RESUMEN

OBJETIVO:

Comparar la resistencia traccional de resina compuesta adherida a la superficie del esmalte de bovino en diferentes intervalos de tiempos de 15 y 30 segundos haciendo uso de ácido grabador en tres agentes cementantes autoadhesivos y un grupo control. MATERIALES Y

MÉTODOS:

Fueron utilizados treinta y cinco incisivos inferiores sanos de bovino menor de 3 años, los cuales fueron divididos aleatoriamente en siete grupos correspondientes a cada cemento autoadhesivo y tiempo de grabado ácido RelyX U200 (3M) (grupo U15") (grupo U30"), Bis Cem (BISCO)(grupo B15")(grupo B30"), MaxCem Elite (KERR)(grupo M15")(grupo M30"), RelyX Ultimate (3M)(grupo UL) se procedió a la cementación con los bloques de resina compuesta como se indica el protocolo previo grabado ácido del esmalte de 15 y 30 segundos para cada cemento . Los especímenes de 1 mm2 de área transversal (n = 30 por grupo) se almacenaron en agua destilada por 24 horas a 36 °C. La prueba de microtensión se realizó haciendo uso del Microtensile Tester (Bisco). Para el análisis estadístico se utilizaron las pruebas de Kruskal Wallis y U Mann Whitney (p<0.05).

RESULTADOS:

El grupo U 30" presentó una resistencia promedio de 24.82 (±3.80) MPa; el U 15", 23.40 (±5.80 ) MPa, el M30",30.86 (±9.85) MPa, el M15", 28.29 (±2.02) MPa, el B 30", 17.42(±3.49) MPa, el B15",17.63 (±3.61) MPa, y el UL, 31.53 (±6.39 ) MPa, encontrando diferencia significativa entre ellos (p < 0.001) a través del análisis de Kruskal Wallis .

CONCLUSIÓN:

El cemento Relyx Ultimate obtuvo el valor más alto de resistencia traccional encontrándose diferencias estadísticamente significativas con todos cementos autoadhesivos. No se encontraron diferencias estadísticamente significativas al comparar los dos tiempos de grabado ácido de 15 y 30 seg. en esmalte entre los grupos de cementos autoadhesivos, al cabo de 24 horas. (AU)
ABSTRACT

OBJECTIVE:

To compare the tensile strength of composite resin bonded to the surface of bovine enamel in different time intervals of 15 to 30 seconds using etchant in three adhesive cementing agents and a control group. MATERIALS AND

METHODS:

The study involved thirty-five healthy lower incisors lower calf of three years, which were rando-mly divided into seven groups corresponding to each adhesive cement and time of etching RelyX U200 (3M) (U15 group ") (group U30 "), Bis Cem (BISCO) (B15 group") (B30 group "), Maxcem Elite (KERR) (M15 group") (M30 group "), RelyX Ultimate (3M) (UL group) proceeded to cementing with blocks Composite protocol as the previous etching enamel 15 and 30 seconds for each indicated cement. Specimens 1 mm2 cross-sectional area (n = 30 per group) were stored in distilled water for 24 hours at 36 ° C. Microtensile test was performed using the Microtensile Tester (Bisco). For statistical analysis, Kruskal Wallis and Mann Whitney U (p <0.05) were used.

RESULTS:

U 30 "group had an average strength of 24.82 (± 3.80) MPa; U 15 ", 23.40 (± 5.80) MPa, the M30", 30.86 (± 9.85) MPa, the M15 ", 28.29 (± 2.02) MPa, the B 30", 17.42 (± 3.49) MPa, B15 " 17.63 (± 3.61) MPa, and UL, 31.53 (± 6.39) MPa, finding significant difference between them (p <0.001) through the analysis of Kruskal Wallis.

CONCLUSION:

The Ultimate Relyx cement had the highest value of tensile strength found statistically significant differences with all adhesive cements. No statistically significant when comparing the acid etching time of 15 to 30 sec differences. between enamel adhesive cements groups, after 24 hours. (AU)