Indian J Dermatol Venereol Leprol ; 2006 Sep-Oct; 72(5): 361-3
Artigo em Inglês | IMSEAR | ID: sea-52648

RESUMO

BACKGROUND: Toxic epidermal necrolysis can be fatal and nursing care with careful monitoring of temperature and humidity can improve survival rate. We adapted the greenhouse and igloo principle using a common hood to monitor the temperature and humidity. METHODS: A small heater with a regulator was placed in a mini hood and temperature was recorded inside the uncovered hood and hood covered with green cloth and aluminium foil separately. The regular hood was placed over a volunteer and the temperature was measured inside the open hood and hood covered with green cloth and aluminium foil separately. The relative humidity was also monitored using Zeal mercury dry--wet bulb hygrometer. RESULTS: Temperature increase was most marked in the foil-covered hood followed by cloth-covered hood, both with the heater and the volunteer. Similarly, in the volunteer study, the humidity was best maintained inside the aluminium foil-covered hood. CONCLUSION: We recommend the use of regular hood with suitable cover to monitor the humidity and temperature of patients with toxic epidermal necrolysis.


Assuntos
Temperatura Corporal/fisiologia , Regulação da Temperatura Corporal/fisiologia , Síndrome de Stevens-Johnson/terapia , Efeito Estufa , Calefação/instrumentação , Humanos , Umidade/normas , Incubadoras/normas , Masculino , Temperatura