications for research areas such as Cardiology, Neurology or Oncology.


Assuntos
Animais , Masculino , Ratos , Câmaras gama/veterinária , Coração , Rim , Modelos Animais , Tomografia Computadorizada de Emissão de Fóton Único/veterinária , Algoritmos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imagens de Fantasmas , Ratos Wistar , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos
5.
J. epilepsy clin. neurophysiol ; 12(3): 169-173, Sept. 2006. ilus
Artigo em Português | LILACS | ID: lil-450952

RESUMO

INTRODUÇÃO: Muitos portadores de epilepsias parciais não apresentam foco epileptogênico facilmente identificado na investigação com EEG de superfície e ressonância magnética (RM). Nestes casos o uso de técnicas de neuroimagem funcional como a tomografia por emissão de pósitrons (PET) interictal e a tomografia por emissão de fóton único (SPECT) ictal devem ser considerados, visando evitar a colocação de eletrodos profundos em alguns casos ou guiar o posicionamento destes em outros. O exame de PET, no entanto, não é disponível em grande parte dos centros de epilepsia, principalmente por seu alto custo. OBJETIVO: O nosso objetivo é demonstrar que a utilização de FDG-18F SPECT interictal pode ser uma boa alternativa ao uso do PET na localização do foco e planejamento cirúrgico. MATERIAIS E MÉTODOS: Relato de uma paciente com epilepsia parcial de lobo temporal neocortical, refratária a tratamento clínico, com RM normal e EEG ictal sem localização definida do foco epileptogênico. RESULTADOS: Após a extensa investigação pré cirúrgica sem resultados satisfatórios optou-se pela realização de exame de medicina nuclear FDG-18F SPECT interictal. O exame demonstrou hipometabolismo na região anterior das porções mesial e lateral do lobo temporal direito. A paciente foi, então, submetida à ressecção destas áreas e permanece com excelente controle de crises (Engel IB) 24 meses após a cirurgia. CONCLUSÃO: O FDG-18F SPECT pode tornar-se um substituto do PET nos locais onde esta tecnologia não é disponível.


INTRODUCTION: Several patients with partial epilepsies do not present an easily identified epileptogenic focus on scalp EEG or visible lesion on MRI. There are some useful functional neuroimaging techniques that could be considered in these cases, such as interictal positron emission tomography (PET) scan and ictal single-photon emission computed tomography (SPECT). These techniques can guide the placement of deep electrodes or even prevent their use in some situations. Unfortunately, PET scanners are not easily available in a great number of epilepsy centers because of its cost. OBJECTIVE: To demonstrate that 18F-FDG SPECT could be a good alternative replacing PET scan on localization of epileptic focus and surgical planning in places where this technology is not available. MATERIALS AND METHODS: Case report of a patient with refractory neocortical temporal lobe epilepsy, with normal MRI and nuclear EEG localization. RESULTS: The patient was submitted to interictal 18F-FDG SPECT scan, that showed hypometabolism in the anterior, mesial and lateral parts of the right temporal lobe. These areas were surgically resected and the patient outcome after 24 moths has been very good (Engel IB). CONCLUSION: We suggest that in some situations an interictal 18F-FDG SPECT scan could replace 18F-FDG PET scan where this technique is not available.


Assuntos
Humanos , Espectroscopia de Ressonância Magnética/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Eletroencefalografia/instrumentação , Epilepsia do Lobo Temporal/diagnóstico por imagem , Medicina Nuclear/métodos
7.
Rev. méd. Chile ; 128(9): 1019-23, sept. 2000. ilus
Artigo em Espanhol | LILACS | ID: lil-274636

RESUMO

We report a 50-year-old woman with a recent myocardial infarction in whom a myocardial perfusion single photon emission computed tomography (SPECT) with Thallium201 was done simultaneously with a F18-fluordeoxyglucose (FDG) SPECT to study glucose metabolism. Myocardial infarction was located in the anteroseptal and apical regions and an echocardiography, done at the second day of evolution, showed a septo-apical hypokinesia. On the tenth day, a coronary angiography showed a critical lesion of the anterior descending coronary artery and an angioplasty with stent placement was performed on the next day. On the twelfth day, a resting, redistribution 201Tl SPECT to study viability and a FDG-SPECT with a dual head high-energy collimator camera were done. Images, acquired 45 min after injection, were analyzed visually. In anterior and medial apical sectors, discordance between flux and metabolism, considered a classical mismatch, was observed. Echocardiographic hypokinesia disappeared three month after revascularization


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Tomografia Computadorizada de Emissão de Fóton Único , Infarto do Miocárdio/diagnóstico , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Fluordesoxiglucose F18 , Reperfusão Miocárdica/métodos , Revascularização Miocárdica