Your browser doesn't support javascript.
loading
Influência do tempo de centrifugação em testes de coagulação: tempo de protrombina e tempo de tromboplastina parcial / Influence of the centrifuge time in coagulation tests: prothrombin time and partial thromboplastin time
Oliveira, Bianca da Rosa; Cruz, Bruno Ribeiro; Moss, Mariane de Faria; Borato, Danielle Cristyane Kalva; Borat, Danielle Cristyane Kalva.
  • Oliveira, Bianca da Rosa; Univerisidade Estadual de Ponta Grossa. Ponta Grossa. BR
  • Cruz, Bruno Ribeiro; Univerisidade Estadual de Ponta Grossa. Ponta Grossa. BR
  • Moss, Mariane de Faria; Univerisidade Estadual de Ponta Grossa. Ponta Grossa. BR
  • Borato, Danielle Cristyane Kalva; Univerisidade Estadual de Ponta Grossa. Ponta Grossa. BR
  • Borat, Danielle Cristyane Kalva; Univerisidade Estadual de Ponta Grossa. Ponta Grossa. BR
Rev. bras. anal. clin ; 51(1): 52-57, 30/03/2019. graf
Article in Portuguese | LILACS | ID: biblio-1008205
RESUMO

Objetivo:

Analisar os testes de coagulação tempo de protrombina (TP) e tempo de tromboplastina parcial (TTP) em diferentes tempos de centrifugação da amostra da biológica, com relação ao protocolo padrão do Clinical Laboratory Standards Institute (CLSI).

Métodos:

As amostras foram divididas em cinco alíquotas de 1 mL. Foi realizada a centrifugação em 15, 10, 5, 2 e 1 minuto, com velocidade de 1500 g. O TP e TTP foram imediatamente analisados em aparelho automatizado. Os plasmas foram analisados para presença de elementos residuais eritrócitos, leucócitos e plaquetas.

Resultados:

Observou-se alteração dos valores do TP nos tempos de centrifugação 10, 5, 2 e 1 minuto e do TTP em 5, 2 e 1 minuto, com relação ao protocolo padrão. Na interpretação de Bland Altman, observou-se um viés significativo do limite clínico aceitável para o TP e para o TTP em todos os tempos de centrifugação, com relação ao protocolo padrão. Apenas no tempo de centrifugação de 15 minutos não foram encontradas células residuais nas amostras analisadas.

Conclusão:

O tempo de centrifugação de 15 minutos é o ideal para remoção completa das células sanguíneas residuais e para garantia da confiabilidade dos resultados dos testes de coagulação TP e TTP.
ABSTRACT

Objective:

To analyze the coagulation tests prothrombin test (PT) and partial thromboplastin time (PTT) in different centrifugation times of the sample, in relation to the standard protocol of the Clinical Laboratory Standards Institute (CLSI).

Methods:

The selected samples were splitted up into five aliquots of 1 mL. Centrifugation of these aliquots was carried out at 15, 10, 5, 2 and 1 minute at 1500 g. The PT and PTT were analyzed in an automated apparatus. The plasmas were analyzed for presence of residual elements erythrocytes, leukocytes and platelets.

Results:

The results showed a change in the values of PT at the 10, 5, 2 and 1 minute centrifugation times and the PTT at 5, 2 and 1 minutes, relative to the standard protocol. In the interpretation of Bland Altman, a significant bias of the acceptable clinical limit for TP and TTP at all centrifugation times was observed, relative to the standard protocol. Only in the 15 minute centrifugation time no residual cells were found in the analyzed samples.

Conclusion:

The present study demonstrated that the 15-minute centrifugation time is ideal for complete removal of residual blood cells and to ensure the reliability of the results of the PT and PTT coagulation
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Prothrombin Time / Blood Coagulation Tests / Centrifugation Type of study: Practice guideline Limits: Female / Humans / Male Language: Portuguese Journal: Rev. bras. anal. clin Journal subject: Pathology Year: 2019 Type: Article Affiliation country: Brazil Institution/Affiliation country: Univerisidade Estadual de Ponta Grossa/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Prothrombin Time / Blood Coagulation Tests / Centrifugation Type of study: Practice guideline Limits: Female / Humans / Male Language: Portuguese Journal: Rev. bras. anal. clin Journal subject: Pathology Year: 2019 Type: Article Affiliation country: Brazil Institution/Affiliation country: Univerisidade Estadual de Ponta Grossa/BR